메뉴 건너뛰기




Volumn 46, Issue 12, 2013, Pages 963-968

A comparison of capture antibody fragments in cardiac troponin I immunoassay

Author keywords

Antibody fragment; Cardiac troponin I; Heterophilic antibody; Human anti mouse antibodies; Immunoassay; Nanoparticle

Indexed keywords

EUROPIUM; HEPARIN; IMMOBILIZED ANTIBODY; IMMUNOGLOBULIN F(AB) FRAGMENT; NANOPARTICLE; STREPTAVIDIN; TROPONIN I;

EID: 84880585856     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2013.01.012     Document Type: Article
Times cited : (25)

References (33)
  • 1
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka L.J. Human anti-animal antibody interferences in immunological assays. Clin Chem 1999, 45:942-956.
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 2
    • 25144458776 scopus 로고    scopus 로고
    • Interferences in immunoassay
    • Tate J., Ward G. Interferences in immunoassay. Clin Biochem Rev 2004, 25:105-120.
    • (2004) Clin Biochem Rev , vol.25 , pp. 105-120
    • Tate, J.1    Ward, G.2
  • 3
    • 17044410426 scopus 로고    scopus 로고
    • Human heterophilic antibodies display specificity for murine IgG subclasses
    • Bjerner J., Olsen K.H., Børmer O.P., Nustad K. Human heterophilic antibodies display specificity for murine IgG subclasses. Clin Biochem 2005, 38:465-472.
    • (2005) Clin Biochem , vol.38 , pp. 465-472
    • Bjerner, J.1    Olsen, K.H.2    Børmer, O.P.3    Nustad, K.4
  • 4
    • 0033970391 scopus 로고    scopus 로고
    • Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies
    • Yeo K.T., Storm C.A., Li Y., Jayne J.E., Quinn-Hall KS Brough T., Fitzmaurice T.F. Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies. Clin Chim Acta 2000, 292:13-23.
    • (2000) Clin Chim Acta , vol.292 , pp. 13-23
    • Yeo, K.T.1    Storm, C.A.2    Li, Y.3    Jayne, J.E.4    Quinn-Hall, K.S.B.T.5    Fitzmaurice, T.F.6
  • 5
    • 0037094123 scopus 로고    scopus 로고
    • False-positive cardiac troponin I in a routine clinical population
    • Fleming S.M., O'Byrne L., Finn J., Grimes H., Daly K.M. False-positive cardiac troponin I in a routine clinical population. Am J Cardiol 2002, 89:1212-1215.
    • (2002) Am J Cardiol , vol.89 , pp. 1212-1215
    • Fleming, S.M.1    O'Byrne, L.2    Finn, J.3    Grimes, H.4    Daly, K.M.5
  • 7
    • 33750464023 scopus 로고    scopus 로고
    • Development and preliminary clinical validation of a high sensitivity assay for cardiac troponin using a capillary flow (single molecule) fluorescence detector
    • Wu A.H.B., Fukushima N., Puskas R., Todd J., Goix P. Development and preliminary clinical validation of a high sensitivity assay for cardiac troponin using a capillary flow (single molecule) fluorescence detector. Clin Chem 2006, 52:2157-2159.
    • (2006) Clin Chem , vol.52 , pp. 2157-2159
    • Wu, A.H.B.1    Fukushima, N.2    Puskas, R.3    Todd, J.4    Goix, P.5
  • 8
    • 70049089306 scopus 로고    scopus 로고
    • Normal plasma levels of cardiac troponin I measured by the high-sensitivity cardiac troponin I access prototype assay and the impact on the diagnosis of myocardial ischemia
    • Venge P., Johnston N., Lindahl B., James S. Normal plasma levels of cardiac troponin I measured by the high-sensitivity cardiac troponin I access prototype assay and the impact on the diagnosis of myocardial ischemia. J Am Coll Cardiol 2009, 54:1165-1172.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 1165-1172
    • Venge, P.1    Johnston, N.2    Lindahl, B.3    James, S.4
  • 11
    • 0028952513 scopus 로고
    • Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using a human/mouse chimeric antibody to CEA as the tracer
