메뉴 건너뛰기




Volumn 13, Issue 1, 1998, Pages 103-112

Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: A glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer

Author keywords

Biosensor; Enzyme co crosslinking; Enzyme immobilization; Flow injection analysis; Glucose; Overoxidized polypyrrole; Serum

Indexed keywords

AMPEROMETRIC SENSORS; BIOASSAY; CONDUCTIVE PLASTICS; CROSSLINKING; ENZYME IMMOBILIZATION; GLUCOSE SENSORS; SYNTHESIS (CHEMICAL);

EID: 0031889621     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(97)00064-X     Document Type: Article
Times cited : (87)

References (24)
  • 1
    • 0023366295 scopus 로고
    • Electroimmobilisation of enzymes. Part I. Theory
    • Bartlett, P. N. and Whitaker, R. G. (1987a) Electroimmobilisation of enzymes. Part I. Theory. J. Electroanal. Chem. 224, 27-35.
    • (1987) J. Electroanal. Chem. , vol.224 , pp. 27-35
    • Bartlett, P.N.1    Whitaker, R.G.2
  • 2
    • 0023363285 scopus 로고
    • Electroimmobilisation of enzymes. Part II. Gluoxidase immobilised in poly-N-methylpyrrole
    • Bartlett, P. N. and Whitaker, R. G. (1987b) Electroimmobilisation of enzymes. Part II. Gluoxidase immobilised in poly-N-methylpyrrole. J. Electroanal. Chem. 224, 37-48.
    • (1987) J. Electroanal. Chem. , vol.224 , pp. 37-48
    • Bartlett, P.N.1    Whitaker, R.G.2
  • 3
    • 0000013475 scopus 로고
    • Electrochemical immobilization of enzymes. 3. Immobilization of glucose oxidase in thin film of electrochemically polymerized phenols
    • Bartlett, P. N., Tebbutt, P. and Tyrrell, C. H. (1992) Electrochemical immobilization of enzymes. 3. Immobilization of glucose oxidase in thin film of electrochemically polymerized phenols. Anal. Chem. 64, 138-142.
    • (1992) Anal. Chem. , vol.64 , pp. 138-142
    • Bartlett, P.N.1    Tebbutt, P.2    Tyrrell, C.H.3
  • 4
    • 0038281980 scopus 로고
    • A review of the immobilization of enzymes in electropolymerized films
    • Bartlett, P. N. and Cooper, J. M. (1993) A review of the immobilization of enzymes in electropolymerized films. J. Electroanal. Chem. 362, 1-12.
    • (1993) J. Electroanal. Chem. , vol.362 , pp. 1-12
    • Bartlett, P.N.1    Cooper, J.M.2
  • 5
    • 0000299327 scopus 로고
    • An in situ electropoly-o-phenylenediamine/glucose oxiamperometric biosensor for flow-injection determination of glucose in serum
    • Centonze, D., Guerrieri, A., Malitesta, C., Palmisano, F. and Zambonin, P. G. (1992a) An in situ electropoly-o-phenylenediamine/glucose oxiamperometric biosensor for flow-injection determination of glucose in serum. Ann. Chim. (Rome) 82, 219-234.
    • (1992) Ann. Chim. (Rome) , vol.82 , pp. 219-234
    • Centonze, D.1    Guerrieri, A.2    Malitesta, C.3    Palmisano, F.4    Zambonin, P.G.5
  • 6
    • 0000629950 scopus 로고
    • Interference-free glucose sensor based on glucose-oxidase immobilin an overoxidized non-conducting polypyrrole film
    • Centonze, D., Guerrieri, A., Malitesta, C., Palmisano, F. and Zambonin, P. G. (1992b) Interference-free glucose sensor based on glucose-oxidase immobilin an overoxidized non-conducting polypyrrole film. Fresenius J. Anal. Chem. 342, 729-733.
    • (1992) Fresenius J. Anal. Chem. , vol.342 , pp. 729-733
    • Centonze, D.1    Guerrieri, A.2    Malitesta, C.3    Palmisano, F.4    Zambonin, P.G.5
  • 8
    • 0001567901 scopus 로고
    • Electroanalytical/X-ray photoelectron spectroscopy investigation on glucose oxidase adsorbed on platinum
