메뉴 건너뛰기




Volumn 25, Issue 5, 2010, Pages 812-819

A Validation Model for Measurement of Acetabular Component Position

Author keywords

Anteversion; CT scan; Inclination; Total hip; Validation

Indexed keywords

ACCURACY; ACETABULUM; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER SYSTEM; HIP RADIOGRAPHY; MEASUREMENT; MODEL; STANDARDIZATION; TOTAL HIP PROSTHESIS; VALIDATION PROCESS;

EID: 77954659964     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2009.04.021     Document Type: Article
Times cited : (45)

References (38)
  • 1
    • 0031690023 scopus 로고    scopus 로고
    • Computer assisted measurement of cup placement in total hip replacement
    • Jaramaz B., DiGioia A.M., Blackwell M., et al. Computer assisted measurement of cup placement in total hip replacement. Clin Orthop Relat Res 1998, 70.
    • (1998) Clin Orthop Relat Res , pp. 70
    • Jaramaz, B.1    DiGioia, A.M.2    Blackwell, M.3
  • 2
    • 0035205987 scopus 로고    scopus 로고
    • Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. Orthop Clin North Am.;32:569, vii.
    • Barrack RL, Lavernia C, Ries M, et al. Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty. Orthop Clin North Am. 2001;32:569, vii.
    • (2001)
    • Barrack RL1    Lavernia C2    Ries M3
  • 3
    • 33846452152 scopus 로고    scopus 로고
    • Computed tomographic evaluation of component position on dislocation after total hip arthroplasty
    • Komeno M., Hasegawa M., Sudo A., et al. Computed tomographic evaluation of component position on dislocation after total hip arthroplasty. Orthopedics 2006, 29:1104.
    • (2006) Orthopedics , vol.29 , pp. 1104
    • Komeno, M.1    Hasegawa, M.2    Sudo, A.3
  • 4
    • 0017859205 scopus 로고
    • Dislocations after total hip-replacement arthroplasties
    • Lewinnek G.E., Lewis J.L., Tarr R., et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 1978, 60:217.
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 217
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 5
    • 27244451801 scopus 로고    scopus 로고
    • Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching
    • Blendea S., Eckman K., Jaramaz B., et al. Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg 2005, 10:37.
    • (2005) Comput Aided Surg , vol.10 , pp. 37
    • Blendea, S.1    Eckman, K.2    Jaramaz, B.3
  • 6
    • 58249092132 scopus 로고    scopus 로고
    • Imaging and navigation measurement of acetabular component position in THA
    • Wan Z., Malik A., Jaramaz B., et al. Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res 2009, 467:32.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 32
    • Wan, Z.1    Malik, A.2    Jaramaz, B.3
  • 7
    • 0032178167 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment
    • DiGioia A.M., Jaramaz B., Blackwell M., et al. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res 1998, 8.
    • (1998) Clin Orthop Relat Res , pp. 8
    • DiGioia, A.M.1    Jaramaz, B.2    Blackwell, M.3
  • 8
    • 0036220260 scopus 로고    scopus 로고
    • Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis
    • Jolles B.M., Zangger P., Leyvraz P.F. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty 2002, 17:282.
    • (2002) J Arthroplasty , vol.17 , pp. 282
    • Jolles, B.M.1    Zangger, P.2    Leyvraz, P.F.3
  • 9
    • 37349018735 scopus 로고    scopus 로고
    • Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position
    • [Publish Ahead of Print]
    • Dorr L.D., Malik A., Wan Z., et al. Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res 2007, [Publish Ahead of Print].
    • (2007) Clin Orthop Relat Res
    • Dorr, L.D.1    Malik, A.2    Wan, Z.3
  • 10
    • 0026522003 scopus 로고
    • Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty
    • Mian S.W., Truchly G., Pflum F.A. Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty. Clin Orthop Relat Res 1992, 276:206.
    • (1992) Clin Orthop Relat Res , vol.276 , pp. 206
    • Mian, S.W.1    Truchly, G.2    Pflum, F.A.3
  • 12
    • 34248571570 scopus 로고    scopus 로고
    • Comparison of fluoroscopic and imageless registration in surgical navigation of the acetabular component
    • Stiehl J.B., Heck D.A., Jaramaz B., et al. Comparison of fluoroscopic and imageless registration in surgical navigation of the acetabular component. Comput Aided Surg 2007, 12:116.
    • (2007) Comput Aided Surg , vol.12 , pp. 116
    • Stiehl, J.B.1    Heck, D.A.2    Jaramaz, B.3
