메뉴 건너뛰기




Volumn 14, Issue 3, 2013, Pages 329-335

Improved rat spinal cord injury model using spinal cord compression by percutaneous method

Author keywords

Balloon compression; Laminectomy free; Magnetic resonance imaging; Percutaneous spinal cord injury; Rat

Indexed keywords

ANIMAL; ARTICLE; BALLOON COMPRESSION; BALLOON EMBOLECTOMY; DISEASE MODEL; EVALUATION STUDY; LAMINECTOMY-FREE; MALE; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PERCUTANEOUS SPINAL CORD INJURY; RAT; SPINAL CORD COMPRESSION; SPRAGUE DAWLEY RAT;

EID: 84885352813     PISSN: 1229845X     EISSN: 1976555X     Source Type: Journal    
DOI: 10.4142/jvs.2013.14.3.329     Document Type: Article
Times cited : (11)

References (29)
  • 2
    • 0028919411 scopus 로고
    • A sensitive and reliable locomotor rating scale for open field testing in rats
    • Basso DM, Beattie MS, Bresnahan JC. A sensitive and reliable locomotor rating scale for open field testing in rats. J Neurotrauma 1995, 12, 1-21.
    • (1995) J Neurotrauma , vol.12 , pp. 1-21
    • Basso, D.M.1    Beattie, M.S.2    Bresnahan, J.C.3
  • 3
    • 0030157694 scopus 로고    scopus 로고
    • Graded histological and locomotor outcomes after spinal cord contusion using the NYU weight-drop device versus transection
    • Basso DM, Beattie MS, Bresnahan JC. Graded histological and locomotor outcomes after spinal cord contusion using the NYU weight-drop device versus transection. Exp Neurol 1996, 139, 244-256.
    • (1996) Exp Neurol , vol.139 , pp. 244-256
    • Basso, D.M.1    Beattie, M.S.2    Bresnahan, J.C.3
  • 5
    • 0028293108 scopus 로고
    • Modeling of acute spinal cord injury in the rat: neuroprotection and enhanced recovery with methylprednisolone, U-74006F and YM-14673
    • Behrmann DL, Bresnahan JC, Beattie MS. Modeling of acute spinal cord injury in the rat: neuroprotection and enhanced recovery with methylprednisolone, U-74006F and YM-14673. Exp Neurol 1994, 126, 61-75.
    • (1994) Exp Neurol , vol.126 , pp. 61-75
    • Behrmann, D.L.1    Bresnahan, J.C.2    Beattie, M.S.3
  • 6
    • 0025003560 scopus 로고
    • Effect of dosage and timing of administration of naloxone on outcome in the rat ventral compression model of spinal cord injury
    • Benzel EC, Lancon JA, Bairnsfather S, Kesterson L. Effect of dosage and timing of administration of naloxone on outcome in the rat ventral compression model of spinal cord injury. Neurosurgery 1990, 27, 597-601.
    • (1990) Neurosurgery , vol.27 , pp. 597-601
    • Benzel, E.C.1    Lancon, J.A.2    Bairnsfather, S.3    Kesterson, L.4
  • 7
    • 0035093854 scopus 로고    scopus 로고
    • Dynamic contrastenhanced MRI of experimental spinal cord injury: in vivo serial studies
    • Bilgen M, Abbe R, Narayana PA. Dynamic contrastenhanced MRI of experimental spinal cord injury: in vivo serial studies. Magn Reson Med 2001, 45, 614-622.
    • (2001) Magn Reson Med , vol.45 , pp. 614-622
    • Bilgen, M.1    Abbe, R.2    Narayana, P.A.3
  • 8
    • 0026787873 scopus 로고
    • Spinal cord injury models: Neurophysiology
    • Blight AR. Spinal cord injury models: Neurophysiology. J Neurotrauma 1992, 9, 147-150.
    • (1992) J Neurotrauma , vol.9 , pp. 147-150
    • Blight, A.R.1
  • 9
    • 0023158586 scopus 로고
    • A behavioral and anatomical analysis of spinal cord injury produced by a feedback-controlled impaction device
    • Bresnahan JC, Beattie MS, Todd FD 3rd, Noyes DH. A behavioral and anatomical analysis of spinal cord injury produced by a feedback-controlled impaction device. Exp Neurol 1987, 95, 548-570.
    • (1987) Exp Neurol , vol.95 , pp. 548-570
    • Bresnahan, J.C.1    Beattie, M.S.2    Todd, F.D.3    Noyes, D.H.4
  • 10
    • 0029012783 scopus 로고
    • The relationships among the severity of spinal cord injury, residual neurological function, axon counts, and counts of retrogradely labeled neurons after experimental spinal cord injury
