메뉴 건너뛰기




Volumn 23, Issue 8, 2013, Pages 2283-2293

A review on in vitro corrosion performance test of biodegradable metallic materials

Author keywords

biodegradable metallic material; Fe; in vitro corrosion test; Mg

Indexed keywords

BODY FLUIDS; CORROSION RATE; CORROSIVE EFFECTS; ELECTROLYTES; IRON; MAGNESIUM; METALS; SURFACE ROUGHNESS;

EID: 84883812979     PISSN: 10036326     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1003-6326(13)62730-2     Document Type: Article
Times cited : (121)

References (70)
  • 5
    • 33744988409 scopus 로고    scopus 로고
    • Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta [J]
    • M PEUSTER, C HESSE, T SCHLOO, C FINK, P BEERBAUM, C von SCHNAKENBURG Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta [J] Biomaterials 27 28 2006 4955 4962
    • (2006) Biomaterials , vol.27 , Issue.28 , pp. 4955-4962
    • Peuster, M.1    Hesse, C.2    Schloo, T.3    Fink, C.4    Beerbaum, P.5    Von Schnakenburg, C.6
  • 6
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into new zealand white rabbits [J]
    • M PEUSTER, P WOHLSEIN, M BRÜGMANN, M EHLERDING, K SEIDLER, C FINK, H BRAUER, A FISCHER, G HAUSDORF A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into new zealand white rabbits [J] Heart 86 5 2001 563
    • (2001) Heart , vol.86 , Issue.5 , pp. 563
    • Peuster, M.1    Wohlsein, P.2    Brügmann, M.3    Ehlerding, M.4    Seidler, K.5    Fink, C.6    Brauer, H.7    Fischer, A.8    Hausdorf, G.9
  • 8
    • 28844455504 scopus 로고    scopus 로고
    • First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby [J]
    • P ZARTNER, R CESNJEVAR, H SINGER, M WEYAND First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby [J] Catheterization and Cardiovascular Interventions 66 4 2005 590 594
    • (2005) Catheterization and Cardiovascular Interventions , vol.66 , Issue.4 , pp. 590-594
    • Zartner, P.1    Cesnjevar, R.2    Singer, H.3    Weyand, M.4
  • 9
    • 34249655184 scopus 로고    scopus 로고
    • Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial [J]
    • R ERBEL, MARIOC DI, J BARTUNEK, J BONNIER, B de BRUYNE, FR EBERLI, P ERNE, M HAUDE, B HEUBLEIN, M HORRIGAN Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial [J] The Lancet 369 9576 2007 1869 1875
    • (2007) The Lancet , vol.369 , Issue.9576 , pp. 1869-1875
    • Erbel, R.1    Di, M.2    Bartunek, J.3    Bonnier, J.4    De Bruyne, B.5    Eberli, F.R.6    Erne, P.7    Haude, M.8    Heublein, B.9    Horrigan, M.10
  • 12
    • 67349101269 scopus 로고    scopus 로고
    • Biocorrosion behavior of magnesium alloy in different simulated fluids for biomedical application [J]
    • L YANG, E ZHANG Biocorrosion behavior of magnesium alloy in different simulated fluids for biomedical application [J] Materials Science and Engineering C 29 5 2009 1691 1696
    • (2009) Materials Science and Engineering C , vol.29 , Issue.5 , pp. 1691-1696
    • Yang, L.1    Zhang, E.2
  • 13
  • 14
    • 38349153562 scopus 로고    scopus 로고
    • The development of binary Mg-Ca alloys for use as biodegradable materials within bone [J]
    • Z LI, X GU, S LOU, Y ZHENG The development of binary Mg-Ca alloys for use as biodegradable materials within bone [J] Biomaterials 29 10 2008 1329 1344
    • (2008) Biomaterials , vol.29 , Issue.10 , pp. 1329-1344
    • Li, Z.1    Gu, X.2    Lou, S.3    Zheng, Y.4
  • 15
    • 77954665666 scopus 로고    scopus 로고
    • Electroformed pure iron as a new biomaterial for degradable stents: In vitro degradation and preliminary cell viability studies [J]
