Screening and confirmation of 62 drugs of abuse and metabolites in urine by ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

3,4 METHYLENEDIOXYAMPHETAMINE; 3,4 METHYLENEDIOXYMETHAMPHETAMINE; 4 METHOXYAMPHETAMINE; AMINOREX; AMPHETAMINE DERIVATIVE; BARBITURIC ACID DERIVATIVE; BENZODIAZEPINE DERIVATIVE; BUTORPHANOL; COCAINE; CODEINE; DIAMORPHINE; DIHYDROCODEINE; EPHEDRINE; FENTANYL; KETAMINE; MEPROBAMATE; METHADONE; METHAMPHETAMINE; METHYLEPHEDRINE; METHYLPHENIDATE; MORPHINE; NALORPHINE; NOREPHEDRINE; PENTAZOCINE; PETHIDINE; PHENTERMINE; PSEUDOEPHEDRINE; TRAMADOL; UNINDEXED DRUG; ZOLPIDEM;

EID: 84885791709     PISSN: 01464760     EISSN: 19452403     Source Type: Journal    
DOI: 10.1093/jat/bkt083     Document Type: Article
Times cited : (38)

References (26)
  • 1
    • 84872031670 scopus 로고    scopus 로고
    • (28 March 2013, date last accessed). Substance Abuse and Mental Health Services Administration
    • Substance Abuse and Mental Health Services Administration (2012) Results from the 2011 National Survey on Drug Use and Health: Summary of National Findings. http://www.samhsa.gov/data/nsduh/ 2k11results/nsduhresults2011.pdf (28 March 2013, date last accessed).
    • (2012) Results from the 2011 National Survey on Drug Use and Health: Summary of National Findings
  • 3
    • 84856730457 scopus 로고    scopus 로고
    • Screening and selective quantification of illicit drugs in wastewater by mixed-mode solid-phase extraction and quadrupoletime-of-flight liquid chromatography-mass spectrometry
    • Gonzalez-Marino, I., Quintana, J.B., Rodriguez, I., Gonzalez-Diez, M., Cela, R. (2012) Screening and selective quantification of illicit drugs in wastewater by mixed-mode solid-phase extraction and quadrupoletime-of-flight liquid chromatography-mass spectrometry. Analytical Chemistry, 84, 1708-1717.
    • (2012) Analytical Chemistry , vol.84 , pp. 1708-1717
    • Gonzalez-Marino, I.1    Quintana, J.B.2    Rodriguez, I.3    Gonzalez-Diez, M.4    Cela, R.5
  • 4
    • 77953338806 scopus 로고    scopus 로고
    • An evaluation of the diagnostic accuracy of liquid chromatography-tandem mass spectrometry versus immunoassay drug testing in pain patients
    • Pesce, A., Rosenthal, M., West, R., West, C., Crews, B., Mikel, C. et al. (2010) An evaluation of the diagnostic accuracy of liquid chromatography-tandem mass spectrometry versus immunoassay drug testing in pain patients. Pain Physician, 13, 273-281.
    • (2010) Pain Physician , vol.13 , pp. 273-281
    • Pesce, A.1    Rosenthal, M.2    West, R.3    West, C.4    Crews, B.5    Mikel, C.6
  • 5
    • 0033921167 scopus 로고    scopus 로고
    • Automated solidphase extraction and two-step derivatisation for simultaneous analysis of basic illicit drugs in serum by GC/MS
    • Weinmann, W., Renz, M., Vogt, S., Pollak, S. (2000) Automated solidphase extraction and two-step derivatisation for simultaneous analysis of basic illicit drugs in serum by GC/MS. International Journal of Legal Medicine, 113, 229-235.
    • (2000) International Journal of Legal Medicine , vol.113 , pp. 229-235
    • Weinmann, W.1    Renz, M.2    Vogt, S.3    Pollak, S.4
  • 8
    • 79958086473 scopus 로고    scopus 로고
    • Development of a solvent-free method for the simultaneous identification/ quantification of drugs of abuse and their metabolites in environmental water by LC-MS/MS
    • Bueno, M.J.M., Ucles, S., Hernando, M.D., Fernandez-Alba, A.R. (2011) Development of a solvent-free method for the simultaneous identification/ quantification of drugs of abuse and their metabolites in environmental water by LC-MS/MS. Talanta, 85, 157-166.
