메뉴 건너뛰기




Volumn 68, Issue 1, 2013, Pages 62-73

Intravenous solid tip ECG lead placement in telemetry implanted dogs. Part 2: High quality telemetry signals yield high sensitivity to drug-induced changes.

Author keywords

Cardiovascular; Dogs; ECG; Preclinical; Surgical methods; Telemetry

Indexed keywords

MILRINONE; MOXIFLOXACIN; SOTALOL;

EID: 84880041507     PISSN: 10568719     EISSN: 1873488X     Source Type: Journal    
DOI: 10.1016/j.vascn.2013.04.006     Document Type: Article
Times cited : (16)

References (41)
  • 1
    • 80054860140 scopus 로고    scopus 로고
    • Evaluation of a novel ECG lead placement method in telemetered freely moving cynomolgus monkeys: Assessment of an intravascular biopotential lead
    • Authier S., Moon L.B., Stonerook M., Fournier S., Gervais J., Maghezzi S., et al. Evaluation of a novel ECG lead placement method in telemetered freely moving cynomolgus monkeys: Assessment of an intravascular biopotential lead. Journal of Pharmacological and Toxicological Methods 2011, 64:145-150.
    • (2011) Journal of Pharmacological and Toxicological Methods , vol.64 , pp. 145-150
    • Authier, S.1    Moon, L.B.2    Stonerook, M.3    Fournier, S.4    Gervais, J.5    Maghezzi, S.6
  • 2
    • 34548496499 scopus 로고    scopus 로고
    • A cardiovascular monitoring system in conscious cynomolgus monkeys for regulatory safety pharmacology. Part 2: Pharmacological validation
    • Authier S., Tanguay J.F., Gauvin D., Di Fruscia R., Fournier S. A cardiovascular monitoring system in conscious cynomolgus monkeys for regulatory safety pharmacology. Part 2: Pharmacological validation. Journal of Pharmacological and Toxicological Methods 2007, 56:122-130.
    • (2007) Journal of Pharmacological and Toxicological Methods , vol.56 , pp. 122-130
    • Authier, S.1    Tanguay, J.F.2    Gauvin, D.3    Di Fruscia, R.4    Fournier, S.5
  • 7
    • 0000678278 scopus 로고
    • The dog electrocardiogram: A critical review
    • Pergamon Press, New York, New York, (Ch. 35), P.W. MacFarlane, T.D.V. Lawrie (Eds.)
    • Detweiler D.K. The dog electrocardiogram: A critical review. Comprehensive electrocardiography: Theory and practice in health and disease 1989, Vol. 2:1267-1327. Pergamon Press, New York, New York, (Ch. 35). P.W. MacFarlane, T.D.V. Lawrie (Eds.).
    • (1989) Comprehensive electrocardiography: Theory and practice in health and disease , vol.2 , pp. 1267-1327
    • Detweiler, D.K.1
  • 8
    • 0002218902 scopus 로고    scopus 로고
    • Electrocardiography in toxicological studies
    • Elsevier Science Ltd., Oxford, United Kingdom, (Ch. 6.07), I.G. Sipes (Ed.)
    • Detweiler D.K. Electrocardiography in toxicological studies. Comprehensive toxicology 1997, Vol. 6:95-115. Elsevier Science Ltd., Oxford, United Kingdom, (Ch. 6.07). I.G. Sipes (Ed.).
    • (1997) Comprehensive toxicology , vol.6 , pp. 95-115
    • Detweiler, D.K.1
  • 10
    • 0009663357 scopus 로고
    • A multiple comparison procedure for comparing several treatments with a control
    • Dunnett C.W. A multiple comparison procedure for comparing several treatments with a control. Journal of American Statistics Association 1955, 50:1096-1121.
    • (1955) Journal of American Statistics Association , vol.50 , pp. 1096-1121
    • Dunnett, C.W.1
  • 11
    • 0000080398 scopus 로고
    • New tables for multiple comparisons with a control
    • Dunnett C.W. New tables for multiple comparisons with a control. Biometrics 1964, 20:482-491.
    • (1964) Biometrics , vol.20 , pp. 482-491
    • Dunnett, C.W.1
  • 12
    • 33644551239 scopus 로고    scopus 로고
    • Electrocardiogram, hemodynamics, and core body temperatures of the normal free moving laboratory beagle dog by remote radiotelemetry
    • Gauvin D.V., Tilley L.P., Smith F.W.K., Baird T.J. Electrocardiogram, hemodynamics, and core body temperatures of the normal free moving laboratory beagle dog by remote radiotelemetry. Journal of Pharmacological and Toxicological Methods 2006, 53:128-139.
    • (2006) Journal of Pharmacological and Toxicological Methods , vol.53 , pp. 128-139
    • Gauvin, D.V.1    Tilley, L.P.2    Smith, F.W.K.3    Baird, T.J.4
  • 13
    • 33644534168 scopus 로고    scopus 로고
    • Electrocardiogram, hemodynamics, and core body temperatures of the normal free moving cynomolgus monkey by remote radiotelemetry
    • Gauvin D.V., Tilley L.P., Smith F.W.K., Baird T.J. Electrocardiogram, hemodynamics, and core body temperatures of the normal free moving cynomolgus monkey by remote radiotelemetry. Journal of Pharmacological and Toxicological Methods 2006, 53:140-151.
    • (2006) Journal of Pharmacological and Toxicological Methods , vol.53 , pp. 140-151
    • Gauvin, D.V.1    Tilley, L.P.2    Smith, F.W.K.3    Baird, T.J.4
  • 15
    • 44449143331 scopus 로고    scopus 로고
    • How many leads are required for in vivo studies in safety pharmacology?
    • Hamlin R.L. How many leads are required for in vivo studies in safety pharmacology?. Journal of Pharmacological and Toxicological Methods 2008, 57:161-168.
