-
1
-
-
77955289545
-
B1 mapping by Bloch-Siegert shift
-
Sacolick LI, Wiesinger F, Hancu I, Vogel MW,. B1 mapping by Bloch-Siegert shift. Magn Reson Med 2010; 63: 1315-1322.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1315-1322
-
-
Sacolick, L.I.1
Wiesinger, F.2
Hancu, I.3
Vogel, M.W.4
-
2
-
-
5844348565
-
Magentic resonance for nonrotating fields
-
Bloch F, Siegert A,. Magentic resonance for nonrotating fields. Phys Rev 1940; 57: 522-527.
-
(1940)
Phys Rev
, vol.57
, pp. 522-527
-
-
Bloch, F.1
Siegert, A.2
-
3
-
-
0007951644
-
Resonance transitions induced by perturbations at two or more different frequencies
-
Ramsey NF,. Resonance transitions induced by perturbations at two or more different frequencies. Phys Rev 1955; 100: 1191-1194.
-
(1955)
Phys Rev
, vol.100
, pp. 1191-1194
-
-
Ramsey, N.F.1
-
6
-
-
33847534249
-
Effects of diffusion on free precession in nuclear magnetic resonance experiments
-
Carr HY, Purcell EM,. Effects of diffusion on free precession in nuclear magnetic resonance experiments. Phys Rev 1954; 94: 630-638.
-
(1954)
Phys Rev
, vol.94
, pp. 630-638
-
-
Carr, H.Y.1
Purcell, E.M.2
-
7
-
-
0002899752
-
Modified spin-echo method for measuring nuclear relaxation times
-
Meiboom S, Gill D,. Modified spin-echo method for measuring nuclear relaxation times. Rev Sci Instrum 1958; 29: 688-691.
-
(1958)
Rev Sci Instrum
, vol.29
, pp. 688-691
-
-
Meiboom, S.1
Gill, D.2
-
8
-
-
80054058303
-
Transmit gain calibration for nonproton MR using the Bloch-Siegert shift
-
DOI: 10.1002/nbm.1657
-
Schulte RF, Sacolick L, Deppe MH, Janich MA, Schwaiger M, Wild JM, Wiesinger F,. Transmit gain calibration for nonproton MR using the Bloch-Siegert shift. NMR Biomed. DOI: 10.1002/nbm.1657.
-
NMR Biomed.
-
-
Schulte, R.F.1
Sacolick, L.2
Deppe, M.H.3
Janich, M.A.4
Schwaiger, M.5
Wild, J.M.6
Wiesinger, F.7
-
9
-
-
0031300505
-
Theoretical Evaluation and Comparison of Fast Chemical Shift Imaging Methods
-
Pohmann R, von Kienlin M, Haase A,. Theoretical evaluation and comparison of fast chemical shift imaging methods. J Magn Reson 1997; 129: 145-160. (Pubitemid 127451427)
-
(1997)
Journal of Magnetic Resonance
, vol.129
, Issue.2
, pp. 145-160
-
-
Pohmann, R.1
Von Kienlin, M.2
Haase, A.3
-
10
-
-
85012711620
-
-
Waugh J.S. editor. Advances in magnetic resonance, New York: Academic Press
-
Ernst RR,. Sensitivity enhancement in magnetic resonance. In:, Waugh JS, editor. Advances in magnetic resonance, vol. 2. New York: Academic Press; 1966. pp 1-135.
-
(1966)
Sensitivity Enhancement in Magnetic Resonance
, vol.2
, pp. 1-135
-
-
Ernst, R.R.1
-
11
-
-
49549152442
-
Optimum filtering for sensitivity enhancement in magnetic resonance
-
Buckmaster HA, Cohn-Sfetcu S, Fry DJI, Optimum filtering for sensitivity enhancement in magnetic resonance, J Magn Reson 1974; 14: 296-301.
-
(1974)
J Magn Reson
, vol.14
, pp. 296-301
-
-
Buckmaster, H.A.1
Cohn-Sfetcu, S.2
Fry, D.J.I.3
-
12
-
-
0028839871
-
The rician distribution of noisy MRI data
-
Gudbjartsson H, Patz S,. The rician distribution of noisy MRI data. Magn Reson Med 1995; 34: 910-914.
-
(1995)
Magn Reson Med
, vol.34
, pp. 910-914
-
-
Gudbjartsson, H.1
Patz, S.2
-
13
-
-
0000811634
-
Multiecho imaging sequences with low refocusing flip angles
-
Hennig J,. Multiecho imaging sequences with low refocusing flip angles. J Magn Reson 1988; 78: 397-407.
-
(1988)
J Magn Reson
, vol.78
, pp. 397-407
-
-
Hennig, J.1
-
14
-
-
0037373303
-
Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS)
-
DOI 10.1002/mrm.10391
-
Hennig J, Weigel M, Scheffler K,. Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS). Magn Reson Med 2003; 49: 527-535. (Pubitemid 36262821)
-
(2003)
Magnetic Resonance in Medicine
, vol.49
, Issue.3
, pp. 527-535
-
-
Hennig, J.1
Weigel, M.2
Scheffler, K.3
|