Volumn 66, Issue 5, 2011, Pages 1333-1338

Fast radiofrequency flip angle calibration by Bloch-Siegert shift

Author keywords

Bloch Siegert shift; flip angle; off resonance; RF calibration; transmit gain

Indexed keywords

RESONANCE;

EID: 80054803017     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22902     Document Type: Article
Times cited : (17)

References (17)
  • 2
    • 0030066913 scopus 로고    scopus 로고
    • Calibration of the radio frequency field for magnetic resonance imaging
    • Foxall DL, Hoppel BE,. Calibration of the radio frequency field for magnetic resonance imaging. Magn Reson Med 1996; 35: 229-236.
    • (1996) Magn Reson Med , vol.35 , pp. 229-236
    • Foxall, D.L.1    Hoppel, B.E.2
  • 4
    • 0025160242 scopus 로고
    • Rapid radio frequency calibration in MRI
    • Carlson JW, Kramer DM,. Rapid radio frequency calibration in MRI. Magn Reson Med 1990; 15: 438-445.
    • (1990) Magn Reson Med , vol.15 , pp. 438-445
    • Carlson, J.W.1    Kramer, D.M.2
  • 5
    • 51449114690 scopus 로고    scopus 로고
    • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI
    • Helms G, Finsterbusch J, Weiskopf N, Dechent P,. Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI. Magn Reson Med 2008; 60: 739-743.
    • (2008) Magn Reson Med , vol.60 , pp. 739-743
    • Helms, G.1    Finsterbusch, J.2    Weiskopf, N.3    Dechent, P.4
  • 6
    • 33845263696 scopus 로고    scopus 로고
    • Fast 3D radiofrequency field mapping using echo-planar imaging
    • Jiru F, Klose U,. Fast 3D radiofrequency field mapping using echo-planar imaging. Magn Reson Med 2006; 56: 1375-1379.
    • (2006) Magn Reson Med , vol.56 , pp. 1375-1379
    • Jiru, F.1    Klose, U.2
  • 7
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Yarnykh VL,. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200.
    • (2007) Magn Reson Med , vol.57 , pp. 192-200
    • Yarnykh, V.L.1
  • 8
    • 36348998721 scopus 로고    scopus 로고
    • Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null
    • Dowell NG, Tofts PS,. Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null. Magn Reson Med 2007; 58: 622-630.
    • (2007) Magn Reson Med , vol.58 , pp. 622-630
    • Dowell, N.G.1    Tofts, P.S.2
  • 10
    • 53549085458 scopus 로고    scopus 로고
    • A phase-sensitive method of flip angle mapping
    • Morrell GR,. A phase-sensitive method of flip angle mapping. Magn Reson Med 2008; 60: 889-894.
    • (2008) Magn Reson Med , vol.60 , pp. 889-894
    • Morrell, G.R.1
  • 13
    • 0007951644 scopus 로고
    • Resonance transitions induced by perturbations at two or more different frequencies
    • Ramsey NF,. Resonance transitions induced by perturbations at two or more different frequencies. Phys Rev 1955; 100: 1191-1194.
    • (1955) Phys Rev , vol.100 , pp. 1191-1194
    • Ramsey, N.F.1
  • 16
    • 74049093102 scopus 로고    scopus 로고
    • B1 transmission-field inhomogeneity and enhancement ratio errors in dynamic contrast-enhanced MRI (DCE-MRI) of the breast at 3T
    • Azlan CA, Di Giovanni P, Ahearn TS, Semple SI, Gilbert FJ, Redpath TW,. B1 transmission-field inhomogeneity and enhancement ratio errors in dynamic contrast-enhanced MRI (DCE-MRI) of the breast at 3T. J Magn Reson Imaging 2010; 31: 234-239.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 234-239
    • Azlan, C.A.1    Di Giovanni, P.2    Ahearn, T.S.3    Semple, S.I.4    Gilbert, F.J.5    Redpath, T.W.6
  • 17
    • 73349142956 scopus 로고    scopus 로고
    • Improved signal to noise in proton spectroscopy of the human calf muscle at 7T using localized B1 calibration
    • Versluis MJ, Kan HE, van Buchem MA, Webb AG,. Improved signal to noise in proton spectroscopy of the human calf muscle at 7T using localized B1 calibration. Magn Reson Med 2010; 63: 207-211.
    • (2010) Magn Reson Med , vol.63 , pp. 207-211
    • Versluis, M.J.1    Kan, H.E.2    Van Buchem, M.A.3    Webb, A.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.