메뉴 건너뛰기




Volumn 26, Issue 7, 2008, Pages 1026-1040

The effect of physiological noise in phase functional magnetic resonance imaging: from blood oxygen level-dependent effects to direct detection of neuronal currents

Author keywords

BOLD; Brain; fMRI; Human; nc MRI; Phase; Physiological noise

Indexed keywords

ARTERIAL CARBON DIOXIDE TENSION; ARTICLE; BLOOD FLOW VELOCITY; BLOOD PRESSURE; FINGER DERMATOGLYPHICS; FUNCTIONAL MAGNETIC RESONANCE IMAGING; MAGNETIC FIELD; NERVE CONDUCTION; NOISE MEASUREMENT; OXYGEN BLOOD LEVEL; PRIORITY JOURNAL;

EID: 48549085503     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2008.01.010     Document Type: Article
Times cited : (27)

References (39)
  • 1
    • 0036136108 scopus 로고    scopus 로고
    • Postacquisition suppression of large-vessel BOLD signals in high-resolution fMRI
    • Menon R. Postacquisition suppression of large-vessel BOLD signals in high-resolution fMRI. Magn Reson Med 47 (2002) 1-9
    • (2002) Magn Reson Med , vol.47 , pp. 1-9
    • Menon, R.1
  • 2
    • 7444224673 scopus 로고    scopus 로고
    • A complex way to compute fMRI activation
    • Logan B.R., and Rowe D.B. A complex way to compute fMRI activation. Neuroimage 23 (2004) 1078-1092
    • (2004) Neuroimage , vol.23 , pp. 1078-1092
    • Logan, B.R.1    Rowe, D.B.2
  • 3
  • 4
    • 17844408155 scopus 로고    scopus 로고
    • Modeling both the magnitude and phase of complex-valued fMRI data
    • Rowe D.B. Modeling both the magnitude and phase of complex-valued fMRI data. Neuroimage 25 (2004) 1310-1324
    • (2004) Neuroimage , vol.25 , pp. 1310-1324
    • Rowe, D.B.1
  • 5
    • 33845746404 scopus 로고    scopus 로고
    • Macrovascular contribution in activation patterns of working memory
    • Tomasi D.G., and Caparelli E.G. Macrovascular contribution in activation patterns of working memory. J Cereb Blood Flow Metab 27 (2007) 33-42
    • (2007) J Cereb Blood Flow Metab , vol.27 , pp. 33-42
    • Tomasi, D.G.1    Caparelli, E.G.2
  • 6
    • 0038601502 scopus 로고    scopus 로고
    • MRI detection of weak magnetic fields due to an extended current dipole in a conducting sphere: a model for direct detection of neuronal currents in the brain
    • Konn D., Gowland P., and Bowtell R. MRI detection of weak magnetic fields due to an extended current dipole in a conducting sphere: a model for direct detection of neuronal currents in the brain. Magn Reson Med 50 (2003) 40-49
    • (2003) Magn Reson Med , vol.50 , pp. 40-49
    • Konn, D.1    Gowland, P.2    Bowtell, R.3
  • 8
    • 13544252666 scopus 로고    scopus 로고
    • Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents
    • Bianciardi M., Di Russo F., Aprile T., Maraviglia B., and Hagberg G.E. Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents. Magn Reson Imaging 22 10 (2004) 1429-1440
    • (2004) Magn Reson Imaging , vol.22 , Issue.10 , pp. 1429-1440
    • Bianciardi, M.1    Di Russo, F.2    Aprile, T.3    Maraviglia, B.4    Hagberg, G.E.5
  • 9
    • 26044450303 scopus 로고    scopus 로고
    • Direct detection of neuronal activity with MRI: fantasy, possibility or reality
    • Bandettini P.A., Petridou N., and Bodurka J. Direct detection of neuronal activity with MRI: fantasy, possibility or reality. Appl Magn Reson 29 1 (2005) 65-88
    • (2005) Appl Magn Reson , vol.29 , Issue.1 , pp. 65-88
    • Bandettini, P.A.1    Petridou, N.2    Bodurka, J.3
  • 12
    • 36048983773 scopus 로고    scopus 로고
