메뉴 건너뛰기




Volumn 187, Issue , 2013, Pages 147-152

An enzyme-metal-insulator-silicon structured sensor using surface photovoltage technology for potentiometric glucose detection

Author keywords

Electroactive polymer; Electropolymerization; Enzyme metal insulator silicon sensor; Potentiometric glucose detection; Surface photovoltage technology

Indexed keywords

CONDUCTING POLYMERS; ELECTROPOLYMERIZATION; ENZYME ACTIVITY; ENZYMES; GLUCOSE; GLUCOSE SENSORS; METAL INSULATOR BOUNDARIES; METALS; POLYPYRROLES; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); SILICON; SURFACE PROPERTIES;

EID: 84885473393     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.10.034     Document Type: Article
Times cited : (5)

References (32)
  • 1
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • L.C. Clark Jr., C. Lyons, Electrode systems for continuous monitoring in cardiovascular surgery, Annals of the New York Academy of Sciences 102 (1962) 29-45.
    • (1962) Annals of the New York Academy of Sciences , vol.102 , pp. 29-45
    • Clark Jr., L.C.1    Lyons, C.2
  • 2
    • 40449109054 scopus 로고    scopus 로고
    • Electrochemical glucose biosensors
    • J. Wang, Electrochemical glucose biosensors, Chemical Reviews 108(2008)814.
    • (2008) Chemical Reviews , vol.108 , pp. 814
    • Wang, J.1
  • 3
    • 0014191637 scopus 로고
    • The enzyme electrode
    • S. Updike, G. Hicks, The enzyme electrode, Nature 214 (1967) 986-988.
    • (1967) Nature , vol.214 , pp. 986-988
    • Updike, S.1    Hicks, G.2
  • 4
    • 0001805813 scopus 로고
    • A chemically-modified enzyme membrane electrode as an amperometric glucose sensor
    • T. Yao, A chemically-modified enzyme membrane electrode as an amperometric glucose sensor, AnalyticaChimica Acta 148 (1983) 27-33.
    • (1983) AnalyticaChimica Acta , vol.148 , pp. 27-33
    • Yao, T.1
  • 5
    • 0000379561 scopus 로고    scopus 로고
    • Electrical Contact of Redox Enzyme Layers Associated with Electrodes: Routes to Amperometric Biosensors
    • I. Willner, E. Katz, B. Willner, Electrical contact of redox enzyme layers associated with electrodes: routes to amperometric biosensors, Electroanalysis 9 (1997)965-977. (Pubitemid 127441335)
    • (1997) Electroanalysis , vol.9 , Issue.13 , pp. 965-977
    • Willner, I.1    Katz, E.2    Willner, B.3
  • 6
    • 0034599876 scopus 로고    scopus 로고
    • Integration of layered redox proteins and conductive supports for bioelectronic applications
    • DOI 10.1002/(SICI)1521-3773(20000403)39:7<1180::AID-ANIE1180>3.0. CO;2-E
    • I. Willner, E. Katz, Integration of layered redox proteins and conductive supports forbioelectronic applications, Angewandte Chemie International Edition 39 (2000)1180-1218. (Pubitemid 30219908)
    • (2000) Angewandte Chemie - International Edition , vol.39 , Issue.7 , pp. 1180-1218
    • Willner, I.1    Katz, E.2
  • 8
    • 77953550897 scopus 로고    scopus 로고
    • A comprehensive review of glucose biosensors based on nanostructured metal-oxides
    • M.M. Rahman, A. Ahammad, J.H. Jin, S.J. Ahn, J.J. Lee, A comprehensive review of glucose biosensors based on nanostructured metal-oxides, Sensors 10 (2010) 4855-4886.
    • (2010) Sensors , vol.10 , pp. 4855-4886
    • Rahman, M.M.1    Ahammad, A.2    Jin, J.H.3    Ahn, S.J.4    Lee, J.J.5
  • 10
    • 0021233557 scopus 로고
    • Immobilized glucose oxidase in the potentiometric detection of glucose
