메뉴 건너뛰기




Volumn 35, Issue 10, 2013, Pages 1465-1475

Numerical simulation of left ventricular assist device implantations: Comparing the ascending and the descending aorta cannulations

Author keywords

Blood flow models; Geometrical multiscale modeling; Hemodynamics; Left ventricular assist device; Wave propagation

Indexed keywords

BLOOD FLOW MODELS; CARDIOPULMONARY BYPASS; CIRCULATORY SYSTEMS; LUMPED-PARAMETERS MODELS; MULTI-SCALE MODELING; ONE-DIMENSIONAL MODEL; PRESSURE WAVEFORMS; SPECIFIC LOCATION;

EID: 84883170013     PISSN: 13504533     EISSN: 18734030     Source Type: Journal    
DOI: 10.1016/j.medengphy.2013.03.022     Document Type: Article
Times cited : (26)

References (45)
  • 2
    • 79751531393 scopus 로고    scopus 로고
    • Heart disease and stroke statistics - 2011 update: a report from the American Heart Association
    • Roger V.L., Go A.S., Lloyd-Jones D.M., Adams R.J., Berry J.D., Brown T.M., et al. Heart disease and stroke statistics - 2011 update: a report from the American Heart Association. Circulation 2011, 123:e18-e209.
    • (2011) Circulation , vol.123
    • Roger, V.L.1    Go, A.S.2    Lloyd-Jones, D.M.3    Adams, R.J.4    Berry, J.D.5    Brown, T.M.6
  • 4
    • 33750500333 scopus 로고    scopus 로고
    • Left ventricular assist device and drug therapy for the reversal of heart failure
    • Birks E.J., Tansley P.D., Hardy J., George R.S., Bowles C.T., Burke M., et al. Left ventricular assist device and drug therapy for the reversal of heart failure. N Engl J Med 2006, 355:1873-1884.
    • (2006) N Engl J Med , vol.355 , pp. 1873-1884
    • Birks, E.J.1    Tansley, P.D.2    Hardy, J.3    George, R.S.4    Bowles, C.T.5    Burke, M.6
  • 6
    • 77954379167 scopus 로고    scopus 로고
    • Mechanical circulatory support for bridge to decision: which device and when to decide
    • Ziemba E.A., John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg 2010, 25:425-433.
    • (2010) J Card Surg , vol.25 , pp. 425-433
    • Ziemba, E.A.1    John, R.2
  • 8
    • 33646162657 scopus 로고    scopus 로고
    • Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 heart in patients with previous median sternotomy
    • Frazier O.H., Gregoric I.D., Cohn W.E. Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 heart in patients with previous median sternotomy. J Heart Lung Transpl 2006, 25:499-503.
    • (2006) J Heart Lung Transpl , vol.25 , pp. 499-503
    • Frazier, O.H.1    Gregoric, I.D.2    Cohn, W.E.3
  • 9
    • 4544247955 scopus 로고    scopus 로고
    • Effects of left ventricular assist device support and outflow graft location upon aortic blood flow
    • Litwak K.N., Koenig S.C., Tsukui H., Kihara S.I., Wu Z., Pantalos G.M. Effects of left ventricular assist device support and outflow graft location upon aortic blood flow. ASAIO J 2004, 50:432-437.
    • (2004) ASAIO J , vol.50 , pp. 432-437
    • Litwak, K.N.1    Koenig, S.C.2    Tsukui, H.3    Kihara, S.I.4    Wu, Z.5    Pantalos, G.M.6
  • 10
    • 27744458446 scopus 로고    scopus 로고
    • Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation
    • Litwak K.N., Koenig S.C., Cheng R.C., Giridharan G.A., Gillars K.J., Pantalos G.M. Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation. Artif Organs 2005, 29:629-635.
    • (2005) Artif Organs , vol.29 , pp. 629-635
    • Litwak, K.N.1    Koenig, S.C.2    Cheng, R.C.3    Giridharan, G.A.4    Gillars, K.J.5    Pantalos, G.M.6
  • 11
    • 0842286457 scopus 로고    scopus 로고
    • In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices
    • DiGiorgi P.L., Smith D.L., Naka Y., Oz M.C. In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices. J Heart Lung Transpl 2004, 23:186-192.
    • (2004) J Heart Lung Transpl , vol.23 , pp. 186-192
    • DiGiorgi, P.L.1    Smith, D.L.2    Naka, Y.3    Oz, M.C.4
  • 12
    • 78650936469 scopus 로고    scopus 로고
    • Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis
    • Nawata K., Nishimura T., Kyo S., Hisagi M., Kinoshita O., Saito A., et al. Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis. J Artif Organs 2010, 13:197-201.
    • (2010) J Artif Organs , vol.13 , pp. 197-201
