Volumn 471, Issue 9, 2013, Pages 2987-2994

Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULAR COMPONENT ORIENTATION; ADULT; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HIP RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ACCURACY; MUSCULOSKELETAL SYSTEM PARAMETERS; PLAIN ANTEROPOSTERIOR RADIOGRAPHY; PRIORITY JOURNAL; RADIOGRAPHIC ANTEVERSION ANGLE; RADIOGRAPHIC INCLINATION ANGLE; RADIOLOGICAL PARAMETERS; RELIABILITY; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS; VALIDATION PROCESS;

EID: 84881661934     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-013-3021-8     Document Type: Article
Times cited : (91)

References (30)
  • 1
    • 0022489328 scopus 로고
    • Anteversion of the acetabular cup: Measurement of angle after total hip replacement
    • 3733807 1:STN:280:DyaL283nvVeitA%3D%3D
    • Ackland MK, Bourne WB, Uhthoff HK. Anteversion of the acetabular cup: measurement of angle after total hip replacement. J Bone Joint Surg Br. 1986;68:409-413.
    • (1986) J Bone Joint Surg Br. , vol.68 , pp. 409-413
    • Ackland, M.K.1    Bourne, W.B.2    Uhthoff, H.K.3
  • 2
    • 38949157778 scopus 로고    scopus 로고
    • The rationale for tilt-adjusted acetabular cup navigation
    • 18245596 10.2106/JBJS.F.00628
    • Babisch JW, Layher F, Amiot LP. The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am. 2008;90:357-365.
    • (2008) J Bone Joint Surg Am. , vol.90 , pp. 357-365
    • Babisch, J.W.1    Layher, F.2    Amiot, L.P.3
  • 3
    • 0035205987 scopus 로고    scopus 로고
    • Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty
    • 11689370 10.1016/S0030-5898(05)70227-3 1:STN:280:DC%2BD3MnktVWrtQ%3D%3D
    • Barrack RL, Lavernia C, Ries M, Thornberry R, Tozakoglou E. Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. Orthop Clin North Am. 2001;32:569-579.
    • (2001) Orthop Clin North Am. , vol.32 , pp. 569-579
    • Barrack, R.L.1    Lavernia, C.2    Ries, M.3    Thornberry, R.4    Tozakoglou, E.5
  • 6
    • 69249214257 scopus 로고    scopus 로고
    • Della Valle AG. CT outperforms radiography for determination of acetabular cup version after THA
    • 19277802 10.1007/s11999-009-0774-1
    • Ghelman B, Kepler CK, Lyman S, Della Valle AG. CT outperforms radiography for determination of acetabular cup version after THA. Clin Orthop Relat Res. 2009;467:2362-2370.
    • (2009) Clin Orthop Relat Res. , vol.467 , pp. 2362-2370
    • Ghelman, B.1    Kepler, C.K.2    Lyman, S.3
  • 7
    • 0016613131 scopus 로고
    • Evaluation of acetabular anteversion following total hip arthroplasty: Necessity of proper centering
    • 1131483 10.1259/0007-1285-48-568-259 1:STN:280:DyaE2M7msFGmsQ%3D%3D
    • Goergen TG, Resnick D. Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centering. Br J Radiol. 1975;48:259-260.
    • (1975) Br J Radiol. , vol.48 , pp. 259-260
    • Goergen, T.G.1    Resnick, D.2
  • 8
    • 0028999144 scopus 로고
    • Radiographic calculation of anteversion in acetabular prostheses
    • 7673917 10.1016/S0883-5403(05)80187-1 1:STN:280:DyaK2MvgsVajsA%3D%3D
    • Hassan DM, Johnston GH, Dust WN, Watson LG, Cassidy D. Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty. 1995;10:369-372.
    • (1995) J Arthroplasty. , vol.10 , pp. 369-372
    • Hassan, D.M.1    Johnston, G.H.2    Dust, W.N.3    Watson, L.G.4    Cassidy, D.5
  • 9
    • 0036220260 scopus 로고    scopus 로고
    • Factors predisposing to dislocation after primary total hip prosthesis
    • 11938502 10.1054/arth.2002.30286 1:STN:280:DC%2BD383gsVOlug%3D%3D
    • Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip prosthesis. J Arthroplasty. 2002;17:282-288.
