메뉴 건너뛰기




Volumn 21, Issue 9, 2013, Pages 513-518

Patient-specific instruments for total knee arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPUTER ASSISTED SURGERY; EQUIPMENT; HUMAN; KNEE; KNEE ARTHROPLASTY; METHODOLOGY; PATIENT POSITIONING;

EID: 84885438590     PISSN: 1067151X     EISSN: None     Source Type: Journal    
DOI: 10.5435/JAAOS-21-09-513     Document Type: Article
Times cited : (33)

References (20)
  • 1
    • 2442541105 scopus 로고    scopus 로고
    • Healthrelated quality of life in total hip and total knee arthroplasty: A qualitative and systematic review of the literature
    • Ethgen O, Bruyère O, Richy F, Dardennes C, Reginster JY: Healthrelated quality of life in total hip and total knee arthroplasty: A qualitative and systematic review of the literature. J Bone Joint Surg Am 2004;86(5):963-974.
    • (2004) J Bone Joint Surg Am , vol.86 , Issue.5 , pp. 963-974
    • Ethgen, O.1    Bruyère, O.2    Richy, F.3    Dardennes, C.4    Reginster, J.Y.5
  • 2
    • 67649472540 scopus 로고    scopus 로고
    • Cost-effectiveness of total knee arthroplasty in the United States: Patient risk and hospital volume
    • Losina E, Walensky RP, Kessler CL, et al: Cost-effectiveness of total knee arthroplasty in the United States: Patient risk and hospital volume. Arch Intern Med 2009;169(12):1113-1122.
    • (2009) Arch Intern Med , vol.169 , Issue.12 , pp. 1113-1122
    • Losina, E.1    Walensky, R.P.2    Kessler, C.L.3
  • 3
    • 46749143324 scopus 로고    scopus 로고
    • Orthopaedic surgeon workforce and volume assessment for total hip and knee replacement in the United States: Preparing for an epidemic
    • Iorio R, Robb WJ, Healy WL, et al: Orthopaedic surgeon workforce and volume assessment for total hip and knee replacement in the United States: Preparing for an epidemic. J Bone Joint Surg Am 2008;90(7):1598-1605.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.7 , pp. 1598-1605
    • Iorio, R.1    Robb, W.J.2    Healy, W.L.3
  • 5
    • 77956999796 scopus 로고    scopus 로고
    • Effect of postoperative mechanical axis alignment on the fifteenyear survival of modern, cemented total knee replacements
    • Parratte S, Pagnano MW, Trousdale RT, Berry DJ: Effect of postoperative mechanical axis alignment on the fifteenyear survival of modern, cemented total knee replacements. J Bone Joint Surg Am 2010;92(12):2143-2149.
    • (2010) J Bone Joint Surg Am , vol.92 , Issue.12 , pp. 2143-2149
    • Parratte, S.1    Pagnano, M.W.2    Trousdale, R.T.3    Berry, D.J.4
  • 6
    • 80052857490 scopus 로고    scopus 로고
    • Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: A randomized controlled trial
    • Blakeney WG, Khan RJ, Wall SJ: Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: A randomized controlled trial. J Bone Joint Surg Am 2011;93(15):1377-1384.
    • (2011) J Bone Joint Surg Am , vol.93 , Issue.15 , pp. 1377-1384
    • Blakeney, W.G.1    Khan, R.J.2    Wall, S.J.3
  • 7
    • 37849006470 scopus 로고    scopus 로고
    • Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty: A prospective, randomized study
    • Dutton AQ, Yeo SJ, Yang KY, Lo NN, Chia KU, Chong HC: Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty: A prospective, randomized study. J Bone Joint Surg Am 2008;90(1):2-9.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.1 , pp. 2-9
    • Dutton, A.Q.1    Yeo, S.J.2    Yang, K.Y.3    Lo, N.N.4    Chia, K.U.5    Chong, H.C.6
  • 8
    • 58149354595 scopus 로고    scopus 로고
    • Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients
    • Howell SM, Kuznik K, Hull ML, Siston RA: Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 2008;31(9):857-863.
    • (2008) Orthopedics , vol.31 , Issue.9 , pp. 857-863
    • Howell, S.M.1    Kuznik, K.2    Hull, M.L.3    Siston, R.A.4
  • 9
    • 72349096775 scopus 로고    scopus 로고
    • Initial experience with custom-fit total knee replacement: Intra-operative events and long-leg coronal alignment
    • Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF: Initial experience with custom-fit total knee replacement: Intra-operative events and long-leg coronal alignment. Int Orthop 2009;33(6):1571-1575.