    • Nawata, K.1    Nishimura, T.2    Kyo, S.3    Hisagi, M.4    Kinoshita, O.5    Saito, A.6
  • 13
    • 67649770719 scopus 로고    scopus 로고
    • Patient-specific isogeometric fluid-structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device
    • Bazilevs Y., Gohean J.R., Hughes T.J.R., Moser R.D., Zhang Y. Patient-specific isogeometric fluid-structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device. Comput Methods Appl Mech Eng 2009, 198:3534-3550.
    • (2009) Comput Methods Appl Mech Eng , vol.198 , pp. 3534-3550
    • Bazilevs, Y.1    Gohean, J.R.2    Hughes, T.J.R.3    Moser, R.D.4    Zhang, Y.5
  • 14
    • 0037129864 scopus 로고    scopus 로고
    • Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    • Frazier O.H., Myers T.J., Gregoric I.D., Khan T., Delgado R., Croitoru M., et al. Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation 2002, 105:2855-2860.
    • (2002) Circulation , vol.105 , pp. 2855-2860
    • Frazier, O.H.1    Myers, T.J.2    Gregoric, I.D.3    Khan, T.4    Delgado, R.5    Croitoru, M.6
  • 15
    • 80054693130 scopus 로고    scopus 로고
    • Ventricular assist device outflow-graft site: effect on myocardial blood flow
    • Tuzun E., Narin C., Gregoric I.D., Cohn W.E., Frazier O.H. Ventricular assist device outflow-graft site: effect on myocardial blood flow. J Surg Res 2011, 171:71-75.
    • (2011) J Surg Res , vol.171 , pp. 71-75
    • Tuzun, E.1    Narin, C.2    Gregoric, I.D.3    Cohn, W.E.4    Frazier, O.H.5
  • 16
    • 79959265495 scopus 로고    scopus 로고
    • Less invasive off-pump implantation of axial flow pumps in chronic ischemic heart failure: survival effects
    • Ghodsizad A., Kar B.J., Layolka P., Okur A., Gonzales J., Bara C., et al. Less invasive off-pump implantation of axial flow pumps in chronic ischemic heart failure: survival effects. J Heart Lung Transpl 2011, 30:834-837.
    • (2011) J Heart Lung Transpl , vol.30 , pp. 834-837
    • Ghodsizad, A.1    Kar, B.J.2    Layolka, P.3    Okur, A.4    Gonzales, J.5    Bara, C.6
  • 17
    • 33744991763 scopus 로고    scopus 로고
    • Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta
    • May-Newman K., Hillen B., Dembitsky W. Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta. ASAIO J 2006, 52:132-139.
    • (2006) ASAIO J , vol.52 , pp. 132-139
    • May-Newman, K.1    Hillen, B.2    Dembitsky, W.3
  • 18
    • 77954508162 scopus 로고    scopus 로고
    • Numerical study of blood flow at the end-to-side anastomosis of a left ventricular assist device for adult patients
    • Yang N., Deutsch S., Paterson E.G., Manning K.B. Numerical study of blood flow at the end-to-side anastomosis of a left ventricular assist device for adult patients. J Biomech Eng 2009, 131:111005.
    • (2009) J Biomech Eng , vol.131 , pp. 111005
    • Yang, N.1    Deutsch, S.2    Paterson, E.G.3    Manning, K.B.4
  • 19
    • 77955109183 scopus 로고    scopus 로고
    • Hemodynamics of an end-to-side anastomotic graft for a pulsatile pediatric ventricular assist device
    • Yang N., Deutsch S., Paterson E.G., Manning K.B. Hemodynamics of an end-to-side anastomotic graft for a pulsatile pediatric ventricular assist device. J Biomech Eng 2010, 132:031009.
    • (2010) J Biomech Eng , vol.132 , pp. 031009
    • Yang, N.1    Deutsch, S.2    Paterson, E.G.3    Manning, K.B.4
  • 20
    • 24944570259 scopus 로고    scopus 로고
    • The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: implantation technique and computer flow modeling
    • Kar B., Delgado R.M., Frazier O.H., Gregoric I.D., Harting M.T., Wadia Y., et al. The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: implantation technique and computer flow modeling. Tex Heart Inst J 2005, 32:294-298.
    • (2005) Tex Heart Inst J , vol.32 , pp. 294-298
    • Kar, B.1    Delgado, R.M.2    Frazier, O.H.3    Gregoric, I.D.4    Harting, M.T.5    Wadia, Y.6
  • 21
    • 84861563059 scopus 로고    scopus 로고
    • Relationship between pump speed and exercise capacity during HeartMate II left ventricular assist device support: influence of residual left ventricular function
