메뉴 건너뛰기




Volumn 37, Issue 3, 2010, Pages 1273-1284

A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy

Author keywords

2D to 3D registration; Genetic algorithm; Knee kinematics; X ray fluoroscopy

Indexed keywords

FLUORESCENT SCREENS; GENETIC ALGORITHMS; JOINTS (ANATOMY); KINEMATICS; MEASUREMENT ERRORS;

EID: 77749292316     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3301596     Document Type: Article
Times cited : (65)

References (42)
  • 1
    • 0033119558 scopus 로고    scopus 로고
    • The importance of quadriceps and hamstring muscle loading on knee kinematics and in-situ forces in the ACL
    • DOI 10.1016/S0021-9290(98)00181-X, PII S002192909800181X
    • G. Li, T. W. Rudy, M. Sakane, A. Kanamori, C. B. Ma, and S. L. Woo, " The importance of quadriceps and hamstring muscle loading on knee kinematics and in-situ forces in the ACL.," J. Biomech. JBMCB5 0021-9290 32, 395-400 (1999). 10.1016/S0021-9290(98)00181-X (Pubitemid 29156705)
    • (1999) Journal of Biomechanics , vol.32 , Issue.4 , pp. 395-400
    • Li, G.1    Rudy, T.W.2    Sakane, M.3    Kanamori, A.4    Ma, C.B.5    Woo, S.L.-Y.6
  • 2
    • 33750610455 scopus 로고    scopus 로고
    • Role of knee kinematics and kinetics on performance and disability in people with medial compartment knee osteoarthritis
    • DOI 10.1016/j.clinbiomech.2006.06.010, PII S0268003306001343
    • M. R. Maly, P. A. Costigan, and S. J. Olney, " Role of knee kinematics and kinetics on performance and disability in people with medial compartment knee osteoarthritis.," Clin. Biomech. (Bristol, Avon) ZZZZZZ 0268-0033 21, 1051-1059 (2006). 10.1016/j.clinbiomech.2006.06.010 (Pubitemid 44691991)
    • (2006) Clinical Biomechanics , vol.21 , Issue.10 , pp. 1051-1059
    • Maly, M.R.1    Costigan, P.A.2    Olney, S.J.3
  • 3
    • 0034107932 scopus 로고    scopus 로고
    • Biomechanical analysis of a double-bundle posterior cruciate ligament reconstruction
    • ZZZZZZ 0363-5465.
    • C. D. Harner, M. A. Janaushek, A. Kanamori, M. Yagi, T. M. Vogrin, and S. L. Woo, " Biomechanical analysis of a double-bundle posterior cruciate ligament reconstruction.," Am. J. Sports Med. ZZZZZZ 0363-5465 28, 144-151 (2000).
    • (2000) Am. J. Sports Med. , vol.28 , pp. 144-151
    • Harner, C.D.1    Janaushek, M.A.2    Kanamori, A.3    Yagi, M.4    Vogrin, T.M.5    Woo, S.L.6
  • 4
    • 0037243208 scopus 로고    scopus 로고
    • Three-dimensional tibiofemoral kinematics of the anterior cruciate ligament-deficient and reconstructed knee during walking
    • ZZZZZZ 0363-5465.
    • A. D. Georgoulis, A. Papadonikolakis, C. D. Papageorgiou, A. Mitsou, and N. Stergiou, " Three-dimensional tibiofemoral kinematics of the anterior cruciate ligament-deficient and reconstructed knee during walking.," Am. J. Sports Med. ZZZZZZ 0363-5465 31, 75-79 (2003).
