-
1
-
-
0036109223
-
CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
-
ELCAP Group
-
Henschke CI, Yankelevitz DF, Mirtcheva R, McGuinness G, McCauley D, Miettinen OS; ELCAP Group. CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. AJR Am J Roentgenol 2002;178:1053-1057
-
(2002)
AJR Am J Roentgenol
, vol.178
, pp. 1053-1057
-
-
Henschke, C.I.1
Yankelevitz, D.F.2
Mirtcheva, R.3
McGuinness, G.4
McCauley, D.5
Miettinen, O.S.6
-
2
-
-
34247233915
-
Nodular ground-glass opacity at thin-section CT: Histologic correlation and evaluation of change at follow-up
-
Park CM, Goo JM, Lee HJ, Lee CH, Chun EJ, Im JG. Nodular ground-glass opacity at thin-section CT: histologic correlation and evaluation of change at follow-up. Radiographics 2007;27:391-408
-
(2007)
Radiographics
, vol.27
, pp. 391-408
-
-
Park, C.M.1
Goo, J.M.2
Lee, H.J.3
Lee, C.H.4
Chun, E.J.5
Im, J.G.6
-
3
-
-
59949103452
-
Predictive CT findings of malignancy in ground-glass nodules on thin-section chest CT: The effects on radiologist performance
-
Lee HJ, Goo JM, Lee CH, Park CM, Kim KG, Park EA, et al. Predictive CT findings of malignancy in ground-glass nodules on thin-section chest CT: the effects on radiologist performance. Eur Radiol 2009;19:552-560
-
(2009)
Eur Radiol
, vol.19
, pp. 552-560
-
-
Lee, H.J.1
Goo, J.M.2
Lee, C.H.3
Park, C.M.4
Kim, K.G.5
Park, E.A.6
-
4
-
-
34548672818
-
Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons
-
Kim HY, Shim YM, Lee KS, Han J, Yi CA, Kim YK. Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons. Radiology 2007;245:267-275
-
(2007)
Radiology
, vol.245
, pp. 267-275
-
-
Kim, H.Y.1
Shim, Y.M.2
Lee, K.S.3
Han, J.4
Yi, C.A.5
Kim, Y.K.6
-
5
-
-
33846589945
-
Positron emission tomography in relation to Noguchi's classification for diagnosis of peripheral non-small-cell lung cancer 2 cm or less in size
-
Tsunezuka Y, Shimizu Y, Tanaka N, Takayanagi T, Kawano M. Positron emission tomography in relation to Noguchi's classification for diagnosis of peripheral non-small-cell lung cancer 2 cm or less in size. World J Surg 2007;31:314-317
-
(2007)
World J Surg
, vol.31
, pp. 314-317
-
-
Tsunezuka, Y.1
Shimizu, Y.2
Tanaka, N.3
Takayanagi, T.4
Kawano, M.5
-
6
-
-
77950427436
-
Pulmonary ground-glass nodules: Increase in mass as an early indicator of growth
-
de Hoop B, Gietema H, van de Vorst S, Murphy K, van Klaveren RJ, Prokop M. Pulmonary ground-glass nodules: increase in mass as an early indicator of growth. Radiology 2010;255:199-206
-
(2010)
Radiology
, vol.255
, pp. 199-206
-
-
de Hoop, B.1
Gietema, H.2
van de Vorst, S.3
Murphy, K.4
van Klaveren, R.J.5
Prokop, M.6
-
7
-
-
79952978288
-
A computer-aided diagnosis for evaluating lung nodules on chest CT: The current status and perspective
-
Goo JM. A computer-aided diagnosis for evaluating lung nodules on chest CT: the current status and perspective. Korean J Radiol 2011;12:145-155
-
(2011)
Korean J Radiol
, vol.12
, pp. 145-155
-
-
Goo, J.M.1
-
8
-
-
76149092829
-
Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT
-
Oda S, Awai K, Murao K, Ozawa A, Yanaga Y, Kawanaka K, et al. Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT. AJR Am J Roentgenol 2010;194:398-406
-
(2010)
AJR Am J Roentgenol
, vol.194
, pp. 398-406
-
-
Oda, S.1
Awai, K.2
Murao, K.3
Ozawa, A.4
Yanaga, Y.5
Kawanaka, K.6
-
9
-
-
78649731914
-
Persistent pure ground-glass nodules in the lung: Interscan variability of semiautomated volume and attenuation measurements
-
Park CM, Goo JM, Lee HJ, Kim KG, Kang MJ, Shin YH. Persistent pure ground-glass nodules in the lung: interscan variability of semiautomated volume and attenuation measurements. AJR Am J Roentgenol 2010;195:W408-W414
-
(2010)
AJR Am J Roentgenol
, vol.195
-
-
Park, C.M.1
Goo, J.M.2
Lee, H.J.3
Kim, K.G.4
Kang, M.J.5
Shin, Y.H.6
-
10
-
-
62649137035
-
A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
-
de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M. A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 2009;19:800-808
-
(2009)
Eur Radiol
, vol.19
, pp. 800-808
-
-
de Hoop, B.1
Gietema, H.2
van Ginneken, B.3
Zanen, P.4
Groenewegen, G.5
Prokop, M.6
-
11
-
-
54049112242
-
