메뉴 건너뛰기




Volumn 143, Issue 1, 2009, Pages 444-448

Development of indirect-competitive quartz crystal microbalance immunosensor for C-reactive protein

Author keywords

C reactive protein; Indirect competitive immunosensor; Quartz crystal microbalance; Specificity and sensitivity

Indexed keywords

C-REACTIVE PROTEIN; C-REACTIVE PROTEINS; COMPETITION REACTIONS; CONCENTRATION RANGES; FLOW-THROUGH CELLS; FREQUENCY RESPONSE ANALYZERS; HIGHLY SENSITIVE; INDIRECT-COMPETITIVE IMMUNOSENSOR; LIMIT OF DETECTION; LINEAR RELATIONSHIPS; LOGARITHMIC SCALE; MICRO-DISPENSING; OPTIMUM CONCENTRATION; OSCILLATOR MODULE; REACTION BUFFER; SENSOR CHIPS; SENSOR RESPONSE; SENSOR SYSTEMS; SODIUM PHOSPHATE BUFFER;

EID: 71849110876     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.09.046     Document Type: Article
Times cited : (67)

References (35)
  • 1
    • 71849097774 scopus 로고    scopus 로고
    • Scripps Laboratories, http://www.scrippslabs.com/datatables/protein_absorbance.html, 2007.
    • (2007) Scripps Laboratories
  • 2
    • 0030668555 scopus 로고    scopus 로고
    • Interleukin-6-dependent and -independent regulation of the human C-reactive protein gene
    • Weinhold B., and Rüther U. Interleukin-6-dependent and -independent regulation of the human C-reactive protein gene. Biochem. J. 327 (1997) 425-429
    • (1997) Biochem. J. , vol.327 , pp. 425-429
    • Weinhold, B.1    Rüther, U.2
  • 3
    • 0033545342 scopus 로고    scopus 로고
    • Acute-phase proteins and other systemic responses to inflammation
    • Gabay C., and Kushner I.N. Acute-phase proteins and other systemic responses to inflammation. New Engl. J. Med. 340 (1999) 448-454
    • (1999) New Engl. J. Med. , vol.340 , pp. 448-454
    • Gabay, C.1    Kushner, I.N.2
  • 4
    • 1642287457 scopus 로고    scopus 로고
    • Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks
    • Wolf M., Juncker D., Michel B., Hunziker P., and Emmanuel D. Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks. Biosens. Bioelectron. 19 (2004) 1193-1202
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1193-1202
    • Wolf, M.1    Juncker, D.2    Michel, B.3    Hunziker, P.4    Emmanuel, D.5
  • 5
    • 0035103498 scopus 로고    scopus 로고
    • High-sensitivity C-reactive protein: a novel and promising marker of coronary heart disease
    • Rifai N., and Ridker P.M. High-sensitivity C-reactive protein: a novel and promising marker of coronary heart disease. Clin. Chem. 47 (2001) 403-411
    • (2001) Clin. Chem. , vol.47 , pp. 403-411
    • Rifai, N.1    Ridker, P.M.2
  • 6
    • 31044439705 scopus 로고    scopus 로고
    • Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing
    • Hu W.P., Hsu H.-Y., Chiou A., Tseng K.Y., Lin H.-Y., Chang G.L., and Chen S.-J. Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing. Biosens. Bioelectron. 21 (2006) 1631-1637
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1631-1637
    • Hu, W.P.1    Hsu, H.-Y.2    Chiou, A.3    Tseng, K.Y.4    Lin, H.-Y.5    Chang, G.L.6    Chen, S.-J.7
  • 7
    • 0142095224 scopus 로고    scopus 로고
    • C-reactive protein and atherothrombosis-beyond a biomarker: an actual partaker of lesion formation
    • Verma S., and Yeh E.T. C-reactive protein and atherothrombosis-beyond a biomarker: an actual partaker of lesion formation. Am. J. Physiol. 285 (2003) R1253-R1256
    • (2003) Am. J. Physiol. , vol.285
    • Verma, S.1    Yeh, E.T.2
  • 8
    • 13444282300 scopus 로고    scopus 로고
