메뉴 건너뛰기




Volumn 34, Issue 12, 2009, Pages 1325-1329

Computer navigation in balloon kyphoplasty reduces the intraoperative radiation exposure

Author keywords

Balloon kyphoplasty; Computer navigation; DAP; Radiation dose

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER SYSTEM; CONTROLLED STUDY; FEMALE; FLUOROSCOPY; FRAGILITY FRACTURE; HUMAN; INTRAOPERATIVE PERIOD; KYPHOPLASTY; LUMBAR SPINE; MALE; OPERATION DURATION; PRIORITY JOURNAL; RADIATION EXPOSURE; SPINE FRACTURE; SPINE SURGERY; SURGEON; SURGICAL TECHNIQUE; THORACIC SPINE;

EID: 67651159010     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e3181a18529     Document Type: Article
Times cited : (61)

References (20)
  • 2
    • 1442302381 scopus 로고    scopus 로고
    • Kyphoplastie und Vertebroplastie bei Frakturen im hohen Lebensalter Aufwand und Ergebnisse
    • DOI 10.1007/s00104-003-0748-x
    • Meeder PJ, DaFonseca K, Hillmeier J, et al. Kyphoplasty and vertebroplasty in fractures in the elderly: effort and effect [in Germany]. Chirurg 2003;74: 994-999 (Pubitemid 38270111)
    • (2003) Chirurg , vol.74 , Issue.11 , pp. 994-999
    • Meeder, P.-J.1    Dafonseca, K.2    Hillmeier, J.3    Grafe, I.4    Noeldge, G.5    Kasperk, C.6
  • 5
    • 33846471867 scopus 로고    scopus 로고
    • Patient radiation doses from adult and pediatric CT
    • DOI 10.2214/AJR.06.0101
    • Huda W, Vance A. Patient radiation doses from adult and pediatric CT. AJR 2007;188:540-546 (Pubitemid 46170754)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.2 , pp. 540-546
    • Huda, W.1    Vance, A.2
  • 7
    • 0037624000 scopus 로고    scopus 로고
    • Radiation dose reduction to medical staff during vertebroplasty: A review of techniques and methods to mitigate occupational dose
    • DOI 10.1097/00007632-200307150-00024
    • Kruger R, Faciszewski T. Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose. Spine 2003;28:1608-1613 (Pubitemid 36877099)
    • (2003) Spine , vol.28 , Issue.14 , pp. 1608-1613
    • Kruger, R.1    Faciszewski, T.2
  • 8
    • 23944475576 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: A prospective study
    • DOI 10.1097/01.brs.0000174121.48306.16
    • Harstall R, Heini PF, Mini RL, et al. Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine 2005;30:1893-1898 (Pubitemid 41208837)
    • (2005) Spine , vol.30 , Issue.16 , pp. 1893-1898
    • Harstall, R.1    Heini, P.F.2    Mini, R.L.3    Orler, R.4
  • 11
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion: Fluoroscopic method versus computer-assisted surgery
    • DOI 10.1097/00007632-199905150-00009
    • Slomczykowski M, Roberto M, Schneeberger P, et al. Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery. Spine 1999;24:975-82; discussion 83. (Pubitemid 29222617)
    • (1999) Spine , vol.24 , Issue.10 , pp. 975-983
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3    Ozdoba, C.4    Vock, P.5
  • 13
    • 33750571887 scopus 로고    scopus 로고
    • Balloon kyphoplasty and vertebroplasty for vertebral compression fractures: A comparative systematic review of efficacy and safety
    • DOI 10.1097/01.brs.0000244639.71656.7d, PII 0000763220061101000019
    • Taylor RS, Taylor RJ, Fritzell P. Balloon kyphoplasty and vertebroplasty for vertebral compression fractures: a comparative systematic review of efficacy and safety. Spine 2006;31:2747-2755 (Pubitemid 44673389)
    • (2006) Spine , vol.31 , Issue.23 , pp. 2747-2755
    • Taylor, R.S.1    Taylor, R.J.2    Fritzell, P.3
  • 14
    • 13844280343 scopus 로고    scopus 로고
    • Patient radiation dose from vertebroplasty and kyphoplasty
    • Miller DL. Patient radiation dose from vertebroplasty and kyphoplasty. Radiology 2005;234:970-971
    • (2005) Radiology , vol.234 , pp. 970-971
    • Miller, D.L.1
  • 16
    • 0026712220 scopus 로고
    • Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product
    • Le Heron JC. Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product. Phys Med Biol 1992;37:2117-2126
    • (1992) Phys Med Biol , vol.37 , pp. 2117-2126
    • Le Heron, J.C.1
  • 17
    • 39849084917 scopus 로고    scopus 로고
    • Learning curve in navigated total knee replacement: A multi-centre study comparing experienced and beginner centres
    • Jenny JY, Miehlke RK, Giurea A. Learning curve in navigated total knee replacement: a multi-centre study comparing experienced and beginner centres. Knee 2008;15:80-84
    • (2008) Knee , vol.15 , pp. 80-84
    • Jenny, J.Y.1    Miehlke, R.K.2    Giurea, A.3
  • 19
    • 36049010038 scopus 로고    scopus 로고
    • The cost-effectiveness of computer-assisted navigation in total knee arthroplasty
    • DOI 10.2106/JBJS.F.01109
    • Novak EJ, Silverstein MD, Bozic KJ. The cost-effectiveness of computer-assisted navigation in total knee arthroplasty. J Bone Joint Surg Am 2007; 89:2389-2397 (Pubitemid 350086327)
    • (2007) Journal of Bone and Joint Surgery - Series a , vol.89 , Issue.11 , pp. 2389-2397
    • Novak, E.J.1    Silverstein, M.D.2    Bozic, K.J.3
  • 20
    • 46749143325 scopus 로고    scopus 로고
    • Impact of hospital volume on the economic value of computer navigation for total knee replacement
    • Slover JD, Tosteson AN, Bozic KJ, et al. Impact of hospital volume on the economic value of computer navigation for total knee replacement. J Bone Joint Surg Am 2008;90:1492-1500
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1492-1500
    • Slover, J.D.1    Tosteson, A.N.2    Bozic, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.