    • Kuroki M., Matsumoto Y., Arakawa F., Haruno M., Murakami M., Kuwahara M., et al. Reducing interference from heterophilic antibodies in a two-site immunoassay for carcinoembryonic antigen (CEA) by using a human/mouse chimeric antibody to CEA as the tracer. J Immunol Methods 1995, 180:81-91.
    • (1995) J Immunol Methods , vol.180 , pp. 81-91
    • Kuroki, M.1    Matsumoto, Y.2    Arakawa, F.3    Haruno, M.4    Murakami, M.5    Kuwahara, M.6
  • 12
    • 85027925960 scopus 로고    scopus 로고
    • Rapid and sensitive cardiac troponin I immunoassay based on fluorescent europium(III)-chelated-dyed nanoparticles
    • Järvenpää M.-L., Kuningas K., Niemi I., Hedbeg P., Ristiniemi N., Pettersson K. Rapid and sensitive cardiac troponin I immunoassay based on fluorescent europium(III)-chelated-dyed nanoparticles. Clin Chim Acta 2012, 414:70-75.
    • (2012) Clin Chim Acta , vol.414 , pp. 70-75
    • Järvenpää, M.-L.1    Kuningas, K.2    Niemi, I.3    Hedbeg, P.4    Ristiniemi, N.5    Pettersson, K.6
  • 13
    • 0035102979 scopus 로고    scopus 로고
    • Europium nanoparticles and time-resolved fluorescence for ultrasensitive detection of prostate-specific antigen
    • Härmä H., Soukka T., Lövgren T. Europium nanoparticles and time-resolved fluorescence for ultrasensitive detection of prostate-specific antigen. Clin Chem 2001, 47:561-568.
    • (2001) Clin Chem , vol.47 , pp. 561-568
    • Härmä, H.1    Soukka, T.2    Lövgren, T.3
  • 14
    • 0002525538 scopus 로고
    • Synthesis of two biotin isothiocyanate derivatives
    • Universitat Autnóma de Barcelona, Sitges, Barcelona, Spain
    • Mukkala V.-M., Hänninen E., Hemmilä I. Synthesis of two biotin isothiocyanate derivatives. 8th European Symposium on Organic Chemistry 1993, 86. Universitat Autnóma de Barcelona, Sitges, Barcelona, Spain.
    • (1993) 8th European Symposium on Organic Chemistry , pp. 86
    • Mukkala, V.-M.1    Hänninen, E.2    Hemmilä, I.3
  • 15
    • 33751207128 scopus 로고    scopus 로고
    • Intact free prostate-specific antigen and free and total human glandular kallikrein 2. Elimination of assay interference by enzymatic digestion of antibodies to F(ab')2 fragments
    • Väisänen V., Peltola M.T., Lilja H., Nurmi M., Pettersson K. Intact free prostate-specific antigen and free and total human glandular kallikrein 2. Elimination of assay interference by enzymatic digestion of antibodies to F(ab')2 fragments. Anal Chem 2006, 78:7809-7815.
    • (2006) Anal Chem , vol.78 , pp. 7809-7815
    • Väisänen, V.1    Peltola, M.T.2    Lilja, H.3    Nurmi, M.4    Pettersson, K.5
  • 16
    • 0038610963 scopus 로고    scopus 로고
    • Negative interference in cardiac troponin I immunoassays from a frequently occurring serum and plasma component
    • Eriksson S., Junikka M., Laitinen P., Majamaa-Voltti K., Alfthan H., Pettersson K. Negative interference in cardiac troponin I immunoassays from a frequently occurring serum and plasma component. Clin Chem 2003, 49:1095-1104.
    • (2003) Clin Chem , vol.49 , pp. 1095-1104
    • Eriksson, S.1    Junikka, M.2    Laitinen, P.3    Majamaa-Voltti, K.4    Alfthan, H.5    Pettersson, K.6
  • 17
    • 19344373495 scopus 로고    scopus 로고
    • Sensitive adenovirus immunoassay as a model for using nanoparticle label technology in virus diagnostics
    • Valanne A., Huopalahti S., Soukka T., Vainionpää R., Lövgren T., Härmä H.A. Sensitive adenovirus immunoassay as a model for using nanoparticle label technology in virus diagnostics. J Clin Virol 2005, 33:217-223.
    • (2005) J Clin Virol , vol.33 , pp. 217-223
    • Valanne, A.1    Huopalahti, S.2    Soukka, T.3    Vainionpää, R.4    Lövgren, T.5    Härmä, H.A.6
  • 18
    • 0037334716 scopus 로고    scopus 로고
    • One-step quantitative thyrotropin assay for the detection of hypothyroidism in point-of-care conditions