    • Use of a time-resolved immunofluorometric assay for determination of canine C-reactive protein concentrations in whole blood
    • Parra M.D., Tuomola M., Cabezas-Herrera J., and Ceron J.J. Use of a time-resolved immunofluorometric assay for determination of canine C-reactive protein concentrations in whole blood. Am. J. Vet. Res. 1 (2005) 62-66
    • (2005) Am. J. Vet. Res. , vol.1 , pp. 62-66
    • Parra, M.D.1    Tuomola, M.2    Cabezas-Herrera, J.3    Ceron, J.J.4
  • 9
    • 4644332790 scopus 로고    scopus 로고
    • Measurement of C-reactive protein: two high sensitivity methods compared
    • Dominichi R., Luraschi P., and Franzini C. Measurement of C-reactive protein: two high sensitivity methods compared. J. Clin. Lab. Anal. 18 (2004) 280-284
    • (2004) J. Clin. Lab. Anal. , vol.18 , pp. 280-284
    • Dominichi, R.1    Luraschi, P.2    Franzini, C.3
  • 11
    • 33748582306 scopus 로고    scopus 로고
    • Development of a chemiluminescent immunosensor for chloramphenicol
    • Park I.-S., and Kim N. Development of a chemiluminescent immunosensor for chloramphenicol. Anal. Chim. Acta 578 (2006) 19-24
    • (2006) Anal. Chim. Acta , vol.578 , pp. 19-24
    • Park, I.-S.1    Kim, N.2
  • 12
    • 71849099365 scopus 로고    scopus 로고
    • Nanomechanical resonators and their potential to biosensor applications
    • Lee S., and Yoon D.S. Nanomechanical resonators and their potential to biosensor applications. BioChip J. 1 (2007) 193-199
    • (2007) BioChip J. , vol.1 , pp. 193-199
    • Lee, S.1    Yoon, D.S.2
  • 13
    • 8844221262 scopus 로고    scopus 로고
    • Evaluation of a high-affinity QCM immunosensor using antibody fragmentation and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer
    • Kurosawa S., Nakamura M., Park J.W., Aizawa H., Yamada K., and Hirata M. Evaluation of a high-affinity QCM immunosensor using antibody fragmentation and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer. Biosens. Bioelectron. 20 (2004) 1134-1139
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 1134-1139
    • Kurosawa, S.1    Nakamura, M.2    Park, J.W.3    Aizawa, H.4    Yamada, K.5    Hirata, M.6
  • 14
    • 44849102469 scopus 로고    scopus 로고
    • A high sensitivity assay for the inflammatory marker C-reactive protein employing acoustic biosensing
    • McBride J.D., and Cooper M.A. A high sensitivity assay for the inflammatory marker C-reactive protein employing acoustic biosensing. J. Nanobiotechnol. 6 (2008) 5
    • (2008) J. Nanobiotechnol. , vol.6 , pp. 5
    • McBride, J.D.1    Cooper, M.A.2
  • 15
    • 21644444010 scopus 로고    scopus 로고
    • Real-time QCM-D immunoassay through oriented antibody immobilization using cross-linked hydrogel biointerfaces
    • Carrigan S.D., Scott G., and Tabrizian M. Real-time QCM-D immunoassay through oriented antibody immobilization using cross-linked hydrogel biointerfaces. Langmuir 21 (2005) 5966-5973
    • (2005) Langmuir , vol.21 , pp. 5966-5973
    • Carrigan, S.D.1    Scott, G.2    Tabrizian, M.3
  • 16
    • 0036267307 scopus 로고    scopus 로고
    • Determination of alpha-fetoprotein in human serum by a quartz crystal microbalance-based immunosensor
    • Chou S.F., Hsu W.L., Hwang J.M., and Chen C.Y. Determination of alpha-fetoprotein in human serum by a quartz crystal microbalance-based immunosensor. Clin. Chem. 48 (2002) 913-918
    • (2002) Clin. Chem. , vol.48 , pp. 913-918
    • Chou, S.F.1    Hsu, W.L.2    Hwang, J.M.3    Chen, C.Y.4
