1
-
-
0038486163
-
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
-
Heublein B., Rohde R., Kaese V., Niemeyer M., Hartung W., and Haverich A. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?. Heart 89 (2003) 651-656
-
(2003)
Heart
, vol.89
, pp. 651-656
-
-
Heublein, B.1
Rohde, R.2
Kaese, V.3
Niemeyer, M.4
Hartung, W.5
Haverich, A.6
-
2
-
-
11144301699
-
In vivo corrosion of four magnesium alloys and the associated bone response
-
Witte F., Kaese V., Haferkamp H., Switzer E., Meyer-Lindenberg A., Wirth C.J., et al. In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials 26 (2005) 3557-3563
-
(2005)
Biomaterials
, vol.26
, pp. 3557-3563
-
-
Witte, F.1
Kaese, V.2
Haferkamp, H.3
Switzer, E.4
Meyer-Lindenberg, A.5
Wirth, C.J.6
-
3
-
-
28244479917
-
Metallic bioabsorbable stents: concepts, experimental findings, early clinical results, and the future
-
Waksman R. Metallic bioabsorbable stents: concepts, experimental findings, early clinical results, and the future. ACC Rev 14 (2005) 36-43
-
(2005)
ACC Rev
, vol.14
, pp. 36-43
-
-
Waksman, R.1
-
4
-
-
28844481103
-
Magnesium and its alloys as orthopedic biomaterials: a review
-
Staiger M.P., Pietak A.M., Huadmai J., and Dias G. Magnesium and its alloys as orthopedic biomaterials: a review. Biomaterials 27 (2006) 1728-1734
-
(2006)
Biomaterials
, vol.27
, pp. 1728-1734
-
-
Staiger, M.P.1
Pietak, A.M.2
Huadmai, J.3
Dias, G.4
-
5
-
-
33745736221
-
Cartilage repair on magnesium scaffolds used as a subchondral bone replacement
-
Witte F., Reifenrath J., Muller P.P., Crostack H.-A., Nellesen J., Bach F.W., et al. Cartilage repair on magnesium scaffolds used as a subchondral bone replacement. Mat wiss u Werkstofftech 37 (2006) 504-508
-
(2006)
Mat wiss u Werkstofftech
, vol.37
, pp. 504-508
-
-
Witte, F.1
Reifenrath, J.2
Muller, P.P.3
Crostack, H.-A.4
Nellesen, J.5
Bach, F.W.6
-
6
-
-
33746035363
-
New interests in magnesium
-
Williams D. New interests in magnesium. Med Device Technol 17 (2006) 9-10
-
(2006)
Med Device Technol
, vol.17
, pp. 9-10
-
-
Williams, D.1
-
7
-
-
31144443232
-
The road to bioabsorbable stents: reaching clinical reality?
-
Erne P., Schier M., and Resink T.J. The road to bioabsorbable stents: reaching clinical reality?. Cardiovasc Intervent Radiol 29 (2006) 11-16
-
(2006)
Cardiovasc Intervent Radiol
, vol.29
, pp. 11-16
-
-
Erne, P.1
Schier, M.2
Resink, T.J.3
-
8
-
-
27644597192
-
In vitro and in vivo corrosion measurements of magnesium alloys
-
Witte F., Fischer J., Nellesen J., Crostack H.-A., Kaese V., Pisch A., et al. In vitro and in vivo corrosion measurements of magnesium alloys. Biomaterials 27 (2006) 1013-1018
-
(2006)
Biomaterials
, vol.27
, pp. 1013-1018
-
-
Witte, F.1
Fischer, J.2
Nellesen, J.3
Crostack, H.-A.4
Kaese, V.5
Pisch, A.6
-
9
-
-
34249010154
-
Biodegradable magnesium scaffolds. Part I: appropriate inflammatory response
-
Witte F., Ulrich H., Rudert M., and Willbold E. Biodegradable magnesium scaffolds. Part I: appropriate inflammatory response. J Biomed Mater Res 81A (2007) 748-756
-
(2007)
J Biomed Mater Res
, vol.81 A
, pp. 748-756
-
-
Witte, F.1
Ulrich, H.2
Rudert, M.3
Willbold, E.4
-
10
-
-
34249086513
-
Biodegradable magnesium scaffolds. Part II: peri-implant bone remodeling
-
Witte F., Ulrich H., Palm C., and Willbold E. Biodegradable magnesium scaffolds. Part II: peri-implant bone remodeling. J Biomed Mater Res 81A (2007) 757-765
-
(2007)
J Biomed Mater Res
, vol.81 A
, pp. 757-765
-
-
Witte, F.1
Ulrich, H.2
Palm, C.3
Willbold, E.4
-
11
-
-
36049039216
-
In vivo corrosion behavior of Mg-Mn-Zn alloy for bone implant application
-
Xu L., Yu G., Zhang E., Pan F., and Yang K. In vivo corrosion behavior of Mg-Mn-Zn alloy for bone implant application. J Biomedical Mater Res 83A (2007) 703-711
-
(2007)
