메뉴 건너뛰기




Volumn 6, Issue 5, 2010, Pages 1843-1851

Electroformed pure iron as a new biomaterial for degradable stents: In vitro degradation and preliminary cell viability studies

Author keywords

Cell viability; Degradable materials; Electroforming; In vitro degradation

Indexed keywords

CELL PROLIFERATION; DEGRADATION; IRON; STENTS;

EID: 77954665666     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2010.01.008     Document Type: Article
Times cited : (152)

References (33)
  • 1
  • 3
    • 35848967011 scopus 로고    scopus 로고
    • Promise and challenges of bioabsorbable stents
    • R. Waksman Promise and challenges of bioabsorbable stents Catheter Cardiovasc Interv 70 2007 407 414
    • (2007) Catheter Cardiovasc Interv , vol.70 , pp. 407-414
    • Waksman, R.1
  • 4
    • 33749451169 scopus 로고    scopus 로고
    • Update on bioabsorbable stents: From bench to clinical
    • R. Waksman Update on bioabsorbable stents: from bench to clinical Interv Cardiol 19 2006 414 421
    • (2006) Interv Cardiol , vol.19 , pp. 414-421
    • Waksman, R.1
  • 6
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits
    • M. Peuster A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits Heart 86 2001 563 569
    • (2001) Heart , vol.86 , pp. 563-569
    • Peuster, M.1
  • 7
    • 34248224956 scopus 로고    scopus 로고
    • A possible biodegradable magnesium implant material
    • G. Song, and S. Song A possible biodegradable magnesium implant material Adv Mater Eng 9 2007 298 302
    • (2007) Adv Mater Eng , vol.9 , pp. 298-302
    • Song, G.1    Song, S.2
  • 8
    • 38949193830 scopus 로고    scopus 로고
    • Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials
    • J. Lévesque, H. Hermawan, D. Dubé, and D. Mantovani Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials Acta Biomater 4 2008 284 295
    • (2008) Acta Biomater , vol.4 , pp. 284-295
    • Lévesque, J.1    Hermawan, H.2    Dubé, D.3    Mantovani, D.4
  • 9
    • 56549090894 scopus 로고    scopus 로고
    • In vitro corrosion and biocompatibility of binary magnesium alloy
    • X. Gu, Y. Zheng, Y. Cheng, S. Zhong, and T. Xi In vitro corrosion and biocompatibility of binary magnesium alloy Biomaterials 9 2009 484 498
    • (2009) Biomaterials , vol.9 , pp. 484-498
    • Gu, X.1    Zheng, Y.2    Cheng, Y.3    Zhong, S.4    Xi, T.5
  • 10
    • 49649120694 scopus 로고    scopus 로고
    • Iron-manganese: New class of metallic degradable biomaterials prepared by powder metallurgy
    • H.D. Hermawan, H. Alamdari, D. Mantovani, and D. Dubé Iron-manganese: new class of metallic degradable biomaterials prepared by powder metallurgy Powder metall 51 2008 38 45
    • (2008) Powder Metall , vol.51 , pp. 38-45
    • Hermawan, H.D.1    Alamdari, H.2    Mantovani, D.3    Dubé, D.4
  • 11
    • 27644597192 scopus 로고    scopus 로고
    • In vitro and in vivo corrosion measurements of magnesium alloy
    • F. Witte In vitro and in vivo corrosion measurements of magnesium alloy Biomaterials 27 2006 1013 1018
    • (2006) Biomaterials , vol.27 , pp. 1013-1018
    • Witte, F.1
  • 12
    • 40649099051 scopus 로고    scopus 로고
    • In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid
    • M. B Kannan, and R.K. S Rama In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid Biomaterials 29 2008 2306 2314
    • (2008) Biomaterials , vol.29 , pp. 2306-2314
    • Kannan, M.B.1    Rama, R.K.S.2
  • 13
    • 57649090012 scopus 로고    scopus 로고
    • Degradation behaviour of metallic biomaterials for degradable stents
