메뉴 건너뛰기




Volumn 31, Issue 8, 2012, Pages 1620-1627

Investigation of X-ray fluorescence computed tomography (XFCT) and K-edge imaging

Author keywords

Computed tomography; medical diagnostic imaging; molecular imaging

Indexed keywords

CIS-PLATIN; COMPUTED TOMOGRAPHY; CONTRAST TO NOISE RATIO; ENERGY RESOLUTIONS; ENERGY-RESOLVING DETECTORS; GOLD NANOPARTICLES; IMAGING COMPONENTS; K-EDGE IMAGING; MEDICAL DIAGNOSTICS; MONTE CARLO STUDY; X-RAY FLUORESCENCE COMPUTED TOMOGRAPHY;

EID: 84864625038     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2012.2201165     Document Type: Article
Times cited : (88)

References (24)
  • 1
    • 80455176514 scopus 로고    scopus 로고
    • Spectrally resolving and scattering-compensated X-ray luminescence/fluorescence computed tomography
    • Jun.
    • W. Cong, H. Shen, and G. Wang, "Spectrally resolving and scattering-compensated X-ray luminescence/fluorescence computed tomography," J. Biomed. Opt., vol. 16, no. 6, pp. 066014-1-066014-7, Jun. 2011.
    • (2011) J. Biomed. Opt. , vol.16 , Issue.6 , pp. 066014-066011
    • Cong, W.1    Shen, H.2    Wang, G.3
  • 2
    • 78549264818 scopus 로고    scopus 로고
    • Tomographic molecular imaging of X-ray-excitable nanoparticles
    • Oct.
    • G. Pratx et al., "Tomographic molecular imaging of X-ray-excitable nanoparticles," Opt. Lett., vol. 35, no. 20, pp. 3345-3347, Oct. 2010.
    • (2010) Opt. Lett. , vol.35 , Issue.20 , pp. 3345-3347
    • Pratx, G.1
  • 3
    • 78649671994 scopus 로고    scopus 로고
    • X-ray luminescence computed tomography via selective excitation: A feasibility study
    • Dec
    • G. Pratx et al., "X-ray luminescence computed tomography via selective excitation: A feasibility study," IEEE Trans. Med. Imag., vol. 29, no. 12, pp. 1992-1999, Dec. 2010.
    • (2010) IEEE Trans. Med. Imag. , vol.29 , Issue.12 , pp. 1992-1999
    • Pratx, G.1
  • 4
    • 79958116321 scopus 로고    scopus 로고
    • The feasibility of polychromatic conebeam X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: A Monte Carlo study
    • Jun.
    • B. L. Jones and S. H. Cho, "The feasibility of polychromatic conebeam X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: A Monte Carlo study," Phys. Med. Biol., vol. 56, no. 12, pp. 3719-3730, Jun. 2011.
    • (2011) Phys. Med. Biol. , vol.56 , Issue.12 , pp. 3719-3730
    • Jones, B.L.1    Cho, S.H.2
  • 5
    • 76149141618 scopus 로고    scopus 로고
    • X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp X-rays
    • Feb.
    • S.-K. Cheong et al., "X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp X-rays," Phys. Med. Biol., vol. 55, no. 3, pp. 647-662, Feb. 2010.
    • (2010) Phys. Med. Biol. , vol.55 , Issue.3 , pp. 647-662
    • Cheong, S.-K.1
  • 6
    • 57849124614 scopus 로고    scopus 로고
    • X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice
    • Jan
    • T. Takeda et al., "X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice," J. Synchrotron Radiat., vol. 16, pp. 57-62, Jan. 2009.
    • (2009) J. Synchrotron Radiat. , vol.16 , pp. 57-62
    • Takeda, T.1
  • 7
    • 0024656194 scopus 로고
    • A new tomographic device based on the detection of fluorescent X-rays
    • May
    • R. Cesareo and S. Mascarenhas, "A new tomographic device based on the detection of fluorescent X-rays," Nucl. Instrum. Methods Phys. Res., vol. 277, no. 2-3, pp. 669-672, May 1989.
    • (1989) Nucl. Instrum. Methods Phys. Res. , vol.277 , Issue.2-3 , pp. 669-672
    • Cesareo, R.1    Mascarenhas, S.2
  • 8
    • 37249089714 scopus 로고    scopus 로고
    • Gold nanoparticles: Interesting optical properties and recent applications in cancer diagnostics and therapy
    • DOI 10.2217/17435889.2.5.681
    • X. Huang et al., "Gold nanoparticles: Interesting optical properties and recent applications in cancer diagnostic and therapy," Nanomedicine, vol. 2, no. 5, pp. 681-693, Oct. 2007. (Pubitemid 350268247)
    • (2007) Nanomedicine , vol.2 , Issue.5 , pp. 681-693
    • Huang, X.1    Jain, P.K.2    El-Sayed, I.H.3    El-Sayed, M.A.4