  • 17
    • 29144455409 scopus 로고    scopus 로고
    • Site-directed immobilization of antibody fragments for detection of C-reactive protein
    • Vikholm-Lundin I., and Albers W.M. Site-directed immobilization of antibody fragments for detection of C-reactive protein. Biosens. Bioelectron. 21 (2006) 1141-1148
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1141-1148
    • Vikholm-Lundin, I.1    Albers, W.M.2
  • 18
    • 33645222733 scopus 로고    scopus 로고
    • SPR-based immunosensor for the CRP detection-a new method to detect a well known protein
    • Meyer M.H.F., Hartmann M., and Keusgen M. SPR-based immunosensor for the CRP detection-a new method to detect a well known protein. Biosens. Bioelectron. 21 (2006) 1987-1990
    • (2006) Biosens. Bioelectron. , vol.21 , pp. 1987-1990
    • Meyer, M.H.F.1    Hartmann, M.2    Keusgen, M.3
  • 19
    • 4143097105 scopus 로고    scopus 로고
    • Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein
    • Lee J.H., Yoon K.H., Hwang K.S., Park J., Ahn S., and Kim T.S. Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein. Biosens. Bioelectron. 20 (2004) 269-275
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 269-275
    • Lee, J.H.1    Yoon, K.H.2    Hwang, K.S.3    Park, J.4    Ahn, S.5    Kim, T.S.6
  • 20
    • 14644415474 scopus 로고    scopus 로고
    • Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers
    • Wee K.W., Kang G.Y., Park J., Kang J.Y., Yoon D.S., Park J.H., and Kim T.S. Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers. Biosens. Bioelectron. 20 (2005) 1932-1938
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 1932-1938
    • Wee, K.W.1    Kang, G.Y.2    Park, J.3    Kang, J.Y.4    Yoon, D.S.5    Park, J.H.6    Kim, T.S.7
  • 21
    • 41449091313 scopus 로고    scopus 로고
    • Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film
    • Chen X., Wang Y., Zhou J., Yan W., Li X., and Zhu J.J. Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film. Anal. Chem. 80 (2008) 2133-2140
    • (2008) Anal. Chem. , vol.80 , pp. 2133-2140
    • Chen, X.1    Wang, Y.2    Zhou, J.3    Yan, W.4    Li, X.5    Zhu, J.J.6
  • 23
    • 0036883709 scopus 로고    scopus 로고
    • Highly sensitive detection of cocaine using piezoelectric immunosensor
    • Halámek J., Makower A., Skládal P., and Scheller F.W. Highly sensitive detection of cocaine using piezoelectric immunosensor. Biosens. Bioelectron. 17 (2002) 1045-1050
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 1045-1050
    • Halámek, J.1    Makower, A.2    Skládal, P.3    Scheller, F.W.4
  • 24
    • 33845389633 scopus 로고    scopus 로고
    • Development of immunosensor based on OWLS technique for determining Aflatoxin B1 and Ochratoxin A
    • Adányi N., Levkovets I.A., Rodriguez-Gil S., Ronald A., Váradi M., and Szendro{combining double acute accent} I. Development of immunosensor based on OWLS technique for determining Aflatoxin B1 and Ochratoxin A. Biosens. Bioelectron. 22 (2007) 797-802
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 797-802
    • Adányi, N.1    Levkovets, I.A.2    Rodriguez-Gil, S.3    Ronald, A.4    Váradi, M.5    Szendro, I.6
  • 25
    • 0032213121 scopus 로고    scopus 로고
    • Thiolated Salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystal
    • Park I.-S., and Kim N. Thiolated Salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystal. Biosens. Bioelectron. 13 (1998) 1091-1097
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 1091-1097