Performance evaluation of 4 measuring methods of ground-glass opacities for predicting the 5-year relapse-free survival of patients with peripheral nonsmall cell lung cancer: A multicenter study
-
Kakinuma R, Kodama K, Yamada K, Yokoyama A, Adachi S, Mori K, et al. Performance evaluation of 4 measuring methods of ground-glass opacities for predicting the 5-year relapse-free survival of patients with peripheral nonsmall cell lung cancer: a multicenter study. J Comput Assist Tomogr 2008;32:792-798
-
(2008)
J Comput Assist Tomogr
, vol.32
, pp. 792-798
-
-
Kakinuma, R.1
Kodama, K.2
Yamada, K.3
Yokoyama, A.4
Adachi, S.5
Mori, K.6
-
12
-
-
49049092638
-
Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program
-
Wang Y, van Klaveren RJ, van der Zaag-Loonen HJ, de Bock GH, Gietema HA, Xu DM, et al. Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program. Radiology 2008;248:625-631
-
(2008)
Radiology
, vol.248
, pp. 625-631
-
-
Wang, Y.1
van Klaveren, R.J.2
van der Zaag-Loonen, H.J.3
de Bock, G.H.4
Gietema, H.A.5
Xu, D.M.6
-
14
-
-
0141954913
-
Threedimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images
-
Kostis WJ, Reeves AP, Yankelevitz DF, Henschke CI. Threedimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images. IEEE Trans Med Imaging 2003;22:1259-1274
-
(2003)
IEEE Trans Med Imaging
, vol.22
, pp. 1259-1274
-
-
Kostis, W.J.1
Reeves, A.P.2
Yankelevitz, D.F.3
Henschke, C.I.4
-
15
-
-
34248632699
-
Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
-
Das M, Ley-Zaporozhan J, Gietema HA, Czech A, Mühlenbruch G, Mahnken AH, et al. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners. Eur Radiol 2007;17:1979-1984
-
(2007)
Eur Radiol
, vol.17
, pp. 1979-1984
-
-
Das, M.1
Ley-Zaporozhan, J.2
Gietema, H.A.3
Czech, A.4
Mühlenbruch, G.5
Mahnken, A.H.6
-
16
-
-
33846527920
-
Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology
-
Petrou M, Quint LE, Nan B, Baker LH. Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology. AJR Am J Roentgenol 2007;188:306-312
-
(2007)
AJR Am J Roentgenol
, vol.188
, pp. 306-312
-
-
Petrou, M.1
Quint, L.E.2
Nan, B.3
Baker, L.H.4
-
17
-
-
73949120189
-
Subsolid pulmonary nodules and the spectrum of peripheral adenocarcinomas of the lung: Recommended interim guidelines for assessment and management
-
Godoy MC, Naidich DP. Subsolid pulmonary nodules and the spectrum of peripheral adenocarcinomas of the lung: recommended interim guidelines for assessment and management. Radiology 2009;253:606-622
-
(2009)
Radiology
, vol.253
, pp. 606-622
-
-
Godoy, M.C.1
Naidich, D.P.2
-
18
-
-
79551563284
-
International association for the study of lung cancer/american thoracic society/european respiratory society international multidisciplinary classification of lung adenocarcinoma
-
Travis WD, Brambilla E, Noguchi M, Nicholson AG, Geisinger KR, Yatabe Y, et al. International association for the study of lung cancer/american thoracic society/european respiratory society international multidisciplinary classification of lung adenocarcinoma. J Thorac Oncol 2011;6:244-285
-
(2011)
J Thorac Oncol
, vol.6
, pp. 244-285
-
-
Travis, W.D.1
Brambilla, E.2
Noguchi, M.3
Nicholson, A.G.4
Geisinger, K.R.5
Yatabe, Y.6
-
19
-
-
1942438249
-
Simultaneous truth and performance level estimation (STAPLE): An algorithm for the validation of image segmentation
-
Warfield SK, Zou KH, Wells WM. Simultaneous truth and performance level estimation (STAPLE): an algorithm for the validation of image segmentation. IEEE Trans Med Imaging 2004;23:903-921
-
(2004)
IEEE Trans Med Imaging
, vol.23
, pp. 903-921
-
-
Warfield, S.K.1
Zou, K.H.2
Wells, W.M.3
-
20
-
-
79960349087
-
Comparison of manual and automatic segmentation methods for brain structures in the presence of spaceoccupying lesions: A multi-expert study
-
Deeley MA, Chen A, Datteri R, Noble JH, Cmelak AJ, Donnelly EF, et al. Comparison of manual and automatic segmentation methods for brain structures in the presence of spaceoccupying lesions: a multi-expert study. Phys Med Biol 2011;56:4557-4577
-
(2011)
Phys Med Biol
, vol.56
, pp. 4557-4577
-
-
Deeley, M.A.1
Chen, A.2
Datteri, R.3
Noble, J.H.4
Cmelak, A.J.5
Donnelly, E.F.6
|