메뉴 건너뛰기




Volumn 26, Issue 9, 2013, Pages 1070-1078

Improved Bloch-Siegert based B1 mapping by reducing off-resonance shift

Author keywords

B1 mapping; Flip angle; High field MRI; Transmit sense; Wavelength effects

Indexed keywords

ESTIMATION ERRORS; FLIP ANGLE; HIGH FIELD MRI; IN-VIVO EXPERIMENTS; IRRADIATION PULSE; MAPPING SENSITIVITY; TRANSMIT SENSE; WAVELENGTH EFFECTS;

EID: 84882268901     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.2920     Document Type: Article
Times cited : (17)

References (26)
  • 1
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult DI, Phil D. Sensitivity and power deposition in a high-field imaging experiment. J. Magn. Reson. Imaging 2000; 12(1): 46-67.
    • (2000) J. Magn. Reson. Imaging , vol.12 , Issue.1 , pp. 46-67
    • Hoult, D.I.1    Phil, D.2
  • 2
    • 80054803017 scopus 로고    scopus 로고
    • Fast radiofrequency flip angle calibration by Bloch-Siegert shift
    • Sacolick LI, Sun L, Vogel MW, Dixon WT, Hancu I. Fast radiofrequency flip angle calibration by Bloch-Siegert shift. Magn. Reson. Med. 2011; 66(5): 1333-1338.
    • (2011) Magn. Reson. Med. , vol.66 , Issue.5 , pp. 1333-1338
    • Sacolick, L.I.1    Sun, L.2    Vogel, M.W.3    Dixon, W.T.4    Hancu, I.5
  • 3
    • 1842586446 scopus 로고    scopus 로고
    • Parallel excitation with an array of transmit coils
    • Zhu Y. Parallel excitation with an array of transmit coils. Magn. Reson. Med. 2004; 51(4): 775-784.
    • (2004) Magn. Reson. Med. , vol.51 , Issue.4 , pp. 775-784
    • Zhu, Y.1
  • 6
    • 5844348565 scopus 로고
    • Magnetic resonance for nonrotating fields
    • Bloch F, Siegert A. Magnetic resonance for nonrotating fields. Phys. Rev. 1940; 57(6): 522-527.
    • (1940) Phys. Rev. , vol.57 , Issue.6 , pp. 522-527
    • Bloch, F.1    Siegert, A.2
  • 8
    • 84355163073 scopus 로고    scopus 로고
    • Integrated Bloch-Siegert B1 mapping and multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heart
    • Lau AZ, Chen AP, Cunningham CH. Integrated Bloch-Siegert B1 mapping and multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heart. Magn. Reson. Med. 2012; 67(1): 62-71.
    • (2012) Magn. Reson. Med. , vol.67 , Issue.1 , pp. 62-71
    • Lau, A.Z.1    Chen, A.P.2    Cunningham, C.H.3
  • 9
    • 84882242796 scopus 로고    scopus 로고
    • Interference Bloch-Siegert B1 Mapping for Parallel Transmit. 19th Annual Meeting & Exhibition of ISMRM. Montreal, Canada;.
    • Sacolick L, Grissom WA, Kudielka G, Loew W, Vogel MW. Interference Bloch-Siegert B1 Mapping for Parallel Transmit. 19th Annual Meeting & Exhibition of ISMRM. Montreal, Canada; 2011, p 2926.
    • (2011) , pp. 2926
    • Sacolick, L.1    Grissom, W.A.2    Kudielka, G.3    Loew, W.4    Vogel, M.W.5
  • 10
    • 84857243554 scopus 로고    scopus 로고
    • Tailored excitation using nonlinear B0-shims
    • Duan Q, van Gelderen P, Duyn J. Tailored excitation using nonlinear B0-shims. Magn. Reson. Med. 2012; 67(3): 601-608.
    • (2012) Magn. Reson. Med. , vol.67 , Issue.3 , pp. 601-608
    • Duan, Q.1    van Gelderen, P.2    Duyn, J.3
  • 11
    • 84878114691 scopus 로고    scopus 로고
    • Optimum coupling and multimode excitation of traveling-waves in a whole-body 9.4T scanner
    • DOI: 10.1002/mrm.24403
    • Geschewski FH, Brenner D, Felder J, Jon Shah N. Optimum coupling and multimode excitation of traveling-waves in a whole-body 9.4T scanner. Magn. Reson. Med. DOI: 10.1002/mrm.24403.
    • Magn. Reson. Med.
    • Geschewski, F.H.1    Brenner, D.2    Felder, J.3    Jon Shah, N.4
  • 13
    • 84882238172 scopus 로고    scopus 로고
    • FDA. Guidance for Industry and FDA Staff: Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Radiological Devices Branch, Division of Reproductive, Abdominal, and Radiological Devices, Office of Device Evaluation; .
    • FDA. Guidance for Industry and FDA Staff: Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Radiological Devices Branch, Division of Reproductive, Abdominal, and Radiological Devices, Office of Device Evaluation; 2003.
    • (2003)
  • 14
    • 84882268358 scopus 로고    scopus 로고
    • Fast B1 Mapping using a STEAM-based Bloch-Siegert Preparation Pulse. 19th Annual Meeting & Exhibition of ISMRM. Montreal, CA;