    • M MORAVEJ, A PURNAMA, M FISET, J COUET, D MANTOVANI Electroformed pure iron as a new biomaterial for degradable stents: In vitro degradation and preliminary cell viability studies [J] Acta Biomaterialia 6 5 2010 1843 1851
    • (2010) Acta Biomaterialia , vol.6 , Issue.5 , pp. 1843-1851
    • Moravej, M.1    Purnama, A.2    Fiset, M.3    Couet, J.4    Mantovani, D.5
  • 17
    • 40649099051 scopus 로고    scopus 로고
    • In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified- simulated body fluid [J]
    • MB KANNAN, RK RAMAN In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified- simulated body fluid [J] Biomaterials 29 15 2008 2306 2314
    • (2008) Biomaterials , vol.29 , Issue.15 , pp. 2306-2314
    • Kannan, M.B.1    Raman, R.K.2
  • 18
    • 32144437418 scopus 로고    scopus 로고
    • How useful is SBF in predicting in vivo bone bioactivity [J]
    • T KOKUBO, H TAKADAMA How useful is SBF in predicting in vivo bone bioactivity [J] Biomaterials 27 15 2006 2907 2915
    • (2006) Biomaterials , vol.27 , Issue.15 , pp. 2907-2915
    • Kokubo, T.1    Takadama, H.2
  • 20
    • 63449088525 scopus 로고    scopus 로고
    • Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation [J]
    • Z YAO, L LI, Z JIANG Adjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation [J] Applied Surface Science 255 13-14 2009 6724 6728
    • (2009) Applied Surface Science , vol.255 , Issue.1314 , pp. 6724-6728
    • Yao, Z.1    Li, L.2    Jiang, Z.3
  • 21
    • 43049181913 scopus 로고    scopus 로고
    • Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial application [J]
    • YW SONG, DY SHAN, EH HAN Electrodeposition of hydroxyapatite coating on AZ91D magnesium alloy for biomaterial application [J] Materials Letters 62 17 2008 3276 3279
    • (2008) Materials Letters , vol.62 , Issue.17 , pp. 3276-3279
    • Song, Y.W.1    Shan, D.Y.2    Han, E.H.3
  • 22
    • 66249109299 scopus 로고    scopus 로고
    • Corrosion resistance and cytocompatibility of biodegradable surgical magnesium alloy coated with hydrogenated amorphous silicon [J]
    • Y XIN, J JIANG, K HUO, G TANG, X TIAN, PK CHU Corrosion resistance and cytocompatibility of biodegradable surgical magnesium alloy coated with hydrogenated amorphous silicon [J] Journal of Biomedical Materials Research: Part A 89 3 2009 717 726
    • (2009) Journal of Biomedical Materials Research: Part A , vol.89 , Issue.3 , pp. 717-726
    • Xin, Y.1    Jiang, J.2    Huo, K.3    Tang, G.4    Tian, X.5    Chu, P.K.6
  • 23
    • 53649100697 scopus 로고    scopus 로고
    • Influence of aggressive ions on the degradation behavior of biomedical magnesium alloy in physiological environment [J]
    • Y XIN, K HUO, H TAO, G TANG, PK CHU Influence of aggressive ions on the degradation behavior of biomedical magnesium alloy in physiological environment [J] Acta Biomaterialia 4 6 2008 2008 2015
    • (2008) Acta Biomaterialia , vol.4 , Issue.6 , pp. 2008-2015
    • Xin, Y.1    Huo, K.2    Tao, H.3    Tang, G.4    Chu, P.K.5
  • 24
    • 64849100196 scopus 로고    scopus 로고
    • Microstructure, mechanical and corrosion properties and biocompatibility of Mg-Zn-Mn alloys for biomedical application [J]
    • E ZHANG, D YIN, L XU, L YANG, K YANG Microstructure, mechanical and corrosion properties and biocompatibility of Mg-Zn-Mn alloys for biomedical application [J] Materials Science and Engineering C 29 3 2009 987 993
    • (2009) Materials Science and Engineering C , vol.29 , Issue.3 , pp. 987-993