J Biomedical Mater Res
, vol.83 A
, pp. 703-711
-
-
Xu, L.1
Yu, G.2
Zhang, E.3
Pan, F.4
Yang, K.5
-
12
-
-
33847354676
-
First biodegradable metal stent in a child with congenital heart disease: evaluation of macro and histopathology
-
Zartner P., Buettner M., Singer H., and Sigler M. First biodegradable metal stent in a child with congenital heart disease: evaluation of macro and histopathology. Catheter Cardiovasc Interv 69 (2007) 443-446
-
(2007)
Catheter Cardiovasc Interv
, vol.69
, pp. 443-446
-
-
Zartner, P.1
Buettner, M.2
Singer, H.3
Sigler, M.4
-
13
-
-
34249655184
-
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial
-
Erbel R., di Mario C., Bartunek J., Bonnier J.J., de Bruyne B., Eberli F.R., et al. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet 369 (2007) 1869-1875
-
(2007)
Lancet
, vol.369
, pp. 1869-1875
-
-
Erbel, R.1
di Mario, C.2
Bartunek, J.3
Bonnier, J.J.4
de Bruyne, B.5
Eberli, F.R.6
-
14
-
-
34249744766
-
Magnesium and its alloys as degradable biomaterials. Corrosion studies using potentiodynamic and EIS electrochemical techniques
-
Müller W.D., Nascimento M.L., Zeddies M., Corsico M., Gassa L.M., and de Mele M.A.F.L. Magnesium and its alloys as degradable biomaterials. Corrosion studies using potentiodynamic and EIS electrochemical techniques. Mater Res 10 (2007) 5-10
-
(2007)
Mater Res
, vol.10
, pp. 5-10
-
-
Müller, W.D.1
Nascimento, M.L.2
Zeddies, M.3
Corsico, M.4
Gassa, L.M.5
de Mele, M.A.F.L.6
-
15
-
-
51049100840
-
Progress and challenge for magnesium alloys as biomaterials
-
Zheng R., Dietzel W., Witte F., Hart N., and Blawert C. Progress and challenge for magnesium alloys as biomaterials. Adv Eng Mater 10 (2008) B3-B14
-
(2008)
Adv Eng Mater
, vol.10
-
-
Zheng, R.1
Dietzel, W.2
Witte, F.3
Hart, N.4
Blawert, C.5
-
16
-
-
56249142877
-
Fix, heal and repair-a new approach to using metals in the human body
-
Sikora E., Shaw B., and Virtanen S. Fix, heal and repair-a new approach to using metals in the human body. Interface 17 (2008) 45-49
-
(2008)
Interface
, vol.17
, pp. 45-49
-
-
Sikora, E.1
Shaw, B.2
Virtanen, S.3
-
17
-
-
0033196585
-
Corrosion mechanisms of magnesium alloys
-
Song G.L., and Atrens A. Corrosion mechanisms of magnesium alloys. Adv Eng Mater 1 (1999) 11-33
-
(1999)
Adv Eng Mater
, vol.1
, pp. 11-33
-
-
Song, G.L.1
Atrens, A.2
-
18
-
-
1342283923
-
Understanding magnesium corrosion-a framework for improved alloy performance
-
Song G.L., and Atrens A. Understanding magnesium corrosion-a framework for improved alloy performance. Adv Eng Mater 5 (2003) 837-858
-
(2003)
Adv Eng Mater
, vol.5
, pp. 837-858
-
-
Song, G.L.1
Atrens, A.2
-
19
-
-
33846799472
-
Biodegradable magnesium-hydroxyapatite metal matrix composites
-
Witte F., Feyerabend F., Maier P., Fischer J., Störmer M., Blawert C., et al. Biodegradable magnesium-hydroxyapatite metal matrix composites. Biomaterials 28 (2007) 2163-2174
-
(2007)
Biomaterials
, vol.28
, pp. 2163-2174
-
-
Witte, F.1
Feyerabend, F.2
Maier, P.3
Fischer, J.4
Störmer, M.5
Blawert, C.6
-
20
-
-
3042641324
-
Evaluation of cyto-toxicity and corrosion behavior of alkali-heat-treated magnesium in simulated body fluid
-
Li L., Gao J., and Wang Y. Evaluation of cyto-toxicity and corrosion behavior of alkali-heat-treated magnesium in simulated body fluid. Surf Coating Technol 185 (2004) 92-98
-
(2004)
Surf Coating Technol
, vol.185
, pp. 92-98
-
-
Li, L.1
Gao, J.2
Wang, Y.3
-
21
-
-
68949094793
-
Corrosion resistance and cytocompatibility of biodegradable surgical magnesium alloy coated with hydrogenated amorphous silicon
-
in press
-
Xin Y, Jiang J, Huo K, Tang G, Tian X, Chu PK. Corrosion resistance and cytocompatibility of biodegradable surgical magnesium alloy coated with hydrogenated amorphous silicon. J Biomed Mat Res A, in press.
