메뉴 건너뛰기




Volumn 40, Issue 8, 2013, Pages

Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source

Author keywords

gold nanoparticles; preclinical imaging; x ray fluorescence

Indexed keywords

BLOOD VESSELS; CALIBRATION; ELECTRON SOURCES; FIBER OPTIC SENSORS; FLUORESCENCE IMAGING; GOLD NANOPARTICLES; IMAGE SEGMENTATION; METAL NANOPARTICLES; PHANTOMS; SEMICONDUCTOR DIODES; SHELLS (STRUCTURES); SILICON; SILICON COMPOUNDS; SPATIAL DISTRIBUTION; TUMORS; X RAY APPARATUS; X RAYS;

EID: 84881654970     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4816297     Document Type: Article
Times cited : (39)

References (27)
  • 1
    • 36949082360 scopus 로고
    • Estimation of strontium in animal bone using x-ray fluorescence analysis
    • 10.1038/183887a0
    • W. M. Roberts, " Estimation of strontium in animal bone using x-ray fluorescence analysis.," Nature (London) 183, 887-888 (1959). 10.1038/183887a0
    • (1959) Nature (London) , vol.183 , pp. 887-888
    • Roberts, W.M.1
  • 2
    • 4243380471 scopus 로고
    • An x-ray fluorescence method for the determination of calcium, potassium, chlorine, sulfur, and phosphorus in biological tissues
    • 10.1021/ac60232a010
    • G. V. Alexander, " An x-ray fluorescence method for the determination of calcium, potassium, chlorine, sulfur, and phosphorus in biological tissues.," Anal. Chem. 37, 1671-1674 (1965). 10.1021/ac60232a010
    • (1965) Anal. Chem. , vol.37 , pp. 1671-1674
    • Alexander, G.V.1
  • 3
    • 37049248839 scopus 로고
    • X-ray fluorescence analysis in biology
    • 10.1126/science.134.3477.449
    • T. Hall, " X-ray fluorescence analysis in biology.," Science 134, 449-455 (1961). 10.1126/science.134.3477.449
    • (1961) Science , vol.134 , pp. 449-455
    • Hall, T.1
  • 4
    • 79551692320 scopus 로고    scopus 로고
    • In vivo quantification of lead in bone with a portable x-ray fluorescence system - Methodology and feasibility
    • 10.1088/0031-9155/56/3/N01
    • L. H. Nie, S. Sanchez, K. Newton, L. Grodzins, R. O. Cleveland, and M. G. Weisskopf, " In vivo quantification of lead in bone with a portable x-ray fluorescence system-Methodology and feasibility.," Phys. Med. Biol. 56, N39-N51 (2011). 10.1088/0031-9155/56/3/N01
    • (2011) Phys. Med. Biol. , vol.56
    • Nie, L.H.1    Sanchez, S.2    Newton, K.3    Grodzins, L.4    Cleveland, R.O.5    Weisskopf, M.G.6
  • 5
    • 84871877424 scopus 로고    scopus 로고
    • Use of portable x-ray fluorescence (PXRF) in vivo as an alternative technique for the assessment of iron levels in patients with thalassemia and hemochromatosis
    • 10.1097/HP.0b013e3182667721
    • M. Estevam and C. R. Appoloni, " Use of portable x-ray fluorescence (PXRF) in vivo as an alternative technique for the assessment of iron levels in patients with thalassemia and hemochromatosis.," Health Phys. 104, 132-138 (2013). 10.1097/HP.0b013e3182667721
    • (2013) Health Phys. , vol.104 , pp. 132-138
    • Estevam, M.1    Appoloni, C.R.2
  • 8
    • 0024656194 scopus 로고
    • A new tomographic device based on the detection of fluorescent x-rays
    • 10.1016/0168-9002(89)90802-4
    • R. Cesareo and S. Mascarenhas, " A new tomographic device based on the detection of fluorescent x-rays.," Nucl. Instrum. Methods Phys. Res. A 277, 669-672 (1989). 10.1016/0168-9002(89)90802-4
    • (1989) Nucl. Instrum. Methods Phys. Res. A , vol.277 , pp. 669-672
    • Cesareo, R.1    Mascarenhas, S.2
  • 9
    • 0026370093 scopus 로고
    • Fluorescent computer tomography: A model for correction of x-ray absorption
    • 10.1109/23.124168
    • J. P. Hogan, R. A. Gonsalves, and A. S. Krieger, " Fluorescent computer tomography: A model for correction of x-ray absorption.," IEEE Trans. Nucl. Sci. 38, 1721-1727 (1991). 10.1109/23.124168
