메뉴 건너뛰기




Volumn 84, Issue , 2014, Pages 394-405

Optimizing RetroICor and RetroKCor corrections for multi-shot 3D FMRI acquisitions

Author keywords

3D EPI; Brainstem; Functional MRI; GRE; Physiological noise; SPGR; SSFP

Indexed keywords

ARTICLE; BOLD SIGNAL; BREATHING PATTERN; BREATHING RATE; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; FOURIER TRANSFORMATION; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HEART RATE; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; PRIORITY JOURNAL; PROCESS OPTIMIZATION; RETROSPECTIVE STUDY; SIGNAL NOISE RATIO; THREE DIMENSIONAL IMAGING; ALGORITHM; ARTIFACT; BRAIN; BRAIN MAPPING; COMPUTER ASSISTED DIAGNOSIS; HUMAN; IMAGE ENHANCEMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; PHYSIOLOGY; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 84884399182     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2013.08.062     Document Type: Article
Times cited : (13)

References (38)
  • 1
    • 0016355478 scopus 로고
    • A new look at the statistical model identification
    • Akaike H. A new look at the statistical model identification. IEEE Trans. Autom. Control. 1974, 19(6):716-723.
    • (1974) IEEE Trans. Autom. Control. , vol.19 , Issue.6 , pp. 716-723
    • Akaike, H.1
  • 2
    • 84857361883 scopus 로고    scopus 로고
    • Complex and magnitude-only preprocessing of 2D and 3D BOLD FMRI data at 7T
    • (Mar)
    • Barry R.L., Strother S.C., Gore J.C. Complex and magnitude-only preprocessing of 2D and 3D BOLD FMRI data at 7T. Magn. Reson. Med. 2012, 67(3):867-871. (Mar).
    • (2012) Magn. Reson. Med. , vol.67 , Issue.3 , pp. 867-871
    • Barry, R.L.1    Strother, S.C.2    Gore, J.C.3
  • 4
    • 77249158790 scopus 로고    scopus 로고
    • Adaptive cyclic physiologic noise modeling and correction in functional MRI
    • (Mar)
    • Beall E.B. Adaptive cyclic physiologic noise modeling and correction in functional MRI. J. Neurosci. Methods 2010, 187(2):216-228. (Mar).
    • (2010) J. Neurosci. Methods , vol.187 , Issue.2 , pp. 216-228
    • Beall, E.B.1
  • 5
    • 1342324773 scopus 로고    scopus 로고
    • Probabilistic independent component analysis for functional magnetic resonance imaging
    • (Feb)
    • Beckmann C.F., Smith S.M. Probabilistic independent component analysis for functional magnetic resonance imaging. IEEE Trans. Med. Imaging 2004, 23(2):137-152. (Feb).
    • (2004) IEEE Trans. Med. Imaging , vol.23 , Issue.2 , pp. 137-152
    • Beckmann, C.F.1    Smith, S.M.2
  • 7
    • 33746852686 scopus 로고    scopus 로고
    • Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in FMRI
    • Birn R.M., Diamond J.B., Smith M.A., Bandettini P.A. Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in FMRI. NeuroImage 2006, 31(4):1536-1548.
    • (2006) NeuroImage , vol.31 , Issue.4 , pp. 1536-1548
    • Birn, R.M.1    Diamond, J.B.2    Smith, M.A.3    Bandettini, P.A.4
  • 9
    • 33744959922 scopus 로고    scopus 로고
    • High field balanced-SSFP FMRI: a BOLD technique with excellent tissue sensitivity and superior large vessel suppression
    • Bowen C.V., Menon R.S., Gati J.S. High field balanced-SSFP FMRI: a BOLD technique with excellent tissue sensitivity and superior large vessel suppression. Proceedings of the 13th Annual Meeting of ISMRM. Miami 2005, 119.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM. Miami , pp. 119
    • Bowen, C.V.1    Menon, R.S.2    Gati, J.S.3
  • 11
    • 57649221314 scopus 로고    scopus 로고
    • Influence of heart rate on the BOLD signal: the cardiac response function
    • (Feb)
    • Chang C., Cunningham J.P., Glover G.H. Influence of heart rate on the BOLD signal: the cardiac response function. NeuroImage 2009, 44(3):857-869. (Feb).
    • (2009) NeuroImage , vol.44 , Issue.3 , pp. 857-869
    • Chang, C.1    Cunningham, J.P.2    Glover, G.H.3
  • 13
    • 1642340636 scopus 로고    scopus 로고
    • B-waves in cerebral and spinal cerebrospinal fluid pulsation measurement by magnetic resonance imaging
    • Friese S., Hamhaber U., Erb M., Klose U. B-waves in cerebral and spinal cerebrospinal fluid pulsation measurement by magnetic resonance imaging. J. Comput. Assist. Tomogr. 2004, 28(2):255-262.
