ARTICLE;
AUTOMATION;
CONTROLLED STUDY;
DATA ANALYSIS;
DATA EXTRACTION;
DATA PROCESSING;
ENZYME INHIBITION;
ENZYME INHIBITION ASSAY;
HIGH THROUGHPUT SCREENING;
HUMAN;
IC 50;
INFORMATION PROCESSING;
MASS SPECTROMETER;
MASS SPECTROMETRY;
PRIORITY JOURNAL;
SOLID PHASE EXTRACTION;
TANDEM MASS SPECTROMETRY;
WORKFLOW;
CHEMISTRY;
DRUG ANTAGONISM;
DRUG SCREENING;
METHODOLOGY;
CYTOCHROME P-450 ENZYME SYSTEM;
DRUG EVALUATION, PRECLINICAL;
ENZYME INHIBITORS;
HIGH-THROUGHPUT SCREENING ASSAYS;
INDICATORS AND REAGENTS;
INHIBITORY CONCENTRATION 50;
MASS SPECTROMETRY;
TRICHLOROACETIC ACID;
EID: 84883025662PISSN: 10643745EISSN: NoneSource Type: Book Series DOI: 10.1007/978-1-62703-321-3_3Document Type: Article
Drug MetabolismDrug Interaction Studies In The Drug Development Process: Studies In Vitro Accessed 10 Oct 2011
Drug Metabolism/Drug Interaction Studies in the Drug Development Process: Studies In Vitro (1997) http://www.fda.gov/downloads/Drugs/ GuidanceComplianceRegulatory Information/Guidances/UCM072104.pdf . Accessed 10 Oct 2011
(1997)
5
10744232330
The conduct of in vitro and in vivo drug-drug interaction studies: A pharmaceutical research and manufacturers of america (phrma) perspective
Bjornsson TD et al (2003) The conduct of in vitro and in vivo drug-drug interaction studies: A Pharmaceutical Research and Manufacturers of America (PhRMA) perspective. Drug Metab Dispos 31:815-832
Comparison of cytochrome p450 inhibition assays for drug discovery using human liver microsomes with lc-ms, rhcyp450 isozymes with fluorescence, and double cocktail with lc-ms
Di L, Kerns EH, Li SQ, Carter GT (2007) Comparison of cytochrome P450 inhibition assays for drug discovery using human liver microsomes with LC-MS, rhCYP450 isozymes with fluorescence, and double cocktail with LC-MS. Int J Pharm 335:1-11
Cytochrome p450 inhibition using recombinant proteins and mass spectrometry/multiple reaction monitoring technology in a cassette incubation
Weaver R, Graham KS, Beattie IG, Riley RJ (2003) Cytochrome P450 inhibition using recombinant proteins and mass spectrometry/multiple reaction monitoring technology in a cassette incubation. Drug Metab Dispos 31:955-966
Analytical approaches to determine cytochrome p450 inhibitory potential of new chemical entities in drug discovery
Smith D et al (2007) Analytical approaches to determine cytochrome P450 inhibitory potential of new chemical entities in drug discovery. J Chromatogr B 850:455-463
In vitro assessment of cytochrome p450 inhibition: Strategies for increasing lc/ms-based assay throughput using a one-point ic 50 method and multiplexing high-performance liquid chromatography
Lin T, Pan K, Mordenti J, Pan L (2007) In vitro assessment of cytochrome P450 inhibition: Strategies for increasing LC/MS-based assay throughput using a one-point IC 50 method and multiplexing high-performance liquid chromatography. J Pharm Sci 96:2485-2493
A high-capacity lc/ms system for the bioanalysis of samples generated from plate-based metabolic screening
Janiszewski JS et al (2001) A high-capacity LC/MS system for the bioanalysis of samples generated from plate-based metabolic screening. Anal Chem 73:1495-1501
Automated high throughput adme assays for metabolic stability and cytochrome p450 inhibition pro filing of combinatorial libraries
Jenkins KM et al (2004) Automated high throughput ADME assays for metabolic stability and cytochrome P450 inhibition pro filing of combinatorial libraries. J Pharm Biomed Anal 34:989-1004
High-throughput screening of inhibitory potential of nine cytochrome p450 enzymes in vitro using liquid chromatography/tandem mass spectrometry
Kim MJ et al (2005) High-throughput screening of inhibitory potential of nine cytochrome P450 enzymes in vitro using liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 19:2651-2658
Characterization and performance of maldi on a triple quadrupole mass spectrometer for analysis and quanti fication of small molecules
Gobey J et al (2005) Characterization and performance of MALDI on a triple quadrupole mass spectrometer for analysis and quanti fication of small molecules. Anal Chem 77:5643-5654
High-throughput cytochrome p450 inhibition assays using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry
Wu J et al (2007) High-throughput cytochrome P450 inhibition assays using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry. Anal Chem 79:4657-4665
Ms based cytochrome p450 inhibition screening during "hit-to- lead": Validation and automation
Lim KB, Chien EYT, Xu R, Kassel DB (2005) MS based cytochrome P450 inhibition screening during "hit-to-lead": validation and automation. Proceedings of the 53rd American Society for Mass Spectrometry Conference MP115
Development of a high-throughput online solid-phase extraction/tandem mass spectrometry method for cytochrome p450 inhibition screening
Lim KB, Ozbal CC, Kassel DB (2010) Development of a high-throughput online solid-phase extraction/tandem mass spectrometry method for cytochrome P450 inhibition screening. J Biomol Screen 15:447-452