    • Zhang, E.1    Yin, D.2    Xu, L.3    Yang, L.4    Yang, K.5
  • 25
    • 67349213357 scopus 로고    scopus 로고
    • Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro [J]
    • A YAMAMOTO, S HIROMOTO Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro [J] Materials Science and Engineering C 29 5 2009 1559 1568
    • (2009) Materials Science and Engineering C , vol.29 , Issue.5 , pp. 1559-1568
    • Yamamoto, A.1    Hiromoto, S.2
  • 27
    • 33847665988 scopus 로고    scopus 로고
    • Corrosiion behavior of magnesium in simulated human body fluid [J]
    • G SONG, S SONG Corrosiion behavior of magnesium in simulated human body fluid [J] Chinese Journal of Physical Chemistry 22 10 2006 1222 1226
    • (2006) Chinese Journal of Physical Chemistry , vol.22 , Issue.10 , pp. 1222-1226
    • Song, G.1    Song, S.2
  • 28
    • 56949088722 scopus 로고    scopus 로고
    • Influence of pH and flow on the polarisation behaviour of pure magnesium in borate buffer solutions [J]
    • S HIROMOTO, A YAMAMOTO, N MARUYAMA, H SOMEKAWA, T MUKAI Influence of pH and flow on the polarisation behaviour of pure magnesium in borate buffer solutions [J] Corrosion Science 50 12 2008 3561 3568
    • (2008) Corrosion Science , vol.50 , Issue.12 , pp. 3561-3568
    • Hiromoto, S.1    Yamamoto, A.2    Maruyama, N.3    Somekawa, H.4    Mukai, T.5
  • 29
    • 34248224956 scopus 로고    scopus 로고
    • A possible biodegradable magnesium implant material [J]
    • G SONG, S SONG A possible biodegradable magnesium implant material [J] Advanced Engineering Materials 9 4 2007 298 302
    • (2007) Advanced Engineering Materials , vol.9 , Issue.4 , pp. 298-302
    • Song, G.1    Song, S.2
  • 31
    • 61349195016 scopus 로고    scopus 로고
    • Phosphating treatment and corrosion properties of Mg-Mn-Zn alloy for biomedical application [J]
    • L XU, E ZHANG, K YANG Phosphating treatment and corrosion properties of Mg-Mn-Zn alloy for biomedical application [J] Journal of Materials Science: Materials in Medicine 20 4 2009 859 867
    • (2009) Journal of Materials Science: Materials in Medicine , vol.20 , Issue.4 , pp. 859-867
    • Xu, L.1    Zhang, E.2    Yang, K.3
  • 32
    • 67349278559 scopus 로고    scopus 로고
    • Corrosion behavior of ZrN/Zr coated biomedical AZ91 magnesium alloy [J]
    • Y XIN, C LIU, K HUO, G TANG, X TIAN, PK CHU Corrosion behavior of ZrN/Zr coated biomedical AZ91 magnesium alloy [J] Surface and Coatings Technology 203 17-18 2009 2554 2557
    • (2009) Surface and Coatings Technology , vol.203 , Issue.1718 , pp. 2554-2557
    • Xin, Y.1    Liu, C.2    Huo, K.3    Tang, G.4    Tian, X.5    Chu, P.K.6
  • 33
    • 56349103543 scopus 로고    scopus 로고
    • On the biodegradation performance of an Mg-Y-RE alloy with various surface conditions in simulated body fluid [J]
    • AC HÄNZI, P GUNDE, M SCHINHAMMER, PJ UGGOWITZER On the biodegradation performance of an Mg-Y-RE alloy with various surface conditions in simulated body fluid [J] Acta Biomaterialia 5 1 2009 162 171
    • (2009) Acta Biomaterialia , vol.5 , Issue.1 , pp. 162-171
    • Hänzi, A.C.1    Gunde, P.2    Schinhammer, M.3    Uggowitzer, P.J.4
  • 34
    • 0142031176 scopus 로고    scopus 로고
    • Influence of surface roughness of stainless steel on microbial adhesion and corrosion resistance [J]
    • LR HILBERT, D BAGGE-RAVN, J KOLD, L GRAM Influence of surface roughness of stainless steel on microbial adhesion and corrosion resistance [J] International biodeterioration & biodegradation 52 3 2003 175 185