    • Nehrke K, Bornert P. Fast B1 Mapping using a STEAM-based Bloch-Siegert Preparation Pulse. 19th Annual Meeting & Exhibition of ISMRM. Montreal, CA; 2011, p4411.
    • (2011) , pp. 4411
    • Nehrke, K.1    Bornert, P.2
  • 15
    • 84882245785 scopus 로고    scopus 로고
    • Fast Spin Echo Bloch-Siegert B1 Mapping. 19th Annual Meeting & Exhibition of ISMRM. Montreal, Canada;
    • Sacolick L, Lee S-K, Grissom WA, Vogel MW. Fast Spin Echo Bloch-Siegert B1 Mapping. 19th Annual Meeting & Exhibition of ISMRM. Montreal, Canada; 2011, p 2927.
    • (2011) , pp. 2927
    • Sacolick, L.1    Lee, S.-K.2    Grissom, W.A.3    Vogel, M.W.4
  • 18
    • 84865504577 scopus 로고    scopus 로고
    • RF pulse optimization for Bloch-Siegert B +1 mapping
    • Khalighi MM, Rutt BK, Kerr AB. RF pulse optimization for Bloch-Siegert B +1 mapping. Magn. Reson. Med. 2012; 68(3): 857-862.
    • (2012) Magn. Reson. Med. , vol.68 , Issue.3 , pp. 857-862
    • Khalighi, M.M.1    Rutt, B.K.2    Kerr, A.B.3
  • 19
    • 84882285808 scopus 로고    scopus 로고
    • Implementation and Validation of Fast Whole-Brain B1 Mapping Based on Bloch-Siegert Shift and EPI Readout. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia;
    • Duan Q, Inati S, van Gelderen P, Patil S, Duyn J. Implementation and Validation of Fast Whole-Brain B1 Mapping Based on Bloch-Siegert Shift and EPI Readout. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia; 2012, p 609.
    • (2012) , pp. 609
    • Duan, Q.1    Inati, S.2    van Gelderen, P.3    Patil, S.4    Duyn, J.5
  • 20
    • 84882279533 scopus 로고    scopus 로고
    • Fast Simultaneous B0/B1 Mapping by Bloch-Siegert Shift with Improved Gradient Scheme and Pulse Design. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia;
    • Duan Q, van Gelderen P, Duyn J. Fast Simultaneous B0/B1 Mapping by Bloch-Siegert Shift with Improved Gradient Scheme and Pulse Design. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia; 2012, p 2504.
    • (2012) , pp. 2504
    • Duan, Q.1    van Gelderen, P.2    Duyn, J.3
  • 22
    • 0007951644 scopus 로고
    • Resonance transitions induced by perturbations at two or more different frequencies
    • Ramsey NF. Resonance transitions induced by perturbations at two or more different frequencies. Phys. Rev. 1955; 100(4): 1191-1194.
    • (1955) Phys. Rev. , vol.100 , Issue.4 , pp. 1191-1194
    • Ramsey, N.F.1
  • 23
    • 84882277122 scopus 로고    scopus 로고
    • Adiabatic Pulse Design for Bloch-Siegert B1+ Mapping. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia;
    • Khalighi MM, Rutt BK, Kerr AB. Adiabatic Pulse Design for Bloch-Siegert B1+ Mapping. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia; 2012, p 607.
    • (2012) , pp. 607
    • Khalighi, M.M.1    Rutt, B.K.2    Kerr, A.B.3
  • 24
    • 84882278153 scopus 로고    scopus 로고
    • Saturation Pulse Design with Explicit Sensitivity Maximization for Bloch-Siegert B1+ Mapping. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia;
    • Jankiewicz M, Gore JC, Grissom WA. Saturation Pulse Design with Explicit Sensitivity Maximization for Bloch-Siegert B1+ Mapping. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia; 2012, p 3362.
    • (2012) , pp. 3362
    • Jankiewicz, M.1    Gore, J.C.2    Grissom, W.A.3
  • 25
    • 84882249865 scopus 로고    scopus 로고
    • Very fast volumetric B1+ mapping at 7 Tesla using DREAM. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia;
    • Börnert P, Nehrke K, Versluis M, Webb A. Very fast volumetric B1+ mapping at 7 Tesla using DREAM. 20th Annual Meeting & Exhibition of ISMRM. Melbourne, Australia; 2012, p 606.
    • (2012) , pp. 606
    • Börnert, P.1    Nehrke, K.2    Versluis, M.3    Webb, A.4
  • 26
    • 84867890773 scopus 로고    scopus 로고
    • DREAM-a novel approach for robust, ultrafast, multislice B(1) mapping
    • Nehrke K, Bornert P. DREAM-a novel approach for robust, ultrafast, multislice B(1) mapping. Magn. Reson. Med. 2012; 68(5): 1517-1526.
    • (2012) Magn. Reson. Med. , vol.68 , Issue.5 , pp. 1517-1526
    • Nehrke, K.1    Bornert, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.