    • (2004) J. Comput. Assist. Tomogr. , vol.28 , Issue.2 , pp. 255-262
    • Friese, S.1    Hamhaber, U.2    Erb, M.3    Klose, U.4
  • 15
    • 0033934775 scopus 로고    scopus 로고
    • Image-based method for retrospective correction of physiological motion effects in FMRI: RETROICOR
    • Glover G.H., Li T.Q., Ress D. Image-based method for retrospective correction of physiological motion effects in FMRI: RETROICOR. Magn. Reson. Med. 2000, 44(1):162-167.
    • (2000) Magn. Reson. Med. , vol.44 , Issue.1 , pp. 162-167
    • Glover, G.H.1    Li, T.Q.2    Ress, D.3
  • 17
    • 48549085503 scopus 로고    scopus 로고
    • The effect of physiological noise in phase functional magnetic resonance imaging: from blood oxygen level-dependent effects to direct detection of neuronal currents
    • Hagberg G.E., Bianciardi M., Brainovich V., Cassara A.M., Maraviglia B. The effect of physiological noise in phase functional magnetic resonance imaging: from blood oxygen level-dependent effects to direct detection of neuronal currents. Magn. Reson. Imaging 2008, 26(7):1026-1040.
    • (2008) Magn. Reson. Imaging , vol.26 , Issue.7 , pp. 1026-1040
    • Hagberg, G.E.1    Bianciardi, M.2    Brainovich, V.3    Cassara, A.M.4    Maraviglia, B.5
  • 19
    • 0029118783 scopus 로고
    • Retrospective estimation and correction of physiological fluctuation in functional MRI
    • Hu X., Le T.H., Parrish T., Erhard P. Retrospective estimation and correction of physiological fluctuation in functional MRI. Magn. Reson. Imaging 1995, 34(2):201-212.
    • (1995) Magn. Reson. Imaging , vol.34 , Issue.2 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parrish, T.3    Erhard, P.4
  • 21
    • 0036425968 scopus 로고    scopus 로고
    • Improved optimization for the robust and accurate linear registration and motion correction of brain images
    • (Oct)
    • Jenkinson M., Bannister P., Brady M., Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. NeuroImage 2002, 17(2):825-841. (Oct).
    • (2002) NeuroImage , vol.17 , Issue.2 , pp. 825-841
    • Jenkinson, M.1    Bannister, P.2    Brady, M.3    Smith, S.4
  • 23
    • 47949117197 scopus 로고    scopus 로고
    • Integration of motion correction and physiological noise regression in FMRI
    • (Aug)
    • Jones T.B., Bandettini P.A., Birn R.M. Integration of motion correction and physiological noise regression in FMRI. NeuroImage 2008, 42(2):582-590. (Aug).
    • (2008) NeuroImage , vol.42 , Issue.2 , pp. 582-590
    • Jones, T.B.1    Bandettini, P.A.2    Birn, R.M.3
  • 24
    • 84872685781 scopus 로고    scopus 로고
    • Signal fluctuations in FMRI data acquired with 2D-EPI and 3D-EPI at 7Tesla
    • Jorge J., Figueiredo P., van der Zwaag W., Marques J.P. Signal fluctuations in FMRI data acquired with 2D-EPI and 3D-EPI at 7Tesla. Magn. Reson. Imaging 2013, 31(2):212-220.
    • (2013) Magn. Reson. Imaging , vol.31 , Issue.2 , pp. 212-220
    • Jorge, J.1    Figueiredo, P.2    van der Zwaag, W.3    Marques, J.P.4
  • 25
    • 1342277260 scopus 로고
    • Bayes factors and model uncertainty
    • Unversity of Washington
    • Kass R., Raftery A. Bayes factors and model uncertainty. Tech. Rep. 254 1993, Unversity of Washington.
    • (1993) Tech. Rep. 254
    • Kass, R.1    Raftery, A.2
  • 27
    • 84878113427 scopus 로고    scopus 로고
    • High-resolution functional MRI at 3 T:3D/2D echo-planar imaging with optimized physiological noise correction
    • Lutti A., Thomas D.L., Hutton C., Weiskopf N. High-resolution functional MRI at 3 T:3D/2D echo-planar imaging with optimized physiological noise correction. Magn. Reson. Med. 2013, 69(6):1657-1664.
    • (2013) Magn. Reson. Med. , vol.69 , Issue.6 , pp. 1657-1664
    • Lutti, A.1    Thomas, D.L.2    Hutton, C.3    Weiskopf, N.4
  • 29
    • 34548539941 scopus 로고    scopus 로고
    • Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths
    • Miller K.L., Smith S.M., Jezzard P., Wiggins G.C., Wiggins C.J. Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths. NeuroImage 2007, 37(4):1227-1236.