    • (2011) Talanta , vol.85 , pp. 157-166
    • Bueno, M.J.M.1    Ucles, S.2    Hernando, M.D.3    Fernandez-Alba, A.R.4
  • 9
    • 84877125998 scopus 로고    scopus 로고
    • What is the future of (ultra) high performance liquid chromatography coupled to low and high resolution mass spectrometry for toxicological drug screening?
    • doi:10.1016/j.chroma.2012.08.069
    • Maurer, H.H. (2012) What is the future of (ultra) high performance liquid chromatography coupled to low and high resolution mass spectrometry for toxicological drug screening? Journal of Chromatography A, doi:10.1016/j.chroma.2012.08.069.
    • (2012) Journal of Chromatography A
    • Maurer, H.H.1
  • 11
    • 68049135677 scopus 로고    scopus 로고
    • Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-of-flight mass spectrometry
    • Lee, H.K., Ho, C.S., Iu, Y.P.H., Lai, P.S.J., Shek, C.C., Lo, Y.C. et al. (2009) Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-of-flight mass spectrometry. Analytica Chimica Acta, 649, 80-90.
    • (2009) Analytica Chimica Acta , vol.649 , pp. 80-90
    • Lee, H.K.1    Ho, C.S.2    Iu, Y.P.H.3    Lai, P.S.J.4    Shek, C.C.5    Lo, Y.C.6
  • 12
    • 77950969147 scopus 로고    scopus 로고
    • Generic sample preparation and dual polarity liquid chromatography- time-of-flight mass spectrometry for high-throughput screening in doping analysis
    • Kolmonen, M., Leinonen, A., Kuuranne, T., Pelander, A., Ojanpera, I. (2009) Generic sample preparation and dual polarity liquid chromatography- time-of-flight mass spectrometry for high-throughput screening in doping analysis. Drug Testing and Analysis, 1, 250-266.
    • (2009) Drug Testing and Analysis , vol.1 , pp. 250-266
    • Kolmonen, M.1    Leinonen, A.2    Kuuranne, T.3    Pelander, A.4    Ojanpera, I.5
  • 15
    • 84861230527 scopus 로고    scopus 로고
    • Current use of highresolution mass spectrometry in drug screening relevant to clinical and forensic toxicology and doping control
    • Ojanpera, I., Kolmonen, M., Pelander, A. (2012) Current use of highresolution mass spectrometry in drug screening relevant to clinical and forensic toxicology and doping control. Analytical and Bioanalytical Chemistry, 403, 1203-1220.
    • (2012) Analytical and Bioanalytical Chemistry , vol.403 , pp. 1203-1220
    • Ojanpera, I.1    Kolmonen, M.2    Pelander, A.3
  • 16
    • 33846624349 scopus 로고    scopus 로고
    • A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry
    • Kolmonen, M., Leinonen, A., Pelander, A., Ojanpera, I. (2007) A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry. Analytica Chimica Acta, 585, 94-102.
    • (2007) Analytica Chimica Acta , vol.585 , pp. 94-102
    • Kolmonen, M.1    Leinonen, A.2    Pelander, A.3    Ojanpera, I.4
  • 17
    • 0242322764 scopus 로고    scopus 로고
    • Toxicological screening with formula-based metabolite identification by liquid chromatography/time-of-flight mass spectrometry
    • Pelander, A., Ojanpera, I., Laks, S., Rasanen, I., Vuori, E. (2003) Toxicological screening with formula-based metabolite identification by liquid chromatography/time-of-flight mass spectrometry. Analytical Chemistry, 75, 5710-5718.
    • (2003) Analytical Chemistry , vol.75 , pp. 5710-5718
    • Pelander, A.1    Ojanpera, I.2    Laks, S.3    Rasanen, I.4    Vuori, E.5
  • 18
    • 0035029350 scopus 로고    scopus 로고
    • Toxicological screening of urine for drugs by liquid chromatography/time-of-flight mass spectrometry with automated target library search based on elemental formulas
    • Gergov, M., Boucher, B., Ojanpera, I., Vuori, E. (2001) Toxicological screening of urine for drugs by liquid chromatography/time-of-flight mass spectrometry with automated target library search based on elemental formulas. Rapid Communications in Mass Spectrometry, 15, 521-526.