    • (2009) Int Orthop , vol.33 , Issue.6 , pp. 1571-1575
    • Spencer, B.A.1    Mont, M.A.2    McGrath, M.S.3    Boyd, B.4    Mitrick, M.F.5
  • 10
    • 37349078592 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    • Klatt BA, Goyal N, Austin MS, Hozack WJ: Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 2008;23(1):26-29.
    • (2008) J Arthroplasty , vol.23 , Issue.1 , pp. 26-29
    • Klatt, B.A.1    Goyal, N.2    Austin, M.S.3    Hozack, W.J.4
  • 11
    • 84884533398 scopus 로고    scopus 로고
    • Evaluation of the accuracy of a patientspecific instrumentation by navigation
    • Jun. 27 Epub ahead of print
    • Conteduca F, Iorio R, Mazza D, et al: Evaluation of the accuracy of a patientspecific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc 2012; Jun. 27 [Epub ahead of print].
    • (2012) Knee Surg Sports Traumatol Arthrosc
    • Conteduca, F.1    Iorio, R.2    Mazza, D.3
  • 12
    • 83555176169 scopus 로고    scopus 로고
    • The value of patient-matched instrumentation in total knee arthroplasty
    • Noble JW Jr, Moore CA, Liu N: The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 2012;27(1):153-155.
    • (2012) J Arthroplasty , vol.27 , Issue.1 , pp. 153-155
    • Noble Jr., J.W.1    Moore, C.A.2    Liu, N.3
  • 13
    • 84865102501 scopus 로고    scopus 로고
    • Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA
    • Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr: Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 2012;470(1):99-107.
    • (2012) Clin Orthop Relat Res , vol.470 , Issue.1 , pp. 99-107
    • Ng, V.Y.1    DeClaire, J.H.2    Berend, K.R.3    Gulick, B.C.4    Lombardi Jr., A.V.5
  • 16
    • 80052617000 scopus 로고    scopus 로고
    • Analysis of procedure-related costs and proposed benefits of using patientspecific approach in total knee arthroplasty
    • Watters TS, Mather RC III, Browne JA, Berend KR, Lombardi AV Jr, Bolognesi MP: Analysis of procedure-related costs and proposed benefits of using patientspecific approach in total knee arthroplasty. J Surg Orthop Adv 2011;20(2):112-116.
    • (2011) J Surg Orthop Adv , vol.20 , Issue.2 , pp. 112-116
    • Watters, T.S.1    Mather III, R.C.2    Browne, J.A.3    Berend, K.R.4    Lombardi Jr., A.V.5    Bolognesi, M.P.6
  • 17
    • 84856954337 scopus 로고    scopus 로고
    • Are patient-specific cutting blocks costeffective for total knee arthroplasty?
    • Nunley RM, Ellison BS, Ruh EL, et al: Are patient-specific cutting blocks costeffective for total knee arthroplasty? Clin Orthop Relat Res 2012;470(3):889-894.
    • (2012) Clin Orthop Relat Res , vol.470 , Issue.3 , pp. 889-894
    • Nunley, R.M.1    Ellison, B.S.2    Ruh, E.L.3
  • 18
    • 84871613896 scopus 로고    scopus 로고
    • Patient-specific total knee arthroplasty required frequent surgeondirected changes
    • Stronach BM, Pelt CE, Erickson J, Peters CL: Patient-specific total knee arthroplasty required frequent surgeondirected changes. Clin Orthop Relat Res 2013;471(1):169-174.
    • (2013) Clin Orthop Relat Res , vol.471 , Issue.1 , pp. 169-174
    • Stronach, B.M.1    Pelt, C.E.2    Erickson, J.3    Peters, C.L.4
  • 19
    • 73349097581 scopus 로고    scopus 로고
    • Value of preoperative templating for primary total knee arthroplasty
    • Del Gaizo D, Soileau ES, Lachiewicz PF: Value of preoperative templating for primary total knee arthroplasty. J Knee Surg 2009;22(4):284-293.
    • (2009) J Knee Surg , vol.22 , Issue.4 , pp. 284-293
    • Del Gaizo, D.1    Soileau, E.S.2    Lachiewicz, P.F.3
  • 20
    • 84855562280 scopus 로고    scopus 로고
    • Cost-effectiveness analysis of custom total knee cutting blocks
    • Slover JD, Rubash HE, Malchau H, Bosco JA: Cost-effectiveness analysis of custom total knee cutting blocks. J Arthroplasty 2012;27(2):180-185.
    • (2012) J Arthroplasty , vol.27 , Issue.2 , pp. 180-185
    • Slover, J.D.1    Rubash, H.E.2    Malchau, H.3    Bosco, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.