    • L.B. Wingard, J.F. Castner, S.J. Yao, S.K. Wolfson, A.L. Drash, C.C. Liu, Immobilized glucose oxidase in the potentiometric detection of glucose, Applied Biochemistry and Biotechnology 9 (1984) 95-104. (Pubitemid 14079411)
    • (1984) Applied Biochemistry and Biotechnology , vol.9 , Issue.1 , pp. 95-104
    • Wingard Jr., L.B.1    Castner, J.F.2    Yao, S.J.3
  • 14
    • 0025139767 scopus 로고
    • Enzyme entrapped polypyrrole modified electrode for flow-injection determination of glucose
    • DOI 10.1016/0956-5663(90)80005-X
    • M. Trojanowicz, W. Matuszewski, M. Podsiadla, Enzyme entrapped polypyrrole modified electrode for flow-injection determination ofglucose, Biosensors and Bioelectronics 5 (1990) 149-156. (Pubitemid 20040962)
    • (1990) Biosensors and Bioelectronics , vol.5 , Issue.2 , pp. 149-156
    • Trojanowicz, M.1    Matuszewski, W.2    Podsiadla, M.3
  • 15
    • 0026435795 scopus 로고
    • Amperometric polypyrrole enzyme electrodes: Effect of permeability and enzyme location
    • M. Hämmerle, W. Schuhmann, H.L. Schmidt, Amperometric polypyrrole enzyme electrodes: effect of permeability and enzyme location, Sensors and Actuators B: Chemical 6 (1992) 106-112.
    • (1992) Sensors and Actuators B: Chemical , vol.6 , pp. 106-112
    • Hämmerle, M.1    Schuhmann, W.2    Schmidt, H.L.3
  • 16
    • 0026152352 scopus 로고
    • Amperometric substrate determination in flow-injection systems with polypyrrole-enzyme electrodes
    • W. Schuhmann, Amperometric substrate determination in flow-injection systems with polypyrrole-enzyme electrodes, Sensors and Actuators B: Chemical 4 (1991) 41-49. (Pubitemid 21678255)
    • (1991) Sensors and Actuators, B: Chemical , vol.B4 , Issue.1-2 , pp. 41-49
    • Schuhmann Wolfgang1
  • 17
    • 0039633245 scopus 로고
    • Enzyme entrapment in electrically conducting polymers. Immobilisation ofglucose oxidase in polypyrrole and its application in amperometric glucose sensors
    • N.C. Foulds, CR. Lowe, Enzyme entrapment in electrically conducting polymers. Immobilisation ofglucose oxidase in polypyrrole and its application in amperometric glucose sensors, Journal of the Chemical Society, Faraday Transactions 182(1986)1259-1264.
    • (1986) Journal of the Chemical Society, Faraday Transactions , vol.182 , pp. 1259-1264
    • Foulds, N.C.1    Lowe, C.R.2
  • 18
    • 0001719327 scopus 로고    scopus 로고
    • A Potentiometric Polypyrrole-Based Glucose Biosensor
    • M. Trojanowicz, M.L. Hitchman, A potentiometric polypyrrole-based glucose biosensor, Electroanalysis 8 (1996) 263-266. (Pubitemid 126419520)
    • (1996) Electroanalysis , vol.8 , Issue.3 , pp. 263-266
    • Trojanowicz, M.1    Hitchman, M.L.2
  • 19
    • 0029885257 scopus 로고    scopus 로고
    • Conducting polymers and the bioanalytical sciences: New tools for biomolecular communications. A review
    • S. Adeloju, G. Wallace, Conducting polymers and the bioanalytical sciences: new tools for biomolecular communications. A review, Analyst 121 (1996) 699-703.
    • (1996) Analyst , vol.121 , pp. 699-703
    • Adeloju, S.1    Wallace, G.2
  • 20
    • 37049069173 scopus 로고
    • Electrocatalysis usingelectroactive polymers, electroactive composites and microheterogeneous systems
    • M.E.G. Lyons, Electrocatalysis usingelectroactive polymers, electroactive composites and microheterogeneous systems, Analyst 119 (1994) 805-826.