    • (2003) Am. J. Sports Med. , vol.31 , pp. 75-79
    • Georgoulis, A.D.1    Papadonikolakis, A.2    Papageorgiou, C.D.3    Mitsou, A.4    Stergiou, N.5
  • 5
    • 0029859424 scopus 로고    scopus 로고
    • In vivo knee kinematics derived using an inverse perspective technique
    • CORTBR 0009-921X,. 10.1097/00003086-199610000-00015
    • D. A. Dennis, R. D. Komistek, W. A. Hoff, and S. M. Gabriel, " In vivo knee kinematics derived using an inverse perspective technique.," Clin. Orthop. Relat. Res. CORTBR 0009-921X 331, 107-117 (1996). 10.1097/00003086-199610000-00015
    • (1996) Clin. Orthop. Relat. Res. , vol.331 , pp. 107-117
    • Dennis, D.A.1    Komistek, R.D.2    Hoff, W.A.3    Gabriel, S.M.4
  • 6
    • 0030449939 scopus 로고    scopus 로고
    • Lines of action and moment arms of the major force-bearing structures crossing the human knee joint: Comparison between theory and experiment
    • JOANAY 0021-8782.
    • T. W. Lu and J. J. O'Connor, " Lines of action and moment arms of the major force-bearing structures crossing the human knee joint: Comparison between theory and experiment.," J. Anat. JOANAY 0021-8782 189, 575-585 (1996).
    • (1996) J. Anat. , vol.189 , pp. 575-585
    • Lu, T.W.1    O'Connor, J.J.2
  • 7
    • 33646114076 scopus 로고    scopus 로고
    • Influence of functional bracing on the kinetics of anterior cruciate ligament-injured knees during level walking
    • ZZZZZZ 0268-0033,. 10.1016/j.clinbiomech.2005.12.017
    • T. -W. Lu, H. -C. Lin, and H. -C. Hsu, " Influence of functional bracing on the kinetics of anterior cruciate ligament-injured knees during level walking.," Clin. Biomech. (Bristol, Avon) ZZZZZZ 0268-0033 21, 517-524 (2006). 10.1016/j.clinbiomech.2005.12.017
    • (2006) Clin. Biomech. (Bristol, Avon) , vol.21 , pp. 517-524
    • Lu, T.-W.1    Lin, H.-C.2    Hsu, H.-C.3
  • 8
    • 28344449194 scopus 로고    scopus 로고
    • Comparisons of the joint moments between leading and trailing limb in young adults when stepping over obstacles
    • DOI 10.1016/j.gaitpost.2004.12.001, PII S0966636204002711
    • H. -L. Chen and T. -W. Lu, " Comparisons of the joint moments between leading and trailing limb in young adults when stepping over obstacles.," Gait and Posture GAPOFK 0966-6362 23, 69-77 (2006). 10.1016/j.gaitpost.2004.12.001 (Pubitemid 41718925)
    • (2006) Gait and Posture , vol.23 , Issue.1 , pp. 69-77
    • Chen, H.-L.1    Lu, T.-W.2
  • 9
    • 34247123303 scopus 로고    scopus 로고
    • Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion
    • DOI 10.1016/j.jbiomech.2006.06.017, PII S0021929006002454
    • P. M. Mills, S. Morrison, D. G. Lloyd, and R. S. Barrett, " Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion.," J. Biomech. JBMCB5 0021-9290 40, 1504-1511 (2007). 10.1016/j.jbiomech.2006.06.017 (Pubitemid 46601445)
    • (2007) Journal of Biomechanics , vol.40 , Issue.7 , pp. 1504-1511
    • Mills, P.M.1    Morrison, S.2    Lloyd, D.G.3    Barrett, R.S.4
  • 10
    • 33646124249 scopus 로고    scopus 로고
    • Comparisons of the lower limb kinematics between young and older adults when crossing obstacles of different heights
    • GAPOFK 0966-6362,. 10.1016/j.gaitpost.2005.06.005
    • T. -W. Lu, H. -L. Chen, and S. -C. Chen, " Comparisons of the lower limb kinematics between young and older adults when crossing obstacles of different heights.," Gait and Posture GAPOFK 0966-6362 23, 471-479 (2006). 10.1016/j.gaitpost.2005.06.005
    • (2006) Gait and Posture , vol.23 , pp. 471-479
    • Lu, T.-W.1    Chen, H.-L.2    Chen, S.-C.3
  • 11
    • 0026848920 scopus 로고
    • Three-dimensional kinematics of the human knee during walking