    • Realistic simulation of neuronal activity: a contribution to the debate on direct detection of neuronal currents by MRI
    • Cassarà A., Hagberg G.E., Bianciardi M., and Maraviglia B. Realistic simulation of neuronal activity: a contribution to the debate on direct detection of neuronal currents by MRI. Neuroimage 39 1 (2008) 87-106
    • (2008) Neuroimage , vol.39 , Issue.1 , pp. 87-106
    • Cassarà, A.1    Hagberg, G.E.2    Bianciardi, M.3    Maraviglia, B.4
  • 13
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H., and Patz S. The Rician distribution of noisy MRI data. Magn Reson Med 34 6 (1995) 910-914
    • (1995) Magn Reson Med , vol.34 , Issue.6 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 14
    • 0001587479 scopus 로고    scopus 로고
    • Optimal measurement of magnitude and phase from MR data
    • Bonny J.M., Renou J.P., and Zanca M. Optimal measurement of magnitude and phase from MR data. J Magn Reson B 113 (1996) 136-144
    • (1996) J Magn Reson B , vol.113 , pp. 136-144
    • Bonny, J.M.1    Renou, J.P.2    Zanca, M.3
  • 15
    • 0036338395 scopus 로고    scopus 로고
    • New robust 3-D phase unwrapping algorithms: application to magnetic field mapping and undistorting echoplanar images
    • Cusack R., and Papadikis N. New robust 3-D phase unwrapping algorithms: application to magnetic field mapping and undistorting echoplanar images. Neuroimage 16 (2002) 754-764
    • (2002) Neuroimage , vol.16 , pp. 754-764
    • Cusack, R.1    Papadikis, N.2
  • 16
    • 0142074685 scopus 로고    scopus 로고
    • How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    • Andersson J.L.R., Skare S., and Ashburner J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 20 (2003) 870-888
    • (2003) Neuroimage , vol.20 , pp. 870-888
    • Andersson, J.L.R.1    Skare, S.2    Ashburner, J.3
  • 17
    • 0037225733 scopus 로고    scopus 로고
    • Fast, automated N-dimensional phase-unwrapping algorithm
    • Jenkinson M. Fast, automated N-dimensional phase-unwrapping algorithm. Magn Reson Med 49 1 (2003) 193-197
    • (2003) Magn Reson Med , vol.49 , Issue.1 , pp. 193-197
    • Jenkinson, M.1
  • 18
    • 0036592745 scopus 로고    scopus 로고
    • Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head
    • Collins C.M., Yang B., Yang Q.X., and Smith M.B. Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head. Magn Reson Imaging 20 (2002) 413-424
    • (2002) Magn Reson Imaging , vol.20 , pp. 413-424
    • Collins, C.M.1    Yang, B.2    Yang, Q.X.3    Smith, M.B.4
  • 19
    • 27644557313 scopus 로고    scopus 로고
    • Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging
    • Foerster B.U., Tomasi D., and Caparelli E.C. Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging. Magn Reson Med 54 (2005) 1261-1267
    • (2005) Magn Reson Med , vol.54 , pp. 1261-1267
    • Foerster, B.U.1    Tomasi, D.2    Caparelli, E.C.3
  • 20
    • 0034532740 scopus 로고    scopus 로고
    • A model for susceptibility artefacts from respiration in functional echo-planar magnetic resonance imaging
    • Raj D., Paley D.P., Anderson A.W., Kennan R.P., and Gore J.C. A model for susceptibility artefacts from respiration in functional echo-planar magnetic resonance imaging. Phys Med Biol 45 (2000) 3809-3820
    • (2000) Phys Med Biol , vol.45 , pp. 3809-3820
    • Raj, D.1    Paley, D.P.2    Anderson, A.W.3    Kennan, R.P.4    Gore, J.C.5
