-
1
-
-
0033395397
-
Infection control: The role of disinfection and sterilization
-
W. Rutala, and D. Weber Infection control: the role of disinfection and sterilization J. Hosp. Infect. 43 1999 S43 S55
-
(1999)
J. Hosp. Infect.
, vol.43
-
-
Rutala, W.1
Weber, D.2
-
2
-
-
0030159190
-
Disinfection and sterilization of patient-care items
-
W.A. Rutala Disinfection and sterilization of patient-care items Infect. Control Hosp. Epidemiol. 1996 377 384
-
(1996)
Infect. Control Hosp. Epidemiol.
, pp. 377-384
-
-
Rutala, W.A.1
-
3
-
-
0032176559
-
Clinical effectiveness of low-temperature sterilization technologies
-
W.A. Rutala, and D.J. Weber Clinical effectiveness of low-temperature sterilization technologies Infect. Control Hosp. Epidemiol. 1998 798 804
-
(1998)
Infect. Control Hosp. Epidemiol.
, pp. 798-804
-
-
Rutala, W.A.1
Weber, D.J.2
-
4
-
-
4143147534
-
Status of radiation sterilization of healthcare products in China
-
N. Zhu, C. Wang, and W. Teng Status of radiation sterilization of healthcare products in China Radiat. Phys. Chem. 71 1 2004 591 595
-
(2004)
Radiat. Phys. Chem.
, vol.71
, Issue.1
, pp. 591-595
-
-
Zhu, N.1
Wang, C.2
Teng, W.3
-
6
-
-
0033990205
-
Effects of sterilization processes on NiTi alloy: Surface characterization
-
B. Thierry Effects of sterilization processes on NiTi alloy: surface characterization J. Biomed. Mater. Res. 49 1 2000 88 98
-
(2000)
J. Biomed. Mater. Res.
, vol.49
, Issue.1
, pp. 88-98
-
-
Thierry, B.1
-
7
-
-
0023425004
-
Surface analysis of titanium after sterilization: Role in implant-tissue interface and bioadhesion
-
J.H. Doundoulakis Surface analysis of titanium after sterilization: role in implant-tissue interface and bioadhesion J. Prosthet. Dent. 58 4 1987 471 478
-
(1987)
J. Prosthet. Dent.
, vol.58
, Issue.4
, pp. 471-478
-
-
Doundoulakis, J.H.1
-
8
-
-
0028435141
-
Bone cell expression on titanium surfaces is altered by sterilization treatments
-
C. Stanford, J. Keller, and M. Solursh Bone cell expression on titanium surfaces is altered by sterilization treatments J. Dent. Res. 73 5 1994 1061 1071
-
(1994)
J. Dent. Res.
, vol.73
, Issue.5
, pp. 1061-1071
-
-
Stanford, C.1
Keller, J.2
Solursh, M.3
-
9
-
-
0030484525
-
Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium
-
P. Vezeau Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium J. Oral Maxillofac. Surg. 54 6 1996 738 746
-
(1996)
J. Oral Maxillofac. Surg.
, vol.54
, Issue.6
, pp. 738-746
-
-
Vezeau, P.1
-
10
-
-
0031296835
-
Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
-
J. Silvaggio, and M.L. Hicks Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files J. Endod. 23 12 1997 731 734
-
(1997)
J. Endod.
, vol.23
, Issue.12
, pp. 731-734
-
-
Silvaggio, J.1
Hicks, M.L.2
-
11
-
-
0032051064
-
Effect of passivation and dry heat-sterilization on surface energy and topography of unalloyed titanium implants
-
D.V. Kilpadi, J.J. Weimer, and J.E. Lemons Effect of passivation and dry heat-sterilization on surface energy and topography of unalloyed titanium implants Colloids Surf., A Physicochem. Eng. Asp. 135 1-3 1998 89 101
-
(1998)
Colloids Surf., A Physicochem. Eng. Asp.
, vol.135
, Issue.13
, pp. 89-101
-
-
Kilpadi, D.V.1
Weimer, J.J.2
Lemons, J.E.3
-
12
-
-
0034666762
-
Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
-
B. Thierry Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy J. Biomed. Mater. Res. 51 4 2000 685 693
-
(2000)
J. Biomed. Mater. Res.
, vol.51
, Issue.4
, pp. 685-693
-
-
Thierry, B.1
-
13
-
-
0141868995
-
Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids
-
A. Serro, and B. Saramago Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids Biomaterials 24 26 2003 4749 4760
-
(2003)
Biomaterials
, vol.24
, Issue.26
, pp. 4749-4760
-
-
Serro, A.1
Saramago, B.2
-
14
-
-
33747132889
-
Influence of sterilization on mechanical properties and fatigue resistance. Of nickel-titanium rotary endodontic instruments
-
A. Viana Influence of sterilization on mechanical properties and fatigue resistance.of nickel-titanium rotary endodontic instruments Int. Endod. J. 39 9 2006 709 715
-
(2006)
Int. Endod. J.