    • (2003) International Biodeterioration & Biodegradation , vol.52 , Issue.3 , pp. 175-185
    • Hilbert, L.R.1    Bagge-Ravn, D.2    Kold, J.3    Gram, L.4
  • 37
  • 38
    • 68949175027 scopus 로고    scopus 로고
    • Effect of laser surface melting on corrosion behaviour of AZ91D Mg alloy in simulated-modified body fluid [J]
    • YC GUAN, W ZHOU, HY ZHENG Effect of laser surface melting on corrosion behaviour of AZ91D Mg alloy in simulated-modified body fluid [J] Journal of Applied Electrochemistry 39 9 2009 1457 1464
    • (2009) Journal of Applied Electrochemistry , vol.39 , Issue.9 , pp. 1457-1464
    • Guan, Y.C.1    Zhou, W.2    Zheng, H.Y.3
  • 39
    • 56549090894 scopus 로고    scopus 로고
    • In vitro corrosion and biocompatibility of binary magnesium alloys [J]
    • X GU, Y ZHENG, Y CHENG, S ZHONG, T XI In vitro corrosion and biocompatibility of binary magnesium alloys [J] Biomaterials 30 4 2009 484 498
    • (2009) Biomaterials , vol.30 , Issue.4 , pp. 484-498
    • Gu, X.1    Zheng, Y.2    Cheng, Y.3    Zhong, S.4    Xi, T.5
  • 41
    • 68649125519 scopus 로고    scopus 로고
    • Microstructure and corrosion behavior of coated AZ91 alloy by microarc oxidation for biomedical application [J]
    • YM WANG, FH WANG, MJ XU, B ZHAO, LX GUO, JH OUYANG Microstructure and corrosion behavior of coated AZ91 alloy by microarc oxidation for biomedical application [J] Applied Surface Science 255 22 2009 9124 9131
    • (2009) Applied Surface Science , vol.255 , Issue.22 , pp. 9124-9131
    • Wang, Y.M.1    Wang, F.H.2    Xu, M.J.3    Zhao, B.4    Guo, L.X.5    Ouyang, J.H.6
  • 43
    • 48349088693 scopus 로고    scopus 로고
    • Effect of Zn on mechanical property and corrosion property of extruded Mg-Zn-Mn alloy [J]
    • DS YIN, EL ZHANG, SY ZENG Effect of Zn on mechanical property and corrosion property of extruded Mg-Zn-Mn alloy [J] Transactions of Nonferrous Metals Society of China 18 4 2008 763 768
    • (2008) Transactions of Nonferrous Metals Society of China , vol.18 , Issue.4 , pp. 763-768
    • Yin, D.S.1    Zhang, E.L.2    Zeng, S.Y.3
  • 44
    • 40149103265 scopus 로고    scopus 로고
    • In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application [J]
    • L XU, E ZHANG, D YIN, S ZENG, K YANG In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application [J] Journal of Materials Science: Materials in Medicine 19 3 2008 1017 1025
    • (2008) Journal of Materials Science: Materials in Medicine , vol.19 , Issue.3 , pp. 1017-1025
    • Xu, L.1    Zhang, E.2    Yin, D.3    Zeng, S.4    Yang, K.5
  • 45
    • 48949114890 scopus 로고    scopus 로고
    • Influence of Ca on the corrosion properties of magnesium for biomaterials [J]
    • WC KIM, JG KIM, JY LEE, HK SEOK Influence of Ca on the corrosion properties of magnesium for biomaterials [J] Materials Letters 62 25 2008 4146 4148
    • (2008) Materials Letters , vol.62 , Issue.25 , pp. 4146-4148
    • Kim, W.C.1    Kim, J.G.2    Lee, J.Y.3    Seok, H.K.4
  • 46
    • 44049101326 scopus 로고    scopus 로고
    • Microstructure, mechanical properties and corrosion properties of Mg-Zn-Y alloys with low Zn content [J]
    • E ZHANG, W HE, H DU, K YANG Microstructure, mechanical properties and corrosion properties of Mg-Zn-Y alloys with low Zn content [J] Materials Science and Engineering A 488 1 2008 102 111
    • (2008) Materials Science and Engineering A , vol.488 , Issue.1 , pp. 102-111
    • Zhang, E.1    He, W.2    Du, H.3    Yang, K.4
