메뉴 건너뛰기




Volumn 43, Issue 2, 2013, Pages 63-69

Patient radiation dose and protection from cone-beam computed tomography

Author keywords

Cone beam computed tomography; Radiation dosage; Radiation protection; Tomography, spiral computed

Indexed keywords


EID: 84882671124     PISSN: 22337822     EISSN: 22337830     Source Type: Journal    
DOI: 10.5624/isd.2013.43.2.63     Document Type: Article
Times cited : (120)

References (30)
  • 1
    • 0642310337 scopus 로고    scopus 로고
    • Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit.
    • Ludlow JB, Davies-Ludlow LE, Brooks SL. Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit. Dentomaxillofac Radiol 2003; 32: 229-34.
    • (2003) Dentomaxillofac Radiol , vol.32 , pp. 229-234
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    Brooks, S.L.3
  • 2
    • 5044251144 scopus 로고    scopus 로고
    • Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography.
    • Schulze D, Heiland M, Thurmann H, Adam G. Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofac Radiol 2004; 33: 83-6.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 83-86
    • Schulze, D.1    Heiland, M.2    Thurmann, H.3    Adam, G.4
  • 4
    • 33746041477 scopus 로고    scopus 로고
    • Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT.
    • Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 2006; 35: 219-26.
    • (2006) Dentomaxillofac Radiol , vol.35 , pp. 219-226
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    Brooks, S.L.3    Howerton, W.B.4
  • 5
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.
    • Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 106-14.
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 106-114
    • Ludlow, J.B.1    Ivanovic, M.2
  • 8
    • 48649089199 scopus 로고    scopus 로고
    • Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view.
    • Hirsch E, Wolf U, Heinicke F, Silva MA. Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view. Dentomaxillofac Radiol 2008; 37: 268-73.
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 268-273
    • Hirsch, E.1    Wolf, U.2    Heinicke, F.3    Silva, M.A.4
  • 9
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners.
    • Suomalainen A, Kiljunen T, Kaser Y, Peltola J, Kortesniemi M. Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners. Dentomaxillofac Radiol 2009; 38: 36778.
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 36778
    • Suomalainen, A.1    Kiljunen, T.2    Kaser, Y.3    Peltola, J.4    Kortesniemi, M.5
  • 10
    • 62849123566 scopus 로고    scopus 로고
    • Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography.
    • Chau AC, Fung K. Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: 559-65.
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.107 , pp. 559-565
    • Chau, A.C.1    Fung, K.2
  • 11
    • 58849163662 scopus 로고    scopus 로고
    • Effective dose from cone beam CT examinations in dentistry.
    • Roberts JA, Drage NA, Davies J, Thomas DW. Effective dose from cone beam CT examinations in dentistry. Br J Radiol 2009; 82: 35-40.
    • (2009) Br J Radiol , vol.82 , pp. 35-40
    • Roberts, J.A.1    Drage, N.A.2    Davies, J.3    Thomas, D.W.4
  • 12
    • 69949169325 scopus 로고    scopus 로고
    • Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications.
    • Loubele M, Bogaerts R, Van Dijck E, Pauwels R, Vanheusden S, Suetens P, et al. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 2009; 71: 461-8.
    • (2009) Eur J Radiol , vol.71 , pp. 461-468
    • Loubele, M.1    Bogaerts, R.2    Van Dijck, E.3    Pauwels, R.4    Vanheusden, S.5    Suetens, P.6
  • 13
    • 78649496644 scopus 로고    scopus 로고
    • Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols.
    • Qu XM, Li G, Ludlow JB, Zhang ZY, Ma XC. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 770-6.
    • (2010) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.110 , pp. 770-776
    • Qu, X.M.1    Li, G.2    Ludlow, J.B.3    Zhang, Z.Y.4    Ma, X.C.5
  • 15
    • 77953352476 scopus 로고    scopus 로고
    • Methods of determining the effective in dental radiology.
    • Thilander-Klang A, Helmrot E. Methods of determining the effective in dental radiology. Radiat Prot Dosimetry 2010; 139: 306-9.
    • (2010) Radiat Prot Dosimetry , vol.139 , pp. 306-309
    • Thilander-Klang, A.1    Helmrot, E.2
  • 16
    • 84855258711 scopus 로고    scopus 로고
    • Effective doses from cone beam CT investigation of the jaws.