, vol.39
, Issue.9
, pp. 709-715
-
-
Viana, A.1
-
15
-
-
40949126963
-
The influence of blasting and sterilization on static and time-related wettability and surface-energy properties of titanium surfaces
-
M. Pegueroles The influence of blasting and sterilization on static and time-related wettability and surface-energy properties of titanium surfaces Surf. Coat. Technol. 202 15 2008 3470 3479
-
(2008)
Surf. Coat. Technol.
, vol.202
, Issue.15
, pp. 3470-3479
-
-
Pegueroles, M.1
-
16
-
-
67650914898
-
Effects of steam and dry-heat sterilization on bending properties of NiTi wires
-
S. Alavi, S.H. Raji, and A.A. Ghorbani Effects of steam and dry-heat sterilization on bending properties of NiTi wires Orthod. Waves 68 3 2009 123 128
-
(2009)
Orthod. Waves
, vol.68
, Issue.3
, pp. 123-128
-
-
Alavi, S.1
Raji, S.H.2
Ghorbani, A.A.3
-
17
-
-
79956146155
-
2 nanotubes
-
2 nanotubes Mater. Sci. Eng. C 31 5 2011 873 879
-
(2011)
Mater. Sci. Eng. C
, vol.31
, Issue.5
, pp. 873-879
-
-
Oh, S.1
-
18
-
-
0032775639
-
Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
-
S.M. Kurtz Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty Biomaterials 20 18 1999 1659 1688
-
(1999)
Biomaterials
, vol.20
, Issue.18
, pp. 1659-1688
-
-
Kurtz, S.M.1
-
19
-
-
0037086743
-
Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator
-
S. Affatato Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator Biomaterials 23 6 2002 1439 1446
-
(2002)
Biomaterials
, vol.23
, Issue.6
, pp. 1439-1446
-
-
Affatato, S.1
-
20
-
-
34249888759
-
Effect of ethylene oxide sterilization on enamel and dentin demineralization in vitro
-
R.Z. Thomas Effect of ethylene oxide sterilization on enamel and dentin demineralization in vitro J. Dent. 35 7 2007 547 551
-
(2007)
J. Dent.
, vol.35
, Issue.7
, pp. 547-551
-
-
Thomas, R.Z.1
-
21
-
-
33751345416
-
Effects of sterilisation method on surface topography and in-vitro cell behaviour of electrostatically spun scaffolds
-
K.D. Andrews, J.A. Hunt, and R.A. Black Effects of sterilisation method on surface topography and in-vitro cell behaviour of electrostatically spun scaffolds Biomaterials 28 6 2007 1014 1026
-
(2007)
Biomaterials
, vol.28
, Issue.6
, pp. 1014-1026
-
-
Andrews, K.D.1
Hunt, J.A.2
Black, R.A.3
-
22
-
-
77954664452
-
The history of biodegradable magnesium implants: A review
-
F. Witte The history of biodegradable magnesium implants: a review Acta Biomater. 6 5 2010 1680 1692
-
(2010)
Acta Biomater.
, vol.6
, Issue.5
, pp. 1680-1692
-
-
Witte, F.1
-
23
-
-
72049128611
-
Cerium-based coating for enhancing the corrosion resistance of bio-degradable Mg implants
-
W.F. Ng, M.H. Wong, and F. Cheng Cerium-based coating for enhancing the corrosion resistance of bio-degradable Mg implants Mater. Chem. Phys. 119 3 2010 384 388
-
(2010)
Mater. Chem. Phys.
, vol.119
, Issue.3
, pp. 384-388
-
-
Ng, W.F.1
Wong, M.H.2
Cheng, F.3
-
24
-
-
77955511929
-
In vitro corrosion degradation behaviour of Mg-Ca alloy in the presence of albumin
-
C. Liu In vitro corrosion degradation behaviour of Mg-Ca alloy in the presence of albumin Corros. Sci. 52 10 2010 3341 3347
-
(2010)
Corros. Sci.
, vol.52
, Issue.10
, pp. 3341-3347
-
-
Liu, C.1
-
25
-
-
77953081471
-
In vivo corrosion and corrosion protection of magnesium alloy LAE442
-
F. Witte In vivo corrosion and corrosion protection of magnesium alloy LAE442 Acta Biomater. 6 5 2010 1792 1799
-
(2010)
Acta Biomater.
, vol.6
, Issue.5
, pp. 1792-1799
-
-
Witte, F.1
-
26
-
-
77955428235
-
Mechanical properties and phase composition of potential biodegradable Mg-Zn-Mn-base alloys with addition of rare earth elements
-
I. Stulikova, and B. Smola Mechanical properties and phase composition of potential biodegradable Mg-Zn-Mn-base alloys with addition of rare earth elements Mater. Charact. 61 10 2010 952 958
-
(2010)
Mater. Charact.