  • 48
    • 70349778473 scopus 로고    scopus 로고
    • Corrosion resistance and blood compatibility of lanthanum ion implanted pure iron by MEVVA [J]
    • S ZHU, N HUANG, H SHU, Y WU, L XU Corrosion resistance and blood compatibility of lanthanum ion implanted pure iron by MEVVA [J] Applied Surface Science 256 1 2009 99 104
    • (2009) Applied Surface Science , vol.256 , Issue.1 , pp. 99-104
    • Zhu, S.1    Huang, N.2    Shu, H.3    Wu, Y.4    Xu, L.5
  • 49
    • 77954685452 scopus 로고    scopus 로고
    • Design strategy for biodegradable Fe-based alloys for medical applications [J]
    • M SCHINHAMMER, AC HÄNZI, JF LÖFFLER, PJ UGGOWITZER Design strategy for biodegradable Fe-based alloys for medical applications [J] Acta Biomaterialia 6 5 2010 1705 1713
    • (2010) Acta Biomaterialia , vol.6 , Issue.5 , pp. 1705-1713
    • Schinhammer, M.1    Hänzi, A.C.2    Löffler, J.F.3    Uggowitzer, P.J.4
  • 50
    • 79251648817 scopus 로고    scopus 로고
    • Effects of alloying elements (Mn, Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron [J]
    • B LIU, YF ZHENG Effects of alloying elements (Mn, Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron [J] Acta Biomaterialia 7 3 2011 1407 1420
    • (2011) Acta Biomaterialia , vol.7 , Issue.3 , pp. 1407-1420
    • Liu, B.1    Zheng, Y.F.2
  • 51
    • 49649120694 scopus 로고    scopus 로고
    • Iron-manganese: New class of metallic degradable biomaterials prepared by powder metallurgy [J]
    • H HERMAWAN, H ALAMDARI, D MANTOVANI, D DUBÉ Iron-manganese: New class of metallic degradable biomaterials prepared by powder metallurgy [J] Powder Metallurgy 51 1 2008 38 45
    • (2008) Powder Metallurgy , vol.51 , Issue.1 , pp. 38-45
    • Hermawan, H.1    Alamdari, H.2    Mantovani, D.3    Dubé, D.4
  • 52
    • 84883828587 scopus 로고    scopus 로고
    • The influence of potential sweep rate on the results of the electrode process kinetic parameters test [J]
    • (in Chinese)
    • Z JIA, X LI, C DU The influence of potential sweep rate on the results of the electrode process kinetic parameters test [J] Chinese Journal of Corrosion and Protection 31 11 2010 830 832 (in Chinese)
    • (2010) Chinese Journal of Corrosion and Protection , vol.31 , Issue.11 , pp. 830-832
    • Jia, Z.1    Li, X.2    Du, C.3
  • 53
    • 84883794313 scopus 로고    scopus 로고
    • The influence of equivalent circuit element parameter value on ac impedance spectrum [J]
    • (in Chinese)
    • X CUI The influence of equivalent circuit element parameter value on ac impedance spectrum [J] Chinese Journal of Hebei Normal University 26 4 2002 376 380 (in Chinese)
    • (2002) Chinese Journal of Hebei Normal University , vol.26 , Issue.4 , pp. 376-380
    • Cui, X.1
  • 57
    • 80255124824 scopus 로고    scopus 로고
    • Dynamic behaviors of a Ca-P coated AZ31B magnesium alloy during in vitro and in vivo degradations [J]
    • Q WANG, L TAN, W XU, B ZHANG, K YANG Dynamic behaviors of a Ca-P coated AZ31B magnesium alloy during in vitro and in vivo degradations [J] Materials Science and Engineering B 176 20 2011 1718 1726
    • (2011) Materials Science and Engineering B , vol.176 , Issue.20 , pp. 1718-1726
    • Wang, Q.1    Tan, L.2    Xu, W.3    Zhang, B.4    Yang, K.5
  • 60
    • 50349101414 scopus 로고    scopus 로고
    • Modification of degradation behavior of magnesium alloy by IBAD coating of calcium phosphate [J]