    • Davies J, Johnson B, Drage NA. Effective doses from cone beam CT investigation of the jaws. Dentomaxillofac Radiol 2012; 41: 30-6.
    • (2012) Dentomaxillofac Radiol , vol.41 , pp. 30-36
    • Davies, J.1    Johnson, B.2    Drage, N.A.3
  • 17
    • 84859194744 scopus 로고    scopus 로고
    • Dosimetry of a cone-beam computed tomography machine compared with a digital x-ray machine in orthodontic imaging.
    • Grunheid T, Kolbeck Schieck JR, Pliska BT, Ahmad M, Larson BE. Dosimetry of a cone-beam computed tomography machine compared with a digital x-ray machine in orthodontic imaging. Am J Orthod Dentofacial Orthop 2012; 141: 436-43.
    • (2012) Am J Orthod Dentofacial Orthop , vol.141 , pp. 436-443
    • Grunheid, T.1    Kolbeck Schieck, J.R.2    Pliska, B.T.3    Ahmad, M.4    Larson, B.E.5
  • 19
    • 84882701975 scopus 로고    scopus 로고
    • Radiation protection No 172. Cone beam CT for dental and maxillofacial radiology. Evidence based guidelines
    • SEDENTEXCT Guideline Development Panel
    • SEDENTEXCT Guideline Development Panel. Radiation protection No 172. Cone beam CT for dental and maxillofacial radiology. Evidence based guidelines. Luxembourg: European Comminssion Directorate-General for Energy; 2012.
    • (2012) Luxembourg: European Comminssion Directorate-General for Energy
  • 20
    • 0034132559 scopus 로고    scopus 로고
    • Effective dose from radiation absorbed during a panoramic examination with a new generation machine.
    • Danforth RA, Clark DE. Effective dose from radiation absorbed during a panoramic examination with a new generation machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 89: 236-43.
    • (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.89 , pp. 236-243
    • Danforth, R.A.1    Clark, D.E.2
  • 23
    • 52749087498 scopus 로고    scopus 로고
    • Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation.
    • Ludlow JB, Davies-Ludlow LE, White SC. Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation. J Am Dent Assoc 2008; 139: 1237-43.
    • (2008) J Am Dent Assoc , vol.139 , pp. 1237-1243
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    White, S.C.3
  • 24
    • 0035374728 scopus 로고    scopus 로고
    • Dose reduction by direct-digital cephalometric radiography.
    • Visser H, Rodig T, Hermann KP. Dose reduction by direct-digital cephalometric radiography. Angle Orthod 2001; 71: 159-63.
    • (2001) Angle Orthod , vol.71 , pp. 159-163
    • Visser, H.1    Rodig, T.2    Hermann, K.P.3
  • 25
  • 26
    • 0034292806 scopus 로고    scopus 로고
    • Effective dose equivalent and effective dose: comparison for common projections in oral and maxillofacial radiology.
    • Gibbs SJ. Effective dose equivalent and effective dose: comparison for common projections in oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 90: 538-45.
    • (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.90 , pp. 538-545
    • Gibbs, S.J.1
  • 27
    • 84991210524 scopus 로고    scopus 로고
    • Comparative dosimetry of dental cone-beam computed tomography and multislice computed tomography for oral and maxillofacial radiology.
    • Qu XM, Li G, Zhang ZY, Ma XC. Comparative dosimetry of dental cone-beam computed tomography and multislice computed tomography for oral and maxillofacial radiology. Zhonghua Kou Qiang Yi Xue Za Zhi 2011; 46: 595-9.
    • (2011) Zhonghua Kou Qiang Yi Xue Za Zhi , vol.46 , pp. 595-599
    • Qu, X.M.1    Li, G.2    Zhang, Z.Y.3    Ma, X.C.4
  • 28
    • 84863607989 scopus 로고    scopus 로고
    • Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars
    • Qu XM, Li G, Sanderink GC, Zhang ZY, Ma XC. Dose reduction of cone beam CT scanning for the entire oral and maxillofacial regions with thyroid collars. Dentomaxillofac Radiol 2012: 41: 373-8.
    • (2012) Dentomaxillofac Radiol , vol.41 , pp. 373-378
    • Qu, X.M.1    Li, G.2    Sanderink, G.C.3    Zhang, Z.Y.4    Ma, X.C.5
  • 29
    • 84856949019 scopus 로고    scopus 로고
    • Thyroid shields for radiation dose reduction during cone beam computed tomography scanning for different oral and maxillofacial regions
    • Qu X, Li G, Zhang Z, Ma X. Thyroid shields for radiation dose reduction during cone beam computed tomography scanning for different oral and maxillofacial regions. Eur J Radiol 2012; 81: e376-80.
    • (2012) Eur J Radiol , vol.81
    • Qu, X.1    Li, G.2    Zhang, Z.3    Ma, X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.