  • 9
    • 2142694056 scopus 로고    scopus 로고
    • Cisplatin and platinum drugs at the molecular level (review)
    • Nov.-Dec
    • T. Boulikas and M. Vougiouka, "Cisplatin and platinum drugs at the molecular level (review)," Oncol. Rep., vol. 10, no. 6, pp. 1663-1682, Nov.-Dec. 2003.
    • (2003) Oncol. Rep. , vol.10 , Issue.6 , pp. 1663-1682
    • Boulikas, T.1    Vougiouka, M.2
  • 11
    • 63849101176 scopus 로고    scopus 로고
    • Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
    • Apr
    • A. N. Primak et al., "Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration," Med. Phys., vol. 36, no. 4, pp. 1359-1369, Apr. 2009.
    • (2009) Med. Phys. , vol.36 , Issue.4 , pp. 1359-1369
    • Primak, A.N.1
  • 12
    • 48349103232 scopus 로고    scopus 로고
    • Experimental feasibility of multi-energy photoncounting K-edge imaging in pre-clinical computed tomography
    • Aug
    • J. P. Schlomka et al., "Experimental feasibility of multi-energy photoncounting K-edge imaging in pre-clinical computed tomography," Phys. Med. Biol., vol. 53, no. 15, pp. 4031-4047, Aug. 2008.
    • (2008) Phys. Med. Biol. , vol.53 , Issue.15 , pp. 4031-4047
    • Schlomka, J.P.1
  • 16
    • 34748905444 scopus 로고    scopus 로고
    • Monte Carlo simulation of a computed tomography x-ray tube
    • DOI 10.1088/0031-9155/52/19/015, PII S0031915507545173, 015
    • M. Bazalova and F. Verhaegen, "Monte Carlo simulation of a computed tomography X-ray tube," Phys. Med. Biol., vol. 52, no. 19, pp. 5945-5955, Oct. 2007. (Pubitemid 47485424)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.19 , pp. 5945-5955
    • Bazalova, M.1    Verhaegen, F.2
  • 17
    • 0020753453 scopus 로고
    • Computed-tomography using synchrotron radiation
    • A. C. Thompson et al., "Computed-tomography using synchrotron radiation," Nucl. Instrum. Methods Phys. Res., vol. 222, no. 1-2, pp. 319-323, 1984.
    • (1984) Nucl. Instrum. Methods Phys. Res. , vol.222 , Issue.1-2 , pp. 319-323
    • Thompson, A.C.1
  • 20
    • 0025846955 scopus 로고
    • Uptake and retention of platinum in patients undergoing Cisplatin therapy
    • R. Jonson et al., "Uptake and retention of platinum in patients undergoing Cisplatin therapy," Acta Oncologica, vol. 30, no. 3, pp. 315-319, 1991.
    • (1991) Acta Oncologica , vol.30 , Issue.3 , pp. 315-319
    • Jonson, R.1
  • 21
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, "Maximum likelihood reconstruction for emission tomography," IEEE Trans. Med. Imag., vol. 1, no. 2, pp. 113-122, Oct. 1982. (Pubitemid 13557763)
    • (1982) IEEE Transactions on Medical Imaging , vol.MI-1 , Issue.2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 22
    • 3342890652 scopus 로고    scopus 로고
    • Performance of a low noise front-end ASIC for Si/CdTe detectors in compton gamma-ray telescope
    • Jun
    • H. Tajima et al., "Performance of a low noise front-end ASIC for Si/CdTe detectors in compton gamma-ray telescope," IEEE Trans. Nucl. Sci., vol. 51, no. 3, pp. 842-847, Jun. 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.3 , pp. 842-847
    • Tajima, H.1
  • 23
    • 4644321604 scopus 로고    scopus 로고
    • The use of gold nanoparticles to enhance radiotherapy in mice
    • DOI 10.1088/0031-9155/49/18/N03, PII S0031915504816269
    • J. F. Hainfeld, D. N. Slatkin, and H. M. Smilowitz, "The use of gold nanoparticles to enhance radiotherapy in mice," Phys. Med. Biol., vol. 49, no. 18, pp. N309-N315, 2004. (Pubitemid 39302700)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.18
    • Hainfeld, J.F.1    Slatkin, D.N.2    Smilowitz, H.M.3
  • 24
    • 0031996743 scopus 로고    scopus 로고
    • X-ray fluorescent computer tomography with synchrotron radiation
    • PII S0018949998012155
    • G. F. Rust and J. Weigelt, "X-ray fluorescent computer tomography with synchrotron radiation," IEEE Trans. Nucl. Sci., vol. 45, no. 1, pp. 75-88, Feb. 1998. (Pubitemid 128744655)
    • (1998) IEEE Transactions on Nuclear Science , vol.45 , Issue.1 , pp. 75-88
    • Rust, G.-F.1    Weigelt, J.2