메뉴 건너뛰기




Volumn 94 B, Issue 1, 2012, Pages 32-36

Reliability and validity of measuring version of the acetabular component

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ADULT; AGED; ARTICLE; BONE NECROSIS; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; INTERMETHOD COMPARISON; MALE; MEASUREMENT; OSTEOARTHRITIS; PRIORITY JOURNAL; RADIOGRAPHY; RADIOLOGICAL PROCEDURES; RELIABILITY; TOTAL HIP PROSTHESIS; VALIDITY;

EID: 84862925221     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.94B1.27621     Document Type: Article
Times cited : (99)

References (28)
  • 3
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg [Br] 1993;75-B:228-232. (Pubitemid 23087178)
    • (1993) Journal of Bone and Joint Surgery - Series B , vol.75 , Issue.2 , pp. 228-232
    • Murray, D.W.1
  • 4
    • 0015632760 scopus 로고
    • Prosthetic hip angulation
    • McLaren RH. Prosthetic hip angulation. Radiology 1973;107:705-706.
    • (1973) Radiology , vol.107 , pp. 705-706
    • McLaren, R.H.1
  • 5
    • 33749449658 scopus 로고    scopus 로고
    • A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs
    • Liaw CK, Hou SM, Yang RS, Wu TY, Fuh CS. A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs. Clin Orthop 2006;451:134-139.
    • (2006) Clin Orthop , vol.451 , pp. 134-139
    • Liaw, C.K.1    Hou, S.M.2    Yang, R.S.3    Wu, T.Y.4    Fuh, C.S.5
  • 6
    • 1942422237 scopus 로고    scopus 로고
    • A simplified method to determine acetabular cup anteversion from plain radiographs
    • Widmer KH. A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 2004;19:387-390.
    • (2004) J Arthroplasty , vol.19 , pp. 387-390
    • Widmer, K.H.1
  • 7
    • 0033050961 scopus 로고    scopus 로고
    • Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs
    • DOI 10.1302/0301-620X.81B3.9067
    • Pradhan R. Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg [Br] 1999;81-B:431-435. (Pubitemid 29245895)
    • (1999) Journal of Bone and Joint Surgery - Series B , vol.81 , Issue.3 , pp. 431-435
    • Pradhan, R.1
  • 10
    • 0019997368 scopus 로고
    • Radiologic evaluation of the position of the acetabular component of the total hip prosthesis
    • Pettersson H, Gentz CF, Lindberg HO, Carlsson AS. Radiologic evaluation of the position of the acetabular component of the total hip prosthesis. Acta Radiol Diagn (Stockh) 1982;23:259-263. (Pubitemid 12034102)
    • (1982) Acta Radiologica - Series Diagnosis , vol.23 , Issue.3 A , pp. 259-263
    • Pettersson, H.1    Gentz, C.F.2    Lindberg, H.O.3    Carlsson, A.S.4
  • 11
    • 0019409414 scopus 로고
    • A new method for measuring angles after total hip arthroplasty. A study of the acetabular cup and femoral component
    • Visser JD, Konings JG. A new method for measuring angles after total hip arthroplasty: a study of the acetabular cup and femoral component. J Bone Joint Surg [Br] 1981;63-B:556-559. (Pubitemid 11029173)
    • (1981) Journal of Bone and Joint Surgery - Series B , vol.63 , Issue.4 , pp. 556-559
    • Visser, J.D.1    Konings, J.G.2
  • 12
    • 69249214257 scopus 로고    scopus 로고
    • CT outperforms radiography for determination of acetabular cup version after THA
    • Ghelman B, Kepler CK, Lyman S, Della Valle AG. CT outperforms radiography for determination of acetabular cup version after THA. Clin Orthop 2009;467:2362-2370.
    • (2009) Clin Orthop , vol.467 , pp. 2362-2370
    • Ghelman, B.1    Kepler, C.K.2    Lyman, S.3    Della Valle, A.G.4
  • 14
    • 33746878867 scopus 로고    scopus 로고
    • Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography
    • DOI 10.1007/s00402-006-0163-0
    • Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G. Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg 2006;126:487-492. (Pubitemid 44194514)
    • (2006) Archives of Orthopaedic and Trauma Surgery , vol.126 , Issue.7 , pp. 487-492
    • Marx, A.1    Von, K.M.2    Pfortner, J.3    Wiese, M.4    Saxler, G.5
  • 15
    • 0037093925 scopus 로고    scopus 로고
    • Sample size requirements for estimating intraclass correlations with desired precision
    • DOI 10.1002/sim.1108
    • Bonett DG. Sample size requirements for estimating intraclass correlations with desired precision. Stat Med 2002;21:1331-1335. (Pubitemid 34467237)
    • (2002) Statistics in Medicine , vol.21 , Issue.9 , pp. 1331-1335
    • Bonett, D.G.1
  • 16
    • 34547584100 scopus 로고    scopus 로고
    • Difference Between 2 Measurement Methods of Version Angles of the Acetabular Component