    • Noor M.R., Bowles C., Banner N.R. Relationship between pump speed and exercise capacity during HeartMate II left ventricular assist device support: influence of residual left ventricular function. Eur J Heart Fail 2012, 14:613-620.
    • (2012) Eur J Heart Fail , vol.14 , pp. 613-620
    • Noor, M.R.1    Bowles, C.2    Banner, N.R.3
  • 22
    • 84856379721 scopus 로고    scopus 로고
    • Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device
    • Brassard P., Jensen A.S., Nordsborg N., Gustafsson F., Møller J.E., Hassager C., et al. Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device. Circ Heart Fail 2011, 4:554-560.
    • (2011) Circ Heart Fail , vol.4 , pp. 554-560
    • Brassard, P.1    Jensen, A.S.2    Nordsborg, N.3    Gustafsson, F.4    Møller, J.E.5    Hassager, C.6
  • 23
    • 82255191801 scopus 로고    scopus 로고
    • Algorithms for the partitioned solution of weakly coupled fluid models for cardiovascular flows
    • Malossi A.C.I., Blanco P.J., Deparis S., Quarteroni A. Algorithms for the partitioned solution of weakly coupled fluid models for cardiovascular flows. Int J Num Methods Biomed Eng 2011, 27:2035-2057.
    • (2011) Int J Num Methods Biomed Eng , vol.27 , pp. 2035-2057
    • Malossi, A.C.I.1    Blanco, P.J.2    Deparis, S.3    Quarteroni, A.4
  • 24
    • 84862266042 scopus 로고    scopus 로고
    • A two-level time step technique for the partitioned solution of one-dimensional arterial networks
    • Malossi A.C.I., Blanco P.J., Deparis S. A two-level time step technique for the partitioned solution of one-dimensional arterial networks. Comput Methods Appl Mech Eng 2012, 237-240:212-226.
    • (2012) Comput Methods Appl Mech Eng , pp. 212-226
    • Malossi, A.C.I.1    Blanco, P.J.2    Deparis, S.3
  • 26
    • 33750694324 scopus 로고    scopus 로고
    • Interaction between carotid baroregulation and the pulsating heart: a mathematical model
    • Ursino M. Interaction between carotid baroregulation and the pulsating heart: a mathematical model. Am J Physiol Heart Circ Physiol 1998, 275:H1733-H1747.
    • (1998) Am J Physiol Heart Circ Physiol , vol.275
    • Ursino, M.1
  • 27
    • 0019079690 scopus 로고
    • Multi-branched model of the human arterial system
    • Avolio A.P. Multi-branched model of the human arterial system. Med Biol Eng Comput 1980, 18:709-718.
    • (1980) Med Biol Eng Comput , vol.18 , pp. 709-718
    • Avolio, A.P.1
  • 28
    • 0027006820 scopus 로고
    • Computer simulation of arterial flow with applications to arterial and aortic stenoses
    • Stergiopulos N., Young D.F., Rogge T.R. Computer simulation of arterial flow with applications to arterial and aortic stenoses. J Biomech 1992, 25:1477-1488.
    • (1992) J Biomech , vol.25 , pp. 1477-1488
    • Stergiopulos, N.1    Young, D.F.2    Rogge, T.R.3
  • 29
    • 84883148418 scopus 로고    scopus 로고
    • Olufsen MS. Modeling the arterial system with reference to an anesthesia simulator. PhD thesis, Roskilde University;
    • Olufsen MS. Modeling the arterial system with reference to an anesthesia simulator. PhD thesis, Roskilde University; 1998.
    • (1998)
  • 30
    • 0942268686 scopus 로고    scopus 로고
    • One-dimensional models for blood flow in arteries
    • Formaggia L., Lamponi D., Quarteroni A. One-dimensional models for blood flow in arteries. J Eng Math 2003, 47:251-276.
    • (2003) J Eng Math , vol.47 , pp. 251-276
    • Formaggia, L.1    Lamponi, D.2    Quarteroni, A.3
  • 31
    • 33745193927 scopus 로고    scopus 로고
    • A closed-loop lumped parameter computational model for human cardiovascular system
    • Liang F., Liu H. A closed-loop lumped parameter computational model for human cardiovascular system. JSME Int J 2005, 48:484-493.
    • (2005) JSME Int J , vol.48 , pp. 484-493
    • Liang, F.1    Liu, H.2
  • 32
    • 34247885810 scopus 로고    scopus 로고
    • Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows
    • Alastruey J., Parker K.H., Peiró J., Byrd S.M., Sherwin S.J. Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows. J Biomech 2007, 40:1794-1805.
    • (2007) J Biomech , vol.40 , pp. 1794-1805