    • JBMCB5 0021-9290,. 10.1016/0021-9290(92)90254-X
    • M. A. Lafortune, P. R. Cavanagh, H. J. Sommer III, and A. Kalenak, " Three-dimensional kinematics of the human knee during walking.," J. Biomech. JBMCB5 0021-9290 25, 347-357 (1992). 10.1016/0021-9290(92)90254-X
    • (1992) J. Biomech. , vol.25 , pp. 347-357
    • Lafortune, M.A.1    Cavanagh, P.R.2    Iii, J.S.H.3    Kalenak, A.4
  • 12
    • 0033081306 scopus 로고    scopus 로고
    • Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints
    • DOI 10.1016/S0021-9290(98)00158-4, PII S0021929098001584
    • T. W. Lu and J. J. O'Connor, " Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints.," J. Biomech. JBMCB5 0021-9290 32, 129-134 (1999). 10.1016/S0021-9290(98)00158-4 (Pubitemid 29062275)
    • (1999) Journal of Biomechanics , vol.32 , Issue.2 , pp. 129-134
    • Lu, T.-W.1    O'Connor, J.J.2
  • 13
    • 10444220215 scopus 로고    scopus 로고
    • In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
    • DOI 10.1016/j.jbiomech.2004.02.042, PII S002192900400082X
    • D. A. Dennis, M. R. Mahfouz, R. D. Komistek, and W. A. Hoff, " In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.," J. Biomech. JBMCB5 0021-9290 38, 241-253 (2005). 10.1016/j.jbiomech.2004.02.042 (Pubitemid 39642944)
    • (2005) Journal of Biomechanics , vol.38 , Issue.2 , pp. 241-253
    • Dennis, D.A.1    Mahfouz, M.R.2    Komistek, R.D.3    Hoff, W.4
  • 14
    • 0344012667 scopus 로고    scopus 로고
    • A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
    • ITMID4 0278-0062,. 10.1109/TMI.2003.820027
    • M. R. Mahfouz, W. A. Hoff, R. D. Komistek, and D. A. Dennis, " A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.," IEEE Trans. Med. Imaging ITMID4 0278-0062 22, 1561-1574 (2003). 10.1109/TMI.2003.820027
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 1561-1574
    • Mahfouz, M.R.1    Hoff, W.A.2    Komistek, R.D.3    Dennis, D.A.4
  • 15
    • 0032189583 scopus 로고    scopus 로고
    • Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy
    • DOI 10.1016/S0268-0033(98)00009-6, PII S0268003398000096
    • W. A. Hoff, R. D. Komistek, D. A. Dennis, S. M. Gabriel, and S. A. Walker, " Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.," Clin. Biomech. (Bristol, Avon) ZZZZZZ 0268-0033 13, 455-472 (1998). 10.1016/S0268-0033(98) 00009-6 (Pubitemid 28442179)
    • (1998) Clinical Biomechanics , vol.13 , Issue.7 , pp. 455-472
    • Hoff, W.A.1    Komistek, R.D.2    Dennis, D.A.3    Gabriel, S.M.4    Walker, S.A.5
  • 16
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • DOI 10.1109/10.495283
    • S. A. Banks and W. A. Hodge, " Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.," IEEE Trans. Biomed. Eng. IEBEAX 0018-9294 43, 638-649 (1996). 10.1109/10.495283 (Pubitemid 26158677)
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , Issue.6 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 17
    • 0033201375 scopus 로고    scopus 로고
    • Model-based method for the reconstruction of total knee replacement kinematics
    • DOI 10.1109/42.811310
    • S. Zuffi, A. Leardini, F. Catani, S. Fantozzi, and A. Cappello, " A model-based method for the reconstruction of total knee replacement kinematics.," IEEE Trans. Med. Imaging ITMID4 0278-0062 18, 981-991 (1999). 10.1109/42.811310 (Pubitemid 32211113)
    • (1999) IEEE Transactions on Medical Imaging , vol.18 , Issue.10 , pp. 981-991
    • Zuffi, S.1    Leardini, A.2    Catani, F.3    Fantozzi, S.4    Cappello, A.5
  • 18
    • 20544441741 scopus 로고    scopus 로고
    • Kinematics of mobile-bearing total knee arthroplasty
    • ZZZZZZ 0065-6895.