    • von Lode P., Hagren V., Palenius T., Lövgren T. One-step quantitative thyrotropin assay for the detection of hypothyroidism in point-of-care conditions. Clin Biochem 2003, 36:121-128.
    • (2003) Clin Biochem , vol.36 , pp. 121-128
    • von Lode, P.1    Hagren, V.2    Palenius, T.3    Lövgren, T.4
  • 19
    • 17744395505 scopus 로고    scopus 로고
    • Comparison of cardiac troponin I immunoassays variably affected by circulating autoantibodies
    • Eriksson S., Ilva T., Becker C., Lund J., Porela P., Pulkki K., et al. Comparison of cardiac troponin I immunoassays variably affected by circulating autoantibodies. Clin Chem 2005, 51:848-855.
    • (2005) Clin Chem , vol.51 , pp. 848-855
    • Eriksson, S.1    Ilva, T.2    Becker, C.3    Lund, J.4    Porela, P.5    Pulkki, K.6
  • 20
    • 84861690510 scopus 로고    scopus 로고
    • Troponin-specific autoantibody interference in different cardiac troponin I assay configurations
    • Savukoski T., Engstrom E., Engblom J., Ristiniemi N., Wittfooth S., Lindahl B., et al. Troponin-specific autoantibody interference in different cardiac troponin I assay configurations. Clin Chem 2012, 58:1040-1048.
    • (2012) Clin Chem , vol.58 , pp. 1040-1048
    • Savukoski, T.1    Engstrom, E.2    Engblom, J.3    Ristiniemi, N.4    Wittfooth, S.5    Lindahl, B.6
  • 21
    • 0035872345 scopus 로고    scopus 로고
    • Utilization of kinetically enhanced monovalent binding affinity by immunoassays based on multivalent nanoparticle-antibody bioconjugates
    • Soukka T., Härmä H., Paukkunen J., Lövgren T. Utilization of kinetically enhanced monovalent binding affinity by immunoassays based on multivalent nanoparticle-antibody bioconjugates. Anal Chem 2001, 73:2254-2260.
    • (2001) Anal Chem , vol.73 , pp. 2254-2260
    • Soukka, T.1    Härmä, H.2    Paukkunen, J.3    Lövgren, T.4
  • 22
    • 84862585560 scopus 로고    scopus 로고
    • Long-term biological variation in cardiac troponin I
    • Wu A.H., Akhigbe P., Wians F. Long-term biological variation in cardiac troponin I. Clin Biochem 2012, 45:714-716.
    • (2012) Clin Biochem , vol.45 , pp. 714-716
    • Wu, A.H.1    Akhigbe, P.2    Wians, F.3
  • 23
    • 0032895820 scopus 로고    scopus 로고
    • False increases of troponin I attributable to incomplete separation of serum
    • Nosanchuk J.S., Combs B., Abbott G. False increases of troponin I attributable to incomplete separation of serum. Clin Chem 1999, 45:714.
    • (1999) Clin Chem , vol.45 , pp. 714
    • Nosanchuk, J.S.1    Combs, B.2    Abbott, G.3
  • 24
    • 0032742968 scopus 로고    scopus 로고
    • High percentage of false positive cardiac troponin I results in patients with rheumatoid factor
    • Krahn J., Parry D.M., Leroux M., Dalton J. High percentage of false positive cardiac troponin I results in patients with rheumatoid factor. Clin Biochem 1999, 32:477-480.
    • (1999) Clin Biochem , vol.32 , pp. 477-480
    • Krahn, J.1    Parry, D.M.2    Leroux, M.3    Dalton, J.4
  • 25
    • 0033248168 scopus 로고    scopus 로고
    • False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factors
    • Dasgupta A., Banerjee S.K., Datta P. False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factors. Am J Clin Pathol 1999, 112:753-756.
    • (1999) Am J Clin Pathol , vol.112 , pp. 753-756
    • Dasgupta, A.1    Banerjee, S.K.2    Datta, P.3
  • 26
    • 0024373953 scopus 로고
    • Interference of complement with the binding of carcinoembryonic antigen to solid-phase monoclonal antibodies
    • Börmer O.P. Interference of complement with the binding of carcinoembryonic antigen to solid-phase monoclonal antibodies. J Immunol Methods 1989, 121:85-93.
    • (1989) J Immunol Methods , vol.121 , pp. 85-93
    • Börmer, O.P.1
  • 27
    • 0034087032 scopus 로고    scopus 로고