    • Park, I.-S.1    Kim, N.2
  • 26
    • 2342598360 scopus 로고    scopus 로고
    • Characteristics of a label-free piezoelectric immunosensor detecting Pseudomonas aeruginosa
    • Kim N., Park I.-S., and Kim D.-K. Characteristics of a label-free piezoelectric immunosensor detecting Pseudomonas aeruginosa. Sens. Actuators B: Chem. 100 (2004) 432-438
    • (2004) Sens. Actuators B: Chem. , vol.100 , pp. 432-438
    • Kim, N.1    Park, I.-S.2    Kim, D.-K.3
  • 27
    • 70449102768 scopus 로고    scopus 로고
    • Detection of C-reactive protein using direct-binding quartz crystal microbalance immunosensor
    • Kim N., Kim D.-K., and Cho Y.-J. Detection of C-reactive protein using direct-binding quartz crystal microbalance immunosensor. Korean J. Biotechnol. Bioeng. 22 (2007) 443-446
    • (2007) Korean J. Biotechnol. Bioeng. , vol.22 , pp. 443-446
    • Kim, N.1    Kim, D.-K.2    Cho, Y.-J.3
  • 28
    • 84951279351 scopus 로고
    • Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung
    • Sauerbrey G. Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung. Z. Phys. 155 (1959) 206-222
    • (1959) Z. Phys. , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 30
    • 0017184389 scopus 로고
    • A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding
    • Bradford M.M. A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. Anal. Biochem. 72 (1976) 248-254
    • (1976) Anal. Biochem. , vol.72 , pp. 248-254
    • Bradford, M.M.1
  • 31
    • 0034351355 scopus 로고    scopus 로고
    • Evaluation of antibody immobilization methods for piezoelectric biosensor application
    • Babacan S., Pivarnik P., Letcher S., and Rand A.G. Evaluation of antibody immobilization methods for piezoelectric biosensor application. Biosens. Bioelectron. 15 (2000) 615-621
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 615-621
    • Babacan, S.1    Pivarnik, P.2    Letcher, S.3    Rand, A.G.4
  • 32
    • 35348875520 scopus 로고    scopus 로고
    • Flatfish vitellogenin detection using optical waveguide lightmode spectroscopy-based immunosensor
    • Kim N., Ryu H.-S., and Kim W.-Y. Flatfish vitellogenin detection using optical waveguide lightmode spectroscopy-based immunosensor. J. Microbiol. Biotechnol. 17 (2007) 1445-1451
    • (2007) J. Microbiol. Biotechnol. , vol.17 , pp. 1445-1451
    • Kim, N.1    Ryu, H.-S.2    Kim, W.-Y.3
  • 34
    • 2142770220 scopus 로고    scopus 로고
    • Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology
    • Koskinen J.O., Vaarno J., Meltola N.J., Soini J.T., Hänninen P.E., Luotola J., Waris M.E., and Soini A.E. Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology. Anal. Biochem. 328 (2004) 210-218
    • (2004) Anal. Biochem. , vol.328 , pp. 210-218
    • Koskinen, J.O.1    Vaarno, J.2    Meltola, N.J.3    Soini, J.T.4    Hänninen, P.E.5    Luotola, J.6    Waris, M.E.7    Soini, A.E.8
  • 35
    • 0242418180 scopus 로고    scopus 로고
    • Application of atomic force microscopy and grating coupler for the characterization of biosensor surfaces
    • Kuhlmeier D., Rodda E., Kolarik L.O., Furlong D.N., and Bilitewski R. Application of atomic force microscopy and grating coupler for the characterization of biosensor surfaces. Biosens. Bioelectron. 18 (2003) 925-936
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 925-936
    • Kuhlmeier, D.1    Rodda, E.2    Kolarik, L.O.3    Furlong, D.N.4    Bilitewski, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.