    • D. A. Dennis and R. D. Komistek, " Kinematics of mobile-bearing total knee arthroplasty.," Instr Course Lect ZZZZZZ 0065-6895 54, 207-220 (2005).
    • (2005) Instr Course Lect , vol.54 , pp. 207-220
    • Dennis, D.A.1    Komistek, R.D.2
  • 19
    • 2542471541 scopus 로고    scopus 로고
    • Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy
    • ITMID4 0278-0062,. 10.1109/TMI.2004.826051
    • T. Yamazaki, T. Watanabe, Y. Nakajima, K. Sugamoto, T. Tomita, H. Yoshikawa, and S. Tamura, " Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy.," IEEE Trans. Med. Imaging ITMID4 0278-0062 23, 602-612 (2004). 10.1109/TMI.2004.826051
    • (2004) IEEE Trans. Med. Imaging , vol.23 , pp. 602-612
    • Yamazaki, T.1    Watanabe, T.2    Nakajima, Y.3    Sugamoto, K.4    Tomita, T.5    Yoshikawa, H.6    Tamura, S.7
  • 20
    • 26444461541 scopus 로고    scopus 로고
    • Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements
    • DOI 10.1007/s00167-004-0565-x
    • S. A. Banks, B. J. Fregly, F. Boniforti, C. Reinschmidt, and S. Romagnoli, " Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements.," Knee Surg. Sports Traumatol. Arthrosc ZZZZZZ 0942-2056 13, 551-556 (2005). 10.1007/s00167-004-0565-x (Pubitemid 41426223)
    • (2005) Knee Surgery, Sports Traumatology, Arthroscopy , vol.13 , Issue.7 , pp. 551-556
    • Banks, S.A.1    Fregly, B.J.2    Boniforti, F.3    Reinschmidt, C.4    Romagnoli, S.5
  • 21
    • 0037692766 scopus 로고    scopus 로고
    • A new model-based RSA method validated using CAD models and models from reversed engineering
    • DOI 10.1016/S0021-9290(03)00002-2
    • B. L. Kaptein, E. R. Valstar, B. C. Stoel, P. M. Rozing, and J. H. C. Reiber, " A new model-based RSA method validated using CAD models and models from reversed engineering.," J. Biomech. JBMCB5 0021-9290 36, 873-882 (2003). 10.1016/S0021-9290(03)00002-2 (Pubitemid 36555384)
    • (2003) Journal of Biomechanics , vol.36 , Issue.6 , pp. 873-882
    • Kaptein, B.L.1    Valstar, E.R.2    Stoel, B.C.3    Rozing, P.M.4    Reiber, J.H.C.5
  • 22
    • 0037396234 scopus 로고    scopus 로고
    • In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: Application to canine ACL deficiency
    • DOI 10.1115/1.1559896
    • S. Tashman and W. Anderst, " In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: Application to canine ACL deficiency.," J. Biomech. Eng. JBENDY 0148-0731 125, 238-245 (2003). 10.1115/1.1559896 (Pubitemid 36506138)
    • (2003) Journal of Biomechanical Engineering , vol.125 , Issue.2 , pp. 238-245
    • Tashman, S.1    Anderst, W.2
  • 24
    • 33845963825 scopus 로고    scopus 로고
    • Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images
    • DOI 10.1118/1.2401661
    • W. Birkfellner, M. Figl, J. Kettenbach, J. Hummel, P. Homolka, R. Schernthaner, T. Nau, and H. Bergmann, " Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images.," Med. Phys. MPHYA6 0094-2405 34, 246 (2007). 10.1118/1.2401661 (Pubitemid 46035247)
