-
1
-
-
78650012419
-
Slowing the increase in the population dose resulting from CT scans
-
D.J. Brenner Slowing the increase in the population dose resulting from CT scans Radiation Research 174 6 2010 809 815
-
(2010)
Radiation Research
, vol.174
, Issue.6
, pp. 809-815
-
-
Brenner, D.J.1
-
2
-
-
36549007486
-
Computed tomography - An increasing source of radiation exposure
-
D.J. Brenner, and E.J. Hall Computed tomography - an increasing source of radiation exposure New England Journal of Medicine 357 22 2007 2277 2284
-
(2007)
New England Journal of Medicine
, vol.357
, Issue.22
, pp. 2277-2284
-
-
Brenner, D.J.1
Hall, E.J.2
-
3
-
-
0031972278
-
Iterative reconstruction for helical CT: A simulation study
-
J. Nuyts, B. De Man, P. Dupont, M. Defrise, P. Suetens, and L. Mortelmans Iterative reconstruction for helical CT: a simulation study Physics in Medicine & Biology 43 4 1998 729 737
-
(1998)
Physics in Medicine & Biology
, vol.43
, Issue.4
, pp. 729-737
-
-
Nuyts, J.1
De Man, B.2
Dupont, P.3
Defrise, M.4
Suetens, P.5
Mortelmans, L.6
-
4
-
-
35649025312
-
A three-dimensional statistical approach to improved image quality for multislice helical CT
-
J.B. Thibault, K.D. Sauer, C.A. Bouman, and J. Hsieh A three-dimensional statistical approach to improved image quality for multislice helical CT Medical Physics 34 11 2007 4526 4544
-
(2007)
Medical Physics
, vol.34
, Issue.11
, pp. 4526-4544
-
-
Thibault, J.B.1
Sauer, K.D.2
Bouman, C.A.3
Hsieh, J.4
-
5
-
-
84863693251
-
Contrast-to-noise ratio and low-contrast object resolution on full- and low-dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liver
-
M.E. Baker, F. Dong, and A. Primak Contrast-to-noise ratio and low-contrast object resolution on full- and low-dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liver American Journal of Roentgenology 199 1 2012 8 18
-
(2012)
American Journal of Roentgenology
, vol.199
, Issue.1
, pp. 8-18
-
-
Baker, M.E.1
Dong, F.2
Primak, A.3
-
6
-
-
84870380018
-
Low-dose CT of the lung: Potential value of iterative reconstructions
-
S. Baumueller, A. Winklehner, and C. Karlo Low-dose CT of the lung: potential value of iterative reconstructions European Radiology 12 2012 2597 2606
-
(2012)
European Radiology
, vol.12
, pp. 2597-2606
-
-
Baumueller, S.1
Winklehner, A.2
Karlo, C.3
-
7
-
-
77953710955
-
A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography
-
O. Gosling, R. Loader, and P. Venables A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative reconstruction, multislice CT coronary angiography with standard filtered back-projection and invasive diagnostic coronary angiography Heart 96 12 2010 922 926
-
(2010)
Heart
, vol.96
, Issue.12
, pp. 922-926
-
-
Gosling, O.1
Loader, R.2
Venables, P.3
-
8
-
-
80054034749
-
Lowering the dose in head CT using adaptive statistical iterative reconstruction
-
K. Kilic, G. Erbas, M. Guryildirim, M. Arac, E. Ilgit, and B. Coskun Lowering the dose in head CT using adaptive statistical iterative reconstruction American Journal of Neuroradiology 32 9 2011 1578 1582
-
(2011)
American Journal of Neuroradiology
, vol.32
, Issue.9
, pp. 1578-1582
-
-
Kilic, K.1
Erbas, G.2
Guryildirim, M.3
Arac, M.4
Ilgit, E.5
Coskun, B.6
-
9
-
-
84857246260
-
Iterative reconstruction in head CT: Image quality of routine and low-dose protocols in comparison with standard filtered back-projection
-
A. Korn, M. Fenchel, and B. Bender Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection American Journal of Neuroradiology 33 2 2012 218 224
-
(2012)
American Journal of Neuroradiology
, vol.33
, Issue.2
, pp. 218-224
-
-
Korn, A.1
Fenchel, M.2
Bender, B.3
-
10
-
-
78649700320
-
A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction
-