    • H. Hermawan, M. Moravej, D. Dubé, M. Fiset, and M. Mantovani Degradation behaviour of metallic biomaterials for degradable stents Adv Mater Res 15-17 2007 113 118
    • (2007) Adv Mater Res , vol.1517 , pp. 113-118
    • Hermawan, H.1    Moravej, M.2    Dubé, D.3    Fiset, M.4    Mantovani, M.5
  • 14
    • 64749105838 scopus 로고    scopus 로고
    • Biodegradable behaviors of AZ31 magnesium alloy in simulated body fluid
    • Y. Song, D. Shan, R. Chen, F. Zhang, and E.H. Ha Biodegradable behaviors of AZ31 magnesium alloy in simulated body fluid Mater Sci Eng C 29 2009 1039 1045
    • (2009) Mater Sci Eng C , vol.29 , pp. 1039-1045
    • Song, Y.1    Shan, D.2    Chen, R.3    Zhang, F.4    Ha, E.H.5
  • 15
    • 77649201086 scopus 로고    scopus 로고
    • Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stent
    • in press doi:10.1002/jbm.a.32224
    • Hermawan H, Dubé D, Mantovani D. Degradable metallic biomaterials: design and development of Fe-Mn alloys for stent. J Biomed Mater Res, in press, doi:10.1002/jbm.a.32224.
    • J Biomed Mater Res
    • Hermawan, H.1    Dubé, D.2    Mantovani, D.3
  • 16
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
    • B. Heublein, R. Rohde, V. Kaese, M. Niemeyer, W. Hartung, and A. Haverich Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? Heart 89 2003 651 665
    • (2003) Heart , vol.89 , pp. 651-665
    • Heublein, B.1    Rohde, R.2    Kaese, V.3    Niemeyer, M.4    Hartung, W.5    Haverich, A.6
  • 17
    • 9244220627 scopus 로고    scopus 로고
    • Drug-eluting bioabsorbable magnesium stent
    • C. Di Mario Drug-eluting bioabsorbable magnesium stent Interv Cardiol 17 2004 391 395
    • (2004) Interv Cardiol , vol.17 , pp. 391-395
    • Di Mario, C.1
  • 18
    • 33744988409 scopus 로고    scopus 로고
    • Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
    • M. Peuster, C. Hesse, T. Schloo, C. Fink, P. Beerbaum, and C.V. Schnakenburg Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta Biomaterials 27 2006 4955 4962
    • (2006) Biomaterials , vol.27 , pp. 4955-4962
    • Peuster, M.1    Hesse, C.2    Schloo, T.3    Fink, C.4    Beerbaum, P.5    Schnakenburg, C.V.6
  • 19
    • 56549115849 scopus 로고    scopus 로고
    • Development of degradable Fe-35Mn alloy for biomedical applications
    • H. Hermawan, D. Dubé, and D. Mantovani Development of degradable Fe-35Mn alloy for biomedical applications Adv Mater Res 15-17 2007 107 112
    • (2007) Adv Mater Res , vol.1517 , pp. 107-112
    • Hermawan, H.1    Dubé, D.2    Mantovani, D.3
  • 20
    • 56349103543 scopus 로고    scopus 로고
    • On the biodegradation performance of an Mg-Y-Re alloy with various surface conditions in simulated body fluid
    • A.C. Hanzi, P. Gunde, M. Schinhammer, and P.J. Uggowitzer On the biodegradation performance of an Mg-Y-Re alloy with various surface conditions in simulated body fluid Acta Biomater 5 2009 162 171
    • (2009) Acta Biomater , vol.5 , pp. 162-171
    • Hanzi, A.C.1    Gunde, P.2    Schinhammer, M.3    Uggowitzer, P.J.4
  • 21
    • 77954667713 scopus 로고    scopus 로고
    • Electroformed iron as a new biomaterial for degradable stent: Development process and structure-properties relationship
    • M. Moravej, F. Prima, M. Fiset, and D. Mantovani Electroformed iron as a new biomaterial for degradable stent: development process and structure-properties relationship Acta Biomater 6 2010 1726 1735
    • (2010) Acta Biomater , vol.6 , pp. 1726-1735
    • Moravej, M.1    Prima, F.2    Fiset, M.3    Mantovani, D.4
  • 23
    • 28844497993 scopus 로고    scopus 로고
    • Control of smooth muscle cell proliferation by ferrous iron