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 246-255
    • Birkfellner, W.1    Figl, M.2    Kettenbach, J.3    Hummel, J.4    Homolka, P.5    Schernthaner, R.6    Nau, T.7    Bergmann, H.8
  • 25
    • 0038278916 scopus 로고    scopus 로고
    • Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer
    • ITMID4 0278-0062,. 10.1109/TMI.2003.809078
    • B. Fei, J. L. Duerk, D. T. Boll, J. S. Lewin, and D. L. Wilson, " Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer.," IEEE Trans. Med. Imaging ITMID4 0278-0062 22, 515-525 (2003). 10.1109/TMI.2003.809078
    • (2003) IEEE Trans. Med. Imaging , vol.22 , pp. 515-525
    • Fei, B.1    Duerk, J.L.2    Boll, D.T.3    Lewin, J.S.4    Wilson, D.L.5
  • 26
    • 0032900418 scopus 로고    scopus 로고
    • Motion correction in fMRI via registration of individual slices into an anatomical volume
    • DOI 10.1002/(SICI)1522-2594(199905)41:5<964::AID-MRM16>3.0.CO;2-D
    • B. Kim, J. L. Boes, P. H. Bland, T. L. Chenevert, and C. R. Meyer, " Motion correction in fMRI via registration of individual slices into an anatomical volume.," Magn. Reson. Med. MRMEEN 0740-3194 41, 964-972 (1999). 10.1002/(SICI)1522-2594(199905)41:5<964::AID-MRM16>3.0.CO;2-D (Pubitemid 29211140)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.5 , pp. 964-972
    • Kim, B.1    Boes, J.L.2    Bland, P.H.3    Chenevert, T.L.4    Meyer, C.R.5
  • 27
    • 0034245360 scopus 로고    scopus 로고
    • Automatic registration of postmortem brain slices to MRI reference volume
    • DOI 10.1109/23.873023
    • T. S. Kim, M. Singh, W. Sungkarat, C. Zarow, and H. Chui, " Automatic registration of postmortem brain slices to MRI reference volume.," IEEE Trans. Nucl. Sci. IETNAE 0018-9499 47, 1607-1613 (2000). 10.1109/23.873023 (Pubitemid 30940709)
    • (2000) IEEE Transactions on Nuclear Science , vol.47 , Issue.4 , pp. 1607-1613
    • Kim, T.-S.1    Singh, M.2    Sungkarat, W.3    Zarow, C.4    Chui, H.5
  • 28
    • 84907108200 scopus 로고
    • Mapping between MR brain images and a voxel model
    • ZZZZZZ 0307-7640.
    • J. Zhengping and P. H. Mowforth, " Mapping between MR brain images and a voxel model.," Med. Inf. (Lond) ZZZZZZ 0307-7640 16, 183-193 (1991).
    • (1991) Med. Inf. (Lond) , vol.16 , pp. 183-193
    • Zhengping, J.1    Mowforth, P.H.2
  • 29
    • 0038066801 scopus 로고    scopus 로고
    • In vivo fluoroscopic analysis of the normal human knee
    • CORTBR 0009-921X,. 10.1097/01.blo.0000062384.79828.3b
    • R. D. Komistek, D. A. Dennis, and M. Mahfouz, " In vivo fluoroscopic analysis of the normal human knee.," Clin. Orthop. Relat. Res. CORTBR 0009-921X 410, 69-81 (2003). 10.1097/01.blo.0000062384.79828.3b
    • (2003) Clin. Orthop. Relat. Res. , vol.410 , pp. 69-81
    • Komistek, R.D.1    Dennis, D.A.2    Mahfouz, M.3
  • 30
    • 0038206681 scopus 로고    scopus 로고
    • Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions
    • ZZZZZZ 0942-2056.
