메뉴 건너뛰기




Volumn 24, Issue 7, 2013, Pages 1707-1715

Osteoconduction of porous Ti metal enhanced by acid and heat treatments

Author keywords

[No Author keywords available]

Indexed keywords

ACID TREATMENTS; BONE INGROWTH; CHEMICAL-AND-HEAT TREATMENT; CRYSTALLINE PHASE; METAL IMPLANTS; OSTEOCONDUCTION; OUTER SURFACE; POSITIVE SURFACE CHARGE;

EID: 84879797944     PISSN: 09574530     EISSN: 15734838     Source Type: Journal    
DOI: 10.1007/s10856-013-4919-0     Document Type: Article
Times cited : (28)

References (26)
  • 1
    • 0346095342 scopus 로고    scopus 로고
    • Porous Ti-6Al-4 v alloy fabricated by spark plasma sintering for biomimetic surface modification
    • 10.1002/jbm.b.20004
    • Kon M, Hirakata LM, Asaoka K. Porous Ti-6Al-4 V alloy fabricated by spark plasma sintering for biomimetic surface modification. J Biomed Mater Res B. 2004;68:88.
    • (2004) J Biomed Mater Res B , vol.68 , pp. 88
    • Kon, M.1    Hirakata, L.M.2    Asaoka, K.3
  • 2
    • 2942534210 scopus 로고    scopus 로고
    • Mechanics considerations for microporous titanium as an orthopedic implant material
    • 10.1002/jbm.a.20100
    • Thelen S, Barthelat F, Brinson LC. Mechanics considerations for microporous titanium as an orthopedic implant material. J Biomed Mater Res A. 2004;69:601.
    • (2004) J Biomed Mater Res A , vol.69 , pp. 601
    • Thelen, S.1    Barthelat, F.2    Brinson, L.C.3
  • 3
    • 0142133589 scopus 로고    scopus 로고
    • Porous titanium-nickel for intervertebral fusion in a sheep model: Part 1. Histomorphometric and radiological analysis
    • 10.1002/jbm.b.10530
    • Assad M, Jarzem P, Leroux MA, Coillard C, Chernyshov AV, Charette S, Rivard CH. Porous titanium-nickel for intervertebral fusion in a sheep model: part 1. Histomorphometric and radiological analysis. J Biomed Mater Res B. 2003;64:107.
    • (2003) J Biomed Mater Res B , vol.64 , pp. 107
    • Assad, M.1    Jarzem, P.2    Leroux, M.A.3    Coillard, C.4    Chernyshov, A.V.5    Charette, S.6    Rivard, C.H.7
  • 4
    • 0036203642 scopus 로고    scopus 로고
    • Processing and mechanical properties of autogenous titanium implant materials
    • 10.1023/A:1014344819558 1:CAS:528:DC%2BD38Xjt1aksr4%3D
    • Wen CE, Yamada Y, Shimojima K, Chino Y, Asahina T, Mabuchi M. Processing and mechanical properties of autogenous titanium implant materials. J Mater Sci Mater Med. 2002;13:397.
    • (2002) J Mater Sci Mater Med , vol.13 , pp. 397
    • Wen, C.E.1    Yamada, Y.2    Shimojima, K.3    Chino, Y.4    Asahina, T.5    Mabuchi, M.6
  • 5
    • 0035086460 scopus 로고    scopus 로고
    • Structure, metallurgy, and mechanical properties of a porous tantalum foam
    • 10.1002/1097-4636(2001)58:2<180: AID-JBM1005>3.0.CO;2-5 1:CAS:528:DC%2BD3MXitlWjtbY%3D
    • Zardiackas LD, Parsell DE, Dillon LD, Mitchell DW, Nunnery LA, Poggie R. Structure, metallurgy, and mechanical properties of a porous tantalum foam. J Biomed Mater Res. 2001;58:180.
    • (2001) J Biomed Mater Res , vol.58 , pp. 180
    • Zardiackas, L.D.1    Parsell, D.E.2    Dillon, L.D.3    Mitchell, D.W.4    Nunnery, L.A.5    Poggie, R.6
  • 6
    • 67651100727 scopus 로고    scopus 로고
    • Effects of oxygen content of porous titanium metal on its apatite-forming ability and compressive strength
    • 10.1016/j.msec.2009.03.014 1:CAS:528:DC%2BD1MXoslCru74%3D
    • Pattanayak DK, Matsushita T, Doi K, Takadama H, Nakamura T, Kokubo T. Effects of oxygen content of porous titanium metal on its apatite-forming ability and compressive strength. Mater Sci Eng C. 2009;29:1974.
    • (2009) Mater Sci Eng C , vol.29 , pp. 1974
    • Pattanayak, D.K.1    Matsushita, T.2    Doi, K.3    Takadama, H.4    Nakamura, T.5    Kokubo, T.6
  • 7
    • 79251639042 scopus 로고    scopus 로고