  • 13
    • 2342464910 scopus 로고    scopus 로고
    • Computed tomography-based navigation for hip, knee, and spine surgery
    • Amiot L.P., Poulin F. Computed tomography-based navigation for hip, knee, and spine surgery. Clin Orthop Relat Res 2004, 77.
    • (2004) Clin Orthop Relat Res , pp. 77
    • Amiot, L.P.1    Poulin, F.2
  • 14
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray D.W. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993, 75:228.
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 228
    • Murray, D.W.1
  • 15
    • 26044483910 scopus 로고    scopus 로고
    • Development of imageless computer navigation for acetabular component position in total hip replacement
    • Dorr L.D., Hishiki Y., Wan Z., et al. Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J 2005, 25:1.
    • (2005) Iowa Orthop J , vol.25 , pp. 1
    • Dorr, L.D.1    Hishiki, Y.2    Wan, Z.3
  • 16
    • 3042657286 scopus 로고    scopus 로고
    • A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients
    • Olivecrona H., Weidenhielm L., Olivecrona L., et al. A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients. Acta Orthop Scand 2004, 75:252.
    • (2004) Acta Orthop Scand , vol.75 , pp. 252
    • Olivecrona, H.1    Weidenhielm, L.2    Olivecrona, L.3
  • 17
    • 34250758507 scopus 로고    scopus 로고
    • Postoperative calculation of acetabular cup position using 2-D-3-D registration
    • Penney G.P., Edwards P.J., Hipwell J.H., et al. Postoperative calculation of acetabular cup position using 2-D-3-D registration. IEEE Trans Biomed Eng 2007, 54:1342.
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 1342
    • Penney, G.P.1    Edwards, P.J.2    Hipwell, J.H.3
  • 18
    • 33646385936 scopus 로고    scopus 로고
    • Computed tomography analysis of acetabular anteversion and abduction
    • Stem E.S., O'Connor M.I., Kransdorf M.J., et al. Computed tomography analysis of acetabular anteversion and abduction. Skeletal Radiol 2006, 35:385.
    • (2006) Skeletal Radiol , vol.35 , pp. 385
    • Stem, E.S.1    O'Connor, M.I.2    Kransdorf, M.J.3
  • 19
    • 33746318334 scopus 로고    scopus 로고
    • Computed tomography measurement of the accuracy of component version in total hip arthroplasty
    • Wines A.P., McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 2006, 21:696.
    • (2006) J Arthroplasty , vol.21 , pp. 696
    • Wines, A.P.1    McNicol, D.2
  • 20
    • 4344626911 scopus 로고    scopus 로고
    • The accuracy of free-hand cup positioning-a CT based measurement of cup placement in 105 total hip arthroplasties
    • Saxler G., Marx A., Vandevelde D., et al. The accuracy of free-hand cup positioning-a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop 2004, 28:198.
    • (2004) Int Orthop , vol.28 , pp. 198
    • Saxler, G.1    Marx, A.2    Vandevelde, D.3
  • 23
    • 33749431183 scopus 로고    scopus 로고
    • Functional pelvic orientation measured from lateral standing and sitting radiographs
    • DiGioia A.M., Hafez M.A., Jaramaz B., et al. Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res 2006, 453:272.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 272
    • DiGioia, A.M.1    Hafez, M.A.2    Jaramaz, B.3
  • 24
    • 0031894930 scopus 로고    scopus 로고
    • Accuracy of intraoperative assessment of acetabular prosthesis placement
    • Hassan D.M., Johnston G.H., Dust W.N., et al. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 1998, 13:80.
    • (1998) J Arthroplasty , vol.13 , pp. 80
    • Hassan, D.M.1    Johnston, G.H.2    Dust, W.N.3
  • 25
    • 24144477879 scopus 로고    scopus 로고
    • Pelvic tilt makes acetabular cup navigation inaccurate
    • Lembeck B., Mueller O., Reize P., et al. Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop 2005, 76:517.
    • (2005) Acta Orthop , vol.76 , pp. 517
    • Lembeck, B.1    Mueller, O.2    Reize, P.3
  • 26
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty. Causes and prevention
    • McCollum D.E., Gray W.J. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 1990, 159.
    • (1990) Clin Orthop Relat Res , pp. 159
    • McCollum, D.E.1    Gray, W.J.2
  • 27
    • 21844460572 scopus 로고    scopus 로고
    • Anatomic referencing of cup orientation in total hip arthroplasty
    • Tannast M., Langlotz U., Siebenrock K.A., et al. Anatomic referencing of cup orientation in total hip arthroplasty. Clin Orthop Relat Res 2005, 144.