    • I. Kanisawa, A. Z. Banks, S. A. Banks, H. Moriya, and A. Tsuchiya, " Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions.," Knee Surg. Sports Traumatol. Arthrosc ZZZZZZ 0942-2056 11, 16-22 (2003).
    • (2003) Knee Surg. Sports Traumatol. Arthrosc , vol.11 , pp. 16-22
    • Kanisawa, I.1    Banks, A.Z.2    Banks, S.A.3    Moriya, H.4    Tsuchiya, A.5
  • 31
    • 33646437820 scopus 로고    scopus 로고
    • Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement
    • MPHYA6 0094-2405,. 10.1118/1.2192621
    • R. Munbodh, D. A. Jaffray, D. J. Moseley, Z. Chen, J. P. S. Knisely, P. Cathier, and J. S. Duncan, " Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.," Med. Phys. MPHYA6 0094-2405 33, 1398-1411 (2006). 10.1118/1.2192621
    • (2006) Med. Phys. , vol.33 , pp. 1398-1411
    • Munbodh, R.1    Jaffray, D.A.2    Moseley, D.J.3    Chen, Z.4    Knisely, J.P.S.5    Cathier, P.6    Duncan, J.S.7
  • 32
    • 0027996228 scopus 로고
    • A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs
    • DOI 10.1118/1.597276
    • L. Lemieux, R. Jagoe, D. R. Fish, N. D. Kitchen, and D. G. Thomas, " A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs.," Med. Phys. MPHYA6 0094-2405 21, 1749-1760 (1994). 10.1118/1.597276 (Pubitemid 24356296)
    • (1994) Medical Physics , vol.21 , Issue.11 , pp. 1749-1760
    • Lemieux, L.1    Jagoe, R.2    Fish, D.R.3    Kitchen, N.D.4    Thomas, D.G.T.5
  • 34
    • 0032129157 scopus 로고    scopus 로고
    • A comparison of similarity measures for use in 2-D-3-D medical image registration
    • PII S0278006298080483
    • G. P. Penney, J. Weese, J. A. Little, P. Desmedt, D. L. Hill, D. J. Hawkes, G. P. Penney, J. Weese, J. A. Little, P. Desmedt, D. L. Hill, and D. J. Hawkes, " A comparison of similarity measures for use in 2-D-3-D medical image registration.," IEEE Trans. Med. Imaging ITMID4 0278-0062 17, 586-595 (1998). 10.1109/42.730403 (Pubitemid 128747714)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.4 , pp. 586-595
    • Penney, G.P.1    Weese, J.2    Little, J.A.3    Desmedt, P.4    Hill, D.L.G.5    Hawkes, D.J.6
  • 35
    • 0034971324 scopus 로고    scopus 로고
    • Validation of a two-to three-dimensional registration algorithm for aligning preoperative CT images and intraoperative fluoroscopy images
    • MPHYA6 0094-2405,. 10.1118/1.1373400
    • G. P. Penney, P. G. Batchelor, D. L. Hill, D. J. Hawkes, J. Weese, G. P. Penney, P. G. Batchelor, D. L. Hill, D. J. Hawkes, and J. Weese, " Validation of a two-to three-dimensional registration algorithm for aligning preoperative CT images and intraoperative fluoroscopy images.," Med. Phys. MPHYA6 0094-2405 28, 1024-1032 (2001). 10.1118/1.1373400
    • (2001) Med. Phys. , vol.28 , pp. 1024-1032
    • Penney, G.P.1    Batchelor, P.G.2    Hill, D.L.3    Hawkes, D.J.4    Weese, J.5    Penney, G.P.6    Batchelor, P.G.7    Hill, D.L.8    Hawkes, D.J.9    Weese, J.10
  • 36