    • Bioactive Ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments
    • 10.1016/j.actbio.2010.09.034 England: 2010 Acta Materialia Inc. published by Elsevier Ltd
    • Pattanayak DK, Fukuda A, Matsushita T, Takemoto M, Fujibayashi S, Sasaki K, Nishida N, Nakamura T, Kokubo T. Bioactive Ti metal analogous to human cancellous bone: fabrication by selective laser melting and chemical treatments. Acta Biomater. 2010;7:1398-406. England: 2010 Acta Materialia Inc. published by Elsevier Ltd.
    • (2010) Acta Biomater , vol.7 , pp. 1398-1406
    • Pattanayak, D.K.1    Fukuda, A.2    Matsushita, T.3    Takemoto, M.4    Fujibayashi, S.5    Sasaki, K.6    Nishida, N.7    Nakamura, T.8    Kokubo, T.9
  • 9
    • 20444476825 scopus 로고    scopus 로고
    • Mechanical properties and osteoconductivity of porous bioactive titanium
    • 10.1016/j.biomaterials.2005.03.019 1:CAS:528:DC%2BD2MXlt1Wgsbc%3D
    • Takemoto M, Fujibayashi S, Neo M, Suzuki J, Kokubo T, Nakamura T. Mechanical properties and osteoconductivity of porous bioactive titanium. Biomaterials. 2005;26:6014.
    • (2005) Biomaterials , vol.26 , pp. 6014
    • Takemoto, M.1    Fujibayashi, S.2    Neo, M.3    Suzuki, J.4    Kokubo, T.5    Nakamura, T.6
  • 10
    • 78650704396 scopus 로고    scopus 로고
    • Variation of roughness and adhesion strength of deposited apatite layers on titanium dental implants
    • 10.1016/j.msec.2010.09.018 1:CAS:528:DC%2BC3cXhs1WmtbbF
    • Aparicio C, Rodriguez D, Gil FJ. Variation of roughness and adhesion strength of deposited apatite layers on titanium dental implants. Mater Sci Eng C. 2011;31:320.
    • (2011) Mater Sci Eng C , vol.31 , pp. 320
    • Aparicio, C.1    Rodriguez, D.2    Gil, F.J.3
  • 11
    • 31144435936 scopus 로고    scopus 로고
    • Osteoinductive porous titanium implants: Effect of sodium removal by dilute HCl treatmen
    • 10.1016/j.biomaterials.2005.12.014 1:CAS:528:DC%2BD28XnvVWkuw%3D%3D England
    • Takemoto M, Fujibayashi S, Neo M, Suzuki J, Matsushita T, Kokubo T, Nakamura T. Osteoinductive porous titanium implants: effect of sodium removal by dilute HCl treatmen. Biomaterials. 2006;27:2682-91. England.
    • (2006) Biomaterials , vol.27 , pp. 2682-2691
    • Takemoto, M.1    Fujibayashi, S.2    Neo, M.3    Suzuki, J.4    Matsushita, T.5    Kokubo, T.6    Nakamura, T.7
  • 12
    • 84855190857 scopus 로고    scopus 로고
    • A novel synthetic material for spinal fusion: A prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion
    • 10.1007/s00586-011-1728-3
    • Fujibayashi S, Takemoto M, Neo M, Matsushita T, Kokubo T, Doi K, Ito T, Shimizu A, Nakamura T. A novel synthetic material for spinal fusion: a prospective clinical trial of porous bioactive titanium metal for lumbar interbody fusion. Eur Spine J. 2011;20:1486.
    • (2011) Eur Spine J , vol.20 , pp. 1486
    • Fujibayashi, S.1    Takemoto, M.2    Neo, M.3    Matsushita, T.4    Kokubo, T.5    Doi, K.6    Ito, T.7    Shimizu, A.8    Nakamura, T.9
  • 14
    • 84866148831 scopus 로고    scopus 로고
    • Apatite-forming ability of titanium in terms of pH of the exposed solution
    • 10.1098/rsif.2012.0107 1:CAS:528:DC%2BC38XhtlGhu7%2FF
    • Pattanayak DK, Yamaguchi S, Matsushita T, Nakamura T, Kokubo T. Apatite-forming ability of titanium in terms of pH of the exposed solution. J R Soc Interface. 2012;9:2145.
    • (2012) J R Soc Interface , vol.9 , pp. 2145
    • Pattanayak, D.K.1    Yamaguchi, S.2    Matsushita, T.3    Nakamura, T.4    Kokubo, T.5
  • 15
    • 73449083031 scopus 로고    scopus 로고
    • Effect of HCl concentrations on apatite-forming ability of NaOH-HCl- and heat-treated titanium metal
    • 10.1007/s10856-009-3815-0 1:CAS:528:DC%2BD1MXhsFChs7jL
    • Pattanayak DK, Kawai T, Matsushita T, Takadama H, Nakamura T, Kokubo T. Effect of HCl concentrations on apatite-forming ability of NaOH-HCl- and heat-treated titanium metal. J Mater Sci Mater Med. 2009;20:2401.