, vol.61
, Issue.10
, pp. 952-958
-
-
Stulikova, I.1
Smola, B.2
-
27
-
-
40649099051
-
In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid
-
M.B. Kannan, and R. Raman In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid Biomaterials 29 15 2008 2306 2314
-
(2008)
Biomaterials
, vol.29
, Issue.15
, pp. 2306-2314
-
-
Kannan, M.B.1
Raman, R.2
-
28
-
-
77953082632
-
In vitro responses of human bone marrow stromal cells to a fluoridated hydroxyapatite coated biodegradable Mg-Zn alloy
-
J. Li In vitro responses of human bone marrow stromal cells to a fluoridated hydroxyapatite coated biodegradable Mg-Zn alloy Biomaterials 31 22 2010 5782 5788
-
(2010)
Biomaterials
, vol.31
, Issue.22
, pp. 5782-5788
-
-
Li, J.1
-
29
-
-
68949083075
-
Effect of surface pre-treatments on biocompatibility of magnesium
-
C. Lorenz Effect of surface pre-treatments on biocompatibility of magnesium Acta Biomater. 5 7 2009 2783 2789
-
(2009)
Acta Biomater.
, vol.5
, Issue.7
, pp. 2783-2789
-
-
Lorenz, C.1
-
30
-
-
83455250600
-
The effect of different sterilization methods on the mechanical strength of magnesium based implant materials
-
J.M. Seitz The effect of different sterilization methods on the mechanical strength of magnesium based implant materials Adv. Eng. Mater. 13 12 2011 1146 1151
-
(2011)
Adv. Eng. Mater.
, vol.13
, Issue.12
, pp. 1146-1151
-
-
Seitz, J.M.1
-
31
-
-
44349143772
-
Cleaning, disinfection and sterilization of equipment
-
S. Lewis, and A.K. McIndoe Cleaning, disinfection and sterilization of equipment Anaesth. Intensive Care Med. 5 11 2004 360 363
-
(2004)
Anaesth. Intensive Care Med.
, vol.5
, Issue.11
, pp. 360-363
-
-
Lewis, S.1
McIndoe, A.K.2
-
32
-
-
84881141417
-
-
OSHA, Best practices for the safe use of glutaraldehyde in health care. OSHA 3258-3308.N, 2006 (available from). Accessed on 1 November 2006.
-
OSHA, Best practices for the safe use of glutaraldehyde in health care. OSHA 3258-3308.N, 2006 (available from www.osha.gov/Publications/glutaraldehyde. pdf). Accessed on 1 November 2006.
-
-
-
-
33
-
-
58149087080
-
Surficial phase-identification and structural profiles from weathered natural pyrites: A grazing-incidence X-ray diffraction study
-
Y. Cai Surficial phase-identification and structural profiles from weathered natural pyrites: a grazing-incidence X-ray diffraction study Appl. Surf. Sci. 255 7 2009 4066 4073
-
(2009)
Appl. Surf. Sci.
, vol.255
, Issue.7
, pp. 4066-4073
-
-
Cai, Y.1
-
34
-
-
45049087902
-
Preparation and characterization of a new biomedical magnesium-calcium alloy
-
Y. Wan Preparation and characterization of a new biomedical magnesium-calcium alloy Mater. Des. 29 10 2008 2034 2037
-
(2008)
Mater. Des.
, vol.29
, Issue.10
, pp. 2034-2037
-
-
Wan, Y.1
-
35
-
-
78449279418
-
In-vitro dissolution of magnesium-calcium binary alloys: Clarifying the unique role of calcium additions in bioresorbable magnesium implant alloys
-
N.T. Kirkland In-vitro dissolution of magnesium-calcium binary alloys: clarifying the unique role of calcium additions in bioresorbable magnesium implant alloys J. Biomed. Mater. Res. B Appl. Biomater. 95 1 2010 91 100
-
(2010)
J. Biomed. Mater. Res. B Appl. Biomater.
, vol.95
, Issue.1
, pp. 91-100
-
-
Kirkland, N.T.1
-
36
-
-
34247850895
-
Effects of surface wettability and contact time on protein adhesion to biomaterial surfaces
-
L.C. Xu, and C.A. Siedlecki Effects of surface wettability and contact time on protein adhesion to biomaterial surfaces Biomaterials 28 22 2007 3273 3283
-
(2007)
Biomaterials
, vol.28
, Issue.22
, pp. 3273-3283
-
-
Xu, L.C.1
Siedlecki, C.A.2
-
37
-
-
56549090894
-
In vitro corrosion and biocompatibility of binary magnesium alloys
-
X. Gu In vitro corrosion and biocompatibility of binary magnesium alloys Biomaterials 30 4 2009 484 498
-
(2009)
Biomaterials
, vol.30
, Issue.4
, pp. 484-498
-
-
Gu, X.1
|