    • DOI 10.1016/j.arth.2006.07.011, PII S0883540306005602
    • Arai N, Nakamura S, Matsushita T. Difference between 2 measurement methods of version angles of the acetabular component. J Arthroplasty 2007;22:715-720. (Pubitemid 47198429)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.5 , pp. 715-720
    • Arai, N.1    Nakamura, S.2    Matsushita, T.3
  • 17
    • 2942627493 scopus 로고    scopus 로고
    • Joint replacement-total hip replacement with CT-based navigation
    • Widmer KH, Grützner PA. Joint replacement-total hip replacement with CT-based navigation. Injury 2004;35(Suppl 1):84-89.
    • (2004) Injury , vol.35 , Issue.SUPPL. 1 , pp. 84-89
    • Widmer, K.H.1    Grützner, P.A.2
  • 19
    • 0026466430 scopus 로고
    • Does memory contaminate test-retest reliability?
    • McKelvie SJ. Does memory contaminate test-retest reliability? J Gen Psychol 1992;119:59-72.
    • (1992) J Gen Psychol , vol.119 , pp. 59-72
    • McKelvie, S.J.1
  • 21
    • 0014848821 scopus 로고
    • Total hip replacement by low-friction arthroplasty
    • Charnley J. Total hip replacement by low-friction arthroplasty. Clin Orthop 1970;72:7-21.
    • (1970) Clin Orthop , vol.72 , pp. 7-21
    • Charnley, J.1
  • 22
    • 0021968348 scopus 로고
    • Late dislocations in patients with Charnley total hip arthroplasty
    • Coventry MB. Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg [Am] 1985;67-A:832-841. (Pubitemid 15240305)
    • (1985) Journal of Bone and Joint Surgery - Series A , vol.67 , Issue.6 , pp. 832-841
    • Coventry, M.B.1
  • 23
    • 0018872376 scopus 로고
    • Advances in surgical technique for total hip replacement: Without and with osteotomy of the greater trochanter
    • Harris WH. Advances in surgical technique for total hip replacement: without and with osteotomy of the greater trochanter. Clin Orthop 1980;146:188-204. (Pubitemid 10139036)
    • (1980) Clinical Orthopaedics and Related Research , vol.146 , pp. 188-204
    • Harris, W.H.1
  • 24
    • 0032124945 scopus 로고    scopus 로고
    • Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation
    • DOI 10.1002/jor.1100160418
    • Seki M, Yuasa N, Ohkuni K. Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation. J Orthop Res 1998;16:513-517. (Pubitemid 28427704)
    • (1998) Journal of Orthopaedic Research , vol.16 , Issue.4 , pp. 513-517
    • Seki, M.1    Yuasa, N.2    Ohkuni, K.3
  • 25
    • 0018719005 scopus 로고
    • Three methods for determining anteversion and retroversion of a total hip prosthesis
    • Ghelman B. Three methods for determining anteversion and retroversion of a total hip prosthesis. AJR Am J Roentgenol 1979;133:1127-1134. (Pubitemid 10215282)
    • (1979) American Journal of Roentgenology , vol.133 , Issue.6 , pp. 1127-1134
    • Ghelman, B.1
  • 26
    • 0017622529 scopus 로고
    • Roentgenographic measurements after Muller total hip replacement. Correlations among roentgenographic measurements and hip strength and mobility
    • Gore DR, Murray MP, Gardner GM, Sepic SB. Roentgenographic measurements after Muller total hip replacement: correlations among roentgenographic measurements and hip strength and mobility. J Bone Joint Surg [Am] 1977;59-A:948-953. (Pubitemid 8218256)
    • (1977) Journal of Bone and Joint Surgery - Series A , vol.59 , Issue.7 , pp. 948-953
    • Gore, D.R.1    Murray, M.P.2    Gardner, G.M.3    Sepic, S.B.4
  • 27
    • 71249128337 scopus 로고    scopus 로고
    • Anterior dislocation of a total hip replacement: Radiographic and CT-scan assessment: behavior following conservative management
    • Di Schino M, Baudart F, Zilber S, Poignard A, Allain J. Anterior dislocation of a total hip replacement: radiographic and CT-scan assessment: behavior following conservative management. Orthop Traumatol Surg Res 2009;95:573-578.
    • (2009) Orthop Traumatol Surg Res , vol.95 , pp. 573-578
    • Di Schino, M.1    Baudart, F.2    Zilber, S.3    Poignard, A.4    Allain, J.5
  • 28
    • 62349119720 scopus 로고    scopus 로고
    • Measurement of the acetabular cup anteversion on simulated radiographs
    • Liaw CK, Yang RS, Hou SM, Wu TY, Fuh CS. Measurement of the acetabular cup anteversion on simulated radiographs. J Arthroplasty 2009;24:468-474.
    • (2009) J Arthroplasty , vol.24 , pp. 468-474
    • Liaw, C.K.1    Yang, R.S.2    Hou, S.M.3    Wu, T.Y.4    Fuh, C.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.