    • (2008) Journal of Pharmacological and Toxicological Methods , vol.57 , pp. 161-168
    • Hamlin, R.L.1
  • 17
    • 10444249565 scopus 로고    scopus 로고
    • Effect of milrinone on echocardiographic parameters after single dose in beagle dogs and relationship with drug-induced cardiotoxicity
    • Hanton G., Gautier M., Bonnet P., Herbet A. Effect of milrinone on echocardiographic parameters after single dose in beagle dogs and relationship with drug-induced cardiotoxicity. Toxicology Letters 2005, 155(2):307-317.
    • (2005) Toxicology Letters , vol.155 , Issue.2 , pp. 307-317
    • Hanton, G.1    Gautier, M.2    Bonnet, P.3    Herbet, A.4
  • 18
    • 0030122090 scopus 로고    scopus 로고
    • Noninvasive versus invasive blood pressure measurement in normotensive and hypertensive baboons
    • Hartford C.G., Marcos E.F., Rogers G.C. Noninvasive versus invasive blood pressure measurement in normotensive and hypertensive baboons. Laboratory Animal Science 1996, 46:231-233.
    • (1996) Laboratory Animal Science , vol.46 , pp. 231-233
    • Hartford, C.G.1    Marcos, E.F.2    Rogers, G.C.3
  • 23
    • 13144251108 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals. Part 2: Blood pressure measurement in experimental animals: A statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on High Blood Pressure Research
    • Kurtz T.W., Grifflin K.A., Bidani A.K., Davisson R.L., Hall J.E. Recommendations for blood pressure measurement in humans and experimental animals. Part 2: Blood pressure measurement in experimental animals: A statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on High Blood Pressure Research. Hypertension 2005, 45:299-310.
    • (2005) Hypertension , vol.45 , pp. 299-310
    • Kurtz, T.W.1    Grifflin, K.A.2    Bidani, A.K.3    Davisson, R.L.4    Hall, J.E.5
  • 24
    • 84861481556 scopus 로고    scopus 로고
    • Best practice in the conduct of key nonclinical cardiovascular assessments in drug development: Current recommendations from the Safety Pharmacology Society
    • Leishman D.J., Beck T.W., Dybdal N., Gallacher D.J., Guth B.D., Holbrook M., et al. Best practice in the conduct of key nonclinical cardiovascular assessments in drug development: Current recommendations from the Safety Pharmacology Society. Journal of Pharmacological and Toxicological Methods 2012, 65:93-101.
    • (2012) Journal of Pharmacological and Toxicological Methods , vol.65 , pp. 93-101
    • Leishman, D.J.1    Beck, T.W.2    Dybdal, N.3    Gallacher, D.J.4    Guth, B.D.5    Holbrook, M.6
  • 32
    • 84894897508 scopus 로고    scopus 로고
    • Telemetric intracardiac ECG dramatically improve internal detection and reduces artifact when compared to a subcutaneous lead placement in freely moving dogs
    • Singer D., Stonerook M., Vinci T., Hassler C., Vadnal A. Telemetric intracardiac ECG dramatically improve internal detection and reduces artifact when compared to a subcutaneous lead placement in freely moving dogs. The FASEB Journal 2006, 20:A232.
    • (2006) The FASEB Journal , vol.20
    • Singer, D.1    Stonerook, M.2    Vinci, T.3    Hassler, C.4    Vadnal, A.5
  • 35
    • 0031739615 scopus 로고    scopus 로고
    • The heart rate-corrected QT interval of conscious beagle dogs: A formula based on analysis of covariance
    • Spence S., Soper K., Hoe C.-M., Coleman J. The heart rate-corrected QT interval of conscious beagle dogs: A formula based on analysis of covariance. Toxicological Sciences 1998, 45:247-258.
    • (1998) Toxicological Sciences , vol.45 , pp. 247-258
    • Spence, S.1    Soper, K.2    Hoe, C.-M.3    Coleman, J.4
  • 37
    • 0034049380 scopus 로고    scopus 로고
    • Statistical issues in large animal toxicology
    • Thakur A.K. Statistical issues in large animal toxicology. International Journal of Toxicology 2000, 19:133-140.
    • (2000) International Journal of Toxicology , vol.19 , pp. 133-140
    • Thakur, A.K.1
  • 38
    • 77957982519 scopus 로고    scopus 로고
    • Electrocardiography
    • Saunders Elsevier, St. Louis, Missouri, (Ch. 3), L.P. Tilley (Ed.)
    • Tilley L.P., Smith F.W.K. Electrocardiography. Manual of canine and feline cardiology 2008, 49-77. Saunders Elsevier, St. Louis, Missouri, (Ch. 3). 4th ed. L.P. Tilley (Ed.).
    • (2008) Manual of canine and feline cardiology , pp. 49-77
    • Tilley, L.P.1    Smith, F.W.K.2
  • 39
    • 0001853003 scopus 로고
    • Single-factor experiments having repeated measures on the same elements
    • McGraw-Hill, New York, New York, (Ch. 4)
    • Winer B.J., Brown D.R., Michels K.M. Single-factor experiments having repeated measures on the same elements. Statistical principles in experimental design 1991, 220-281. McGraw-Hill, New York, New York, (Ch. 4). 3rd ed.
    • (1991) Statistical principles in experimental design , pp. 220-281
    • Winer, B.J.1    Brown, D.R.2    Michels, K.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.