    • (2009) J Mater Sci Mater Med , vol.20 , pp. 2401
    • Pattanayak, D.K.1    Kawai, T.2    Matsushita, T.3    Takadama, H.4    Nakamura, T.5    Kokubo, T.6
  • 18
    • 33748301939 scopus 로고    scopus 로고
    • Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: Three-dimensional micro-CT based structural analyses of porous bioactive titanium implants
    • 10.1016/j.biomaterials.2006.08.013 1:CAS:528:DC%2BD28Xpt1yjsbc%3D
    • Otsuki B, Takemoto M, Fujibayashi S, Neo M, Kokubo T, Nakamura T. Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants. Biomaterials. 2006;27:5892.
    • (2006) Biomaterials , vol.27 , pp. 5892
    • Otsuki, B.1    Takemoto, M.2    Fujibayashi, S.3    Neo, M.4    Kokubo, T.5    Nakamura, T.6
  • 19
    • 0025449531 scopus 로고
    • Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W
    • 10.1002/jbm.820240607 1:CAS:528:DyaK3cXltlyntLk%3D
    • Kokubo T, Kushitani H, Sakka S, Kitsugi T, Yamamuro T. Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W. J Biomed Mater Res. 1990;24:721.
    • (1990) J Biomed Mater Res , vol.24 , pp. 721
    • Kokubo, T.1    Kushitani, H.2    Sakka, S.3    Kitsugi, T.4    Yamamuro, T.5
  • 20
    • 32144437418 scopus 로고    scopus 로고
    • How useful is SBF in predicting in vivo bone bioactivity?
    • 10.1016/j.biomaterials.2006.01.017 1:CAS:528:DC%2BD28Xht1Crt7o%3D
    • Kokubo T, Takadama H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials. 2006;27:2907.
    • (2006) Biomaterials , vol.27 , pp. 2907
    • Kokubo, T.1    Takadama, H.2
  • 21
    • 0037376892 scopus 로고    scopus 로고
    • A comparative study between in vivo bone ingrowth and in vitro apatite formation on Na2O-CaO-SiO2 glasses
    • 10.1016/S0142-9612(02)00511-2 1:CAS:528:DC%2BD3sXis1Shuw%3D%3D
    • Fujibayashi S, Neo M, Kim HM, Kokubo T, Nakamura T. A comparative study between in vivo bone ingrowth and in vitro apatite formation on Na2O-CaO-SiO2 glasses. Biomaterials. 2003;24:1349.
    • (2003) Biomaterials , vol.24 , pp. 1349
    • Fujibayashi, S.1    Neo, M.2    Kim, H.M.3    Kokubo, T.4    Nakamura, T.5
  • 22
    • 0030298049 scopus 로고    scopus 로고
    • Preparation of bioactive Ti and its alloys via simple chemical surface treatment
    • 10.1002/(SICI)1097-4636(199611)32:3<409: AID-JBM14>3.0.CO;2-B 1:CAS:528:DyaK28XmtlCit74%3D
    • Kim HM, Miyaji F, Kokubo T, Nakamura T. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res. 1996;32:409.
    • (1996) J Biomed Mater Res , vol.32 , pp. 409
    • Kim, H.M.1    Miyaji, F.2    Kokubo, T.3    Nakamura, T.4
  • 23
    • 0031281415 scopus 로고    scopus 로고
    • Bonding of chemically treated titanium implants to bone
    • 10.1002/(SICI)1097-4636(199711)37:2<267: AID-JBM17>3.0.CO;2-B 1:CAS:528:DyaK2sXntVartbY%3D
    • Yan WQ, Nakamura T, Kobayashi M, Kim HM, Miyaji F, Kokubo T. Bonding of chemically treated titanium implants to bone. J Biomed Mater Res. 1997;37:267.
    • (1997) J Biomed Mater Res , vol.37 , pp. 267
    • Yan, W.Q.1    Nakamura, T.2    Kobayashi, M.3    Kim, H.M.4    Miyaji, F.5    Kokubo, T.6
  • 26
    • 81255171432 scopus 로고    scopus 로고
    • In vivo evaluation of micro-rough and bioactive titanium dental implants using histometry and pull-out tests
    • 10.1016/j.jmbbm.2011.05.005 1:CAS:528:DC%2BC38XhsVKks7Y%3D Netherlands: 2011 Elsevier Ltd
    • Aparicio C, Padros A, Gil FJ. In vivo evaluation of micro-rough and bioactive titanium dental implants using histometry and pull-out tests. J Mech Behav Biomed Mater. 2011;4:1672. Netherlands: 2011 Elsevier Ltd.
    • (2011) J Mech Behav Biomed Mater , vol.4 , pp. 1672
    • Aparicio, C.1    Padros, A.2    Gil, F.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.