    • De Benedetto, G. E., Malitesta, C. and Zambonin, C. G. (1994) Electroanalytical/X-ray photoelectron spectroscopy investigation on glucose oxidase adsorbed on platinum. J. Chem. Soc. Faraday Trans. 90, 1495-1499.
    • (1994) J. Chem. Soc. Faraday Trans. , vol.90 , pp. 1495-1499
    • De Benedetto, G.E.1    Malitesta, C.2    Zambonin, C.G.3
  • 10
    • 0025762538 scopus 로고
    • Electropolymerized films to prevent interferences and electrode fouling in biosensors
    • Geise, R. J., Adams, J. M., Barone, N. J. and Yacynych, A. M. (1991) Electropolymerized films to prevent interferences and electrode fouling in biosensors. Biosensors & Bioelectronics 6, 151-160.
    • (1991) Biosensors & Bioelectronics , vol.6 , pp. 151-160
    • Geise, R.J.1    Adams, J.M.2    Barone, N.J.3    Yacynych, A.M.4
  • 11
    • 0028841999 scopus 로고
    • Amperometric sensor for choline and acetylcholine based on a platinum electrode modified by a co-crosslinked bienzymic system
    • Guerrieri, A., De Benedetto, G. E., Palmisano, F. and Zambonin, P. G. (1995) Amperometric sensor for choline and acetylcholine based on a platinum electrode modified by a co-crosslinked bienzymic system. Analyst 120, 2731-2736.
    • (1995) Analyst , vol.120 , pp. 2731-2736
    • Guerrieri, A.1    De Benedetto, G.E.2    Palmisano, F.3    Zambonin, P.G.4
  • 12
    • 0002624517 scopus 로고
    • Principles of immobilization of enzymes
    • ed. A. Wiseman. Ellis HorLim. John Wiley & Sons, Part A, Chap. 4
    • Kennedy, J. F. & White, C. A. (1985a). Principles of immobilization of enzymes. In Handbook of Enzyme Biotechnology, ed. A. Wiseman. Ellis HorLim. John Wiley & Sons, Part A, Chap. 4, pp. 147-207.
    • (1985) Handbook of Enzyme Biotechnology , pp. 147-207
    • Kennedy, J.F.1    White, C.A.2
  • 13
    • 0002624517 scopus 로고
    • Data on techniques of enzyme immobilization and bioaffinprocedures
    • ed. A. Wiseman. Ellis Horwood Lim, Chich, England. John Wiley & Sons, Part B, Chap.
    • Kennedy, J. F. & White, C. A. (1985b), Data on techniques of enzyme immobilization and bioaffinprocedures. In Handbook of Enzyme Biotechnol, ed. A. Wiseman. Ellis Horwood Lim, Chich, England. John Wiley & Sons, Part B, Chap., Vol. 4, pp. 380-420.
    • (1985) Handbook of Enzyme Biotechnol , vol.4 , pp. 380-420
    • Kennedy, J.F.1    White, C.A.2
  • 14
    • 0025671780 scopus 로고
    • Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film
    • Malitesta, C., Palmisano, F., Torsi, L. and Zambonin, P. G. (1990) Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film. Anal. Chem. 62, 2735-2740
    • (1990) Anal. Chem. , vol.62 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, P.G.4
  • 15
    • 33847802367 scopus 로고
    • A model for the amperometric enzyme electrode obtained through digital simulation and applied to the immobilized glucose oxidase system
    • Mell, L. D. and Maloy, J. T. (1975) A model for the amperometric enzyme electrode obtained through digital simulation and applied to the immobilized glucose oxidase system. Anal. Chem. 47, 299-307.
    • (1975) Anal. Chem. , vol.47 , pp. 299-307
    • Mell, L.D.1    Maloy, J.T.2
  • 16
    • 0027757187 scopus 로고
    • An interference-free biosensor based on glucose oxidase electrochemically immoin a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling
