메뉴 건너뛰기




Volumn 7508 LNAI, Issue PART 3, 2012, Pages 32-41

Design and simulation of bio-inspired flexible tactile sensor for prosthesis

Author keywords

Bio inspired; Capacitive; Pressure sensitive rubber (PSR); Tactile Sensor

Indexed keywords

BIO-INSPIRED; CAPACITIVE; DESIGN AND SIMULATION; FLEXIBLE TACTILE SENSORS; PRESSURE-SENSITIVE-RUBBER (PSR); SENSING PERFORMANCE; TACTILE SENSOR ARRAY; TACTILE SENSORS;

EID: 84884872479     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-33503-7_4     Document Type: Conference Paper
Times cited : (1)

References (12)
  • 1
    • 33644901020 scopus 로고    scopus 로고
    • A shear stress sensor for tactile sensing with the piezoresistive cantilever standing in elastic material
    • Noda, K., Hoshino, K., Matsumoto, K., Shimoyama, I.: A shear stress sensor for tactile sensing with the piezoresistive cantilever standing in elastic material. Sens. Actuators A: Phys. 127, 295-301 (2006)
    • (2006) Sens. Actuators A: Phys. , vol.127 , pp. 295-301
    • Noda, K.1    Hoshino, K.2    Matsumoto, K.3    Shimoyama, I.4
  • 3
    • 11944268925 scopus 로고    scopus 로고
    • Cut-and-paste customization of organic FET integrated circuit and its application to electronic artificial skin
    • Kawaguchi, H., Someya, T., Sekitani, T., Sakurai, T.: Cut-and-paste customization of organic FET integrated circuit and its application to electronic artificial skin. IEEE J. Solid-State Circ. 40(1), 177-185 (2005)
    • (2005) IEEE J. Solid-State Circ. , vol.40 , Issue.1 , pp. 177-185
    • Kawaguchi, H.1    Someya, T.2    Sekitani, T.3    Sakurai, T.4
  • 4
    • 49149093632 scopus 로고    scopus 로고
    • Normal and shear force measurement using a flexible polymer tactile sensor with embedded multiple capacitors
    • Lee, H., Chung, J., Chang, S., Yoon, E.: Normal and shear force measurement using a flexible polymer tactile sensor with embedded multiple capacitors. J. Microelectromech. Syst. 17, 934-942 (2008)
    • (2008) J. Microelectromech. Syst. , vol.17 , pp. 934-942
    • Lee, H.1    Chung, J.2    Chang, S.3    Yoon, E.4
  • 5
    • 30944451375 scopus 로고    scopus 로고
    • Anthropomorphic robotic soft fingertip with randomly distributed receptors
    • Hosoda, K., Tada, Y., Asada, M.: Anthropomorphic robotic soft fingertip with randomly distributed receptors. Robotics and Autonomous Systems 54, 104-109 (2006)
    • (2006) Robotics and Autonomous Systems , vol.54 , pp. 104-109
    • Hosoda, K.1    Tada, Y.2    Asada, M.3
  • 9
    • 33749654379 scopus 로고    scopus 로고
    • Human tactile perception as a standard for artificial tactile sensing - A review
    • Dargahi, J., Najarian, S.: Human tactile perception as a standard for artificial tactile sensing-a review. Int. J. Medical Robotics and Computer Assisted Surgery 1(1), 23-35 (2004)
    • (2004) Int. J. Medical Robotics and Computer Assisted Surgery , vol.1 , Issue.1 , pp. 23-35
    • Dargahi, J.1    Najarian, S.2
  • 12
    • 0026736059 scopus 로고
    • Human pressure perception values for constant and moving one-and two-point discrimination
    • Dellon, E.S., Mourey, R., Dellon, A.L.: Human pressure perception values for constant and moving one-and two-point discrimination. J. Plast. Reconstr. Surg. 90, 112-117 (1992)
    • (1992) J. Plast. Reconstr. Surg. , vol.90 , pp. 112-117
    • Dellon, E.S.1    Mourey, R.2    Dellon, A.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.