    • Human anti-mouse antibodies
    • Klee G.G. Human anti-mouse antibodies. Arch Pathol Lab Med 2000, 124:921-923.
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 921-923
    • Klee, G.G.1
  • 28
    • 0141756310 scopus 로고    scopus 로고
    • Minimizing immunogenicity of the SDR-grafted humanized antibody CC49 by genetic manipulation of the framework residues
    • Gonzales N. Minimizing immunogenicity of the SDR-grafted humanized antibody CC49 by genetic manipulation of the framework residues. Mol Immunol 2003, 40:337-349.
    • (2003) Mol Immunol , vol.40 , pp. 337-349
    • Gonzales, N.1
  • 29
    • 17044431976 scopus 로고    scopus 로고
    • Use of an in vivo biotinylated single-chain antibody as capture reagent in an immunometric assay to decrease the incidence of interference from heterophilic antibodies
    • Warren D.J., Bjerner J., Paus E., Børmer O.P., Nustad K. Use of an in vivo biotinylated single-chain antibody as capture reagent in an immunometric assay to decrease the incidence of interference from heterophilic antibodies. Clin Chem 2005, 51:830-838.
    • (2005) Clin Chem , vol.51 , pp. 830-838
    • Warren, D.J.1    Bjerner, J.2    Paus, E.3    Børmer, O.P.4    Nustad, K.5
  • 30
    • 0028944024 scopus 로고
    • Comparative thermodynamic analyses of the Fv, Fab* and Fab fragments of anti-dansyl mouse monoclonal antibody
    • Shimba N., Torigoe H., Takahashi H., Masuda K., Shimada I., Arata Y., et al. Comparative thermodynamic analyses of the Fv, Fab* and Fab fragments of anti-dansyl mouse monoclonal antibody. FEBS Lett 1995, 360:247-250.
    • (1995) FEBS Lett , vol.360 , pp. 247-250
    • Shimba, N.1    Torigoe, H.2    Takahashi, H.3    Masuda, K.4    Shimada, I.5    Arata, Y.6
  • 31
    • 33845957062 scopus 로고    scopus 로고
    • Optimisation of production of a domoic acid-binding scFv antibody fragment in Escherichia coli using molecular chaperones and functional immobilisation on a mesoporous silicate support
    • Hu X., O'Hara L., White S., Magner E., Kane M., Wall J.G. Optimisation of production of a domoic acid-binding scFv antibody fragment in Escherichia coli using molecular chaperones and functional immobilisation on a mesoporous silicate support. Protein Expr Purif 2007, 52:194-201.
    • (2007) Protein Expr Purif , vol.52 , pp. 194-201
    • Hu, X.1    O'Hara, L.2    White, S.3    Magner, E.4    Kane, M.5    Wall, J.G.6
  • 32
    • 0034127730 scopus 로고    scopus 로고
    • Dual-label time-resolved immunofluorometric assay of free and total prostate-specific antigen based on recombinant Fab fragments
    • Eriksson S., Vehniäinen M., Jansen T., Meretoja V., Saviranta P., Pettersson K., et al. Dual-label time-resolved immunofluorometric assay of free and total prostate-specific antigen based on recombinant Fab fragments. Clin Chem 2000, 46:658-666.
    • (2000) Clin Chem , vol.46 , pp. 658-666
    • Eriksson, S.1    Vehniäinen, M.2    Jansen, T.3    Meretoja, V.4    Saviranta, P.5    Pettersson, K.6
  • 33
    • 0038697633 scopus 로고    scopus 로고
    • Clinical and analytical performance of the liaison cardiac troponin I assay in unstable coronary artery disease, and the impact of age on the definition of reference limits. A FRISC-II substudy
    • FRISC II Study Group
    • Venge P., Johnston P., Lagerqvist L., Wallentin L., Lindahl P., FRISC II Study Group Clinical and analytical performance of the liaison cardiac troponin I assay in unstable coronary artery disease, and the impact of age on the definition of reference limits. A FRISC-II substudy. Clin Chem 2003, 49:880-886.
    • (2003) Clin Chem , vol.49 , pp. 880-886
    • Venge, P.1    Johnston, P.2    Lagerqvist, L.3    Wallentin, L.4    Lindahl, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.