    • (1994) Analyst , vol.119 , pp. 805-826
    • Lyons, M.E.G.1
  • 21
    • 0031889621 scopus 로고    scopus 로고
    • Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: A glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer
    • DOI 10.1016/S0956-5663(97)00064-X, PII S095656639700064X
    • A. Guerrieri, G. De Benedetto, F. Palmisano, P. Zambonin, Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer, Biosensors and Bioelectronics 13(1998) 103-112. (Pubitemid 28101606)
    • (1998) Biosensors and Bioelectronics , vol.13 , Issue.1 , pp. 103-112
    • Guerrieri, A.1    De Benedetto, G.E.2    Palmisano, F.3    Zambonin, P.G.4
  • 22
    • 0030597126 scopus 로고    scopus 로고
    • Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite
    • DOI 10.1016/0003-2670(96)00261-9, PII S0003267096002619
    • S. Adeloju, J. Barisci, G. Wallace, Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite, AnalyticaChimica Acta 332 (1996) 145-153. (Pubitemid 26358894)
    • (1996) Analytica Chimica Acta , vol.332 , Issue.2-3 , pp. 145-153
    • Adeloju, S.B.1    Barisci, J.N.2    Wallace, G.G.3
  • 23
    • 0030978501 scopus 로고    scopus 로고
    • Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
    • DOI 10.1016/S0003-2670(96)00502-8, PII S0003267096005028
    • S. Adeloju, S. Shaw, G. Wallace, Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor, Analytica Chimica Acta 341 (1997)155-160. (Pubitemid 27190480)
    • (1997) Analytica Chimica Acta , vol.341 , Issue.2-3 , pp. 155-160
    • Adeloju, S.B.1    Shaw, S.J.2    Wallace, G.G.3
  • 27
    • 0031688084 scopus 로고    scopus 로고
    • Biosensors based on light-addressable potentiometric sensors for urea, penicillin and glucose
    • DOI 10.1016/S0003-2670(98)00364-X, PII S000326709800364X
    • A. Seki, S. Ikeda, I. Kubo, I. Karube, Biosensors based on light-addressable potentiometric sensors for urea, penicillin and glucose, Analytica Chimica Acta 373 (1998) 9-13. (Pubitemid 28428897)
    • (1998) Analytica Chimica Acta , vol.373 , Issue.1 , pp. 9-13
    • Seki, A.1    Ikeda, S.-I.2    Kubo, I.3    Karube, I.4
  • 28
    • 0024298341 scopus 로고
    • Light-addressable potentiometric sensor for biochemical systems
    • D.G. Hafeman, J.W. Parce, H.M. McConnell, Light-addressable potentiometric sensor for biochemical systems, Science 240(1988) 1182-1185.
    • (1988) Science , vol.240 , pp. 1182-1185
    • Hafeman, D.G.1    Parce, J.W.2    McConnell, H.M.3
  • 31
    • 0029010309 scopus 로고
    • Characterization and enzymatic application of a redox potential biosensor based on a silicon transducer
    • M. Adami, M. Martini, L. Piras, Characterization and enzymatic application of a redox potential biosensor based on a silicon transducer, Biosensors and Bioelectronics 10 (1995) 633-638.
    • (1995) Biosensors and Bioelectronics , vol.10 , pp. 633-638
    • Adami, M.1    Martini, M.2    Piras, L.3
  • 32
    • 0035341205 scopus 로고    scopus 로고
    • Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose
    • DOI 10.1016/S0956-5663(00)00117-2, PII S0956566300001172
    • S.B. Adeloju, A.N. Moline, Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing ofglucose, Biosensors and Bioelectronics 16 (2001) 133-139. (Pubitemid 32406272)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.3 , pp. 133-139
    • Adeloju, S.B.1    Moline, A.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.