    • Palmisano, F., Centonze, D., Guerrieri, A. and Zambonin, P. G. (1993) An interference-free biosensor based on glucose oxidase electrochemically immoin a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling. Biosensors & Bioelectronics 8, 393-399.
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 393-399
    • Palmisano, F.1    Centonze, D.2    Guerrieri, A.3    Zambonin, P.G.4
  • 17
    • 0028090182 scopus 로고
    • An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: Determination of lactate in serum by flow injection analysis
    • Palmisano, F., Centonze, D. and Zambonin, P. G. (1994) An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: determination of lactate in serum by flow injection analysis. Biosen& Bioelectronics 9, 471-479.
    • (1994) Biosen& Bioelectronics , vol.9 , pp. 471-479
    • Palmisano, F.1    Centonze, D.2    Zambonin, P.G.3
  • 18
    • 0029275951 scopus 로고
    • Electrosynthesized bilayer polymeric membrane for effective elimination of electroactive interferents in amperometric biosensors
    • Palmisano, F., Guerrieri, A., Quinto, M. and Zambonin, P. G. (1995) Electrosynthesized bilayer polymeric membrane for effective elimination of electroactive interferents in amperometric biosensors. Anal. Chem. 34, 1005-1009.
    • (1995) Anal. Chem. , vol.34 , pp. 1005-1009
    • Palmisano, F.1    Guerrieri, A.2    Quinto, M.3    Zambonin, P.G.4
  • 19
    • 84988073800 scopus 로고
    • Enzyme-modified microelectrodes for in vivo neurochemical measure
    • Pantano, P. and Kuhr, W. G. (1995) Enzyme-modified microelectrodes for in vivo neurochemical measure. Electroanalysis 7, 405-416.
    • (1995) Electroanalysis , vol.7 , pp. 405-416
    • Pantano, P.1    Kuhr, W.G.2
  • 20
    • 0000707017 scopus 로고
    • Electropolymerized 1,2-diaminobenas a means to prevent interferences and fouland to stabilize immobilized enzyme in electrobiosensors
    • Sasso, S. V., Pierce, R. J., Walla, R. and Yacynych, A. M. (1990) Electropolymerized 1,2-diaminobenas a means to prevent interferences and fouland to stabilize immobilized enzyme in electrobiosensors. Anal. Chem. 62, 1111-1117.
    • (1990) Anal. Chem. , vol.62 , pp. 1111-1117
    • Sasso, S.V.1    Pierce, R.J.2    Walla, R.3    Yacynych, A.M.4
  • 21
    • 0026174026 scopus 로고
    • Electrochemical glucose sensor on permselective non-conducting substituted pyrpolymers
    • Schalkhammer, T., Mann-Buxbaum, E., Pittner, F. and Urban, G. (1991) Electrochemical glucose sensor on permselective non-conducting substituted pyrpolymers. Sensors & Actuators B 4, 273-281.
    • (1991) Sensors & Actuators B , vol.4 , pp. 273-281
    • Schalkhammer, T.1    Mann-Buxbaum, E.2    Pittner, F.3    Urban, G.4
  • 22
    • 0026152352 scopus 로고
    • Amperometric substrate deterin flow-injection systems with polypyrenzyme electrodes
    • Schuhmann, W. (1991) Amperometric substrate deterin flow-injection systems with polypyrenzyme electrodes. Sensors & Actuators B 4, 41-49.
    • (1991) Sensors & Actuators B , vol.4 , pp. 41-49
    • Schuhmann, W.1
  • 23
    • 0015217761 scopus 로고
    • The glucose oxidase mechanism: Interpretation of the pH depen
    • Weibel, M. K. and Bright, H. J. (1971) The glucose oxidase mechanism: interpretation of the pH depen. J. Biol. Chem. 246, 2734-2744.
    • (1971) J. Biol. Chem. , vol.246 , pp. 2734-2744
    • Weibel, M.K.1    Bright, H.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.