    • (1991) IEEE Trans. Nucl. Sci. , vol.38 , pp. 1721-1727
    • Hogan, J.P.1    Gonsalves, R.A.2    Krieger, A.S.3
  • 12
    • 0035903383 scopus 로고    scopus 로고
    • Reconstructing x-ray fluorescence microtomograms
    • 10.1063/1.1402643
    • C. Schroer, " Reconstructing x-ray fluorescence microtomograms., " Appl. Phys. Lett. 79, 1912-1914 (2001). 10.1063/1.1402643
    • (2001) Appl. Phys. Lett. , vol.79 , pp. 1912-1914
    • Schroer, C.1
  • 13
    • 3042821075 scopus 로고    scopus 로고
    • Approximate analytic reconstruction in x-ray fluorescence computed tomography
    • 10.1088/0031-9155/49/11/019
    • P. J. La Rivière, " Approximate analytic reconstruction in x-ray fluorescence computed tomography.," Phys. Med. Biol. 49, 2391-2405 (2004). 10.1088/0031-9155/49/11/019
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2391-2405
    • La Rivière, P.J.1
  • 14
    • 76149141618 scopus 로고    scopus 로고
    • X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays
    • 10.1088/0031-9155/55/3/007
    • S. K. Cheong, B. L. Jones, A. K. Siddiqi, F. Liu, N. Manohar, and S. H. Cho, " X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays.," Phys. Med. Biol. 55, 647-662 (2010). 10.1088/0031-9155/55/3/007
    • (2010) Phys. Med. Biol. , vol.55 , pp. 647-662
    • Cheong, S.K.1    Jones, B.L.2    Siddiqi, A.K.3    Liu, F.4    Manohar, N.5    Cho, S.H.6
  • 15
    • 79958116321 scopus 로고    scopus 로고
    • The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: A Monte Carlo study
    • 10.1088/0031-9155/56/12/017
    • B. L. Jones and S. H. Cho, " The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: A Monte Carlo study.," Phys. Med. Biol. 56, 3719-3730 (2011). 10.1088/0031-9155/56/12/017
    • (2011) Phys. Med. Biol. , vol.56 , pp. 3719-3730
    • Jones, B.L.1    Cho, S.H.2
  • 16
    • 84870348240 scopus 로고    scopus 로고
    • Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams
    • 10.1088/0031-9155/57/23/N457
    • B. L. Jones, N. Manohar, F. Reynoso, A. Karellas, and S. H. Cho, " Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams.," Phys. Med. Biol. 57, N457-N467 (2012). 10.1088/0031-9155/57/23/N457
    • (2012) Phys. Med. Biol. , vol.57
    • Jones, B.L.1    Manohar, N.2    Reynoso, F.3    Karellas, A.4    Cho, S.H.5
  • 17
    • 84864625038 scopus 로고    scopus 로고
    • Investigation of x-ray fluorescence computed tomography (XFCT) and K-edge imaging
    • 10.1109/TMI.2012.2201165
    • M. Bazalova, Y. Kuang, G. Pratx, and L. Xing, " Investigation of x-ray fluorescence computed tomography (XFCT) and K-edge imaging.," IEEE Trans. Med. Imaging 31, 1620-1627 (2012). 10.1109/TMI.2012.2201165
    • (2012) IEEE Trans. Med. Imaging , vol.31 , pp. 1620-1627
    • Bazalova, M.1    Kuang, Y.2    Pratx, G.3    Xing, L.4
  • 18
    • 84873290399 scopus 로고    scopus 로고
    • First demonstration of multiplexed x-ray fluorescence computed tomography (XFCT) imaging
    • 10.1109/TMI.2012.2223709
    • Y. Kuang, G. Pratx, M. Bazalova, B. Meng, J. Qian, and L. Xing, " First demonstration of multiplexed x-ray fluorescence computed tomography (XFCT) imaging.," IEEE Trans. Med. Imaging 32, 262-267 (2013). 10.1109/TMI.2012.2223709
    • (2013) IEEE Trans. Med. Imaging , vol.32 , pp. 262-267
    • Kuang, Y.1    Pratx, G.2    Bazalova, M.3    Meng, B.4    Qian, J.5    Xing, L.6
  • 19
    • 84874776039 scopus 로고    scopus 로고
    • Development of XFCT imaging strategy for monitoring the spatial distribution of platinum-based chemodrugs: Instrumentation and phantom validation
    • (7p). 10.1118/1.4789917