    • Alastruey, J.1    Parker, K.H.2    Peiró, J.3    Byrd, S.M.4    Sherwin, S.J.5
  • 33
    • 78751646122 scopus 로고    scopus 로고
    • Black-box decomposition approach for computational hemodynamics: one-dimensional models
    • Blanco P.J., Leiva J.S., Feijóo R.A., Buscaglia G.C. Black-box decomposition approach for computational hemodynamics: one-dimensional models. Comput Methods Appl Mech Eng 2011, 200:1389-1405.
    • (2011) Comput Methods Appl Mech Eng , vol.200 , pp. 1389-1405
    • Blanco, P.J.1    Leiva, J.S.2    Feijóo, R.A.3    Buscaglia, G.C.4
  • 34
    • 0032932939 scopus 로고    scopus 로고
    • Total arterial inertance as the fourth element of the windkessel model
    • Stergiopulos N., Westerhof B., Westerhof N. Total arterial inertance as the fourth element of the windkessel model. Am J Physiol 1999, 276:H81-H88.
    • (1999) Am J Physiol , vol.276
    • Stergiopulos, N.1    Westerhof, B.2    Westerhof, N.3
  • 35
    • 0942290394 scopus 로고    scopus 로고
    • Systemic and pulmonary hemodynamics assessed with a lumped-parameter heart-arterial interaction model
    • Segers P., Stergiopulos N., Westerhof N., Wouters P., Kolh P., Verdonck P. Systemic and pulmonary hemodynamics assessed with a lumped-parameter heart-arterial interaction model. J Eng Math 2003, 47:185-199.
    • (2003) J Eng Math , vol.47 , pp. 185-199
    • Segers, P.1    Stergiopulos, N.2    Westerhof, N.3    Wouters, P.4    Kolh, P.5    Verdonck, P.6
  • 36
    • 4444259947 scopus 로고    scopus 로고
    • Analysis of lumped parameter models for blood flow simulations and their relation with 1D models
    • Milišić V., Quarteroni A. Analysis of lumped parameter models for blood flow simulations and their relation with 1D models. ESAIM: Math Model Numer Anal 2004, 38:613-632.
    • (2004) ESAIM: Math Model Numer Anal , vol.38 , pp. 613-632
    • Milišić, V.1    Quarteroni, A.2
  • 38
    • 33847288697 scopus 로고    scopus 로고
    • Model of arterial tree and peripheral control for the study of physiological and assisted circulation
    • Lanzarone E., Liani P., Baselli G., Constantino M.L. Model of arterial tree and peripheral control for the study of physiological and assisted circulation. Med Eng Phys 2007, 29:542-555.
    • (2007) Med Eng Phys , vol.29 , pp. 542-555
    • Lanzarone, E.1    Liani, P.2    Baselli, G.3    Constantino, M.L.4
  • 39
    • 79955104297 scopus 로고    scopus 로고
    • Review of Zero-D and 1-D models of blood flow in the cardiovascular system
    • Shi Y., Lawford P., Hose R. Review of Zero-D and 1-D models of blood flow in the cardiovascular system. Biomed Eng Online 2011, 10:1-38.
    • (2011) Biomed Eng Online , vol.10 , pp. 1-38
    • Shi, Y.1    Lawford, P.2    Hose, R.3
  • 42
    • 25444525523 scopus 로고    scopus 로고
    • Snapshots of hemodynamics: an aid for clinical research and graduate education
    • Springer-Verlag, New York
    • Westerhof N., Stergiopulos N., Noble M.I.M. Snapshots of hemodynamics: an aid for clinical research and graduate education. Basic science for the cardiologist 2010, Springer-Verlag, New York. 2nd ed.
    • (2010) Basic science for the cardiologist
    • Westerhof, N.1    Stergiopulos, N.2    Noble, M.I.M.3
  • 43
    • 0346059626 scopus 로고    scopus 로고
    • Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation
    • Koenig S.C., Pantalos G.M., Gillars K.J., Ewert D.L., Litwak K.N., Etoch S.W. Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation. ASAIO J 2004, 50:15-24.
    • (2004) ASAIO J , vol.50 , pp. 15-24
    • Koenig, S.C.1    Pantalos, G.M.2    Gillars, K.J.3    Ewert, D.L.4    Litwak, K.N.5    Etoch, S.W.6
  • 44
    • 46249083627 scopus 로고    scopus 로고
    • Preload sensitivity of the Jarvik 2000 and HeartMate II left ventricular assist devices
    • Khalil H.A., Cohn W.E., Metcalfe R.W., Frazier O.H. Preload sensitivity of the Jarvik 2000 and HeartMate II left ventricular assist devices. ASAIO J 2008, 54:245-248.
    • (2008) ASAIO J , vol.54 , pp. 245-248
    • Khalil, H.A.1    Cohn, W.E.2    Metcalfe, R.W.3    Frazier, O.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.