    • (2005) Clin Orthop Relat Res , pp. 144
    • Tannast, M.1    Langlotz, U.2    Siebenrock, K.A.3
  • 28
    • 34249748966 scopus 로고    scopus 로고
    • Sagittal pelvic mal-rotation and positioning of the acetabular component in total hip arthroplasty: three-dimensional computer model analysis
    • Tang W.M., Chiu K.Y., Kwan M.F., et al. Sagittal pelvic mal-rotation and positioning of the acetabular component in total hip arthroplasty: three-dimensional computer model analysis. J Orthop Res 2007, 25:766.
    • (2007) J Orthop Res , vol.25 , pp. 766
    • Tang, W.M.1    Chiu, K.Y.2    Kwan, M.F.3
  • 29
    • 0028014646 scopus 로고
    • Causes of dislocation of total hip arthroplasty. CT study of component alignment
    • Pierchon F., Pasquier G., Cotten A., et al. Causes of dislocation of total hip arthroplasty. CT study of component alignment. J Bone Joint Surg Br 1994, 76:45.
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 45
    • Pierchon, F.1    Pasquier, G.2    Cotten, A.3
  • 30
    • 0031685471 scopus 로고    scopus 로고
    • Computer assisted orthopaedic surgery. Image guided and robotic assistive technologies
    • DiGioia A.M., Jaramaz B., Colgan B.D. Computer assisted orthopaedic surgery. Image guided and robotic assistive technologies. Clin Orthop Relat Res 1998, 8.
    • (1998) Clin Orthop Relat Res , pp. 8
    • DiGioia, A.M.1    Jaramaz, B.2    Colgan, B.D.3
  • 31
    • 38949157778 scopus 로고    scopus 로고
    • The rationale for tilt-adjusted acetabular cup navigation
    • Babisch J.W., Layher F., Amiot L.P. The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am 2008, 90:357.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 357
    • Babisch, J.W.1    Layher, F.2    Amiot, L.P.3
  • 32
    • 1242319991 scopus 로고    scopus 로고
    • Influence of component positions on dislocation: computed tomographic evaluations in a consecutive series of total hip arthroplasty
    • Nishii T., Sugano N., Miki H., et al. Influence of component positions on dislocation: computed tomographic evaluations in a consecutive series of total hip arthroplasty. J Arthroplasty 2004, 19:162.
    • (2004) J Arthroplasty , vol.19 , pp. 162
    • Nishii, T.1    Sugano, N.2    Miki, H.3
  • 33
    • 33846580604 scopus 로고    scopus 로고
    • Comparison of conventional versus computer-navigated acetabular component insertion
    • Haaker R.G., Tiedjen K., Ottersbach A., et al. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty 2007, 22:151.
    • (2007) J Arthroplasty , vol.22 , pp. 151
    • Haaker, R.G.1    Tiedjen, K.2    Ottersbach, A.3
  • 34
    • 33847106088 scopus 로고    scopus 로고
    • Implant position calculation for acetabular cup placement considering pelvic lateral tilt and inclination
    • Chen E., Goertz W., Lill C.A. Implant position calculation for acetabular cup placement considering pelvic lateral tilt and inclination. Comput Aided Surg 2006, 11:309.
    • (2006) Comput Aided Surg , vol.11 , pp. 309
    • Chen, E.1    Goertz, W.2    Lill, C.A.3
  • 35
    • 0019997368 scopus 로고
    • Radiologic evaluation of the position of the acetabular component of the total hip prosthesis
    • Pettersson H., Gentz C.F., Lindberg H.O., et al. Radiologic evaluation of the position of the acetabular component of the total hip prosthesis. Acta Radiol Diagn (Stockh) 1982, 23(3A):259.
    • (1982) Acta Radiol Diagn (Stockh) , vol.23 , Issue.3 A , pp. 259
    • Pettersson, H.1    Gentz, C.F.2    Lindberg, H.O.3
  • 36
    • 0029582771 scopus 로고
    • Can simple radiographs be predictive of total hip dislocation?
    • Pollard J.A., Daum W.J., Uchida T. Can simple radiographs be predictive of total hip dislocation?. J Arthroplasty 1995, 10:800.
    • (1995) J Arthroplasty , vol.10 , pp. 800
    • Pollard, J.A.1    Daum, W.J.2    Uchida, T.3
  • 37
    • 0016426550 scopus 로고
    • Total hip prosthesis: real and apparent dislocation
    • Jackson D.M. Total hip prosthesis: real and apparent dislocation. Clin Radiol 1975, 26:63.
    • (1975) Clin Radiol , vol.26 , pp. 63
    • Jackson, D.M.1
  • 38
    • 4444305327 scopus 로고    scopus 로고
    • Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement
    • Jolles B.M., Genoud P., Hoffmeyer P. Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement. Clin Orthop Relat Res 2004, 174.
    • (2004) Clin Orthop Relat Res , pp. 174
    • Jolles, B.M.1    Genoud, P.2    Hoffmeyer, P.3