    • Y. Kuang, G. Pratx, M. Bazalova, J. Qian, B. Meng, and L. Xing, " Development of XFCT imaging strategy for monitoring the spatial distribution of platinum-based chemodrugs: Instrumentation and phantom validation.," Med. Phys. 40, 030701 (7pp.) (2013). 10.1118/1.4789917
    • (2013) Med. Phys. , vol.40 , pp. 030701
    • Kuang, Y.1    Pratx, G.2    Bazalova, M.3    Qian, J.4    Meng, B.5    Xing, L.6
  • 20
    • 84872114476 scopus 로고    scopus 로고
    • A quantitative x-ray detection system for gold nanoparticle tumour biomarkers
    • 10.1088/0031-9155/57/17/5543
    • K. Ricketts, A. Castoldi, C. Guazzoni, C. Ozkan, C. Christodoulou, A. P. Gibson, and G. J. Royle, " A quantitative x-ray detection system for gold nanoparticle tumour biomarkers.," Phys. Med. Biol. 57, 5543-5555 (2012). 10.1088/0031-9155/57/17/5543
    • (2012) Phys. Med. Biol. , vol.57 , pp. 5543-5555
    • Ricketts, K.1    Castoldi, A.2    Guazzoni, C.3    Ozkan, C.4    Christodoulou, C.5    Gibson, A.P.6    Royle, G.J.7
  • 21
    • 84881635050 scopus 로고    scopus 로고
    • Feasibility of direct L-shell fluorescence imaging of gold nanoparticles using a benchtop x-ray source
    • 10.1118/1.4736269
    • N. Manohar, F. Reynoso, and S. H. Cho, " Feasibility of direct L-shell fluorescence imaging of gold nanoparticles using a benchtop x-ray source.," Med. Phys. 39, 3987-3988 (2012). 10.1118/1.4736269
    • (2012) Med. Phys. , vol.39 , pp. 3987-3988
    • Manohar, N.1    Reynoso, F.2    Cho, S.H.3
  • 22
    • 84877252331 scopus 로고    scopus 로고
    • A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications
    • (10p). 10.1118/1.4798966
    • D. Wu, Y. Li, M. D. Wong, and H. Liu, " A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications.," Med. Phys. 40, 051901 (10pp.) (2013). 10.1118/1.4798966
    • (2013) Med. Phys. , vol.40 , pp. 051901
    • Wu, D.1    Li, Y.2    Wong, M.D.3    Liu, H.4
  • 23
    • 4644321604 scopus 로고    scopus 로고
    • The use of gold nanoparticles to enhance radiotherapy in mice
    • 10.1088/0031-9155/49/18/N03
    • J. F. Hainfeld, D. N. Slatkin, and H. M. Smilowitz, " The use of gold nanoparticles to enhance radiotherapy in mice.," Phys. Med. Biol. 49, N309-N315 (2004). 10.1088/0031-9155/49/18/N03
    • (2004) Phys. Med. Biol. , vol.49
    • Hainfeld, J.F.1    Slatkin, D.N.2    Smilowitz, H.M.3
  • 25
    • 0035739868 scopus 로고    scopus 로고
    • Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere
    • 10.1088/0031-9155/46/12/303
    • P. M. Fong, D. C. Keil, M. D. Does, and J. C. Gore, " Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere.," Phys. Med. Biol. 46, 3105-3113 (2001). 10.1088/0031-9155/46/ 12/303
    • (2001) Phys. Med. Biol. , vol.46 , pp. 3105-3113
    • Fong, P.M.1    Keil, D.C.2    Does, M.D.3    Gore, J.C.4
  • 26
    • 0001755354 scopus 로고
    • Scattered x-rays as internal standards in x-ray emission spectroscopy
    • 10.1021/ac60140a001
    • G. Andermann and J. W. Kemp, " Scattered x-rays as internal standards in x-ray emission spectroscopy.," Anal. Chem. 30, 1306-1309 (1958). 10.1021/ac60140a001
    • (1958) Anal. Chem. , vol.30 , pp. 1306-1309
    • Andermann, G.1    Kemp, J.W.2
  • 27
    • 0024874707 scopus 로고
    • Use of Compton scattering in quantitative XRF analysis of stained glass
    • 10.1016/0883-2889(89)90200-1
    • C. Bui, L. Confalonieri, and M. Milazzo, " Use of Compton scattering in quantitative XRF analysis of stained glass.," Int. J. Rad Appl. Instrum. A 40, 375-380 (1989). 10.1016/0883-2889(89)90200-1
    • (1989) Int. J. Rad Appl. Instrum , vol.40 , pp. 375-380
    • Bui, C.1    Confalonieri, L.2    Milazzo, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.