    • JX YANG, YP JIAO, FZ CUI, IS LEE, QS YIN, Y ZHANG Modification of degradation behavior of magnesium alloy by IBAD coating of calcium phosphate [J] Surface and Coatings Technology 202 22 2008 5733 5736
    • (2008) Surface and Coatings Technology , vol.202 , Issue.22 , pp. 5733-5736
    • Yang, J.X.1    Jiao, Y.P.2    Cui, F.Z.3    Lee, I.S.4    Yin, Q.S.5    Zhang, Y.6
  • 61
    • 77954519305 scopus 로고    scopus 로고
    • Dynamic degradation behavior of MgZn alloy in circulating m-SBF [J]
    • Y CHEN, S ZHANG, J LI, Y SONG, C ZHAO, X ZHANG Dynamic degradation behavior of MgZn alloy in circulating m-SBF [J] Materials Letters 64 18 2010 1996 1999
    • (2010) Materials Letters , vol.64 , Issue.18 , pp. 1996-1999
    • Chen, Y.1    Zhang, S.2    Li, J.3    Song, Y.4    Zhao, C.5    Zhang, X.6
  • 62
    • 38949193830 scopus 로고    scopus 로고
    • Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials [J]
    • J LÉVESQUE, H HERMAWAN, D DUBÉ, D MANTOVANI Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials [J] Acta Biomaterialia 4 2 2008 284 295
    • (2008) Acta Biomaterialia , vol.4 , Issue.2 , pp. 284-295
    • Lévesque, J.1    Hermawan, H.2    Dubé, D.3    Mantovani, D.4
  • 63
    • 67349109411 scopus 로고    scopus 로고
    • Biocompatibility of pure iron: In vitro assessment of degradation kinetics and cytotoxicity on endothelial cells [J]
    • S ZHU, N HUANG, L XU, Y ZHANG, H LIU, H SUN, Y LENG Biocompatibility of pure iron: In vitro assessment of degradation kinetics and cytotoxicity on endothelial cells [J] Materials Science and Engineering C 29 5 2009 1589 1592
    • (2009) Materials Science and Engineering C , vol.29 , Issue.5 , pp. 1589-1592
    • Zhu, S.1    Huang, N.2    Xu, L.3    Zhang, Y.4    Liu, H.5    Sun, H.6    Leng, Y.7
  • 64
    • 64849089654 scopus 로고    scopus 로고
    • Improve corrosion resistance of magnesium in simulated body fluid by dicalcium phosphate dihydrate coating [J]
    • Y WANG, M WEI, J GAO Improve corrosion resistance of magnesium in simulated body fluid by dicalcium phosphate dihydrate coating [J] Materials Science and Engineering C 29 4 2009 1311 1316
    • (2009) Materials Science and Engineering C , vol.29 , Issue.4 , pp. 1311-1316
    • Wang, Y.1    Wei, M.2    Gao, J.3
  • 65
    • 79952186035 scopus 로고    scopus 로고
    • In vitro studies of biomedical magnesium alloys in a simulated physiological environment: A review [J]
    • Y XIN, T HU, PK CHU In vitro studies of biomedical magnesium alloys in a simulated physiological environment: A review [J] Acta Biomaterialia 7 4 2011 1452 1459
    • (2011) Acta Biomaterialia , vol.7 , Issue.4 , pp. 1452-1459
    • Xin, Y.1    Hu, T.2    Chu, P.K.3
  • 66
    • 80255137443 scopus 로고    scopus 로고
    • In vitro degradation performance and biological response of a Mg-Zn-Zr alloy [J]
    • XN GU, N LI, YF ZHENG, L RUAN In vitro degradation performance and biological response of a Mg-Zn-Zr alloy [J] Materials Science and Engineering B 176 20 2011 1778 1784
    • (2011) Materials Science and Engineering B , vol.176 , Issue.20 , pp. 1778-1784
    • Gu, X.N.1    Li, N.2    Zheng, Y.F.3    Ruan, L.4
  • 67
    • 1342283923 scopus 로고    scopus 로고
    • Understanding magnesium corrosion - A framework for improved alloy performance [J]
    • G SONG, A ATRENS Understanding magnesium corrosion - A framework for improved alloy performance [J] Advanced Engineering Materials 5 12 2004 837 858
    • (2004) Advanced Engineering Materials , vol.5 , Issue.12 , pp. 837-858
    • Song, G.1    Atrens, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.