  • 21
    • 1842609636 scopus 로고    scopus 로고
    • Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal
    • Wise R.G., Ide K., Poulin M.J., and Tracey I. Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal. Neuroimage 21 (2004) 1652-1664
    • (2004) Neuroimage , vol.21 , pp. 1652-1664
    • Wise, R.G.1    Ide, K.2    Poulin, M.J.3    Tracey, I.4
  • 22
    • 33746852686 scopus 로고    scopus 로고
    • Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI
    • Birn R.M., Diamond J.B., Smith M.A., and Bandettini P.A. Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI. Neuroimage 31 4 (2006) 1536-1548
    • (2006) Neuroimage , vol.31 , Issue.4 , pp. 1536-1548
    • Birn, R.M.1    Diamond, J.B.2    Smith, M.A.3    Bandettini, P.A.4
  • 23
    • 34447556973 scopus 로고    scopus 로고
    • Heart beats brain: the problem of detecting alpha waves by neuronal current imaging in joint EEG-MRI experiments
    • Mandelkow H., Halder P., Brandeis D., Soellinger M., de Zanche N., Luechinger R., et al. Heart beats brain: the problem of detecting alpha waves by neuronal current imaging in joint EEG-MRI experiments. Neuroimage 37 1 (2007) 149-163
    • (2007) Neuroimage , vol.37 , Issue.1 , pp. 149-163
    • Mandelkow, H.1    Halder, P.2    Brandeis, D.3    Soellinger, M.4    de Zanche, N.5    Luechinger, R.6
  • 24
    • 0036011151 scopus 로고    scopus 로고
    • Respiration-induced Bo fluctuations and their spatial distribution in the human brain at 7 Tesla
    • Van de Moortele P.F., Pfeuffer J., Glover G.H., Ugurbil K., and Hu X. Respiration-induced Bo fluctuations and their spatial distribution in the human brain at 7 Tesla. Magn Reson Med 47 (2002) 888-895
    • (2002) Magn Reson Med , vol.47 , pp. 888-895
    • Van de Moortele, P.F.1    Pfeuffer, J.2    Glover, G.H.3    Ugurbil, K.4    Hu, X.5
  • 25
    • 0033433337 scopus 로고    scopus 로고
    • Simulation of in-plane flow imaging
    • Marshall I. Simulation of in-plane flow imaging. Concepts Magn Reson 11 (1999) 379-392
    • (1999) Concepts Magn Reson , vol.11 , pp. 379-392
    • Marshall, I.1
  • 26
    • 0032899352 scopus 로고    scopus 로고
    • Transcranial color-coded duplex sonography of intracranial veins and sinuses in adults. Reference data from 130 volunteers
    • Stolz E., Kaps M., Kern A., Babacan S.S., and Dorndorf W. Transcranial color-coded duplex sonography of intracranial veins and sinuses in adults. Reference data from 130 volunteers. Stroke 30 5 (1999) 1070-1075
    • (1999) Stroke , vol.30 , Issue.5 , pp. 1070-1075
    • Stolz, E.1    Kaps, M.2    Kern, A.3    Babacan, S.S.4    Dorndorf, W.5
  • 27
    • 0034691114 scopus 로고    scopus 로고
    • Coupling between changes in human brain temperature and oxidative metabolism during prolonged visual stimulation
    • Yablonskiy D.A., Ackerman J.H., and Raichle M.R. Coupling between changes in human brain temperature and oxidative metabolism during prolonged visual stimulation. Proc Natl Acad Sci U S A 97 13 (2000) 7603-7608
    • (2000) Proc Natl Acad Sci U S A , vol.97 , Issue.13 , pp. 7603-7608
    • Yablonskiy, D.A.1    Ackerman, J.H.2    Raichle, M.R.3
  • 29
    • 0030701614 scopus 로고    scopus 로고
    • K-space detection and correction of physiological artefacts in fMRI
    • Wowk B., McIntyre M.C., and Saunders J.K. K-space detection and correction of physiological artefacts in fMRI. Magn Reson Med 38 (1997) 1029-1034