    • Fehlings MG, Tator CH. The relationships among the severity of spinal cord injury, residual neurological function, axon counts, and counts of retrogradely labeled neurons after experimental spinal cord injury. Exp Neurol 1995, 132, 220-228.
    • (1995) Exp Neurol , vol.132 , pp. 220-228
    • Fehlings, M.G.1    Tator, C.H.2
  • 12
    • 0020807360 scopus 로고
    • Acute spinal cord injury in the rat: comparison of three experimental techniques
    • Khan M, Griebel R. Acute spinal cord injury in the rat: comparison of three experimental techniques. Can J Neurol Sci 1983, 10, 161-165.
    • (1983) Can J Neurol Sci , vol.10 , pp. 161-165
    • Khan, M.1    Griebel, R.2
  • 13
    • 0029566925 scopus 로고
    • A model for acute, chronic, and delayed graded compression of the dog cauda equina: presentation of the gross, microscopic, and vascular anatomy of the dog cauda equina and accuracy in pressure transmission of the compression model
    • Konno S, Yabuki S, Sato K, Olmarker K, Kikuchi S. A model for acute, chronic, and delayed graded compression of the dog cauda equina: presentation of the gross, microscopic, and vascular anatomy of the dog cauda equina and accuracy in pressure transmission of the compression model. Spine (Phila Pa 1976) 1995, 20, 2758-2764.
    • (1995) Spine (Phila Pa 1976) , vol.20 , pp. 2758-2764
    • Konno, S.1    Yabuki, S.2    Sato, K.3    Olmarker, K.4    Kikuchi, S.5
  • 14
    • 0037099667 scopus 로고    scopus 로고
    • Animal models used in spinal cord regeneration research
    • Kwon BK, Oxland TR, Tetzlaff W. Animal models used in spinal cord regeneration research. Spine (Phila Pa 1976) 2002, 27, 1504-1510.
    • (2002) Spine (Phila Pa 1976) , vol.27 , pp. 1504-1510
    • Kwon, B.K.1    Oxland, T.R.2    Tetzlaff, W.3
  • 16
    • 33847638033 scopus 로고    scopus 로고
    • Establishment of a canine spinal cord injury model induced by epidural balloon compression
    • Lim JH, Jung CS, Byeon YE, Kim WH, Yoon JH, Kang KS, Kweon OK. Establishment of a canine spinal cord injury model induced by epidural balloon compression. J Vet Sci 2007, 8, 89-94.
    • (2007) J Vet Sci , vol.8 , pp. 89-94
    • Lim, J.H.1    Jung, C.S.2    Byeon, Y.E.3    Kim, W.H.4    Yoon, J.H.5    Kang, K.S.6    Kweon, O.K.7
  • 18
    • 0026780399 scopus 로고
    • Experimental acute traumatic injury of the adult rat spinal cord by a subdural inflatable balloon: methodology, behavioral analysis, and histopathology
    • Martin D, Schoenen J, Delrée P, Gilson V, Rogister B, Leprince P, Stevenaert A, Moonen G. Experimental acute traumatic injury of the adult rat spinal cord by a subdural inflatable balloon: methodology, behavioral analysis, and histopathology. J Neurosci Res 1992, 32, 539-550.
    • (1992) J Neurosci Res , vol.32 , pp. 539-550
    • Martin, D.1    Schoenen, J.2    Delrée, P.3    Gilson, V.4    Rogister, B.5    Leprince, P.6    Stevenaert, A.7    Moonen, G.8
  • 19
    • 0033968852 scopus 로고    scopus 로고
    • Validation of the weight-drop contusion model in rats: a comparative study of human spinal cord injury
    • Metz GA, Curt A, van de Meent H, Klusman I, Schwab ME, Dietz V. Validation of the weight-drop contusion model in rats: a comparative study of human spinal cord injury. J Neurotrauma 2000, 17, 1-17.
    • (2000) J Neurotrauma , vol.17 , pp. 1-17
    • Metz, G.A.1    Curt, A.2    van de Meent, H.3    Klusman, I.4    Schwab, M.E.5    Dietz, V.6
  • 20
    • 77953233503 scopus 로고    scopus 로고
    • Transplantation of a combination of autologous neural differentiated and undifferentiated mesenchymal stem cells into injured spinal cord of rats
    • Pedram MS, Dehghan MM, Soleimani M, Sharifi D, Marjanmehr SH, Nasiri Z. Transplantation of a combination of autologous neural differentiated and undifferentiated mesenchymal stem cells into injured spinal cord of rats. Spinal Cord 2010, 48, 457-463.
    • (2010) Spinal Cord , vol.48 , pp. 457-463
