메뉴 건너뛰기




Volumn 16, Issue 4, 2013, Pages 250-256

Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures

Author keywords

Anesthesia; Continuous flow left ventricular assist devices; Monitored anesthesia care; Non cardiac surgery

Indexed keywords

ANESTHETIC AGENT; EPHEDRINE; ETOMIDATE; FENTANYL; HYPERTENSIVE FACTOR; INFUSION FLUID; ISOFLURANE; KETAMINE; MIDAZOLAM; MILRINONE; OPIATE; PHENYLEPHRINE; PROPOFOL; SEVOFLURANE;

EID: 84885592127     PISSN: 09719784     EISSN: 09745181     Source Type: Journal    
DOI: 10.4103/0971-9784.119167     Document Type: Article
Times cited : (21)

References (21)
  • 2
    • 33747366081 scopus 로고    scopus 로고
    • Progress versus precision: Challenges in clinical trial design for left ventricular assist devices
    • Parides MK, Moskowitz AJ, Ascheim DD, Rose EA, Gelijns AC. Progress versus precision: Challenges in clinical trial design for left ventricular assist devices. Ann Thorac Surg 2006;82:1140-6.
    • (2006) Ann Thorac Surg , vol.82 , pp. 1140-1146
    • Parides, M.K.1    Moskowitz, A.J.2    Ascheim, D.D.3    Rose, E.A.4    Gelijns, A.C.5
  • 3
    • 84885616197 scopus 로고    scopus 로고
    • Comparison of acoustic respiration rate, impedance pneumography and capnometry monitors for respiration rate accuracy and apnea detection during GI endoscopy anesthesia
    • Goudra BG, Penugonda LC, Speck RM, Sinha AC. Comparison of acoustic respiration rate, impedance pneumography and capnometry monitors for respiration rate accuracy and apnea detection during GI endoscopy anesthesia. Open J Anesthesiol 2013;3:74-9.
    • (2013) Open J Anesthesiol , vol.3 , pp. 74-79
    • Goudra, B.G.1    Penugonda, L.C.2    Speck, R.M.3    Sinha, A.C.4
  • 5
    • 84866403058 scopus 로고    scopus 로고
    • Elective noncardiac surgery in patients with left ventricular assist devices
    • Ahmed M, Le H, Aranda JM Jr, Klodell CT. Elective noncardiac surgery in patients with left ventricular assist devices. J Card Surg 2012;27:639-42.
    • (2012) J Card Surg , vol.27 , pp. 639-642
    • Ahmed, M.1    Le, H.2    Aranda Jr., J.M.3    Klodell, C.T.4
  • 6
    • 78650409758 scopus 로고    scopus 로고
    • HeartMate ® II continuous-flow left ventricular assist system
    • Sheikh FH, Russell SD. HeartMate ® II continuous-flow left ventricular assist system. Expert Rev Med Devices 2011;8:11-21.
    • (2011) Expert Rev Med Devices , vol.8 , pp. 11-21
    • Sheikh, F.H.1    Russell, S.D.2
  • 7
    • 0036292395 scopus 로고    scopus 로고
    • The anesthetic considerations in patients with ventricular assist devices presenting for noncardiac surgery: A review of eight cases
    • Stone ME, Soong W, Krol M, Reich DL. The anesthetic considerations in patients with ventricular assist devices presenting for noncardiac surgery: A review of eight cases. Anesth Analg 2002;95:42-9.
    • (2002) Anesth Analg , vol.95 , pp. 42-49
    • Stone, M.E.1    Soong, W.2    Krol, M.3    Reich, D.L.4
  • 8
    • 58249093243 scopus 로고    scopus 로고
    • Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
    • Crow S, John R, Boyle A, Shumway S, Liao K, Colvin-Adams M, et al. Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices. J Thorac Cardiovasc Surg 2009;137:208-15.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 208-215
    • Crow, S.1    John, R.2    Boyle, A.3    Shumway, S.4    Liao, K.5    Colvin-Adams, M.6
  • 9
    • 40649123746 scopus 로고    scopus 로고
    • Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease
    • Geisen U, Heilmann C, Beyersdorf F, Benk C, Berchtold-Herz M, Schlensak C, et al. Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. Eur J Cardiothorac Surg 2008;33:679-84.
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 679-684
    • Geisen, U.1    Heilmann, C.2    Beyersdorf, F.3    Benk, C.4    Berchtold-Herz, M.5    Schlensak, C.6
  • 10
    • 56249139674 scopus 로고    scopus 로고
    • Low thromboembolic risk for patients with the Heartmate II left ventricular assist device
    • John R, Kamdar F, Liao K, Colvin-Adams M, Miller L, Joyce L, et al. Low thromboembolic risk for patients with the Heartmate II left ventricular assist device. J Thorac Cardiovasc Surg 2008;136:1318-23.
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 1318-1323
    • John, R.1    Kamdar, F.2    Liao, K.3    Colvin-Adams, M.4    Miller, L.5    Joyce, L.6
  • 11
    • 52049104955 scopus 로고    scopus 로고
    • Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy
    • John R, Kamdar F, Liao K, Colvin-Adams M, Boyle A, Joyce L. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy. Ann Thorac Surg 2008;86:1227-34.
    • (2008) Ann Thorac Surg , vol.86 , pp. 1227-1234
    • John, R.1    Kamdar, F.2    Liao, K.3    Colvin-Adams, M.4    Boyle, A.5    Joyce, L.6
  • 13
    • 78650093211 scopus 로고    scopus 로고
    • Right ventricular function and left ventricular assist device placement: Clinical considerations and outcomes
    • Lainez R, Parrino G, Bates M. Right ventricular function and left ventricular assist device placement: Clinical considerations and outcomes. Ochsner J 2010;10:241-4.
    • (2010) Ochsner J , vol.10 , pp. 241-244
    • Lainez, R.1    Parrino, G.2    Bates, M.3
  • 14
    • 79959420436 scopus 로고    scopus 로고
    • Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices
    • Topilsky Y, Maltais S, Oh JK, Atchison FW, Perrault LP, Carrier M, et al. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices. Cardiol Res Pract 2011;2011:187434.
    • (2011) Cardiol Res Pract , vol.2011 , pp. 187434
    • Topilsky, Y.1    Maltais, S.2    Oh, J.K.3    Atchison, F.W.4    Perrault, L.P.5    Carrier, M.6
  • 15
    • 0037129864 scopus 로고    scopus 로고
    • Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    • Frazier OH, Myers TJ, Gregoric ID, Khan T, Delgado R, Croitoru M, et al. Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation 2002;105:2855-60.
    • (2002) Circulation , vol.105 , pp. 2855-2860
    • Frazier, O.H.1    Myers, T.J.2    Gregoric, I.D.3    Khan, T.4    Delgado, R.5    Croitoru, M.6
  • 16
    • 84862229091 scopus 로고    scopus 로고
    • Effect of a fluid challenge on the Surgical Pleth Index during stable propofol-remifentanil anaesthesia
    • Hans P, Verscheure S, Uutela K, Hans G, Bonhomme V. Effect of a fluid challenge on the Surgical Pleth Index during stable propofol-remifentanil anaesthesia. Acta Anaesthesiol Scand 2012;56:787-96.
    • (2012) Acta Anaesthesiol Scand , vol.56 , pp. 787-796
    • Hans, P.1    Verscheure, S.2    Uutela, K.3    Hans, G.4    Bonhomme, V.5
  • 17
    • 33845650245 scopus 로고    scopus 로고
    • Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: A clinical trial
    • Natalini G, Rosano A, Taranto M, Faggian B, Vittorielli E, Bernardini A. Arterial versus plethysmographic dynamic indices to test responsiveness for testing fluid administration in hypotensive patients: A clinical trial. Anesth Analg 2006;103:1478-84.
    • (2006) Anesth Analg , vol.103 , pp. 1478-1484
    • Natalini, G.1    Rosano, A.2    Taranto, M.3    Faggian, B.4    Vittorielli, E.5    Bernardini, A.6
  • 18
    • 84879336780 scopus 로고    scopus 로고
    • Anesthesia for ERCP: Impact of Anesthesiologist's Experience on Outcome and Cost
    • Basavana G. Goudra, Preet Mohinder Singh, and Ashish C. Sinha, "Anesthesia for ERCP: Impact of Anesthesiologist's Experience on Outcome and Cost, " Anesthesiology Research and Practice, 2013, 2013:5.
    • (2013) Anesthesiology Research and Practice , vol.2013 , pp. 5
    • Basavana, G.G.1    Preet, M.S.2    Ashish, C.S.3
  • 19
    • 84882255323 scopus 로고    scopus 로고
    • Outpatient endoscopic retrograde cholangiopancreatography: Safety and efficacy of anesthetic management with a natural airway in 653 consecutive procedures
    • Goudra BG, Singh PM, Sinha AC. Outpatient endoscopic retrograde cholangiopancreatography: Safety and efficacy of anesthetic management with a natural airway in 653 consecutive procedures. Saudi J Anaesth 2013;7:259-65.
    • (2013) Saudi J Anaesth , vol.7 , pp. 259-265
    • Goudra, B.G.1    Singh, P.M.2    Sinha, A.C.3
  • 20
    • 84856907900 scopus 로고    scopus 로고
    • Continuous-flow left ventricular assist device and the right ventricle
    • Puhlman M. Continuous-flow left ventricular assist device and the right ventricle. AACN Adv Crit Care 2012;23:86-90.
    • (2012) AACN Adv Crit Care , vol.23 , pp. 86-90
    • Puhlman, M.1
  • 21
    • 0036156179 scopus 로고    scopus 로고
    • Effects of milrinone for right ventricular failure after left ventricular assist device implantation
    • Kihara S, Kawai A, Fukuda T, Yamamoto N, Aomi S, Nishida H, et al. Effects of milrinone for right ventricular failure after left ventricular assist device implantation. Heart Vessels 2002;16:69-71.
    • (2002) Heart Vessels , vol.16 , pp. 69-71
    • Kihara, S.1    Kawai, A.2    Fukuda, T.3    Yamamoto, N.4    Aomi, S.5    Nishida, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.