J. Leipsic, G. Nguyen, J. Brown, D. Sin, and J.R. Mayo A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction American Journal of Roentgenology 195 5 2010 1095 1099
-
(2010)
American Journal of Roentgenology
, vol.195
, Issue.5
, pp. 1095-1099
-
-
Leipsic, J.1
Nguyen, G.2
Brown, J.3
Sin, D.4
Mayo, J.R.5
-
11
-
-
79751526184
-
Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examinations in 80 patients
-
F. Pontana, A. Duhamel, and J. Pagniez Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examinations in 80 patients European Radiology 21 3 2011 636 643
-
(2011)
European Radiology
, vol.21
, Issue.3
, pp. 636-643
-
-
Pontana, F.1
Duhamel, A.2
Pagniez, J.3
-
12
-
-
84860241813
-
Cranial CT with adaptive statistical iterative reconstruction: Improved image quality with concomitant radiation dose reduction
-
O. Rapalino, S. Kamalian, and S. Kamalian Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction American Journal of Neuroradiology 33 4 2012 609 615
-
(2012)
American Journal of Neuroradiology
, vol.33
, Issue.4
, pp. 609-615
-
-
Rapalino, O.1
Kamalian, S.2
Kamalian, S.3
-
13
-
-
77956841482
-
Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
-
Y. Sagara, A.K. Hara, W. Pavlicek, A.C. Silva, R.G. Paden, and Q. Wu Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients American Journal of Roentgenology 195 3 2010 713 719
-
(2010)
American Journal of Roentgenology
, vol.195
, Issue.3
, pp. 713-719
-
-
Sagara, Y.1
Hara, A.K.2
Pavlicek, W.3
Silva, A.C.4
Paden, R.G.5
Wu, Q.6
-
14
-
-
74749087439
-
Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
-
A.C. Silva, H.J. Lawder, A. Hara, J. Kujak, and W. Pavlicek Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm American Journal of Roentgenology 194 1 2010 191 199
-
(2010)
American Journal of Roentgenology
, vol.194
, Issue.1
, pp. 191-199
-
-
Silva, A.C.1
Lawder, H.J.2
Hara, A.3
Kujak, J.4
Pavlicek, W.5
-
15
-
-
84873648140
-
The use of adaptive statistical iterative reconstruction in pediatric head CT: A feasibility study
-
G.A. Vorona, G. Zuccoli, T. Sutcavage, B.L. Clayton, R.C. Ceschin, and A. Panigrahy The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study American Journal of Neuroradiology 2013
-
(2013)
American Journal of Neuroradiology
-
-
Vorona, G.A.1
Zuccoli, G.2
Sutcavage, T.3
Clayton, B.L.4
Ceschin, R.C.5
Panigrahy, A.6
-
16
-
-
84861502180
-
Radiation dose reduction with sinogram affirmed iterative reconstruction technique for abdominal computed tomography
-
M.K. Kalra, M. Woisetschlager, and N. Dahlstrom Radiation dose reduction with sinogram affirmed iterative reconstruction technique for abdominal computed tomography Journal of Computer Assisted Tomography 36 3 2012 339 346
-
(2012)
Journal of Computer Assisted Tomography
, vol.36
, Issue.3
, pp. 339-346
-
-
Kalra, M.K.1
Woisetschlager, M.2
Dahlstrom, N.3
-
17
-
-
83555174941
-
Raw data-based iterative reconstruction in body CTA: Evaluation of radiation dose saving potential
-
A. Winklehner, C. Karlo, and G. Puippe Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential European Radiology 21 12 2011 2521 2526
-
(2011)
European Radiology
, vol.21
, Issue.12
, pp. 2521-2526
-
-
Winklehner, A.1
Karlo, C.2
Puippe, G.3
-
18
-
-
33846529471
-
National survey of doses from CT in the UK: 2003
-
P.C. Shrimpton, M.C. Hillier, M.A. Lewis, and M. Dunn National survey of doses from CT in the UK: 2003 British Journal of Radiology 79 948 2006 968 980
-
(2006)
British Journal of Radiology
, vol.79
, Issue.948
, pp. 968-980
-
-
Shrimpton, P.C.1
Hillier, M.C.2
Lewis, M.A.3
Dunn, M.4
-
19
-
-
11144355967
-
Comparison of image quality between conventional and low-dose nonenhanced head CT
-