    • (2002) J Arthroplasty. , vol.17 , pp. 282-288
    • Jolles, B.M.1    Zangger, P.2    Leyvraz, P.F.3
  • 10
    • 33646079156 scopus 로고    scopus 로고
    • Position of the acetabular cup: Accuracy of radiographic calculation compared to CT-based measurement
    • 16289687 10.1016/j.ejrad.2005.10.003
    • Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J. Position of the acetabular cup: accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol. 2006;58:294-300.
    • (2006) Eur J Radiol. , vol.58 , pp. 294-300
    • Kalteis, T.1    Handel, M.2    Herold, T.3    Perlick, L.4    Paetzel, C.5    Grifka, J.6
  • 11
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • 10.1016/S0883-5403(98)90052-3
    • Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998;5:530-534.
    • (1998) J Arthroplasty. , vol.5 , pp. 530-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3    Sullivan, R.J.4    Griffen, D.G.5    Sheehan, L.J.6
  • 12
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • 843571 10.2307/2529310 1:STN:280:DyaE2s7jsFWqtA%3D%3D
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.
    • (1977) Biometrics. , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 14
    • 33749449658 scopus 로고    scopus 로고
    • A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs
    • 16721351 10.1097/01.blo.0000223988.41776.fa
    • Liaw CK, Hou SM, Yang RS, Wu TY, Fuh CS. A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs. Clin Orthop Relat Res. 2006;451:134-139.
    • (2006) Clin Orthop Relat Res. , vol.451 , pp. 134-139
    • Liaw, C.K.1    Hou, S.M.2    Yang, R.S.3    Wu, T.Y.4    Fuh, C.S.5
  • 15
    • 49649103408 scopus 로고    scopus 로고
    • Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: A cadaver study
    • 18541352 10.1016/j.clinbiomech.2008.04.015
    • Lin F, Lim D, Wixson RL, Milos S, Hendrix RW, Makhsous M. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study. Clin Biomech (Bristol, Avon). 2008;23:1004-1011.
    • (2008) Clin Biomech (Bristol, Avon). , vol.23 , pp. 1004-1011
    • Lin, F.1    Lim, D.2    Wixson, R.L.3    Milos, S.4    Hendrix, R.W.5    Makhsous, M.6
  • 16
    • 77954659964 scopus 로고    scopus 로고
    • A validation model for measurement of acetabular component position
    • 19553075 10.1016/j.arth.2009.04.021
    • Malik A, Wan Z, Jaramaz B, Bowman G, Dorr LD. A validation model for measurement of acetabular component position. J Arthroplasty. 2010;25:812-819.
    • (2010) J Arthroplasty. , vol.25 , pp. 812-819
    • Malik, A.1    Wan, Z.2    Jaramaz, B.3    Bowman, G.4    Dorr, L.D.5
  • 17
    • 33746878867 scopus 로고    scopus 로고
    • Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    • 16810554 10.1007/s00402-006-0163-0
    • Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G. Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg. 2006;126:487-492.
    • (2006) Arch Orthop Trauma Surg. , vol.126 , pp. 487-492
    • Marx, A.1    Von Knoch, M.2    Pförtner, J.3    Wiese, M.4    Saxler, G.5
  • 18
    • 0014733880 scopus 로고
    • Anatomical factors in the stability of the hip joint in the newborn
    • 5436200 1:STN:280:DyaE3c7ltFantQ%3D%3D
    • McKibbin B. Anatomical factors in the stability of the hip joint in the newborn. J Bone Joint Surg Br. 1970;52:148-159.
    • (1970) J Bone Joint Surg Br. , vol.52 , pp. 148-159
    • McKibbin, B.1
  • 19
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • 8444942 1:STN:280:DyaK3s7os1yrug%3D%3D
    • Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993;75:228-232.