    • 0029256739 scopus 로고
    • A video fluoroscopy method for optical distortion correction and measurement of knee-joint kinematics
    • ZZZZZZ 0268-0033,. 10.1016/0268-0033(95)92044-M
    • V. Baltzopoulos, " A video fluoroscopy method for optical distortion correction and measurement of knee-joint kinematics.," Clin. Biomech. (Bristol, Avon) ZZZZZZ 0268-0033 10, 85-92 (1995). 10.1016/0268-0033(95)92044-M
    • (1995) Clin. Biomech. (Bristol, Avon) , vol.10 , pp. 85-92
    • Baltzopoulos, V.1
  • 37
    • 0022808786 scopus 로고
    • A computational approach to edge detection
    • ITPIDJ 0162-8828,. 10.1109/TPAMI.1986.4767851
    • J. Canny, " A computational approach to edge detection.," IEEE Trans. Pattern Anal. Mach. Intell. ITPIDJ 0162-8828 PAMI-8, 679-698 (1986). 10.1109/TPAMI.1986.4767851
    • (1986) IEEE Trans. Pattern Anal. Mach. Intell. , vol.PAMI-8 , pp. 679-698
    • Canny, J.1
  • 39
    • 0027640931 scopus 로고
    • Genetic algorithms: Principles of natural selection applied to computation
    • SCIEAS 0036-8075,. 10.1126/science.8346439
    • S. Forrest, " Genetic algorithms: Principles of natural selection applied to computation.," Science SCIEAS 0036-8075 261, 872-878 (1993). 10.1126/science.8346439
    • (1993) Science , vol.261 , pp. 872-878
    • Forrest, S.1
  • 40
    • 53049090828 scopus 로고    scopus 로고
    • In vivo three-dimensional kinematics of the normal knee during active extension under unloaded and loaded conditions using single-plane fluoroscopy
    • MEPHEO 1350-4533,. 10.1016/j.medengphy.2008.03.001
    • T. -W. Lu, T. -Y. Tsai, M. -Y. Kuo, H. -C. Hsu, and H. -L. Chen, " In vivo three-dimensional kinematics of the normal knee during active extension under unloaded and loaded conditions using single-plane fluoroscopy.," Med. Eng. Phys. MEPHEO 1350-4533 30, 1004-1012 (2008). 10.1016/j.medengphy.2008.03. 001
    • (2008) Med. Eng. Phys. , vol.30 , pp. 1004-1012
    • Lu, T.-W.1    Tsai, T.-Y.2    Kuo, M.-Y.3    Hsu, H.-C.4    Chen, H.-L.5
  • 41
    • 0026821209 scopus 로고
    • A method for registration of 3-D shapes
    • ITPIDJ 0162-8828,. 10.1109/34.121791
    • P. J. Besl and N. D. Mckay, " A method for registration of 3-D shapes.," IEEE Trans. Pattern Anal. Mach. Intell. ITPIDJ 0162-8828 14, 239-256 (1992). 10.1109/34.121791
    • (1992) IEEE Trans. Pattern Anal. Mach. Intell. , vol.14 , pp. 239-256
    • Besl, P.J.1    McKay, N.D.2
  • 42
    • 23644455465 scopus 로고    scopus 로고
    • Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy
    • DOI 10.1115/1.1933949
    • B. J. Fregly, H. A. Rahman, and S. A. Banks, " Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.," J. Biomech. Eng. JBENDY 0148-0731 127, 692-699 (2005). 10.1115/1.1933949 (Pubitemid 41116929)
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.4 , pp. 692-699
    • Fregly, B.J.1    Rahman, H.A.2    Banks, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.