    • (2001) Rapid Communications in Mass Spectrometry , vol.15 , pp. 521-526
    • Gergov, M.1    Boucher, B.2    Ojanpera, I.3    Vuori, E.4
  • 19
    • 84865614071 scopus 로고    scopus 로고
    • Screening analysis for medicinal drugs and drugs of abuse in whole blood using ultraperformance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS)-toxicological findings in cases of alleged sexual assault
    • Birkler, R.I.D., Telving, R., Ingemann-Hansen, O., Charles, A.V., Johannsen, M., Andreasen, M.F. (2012) Screening analysis for medicinal drugs and drugs of abuse in whole blood using ultraperformance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS)-toxicological findings in cases of alleged sexual assault. Forensic Science International, 222, 154-161.
    • (2012) Forensic Science International , vol.222 , pp. 154-161
    • Birkler, R.I.D.1    Telving, R.2    Ingemann-Hansen, O.3    Charles, A.V.4    Johannsen, M.5    Andreasen, M.F.6
  • 21
    • 84875506938 scopus 로고    scopus 로고
    • Evaluation of high-resolution mass spectrometry for urine toxicology screening in a pain management setting
    • Crews, B.O., Pesce, A.J., West, R., Nguyen, H., Fitzgerald, R.L. (2012) Evaluation of high-resolution mass spectrometry for urine toxicology screening in a pain management setting. Journal of Analytical Toxicology, 36, 601-607.
    • (2012) Journal of Analytical Toxicology , vol.36 , pp. 601-607
    • Crews, B.O.1    Pesce, A.J.2    West, R.3    Nguyen, H.4    Fitzgerald, R.L.5
  • 22
    • 84872766508 scopus 로고    scopus 로고
    • Validation of LCTOF-MS screening for drugs, metabolites, and collateral compounds in forensic toxicology specimens
    • Guale, F., Shahreza, S., Walterscheid, J.P., Chen, H.H., Arndt, C., Kelly, A.T. et al. (2013) Validation of LCTOF-MS screening for drugs, metabolites, and collateral compounds in forensic toxicology specimens. Journal of Analytical Toxicology, 37, 17-24.
    • (2013) Journal of Analytical Toxicology , vol.37 , pp. 17-24
    • Guale, F.1    Shahreza, S.2    Walterscheid, J.P.3    Chen, H.H.4    Arndt, C.5    Kelly, A.T.6
  • 23
    • 67349167978 scopus 로고    scopus 로고
    • Urine levels of drugs for which Triage DOA screening was positive
    • Moriya, F. (2009) Urine levels of drugs for which Triage DOA screening was positive. Legal Medicine, 11, S434-S436.
    • (2009) Legal Medicine , vol.11
    • Moriya, F.1
  • 25
    • 84885803332 scopus 로고    scopus 로고
    • Taiwan, ROC: Department of Health, Executive Yuan Department of Health, Executive Yuan (28 March 2013, date last accessed)
    • Department of Health, Executive Yuan (2008) Regulations Governing Drug Abuse Urine Testing Operations. Taiwan, ROC: Department of Health, Executive Yuan. http://dohlaw.doh.gov.tw/Chi/EngContent. asp?Msgid=114&KeyWord=(28 March 2013, date last accessed).
    • (2008) Regulations Governing Drug Abuse Urine Testing Operations
  • 26
    • 0042827437 scopus 로고    scopus 로고
    • Criteria for the identification of compounds by liquid chromatography-mass spectrometry and liquid chromatographymultiple mass spectrometry in forensic toxicology and doping analysis
    • Rivier, L. (2003) Criteria for the identification of compounds by liquid chromatography-mass spectrometry and liquid chromatographymultiple mass spectrometry in forensic toxicology and doping analysis. Analytica Chimica Acta, 492, 69-82.
    • (2003) Analytica Chimica Acta , vol.492 , pp. 69-82
    • Rivier, L.1