    • (2007) NeuroImage , vol.37 , Issue.4 , pp. 1227-1236
    • Miller, K.L.1    Smith, S.M.2    Jezzard, P.3    Wiggins, G.C.4    Wiggins, C.J.5
  • 30
    • 0036160977 scopus 로고    scopus 로고
    • Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging
    • Pfeuffer J., Van de Moortele P.-F., Ugurbil K., Hu X., Glover G.H. Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging. Magn. Reson. Med. 2002, 47(2):344-353.
    • (2002) Magn. Reson. Med. , vol.47 , Issue.2 , pp. 344-353
    • Pfeuffer, J.1    Van de Moortele, P.-F.2    Ugurbil, K.3    Hu, X.4    Glover, G.H.5
  • 31
    • 35148820975 scopus 로고    scopus 로고
    • Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state FMRI BOLD signal
    • (Nov)
    • Shmueli K., van Gelderen P., de Zwart J.A., Horovitz S.G., Fukunaga M., Jansma J.M., Duyn J.H. Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state FMRI BOLD signal. NeuroImage 2007, 38(2):306-320. (Nov).
    • (2007) NeuroImage , vol.38 , Issue.2 , pp. 306-320
    • Shmueli, K.1    van Gelderen, P.2    de Zwart, J.A.3    Horovitz, S.G.4    Fukunaga, M.5    Jansma, J.M.6    Duyn, J.H.7
  • 33
    • 0032925291 scopus 로고    scopus 로고
    • 3D spiral cardiac/respiratory ordered FMRI data acquisition at 3Tesla
    • (May)
    • Stenger V.A., Peltier S., Boada F.E., Noll D.C. 3D spiral cardiac/respiratory ordered FMRI data acquisition at 3Tesla. Magn. Reson. Med. 1999, 41(5):983-991. (May).
    • (1999) Magn. Reson. Med. , vol.41 , Issue.5 , pp. 983-991
    • Stenger, V.A.1    Peltier, S.2    Boada, F.E.3    Noll, D.C.4
  • 34
    • 84884389969 scopus 로고    scopus 로고
    • Characterizing physiological noise in the brainstem: passband SSFP vs. GRE-EPI
    • International Society for Magnetic Resonance in Medicine, Honolulu
    • Tijssen R., Jenkinson M., Jezzard P., Miller K. Characterizing physiological noise in the brainstem: passband SSFP vs. GRE-EPI. Proceedings 17th Scientific Meeting 2009, 1591. International Society for Magnetic Resonance in Medicine, Honolulu.
    • (2009) Proceedings 17th Scientific Meeting , pp. 1591
    • Tijssen, R.1    Jenkinson, M.2    Jezzard, P.3    Miller, K.4
  • 35
    • 79960245298 scopus 로고    scopus 로고
    • Real-time cardiac synchronization with fixed volume frame rate for reducing physiological instabilities in 3D FMRI
    • (Jun)
    • Tijssen R.H.N., Okell T.W., Miller K.L. Real-time cardiac synchronization with fixed volume frame rate for reducing physiological instabilities in 3D FMRI. NeuroImage 2011, 57(4):1364-1375. (Jun).
    • (2011) NeuroImage , vol.57 , Issue.4 , pp. 1364-1375
    • Tijssen, R.H.N.1    Okell, T.W.2    Miller, K.L.3
  • 36
    • 18044385764 scopus 로고    scopus 로고
    • Comparison of physiological noise at 1.5T, 3T and 7T and optimization of FMRI acquisition parameters
    • Triantafyllou C., Hoge R.D., Krueger G., Wiggins C.J., Potthast A., Wiggins G.C., Wald L.L. Comparison of physiological noise at 1.5T, 3T and 7T and optimization of FMRI acquisition parameters. NeuroImage 2005, 26(1):243-250.
    • (2005) NeuroImage , vol.26 , Issue.1 , pp. 243-250
    • Triantafyllou, C.1    Hoge, R.D.2    Krueger, G.3    Wiggins, C.J.4    Potthast, A.5    Wiggins, G.C.6    Wald, L.L.7
  • 37
    • 0036011151 scopus 로고    scopus 로고
    • Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7Tesla
    • Van de Moortele P., Pfeuffer J., Glover G.H., Ugurbil K., Hu X. Respiration-induced B0 fluctuations and their spatial distribution in the human brain at 7Tesla. Magn. Reson. Med. 2002, 47(5):888-895.
    • (2002) Magn. Reson. Med. , vol.47 , Issue.5 , pp. 888-895
    • Van de Moortele, P.1    Pfeuffer, J.2    Glover, G.H.3    Ugurbil, K.4    Hu, X.5
  • 38
    • 1842609636 scopus 로고    scopus 로고
    • Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal
    • (Apr)
    • Wise R.G., Ide K., Poulin M.J., Tracey I. Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal. NeuroImage 2004, 21(4):1652-1664. (Apr).
    • (2004) NeuroImage , vol.21 , Issue.4 , pp. 1652-1664
    • Wise, R.G.1    Ide, K.2    Poulin, M.J.3    Tracey, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.