    • (1993) J Bone Joint Surg Br. , vol.75 , pp. 228-232
    • Murray, D.W.1
  • 22
    • 80053199484 scopus 로고    scopus 로고
    • A reliability study of measurement tools available on standard picture archiving and communication system workstations for the evaluation of hip radiographs following arthroplasty
    • 21938375 10.2106/JBJS.J.00709
    • Patel SR, Toms AP, Rehman JM, Wimhurst J. A reliability study of measurement tools available on standard picture archiving and communication system workstations for the evaluation of hip radiographs following arthroplasty. J Bone Joint Surg Am. 2011;93:1712-1719.
    • (2011) J Bone Joint Surg Am. , vol.93 , pp. 1712-1719
    • Patel, S.R.1    Toms, A.P.2    Rehman, J.M.3    Wimhurst, J.4
  • 23
    • 0033050961 scopus 로고    scopus 로고
    • Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs
    • 10872360 10.1302/0301-620X.81B3.9067 1:STN:280:DC%2BD3czjtFWltg%3D%3D
    • Pradhan R. Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br. 1999;81:431-435.
    • (1999) J Bone Joint Surg Br. , vol.81 , pp. 431-435
    • Pradhan, R.1
  • 25
    • 0019409414 scopus 로고
    • A new method for measuring angles after total hip arthroplasty: A study of the acetabular cup and femoral component
    • Visser JD, Konings JG. A new method for measuring angles after total hip arthroplasty: a study of the acetabular cup and femoral component. J Bone Joint Surg Br. 1981;63:556-559.
    • (1981) J Bone Joint Surg Br. , vol.63 , pp. 556-559
    • Visser, J.D.1    Konings, J.G.2
  • 26
    • 58249092132 scopus 로고    scopus 로고
    • Imaging and navigation measurement of acetabular component position in THA
    • 18979147 10.1007/s11999-008-0597-5
    • Wan Z, Malik A, Jaramaz B, Chao L, Dorr LD. Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res. 2009;467:32-42.
    • (2009) Clin Orthop Relat Res. , vol.467 , pp. 32-42
    • Wan, Z.1    Malik, A.2    Jaramaz, B.3    Chao, L.4    Dorr, L.D.5
  • 27
    • 79952199881 scopus 로고    scopus 로고
    • 3D CT analysis of combined cup and stem anteversion in cases of cup navigation in hip arthroplasty
    • 20954630 10.3928/01477447-20100510-53
    • Wassilew GI, Perka C, Koenig C, Janz V, Asbach P, Hasart O. 3D CT analysis of combined cup and stem anteversion in cases of cup navigation in hip arthroplasty. Orthopedics. 2010;33(Suppl):48-51.
    • (2010) Orthopedics. , vol.33 , Issue.SUPPL. , pp. 48-51
    • Wassilew, G.I.1    Perka, C.2    Koenig, C.3    Janz, V.4    Asbach, P.5    Hasart, O.6
  • 28
    • 1942422237 scopus 로고    scopus 로고
    • A simplified method to determine acetabular cup anteversion from plain radiographs
    • 15067657 10.1016/j.arth.2003.10.016
    • Widmer KH. A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty. 2004;19:387-390.
    • (2004) J Arthroplasty. , vol.19 , pp. 387-390
    • Widmer, K.H.1
  • 29
    • 0020356121 scopus 로고
    • Dislocations after total hip arthroplasty
    • 7142237 1:STN:280:DyaL3s%2FlslSgtQ%3D%3D
    • Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982;64:1295-1306.
    • (1982) J Bone Joint Surg Am. , vol.64 , pp. 1295-1306
    • Woo, R.Y.1    Morrey, B.F.2
  • 30
    • 34547824715 scopus 로고    scopus 로고
    • Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements
    • 17826270 10.1016/j.arth.2006.10.001
    • Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymüller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements. J Arthroplasty. 2007;22:812-817.
    • (2007) J Arthroplasty. , vol.22 , pp. 812-817
    • Ybinger, T.1    Kumpan, W.2    Hoffart, H.E.3    Muschalik, B.4    Bullmann, W.5    Zweymüller, K.6