    • (1997) Magn Reson Med , vol.38 , pp. 1029-1034
    • Wowk, B.1    McIntyre, M.C.2    Saunders, J.K.3
  • 30
    • 0036160977 scopus 로고    scopus 로고
    • Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging
    • Pfeuffer J., Van de Moortele P.F., Ugurbil K., Hu X., and Glover G.H. Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging. Magn Reson Med 10 (2002) 344-353
    • (2002) Magn Reson Med , vol.10 , pp. 344-353
    • Pfeuffer, J.1    Van de Moortele, P.F.2    Ugurbil, K.3    Hu, X.4    Glover, G.H.5
  • 31
    • 0034789167 scopus 로고    scopus 로고
    • Physiological noise in oxygenation-sensitive magnetic resonance imaging
    • Krüger G., and Glover G.H. Physiological noise in oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 46 (2001) 631-637
    • (2001) Magn Reson Med , vol.46 , pp. 631-637
    • Krüger, G.1    Glover, G.H.2
  • 32
    • 0346373773 scopus 로고    scopus 로고
    • Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3 Tesla
    • de Zwart J.A., Ledden P.J., van Gelderen P., Bodurka J., Chu R., and Duyn J.H. Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3 Tesla. Magn Reson Med 51 (2004) 22-26
    • (2004) Magn Reson Med , vol.51 , pp. 22-26
    • de Zwart, J.A.1    Ledden, P.J.2    van Gelderen, P.3    Bodurka, J.4    Chu, R.5    Duyn, J.H.6
  • 33
    • 18044385764 scopus 로고    scopus 로고
    • Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters
    • Triantafyllou C., Hoge R.D., Krueger G., Wiggins C.J., Potthast A., Wiggins G.C., et al. Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters. Neuroimage 26 (2005) 243-250
    • (2005) Neuroimage , vol.26 , pp. 243-250
    • Triantafyllou, C.1    Hoge, R.D.2    Krueger, G.3    Wiggins, C.J.4    Potthast, A.5    Wiggins, G.C.6
  • 34
    • 0035091609 scopus 로고    scopus 로고
    • Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging
    • Krüger G., Kastrup A., and Glover G.H. Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 45 (2001) 595-604
    • (2001) Magn Reson Med , vol.45 , pp. 595-604
    • Krüger, G.1    Kastrup, A.2    Glover, G.H.3
  • 35
    • 77950288726 scopus 로고    scopus 로고
    • Determination of the brain voxel specific temporal signal-to-noise ratio limit of 3T BOLD weighted time course data
    • Bodurka J., Ye F., Petridou N., and Bandettini P.A. Determination of the brain voxel specific temporal signal-to-noise ratio limit of 3T BOLD weighted time course data. Proc Intl Soc Mag Reson Med 13 (2005) 1554
    • (2005) Proc Intl Soc Mag Reson Med , vol.13 , pp. 1554
    • Bodurka, J.1    Ye, F.2    Petridou, N.3    Bandettini, P.A.4
  • 37
    • 0027973923 scopus 로고
    • Theory of NMR signal behaviour in magnetically inhomogeneous tissues: the static dephasing regime
    • Yablonskiy D.A., and Haacke E.M. Theory of NMR signal behaviour in magnetically inhomogeneous tissues: the static dephasing regime. Magn Reson Med 32 6 (1994) 749-763
    • (1994) Magn Reson Med , vol.32 , Issue.6 , pp. 749-763
    • Yablonskiy, D.A.1    Haacke, E.M.2
  • 38
    • 33847715956 scopus 로고    scopus 로고
    • Sources of phase changes in BOLD and CBV-weighted fMRI
    • Zhao F., Jin T., Wang P., Hu X., and Kim S.G. Sources of phase changes in BOLD and CBV-weighted fMRI. Magn Reson Med 57 (2007) 520-527
    • (2007) Magn Reson Med , vol.57 , pp. 520-527
    • Zhao, F.1    Jin, T.2    Wang, P.3    Hu, X.4    Kim, S.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.