-
J Biomed Mat Res A
-
-
Xin, Y.1
Jiang, J.2
Huo, K.3
Tang, G.4
Tian, X.5
Chu, P.K.6
-
22
-
-
38349153562
-
The development of binary Mg-Ca alloys for use as biodegradable materials within bone
-
Li Z., Gu X., Lou S., and Zheng Y. The development of binary Mg-Ca alloys for use as biodegradable materials within bone. Biomaterials 29 (2008) 1329-1344
-
(2008)
Biomaterials
, vol.29
, pp. 1329-1344
-
-
Li, Z.1
Gu, X.2
Lou, S.3
Zheng, Y.4
-
23
-
-
56549090894
-
In vitro corrosion and biocompatibility of binary magnesium alloys
-
Gu X., Zheng Y., Cheng Y., Zhong S., and Xi T. In vitro corrosion and biocompatibility of binary magnesium alloys. Biomaterials 30 (2009) 484-498
-
(2009)
Biomaterials
, vol.30
, pp. 484-498
-
-
Gu, X.1
Zheng, Y.2
Cheng, Y.3
Zhong, S.4
Xi, T.5
-
24
-
-
0347545262
-
Preparation and assessment of revised simulated body fluids
-
Oyane A., Kim H.M., Furuya T., Kokubo T., Miyazaki T., and Nakamura T. Preparation and assessment of revised simulated body fluids. J Biomed Mater Res 65 (2003) 188-195
-
(2003)
J Biomed Mater Res
, vol.65
, pp. 188-195
-
-
Oyane, A.1
Kim, H.M.2
Furuya, T.3
Kokubo, T.4
Miyazaki, T.5
Nakamura, T.6
-
25
-
-
38349006659
-
Spontaneous and biomimetic apatite formation on pure magnesium
-
Cortes D.A., Lopez H.Y., and Mantovani D. Spontaneous and biomimetic apatite formation on pure magnesium. Mater Sci Forum 539-543 (2007) 589-594
-
(2007)
Mater Sci Forum
, vol.539-543
, pp. 589-594
-
-
Cortes, D.A.1
Lopez, H.Y.2
Mantovani, D.3
-
26
-
-
52949129094
-
Precipitation control of calcium phosphate on pure magnesium by anodization
-
Hiromoto S., Shishido T., Yamamoto A., Maruyama N., Somekawa H., and Mukai T. Precipitation control of calcium phosphate on pure magnesium by anodization. Corrosion Sci 50 (2008) 2906-2913
-
(2008)
Corrosion Sci
, vol.50
, pp. 2906-2913
-
-
Hiromoto, S.1
Shishido, T.2
Yamamoto, A.3
Maruyama, N.4
Somekawa, H.5
Mukai, T.6
-
27
-
-
58149373931
-
Composition of corrosion layers on the magnesium rare-earth alloy in simulated body fluids
-
Rettig R., and Virtanen S. Composition of corrosion layers on the magnesium rare-earth alloy in simulated body fluids. J. Biomed Mater Res 88A (2009) 359-369
-
(2009)
J. Biomed Mater Res
, vol.88 A
, pp. 359-369
-
-
Rettig, R.1
Virtanen, S.2
-
28
-
-
40449134564
-
Time-dependent electrochemical characterization of the corrosion of the magnesium rare-earth alloy in simulated body fluids
-
Rettig R., and Virtanen S. Time-dependent electrochemical characterization of the corrosion of the magnesium rare-earth alloy in simulated body fluids. J. Biomed Mater Res 85A (2008) 167-175
-
(2008)
J. Biomed Mater Res
, vol.85 A
, pp. 167-175
-
-
Rettig, R.1
Virtanen, S.2
|