M.E. Mullins, M.H. Lev, and P. Bove Comparison of image quality between conventional and low-dose nonenhanced head CT American Journal of Neuroradiology 25 4 2004 533 538
-
(2004)
American Journal of Neuroradiology
, vol.25
, Issue.4
, pp. 533-538
-
-
Mullins, M.E.1
Lev, M.H.2
Bove, P.3
-
20
-
-
42449104257
-
Low-dose nonenhanced head CT protocol for follow-up evaluation of children with ventriculoperitoneal shunt: Reduction of radiation and effect on image quality
-
U.K. Udayasankar, K. Braithwaite, and M. Arvaniti Low-dose nonenhanced head CT protocol for follow-up evaluation of children with ventriculoperitoneal shunt: reduction of radiation and effect on image quality American Journal of Neuroradiology 29 4 2008 802 806
-
(2008)
American Journal of Neuroradiology
, vol.29
, Issue.4
, pp. 802-806
-
-
Udayasankar, U.K.1
Braithwaite, K.2
Arvaniti, M.3
-
21
-
-
0014905513
-
Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and X-ray photography
-
R. Gordon, R. Bender, and G.T. Herman Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and X-ray photography Journal of Theoretical Biology 29 3 1970 471 481
-
(1970)
Journal of Theoretical Biology
, vol.29
, Issue.3
, pp. 471-481
-
-
Gordon, R.1
Bender, R.2
Herman, G.T.3
-
22
-
-
84881172444
-
Translation of statistical iterative reconstruction into non-linear image processing
-
H. Bruder, R.R. Sunnegardh, J. Stierstorfer, and K. Flohr T Translation of statistical iterative reconstruction into non-linear image processing RNSA 2010 2010
-
(2010)
RNSA 2010
-
-
Bruder, H.1
Sunnegardh, R.R.2
Stierstorfer, J.3
Flohr, T.K.4
-
23
-
-
84878743872
-
Iterative reconstruction techniques for computed tomography. Part 2. Initial results in dose reduction and image quality
-
Epub ahead of print
-
M.J. Willemink, T. Leiner, and P.A. de Jong Iterative reconstruction techniques for computed tomography. Part 2. Initial results in dose reduction and image quality European Radiology 2013 Epub ahead of print
-
(2013)
European Radiology
-
-
Willemink, M.J.1
Leiner, T.2
De Jong, P.A.3
-
24
-
-
84876366477
-
Reduced-dose low-voltage chest CT angiography with sinogram-affirmed iterative reconstruction vs. Standard-dose filtered back projection
-
Epub ahead of print
-
F. Pontana, J. Pagniez, and A. Duhamel Reduced-dose low-voltage chest CT angiography with sinogram-affirmed iterative reconstruction vs. standard-dose filtered back projection Radiology 2013 Epub ahead of print
-
(2013)
Radiology
-
-
Pontana, F.1
Pagniez, J.2
Duhamel, A.3
-
25
-
-
84881170964
-
Performance of iterative image reconstruction in CT of the paranasal sinuses: A Phantom study
-
Epub ahead of print
-
B. Schulz, M. Beeres, and B. Bodelle Performance of iterative image reconstruction in CT of the paranasal sinuses: a Phantom study American Journal of Neuroradiology 2012 Epub ahead of print
-
(2012)
American Journal of Neuroradiology
-
-
Schulz, B.1
Beeres, M.2
Bodelle, B.3
-
26
-
-
84856855191
-
Adaptive statistical iterative reconstruction vs filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose
-
L.M. Mitsumori, W.P. Shuman, J.M. Busey, O. Kolokythas, and Koprowicz KM Adaptive statistical iterative reconstruction vs. filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose European Radiology 22 1 2012 138 143
-
(2012)
European Radiology
, vol.22
, Issue.1
, pp. 138-143
-
-
Mitsumori, L.M.1
Shuman, W.P.2
Busey, J.M.3
Kolokythas, O.4
Km, K.5
-
27
-
-
84869870556
-
Dose reduction in chest CT: Comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques
-
Y. Yamada, M. Jinzaki, and T. Hosokawa Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques European Journal of Radiology 12 2012 4185 4195
-
(2012)
European Journal of Radiology
, vol.12
, pp. 4185-4195
-
-
Yamada, Y.1
Jinzaki, M.2
Hosokawa, T.3
|