    • Pedram, M.S.1    Dehghan, M.M.2    Soleimani, M.3    Sharifi, D.4    Marjanmehr, S.H.5    Nasiri, Z.6
  • 21
    • 39049145237 scopus 로고    scopus 로고
    • Clip compression model is useful for thoracic spinal cord injuries: histologic and functional correlates
    • Poon PC, Gupta D, Shoichet MS, Tator CH. Clip compression model is useful for thoracic spinal cord injuries: histologic and functional correlates. Spine (Phila Pa 1976) 2007, 32, 2853-2859.
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. 2853-2859
    • Poon, P.C.1    Gupta, D.2    Shoichet, M.S.3    Tator, C.H.4
  • 23
    • 0017992470 scopus 로고
    • Effect of duration of acute spinal cord compression in a new acute cord injury model in the rat
    • Rivlin AS, Tator CH. Effect of duration of acute spinal cord compression in a new acute cord injury model in the rat. Surg Neurol 1978, 10, 38-43.
    • (1978) Surg Neurol , vol.10 , pp. 38-43
    • Rivlin, A.S.1    Tator, C.H.2
  • 24
    • 1842453803 scopus 로고    scopus 로고
    • Rodent models for treatment of spinal cord injury: research trends and progress toward useful repair
    • Rosenzweig ES, McDonald JW. Rodent models for treatment of spinal cord injury: research trends and progress toward useful repair. Curr Opin Neurol 2004, 17, 121-131.
    • (2004) Curr Opin Neurol , vol.17 , pp. 121-131
    • Rosenzweig, E.S.1    McDonald, J.W.2
  • 25
    • 0028862361 scopus 로고
    • A model for acute, chronic, and delayed graded compression of the dog cauda equina: neurophysiologic and histologic changes induced by acute, graded compression
    • Sato K, Konno S, Yabuki S, Mao GP, Olmarker K, Kikuchi S. A model for acute, chronic, and delayed graded compression of the dog cauda equina: neurophysiologic and histologic changes induced by acute, graded compression. Spine (Phila Pa 1976) 1995, 20, 2386-2391.
    • (1995) Spine (Phila Pa 1976) , vol.20 , pp. 2386-2391
    • Sato, K.1    Konno, S.2    Yabuki, S.3    Mao, G.P.4    Olmarker, K.5    Kikuchi, S.6
  • 26
    • 0344375091 scopus 로고    scopus 로고
    • Experimental modeling of spinal cord injury: characterization of a force-defined injury device
    • Scheff SW, Rabchevsky AG, Fugaccia I, Main JA, Lumpp JE Jr. Experimental modeling of spinal cord injury: characterization of a force-defined injury device. J Neurotrauma 2003, 20, 179-193.
    • (2003) J Neurotrauma , vol.20 , pp. 179-193
    • Scheff, S.W.1    Rabchevsky, A.G.2    Fugaccia, I.3    Main, J.A.4    Lumpp, J.E.5
  • 27
    • 0035672871 scopus 로고    scopus 로고
    • A simple and reproducible model of spinal cord injury induced by epidural balloon inflation in the rat
    • Vanickỳ I, Urdzíková L, Saganová K, Cízková D, Gálik J. A simple and reproducible model of spinal cord injury induced by epidural balloon inflation in the rat. J Neurotrauma 2001, 18, 1399-1407.
    • (2001) J Neurotrauma , vol.18 , pp. 1399-1407
    • Vanickỳ, I.1    Urdzíková, L.2    Saganová, K.3    Cízková, D.4    Gálik, J.5
  • 28
    • 0021917038 scopus 로고
    • Spinal cord contusion in the rat: production of graded, reproducible, injury groups
    • Wrathall JR, Pettegrew RK, Harvey F. Spinal cord contusion in the rat: production of graded, reproducible, injury groups. Exp Neurol 1985, 88, 108-122.
    • (1985) Exp Neurol , vol.88 , pp. 108-122
    • Wrathall, J.R.1    Pettegrew, R.K.2    Harvey, F.3
  • 29
    • 0034835002 scopus 로고    scopus 로고
    • Circulatory disturbance of rat spinal cord induced by occluding ligation of the dorsal spinal vein
    • Zhang Z, Nonaka H, Nagayama T, Hatori T, Ihara F, Zhang L, Akima M. Circulatory disturbance of rat spinal cord induced by occluding ligation of the dorsal spinal vein. Acta Neuropathol 2001, 102, 335-338.
    • (2001) Acta Neuropathol , vol.102 , pp. 335-338
    • Zhang, Z.1    Nonaka, H.2    Nagayama, T.3    Hatori, T.4    Ihara, F.5    Zhang, L.6    Akima, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.