    • P.P. Mueller, T. May, A. Perz, H. Hauser, and M. Peuster Control of smooth muscle cell proliferation by ferrous iron Biomaterials 27 2006 2193 2200
    • (2006) Biomaterials , vol.27 , pp. 2193-2200
    • Mueller, P.P.1    May, T.2    Perz, A.3    Hauser, H.4    Peuster, M.5
  • 24
    • 34547940121 scopus 로고    scopus 로고
    • In vitro and in vivo biocompatibility testing of absorbable metal stents
    • A. Loos, R. Rohde, A. Haverich, and S. Barlach In vitro and in vivo biocompatibility testing of absorbable metal stents Micromol Symp 253 2007 103 108
    • (2007) Micromol Symp , vol.253 , pp. 103-108
    • Loos, A.1    Rohde, R.2    Haverich, A.3    Barlach, S.4
  • 25
    • 56549090894 scopus 로고    scopus 로고
    • In vitro corrosion and biocompatibility of binary magnesium alloys
    • X. Gua, Y. Zhenga, Y. Chengb, S. Zhongb, and T. Xib In vitro corrosion and biocompatibility of binary magnesium alloys Biomaterials 30 2008 484 498
    • (2008) Biomaterials , vol.30 , pp. 484-498
    • Gua, X.1    Zhenga, Y.2    Chengb, Y.3    Zhongb, S.4    Xib, T.5
  • 26
    • 10844250342 scopus 로고    scopus 로고
    • Grain structure of thin electrodeposited and rolled copper foils
    • H.D. Merchant, W.C. Liu, L.A. Giannuzzi, and J.G. Morris Grain structure of thin electrodeposited and rolled copper foils Mater Charact 53 2004 335 360
    • (2004) Mater Charact , vol.53 , pp. 335-360
    • Merchant, H.D.1    Liu, W.C.2    Giannuzzi, L.A.3    Morris, J.G.4
  • 28
    • 67349109411 scopus 로고    scopus 로고
    • Biocompatibility of pure iron: In vitro assessment of degradation kinetics and cytotoxicity on endothelial cells
    • S. Zhu Biocompatibility of pure iron: in vitro assessment of degradation kinetics and cytotoxicity on endothelial cells Mater Sci Eng C 29 2009 1589 1592
    • (2009) Mater Sci Eng C , vol.29 , pp. 1589-1592
    • Zhu, S.1
  • 29
    • 0001209143 scopus 로고
    • Iron compounds formed by the aerial oxidation of ferrous salt solutions
    • M. Kiama, and T. Takada Iron compounds formed by the aerial oxidation of ferrous salt solutions Bull Chem Soc Jpn 45 1972 1923 1924
    • (1972) Bull Chem Soc Jpn , vol.45 , pp. 1923-1924
    • Kiama, M.1    Takada, T.2
  • 30
    • 0142081127 scopus 로고
    • Mechanism of formation of magnetite from ferrous hydroxide in aqueous corrosion process
    • M.M. Olowe, D. Rezel, and J.M.R. Génin Mechanism of formation of magnetite from ferrous hydroxide in aqueous corrosion process Hyperfine Interact 46 1989 429 436
    • (1989) Hyperfine Interact , vol.46 , pp. 429-436
    • Olowe, M.M.1    Rezel, D.2    Génin, J.M.R.3
  • 32
    • 0028798434 scopus 로고
    • Oxidative mechanisms in the toxicity of metal ions
    • S.J. Stohs, and D. Badgchi Oxidative mechanisms in the toxicity of metal ions Free Radical Biol Med 18 1995 321 336
    • (1995) Free Radical Biol Med , vol.18 , pp. 321-336
    • Stohs, S.J.1    Badgchi, D.2
  • 33
    • 43049108398 scopus 로고    scopus 로고
    • WST-1-based cell cytotoxicity assay as a substitute for MTT-based assay for rapid detection of toxigenic Bacillus species using CHO cell line
    • P. Ngamwongsatit, P.P. Banada, W. Panbangred, and A.K. Bhunia WST-1-based cell cytotoxicity assay as a substitute for MTT-based assay for rapid detection of toxigenic Bacillus species using CHO cell line Microbiol Methods 73 2008 211 215
    • (2008) Microbiol Methods , vol.73 , pp. 211-215
    • Ngamwongsatit, P.1    Banada, P.P.2    Panbangred, W.3    Bhunia, A.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.