메뉴 건너뛰기




Volumn 101, Issue 4, 2013, Pages 591-598

Coating of carbon fiber-reinforced polyetheretherketone implants with titanium to improve bone apposition

Author keywords

Coating; In vivo; Orthopedic; PEEK; Titanium

Indexed keywords

HYDROPHOBIC SURFACES; IN-VIVO; IRREGULAR SURFACE; MICROSCOPY TECHNIQUE; ORTHOPEDIC IMPLANT; STATISTICAL DIFFERENCES; THERMOPLASTIC COMPOSITE; VACUUM PLASMA SPRAYING;

EID: 84879606418     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.32861     Document Type: Article
Times cited : (94)

References (25)
  • 2
    • 33751337411 scopus 로고    scopus 로고
    • Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone
    • DOI 10.1016/j.biomaterials.2006.10.031, PII S0142961206009446
    • Converse GL, Yue W, Roeder RK. Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone. Biomaterials 2007;28:927-935. (Pubitemid 44809434)
    • (2007) Biomaterials , vol.28 , Issue.6 , pp. 927-935
    • Converse, G.L.1    Yue, W.2    Roeder, R.K.3
  • 3
    • 77249117286 scopus 로고    scopus 로고
    • The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties
    • Han C-M, Lee EJ, Kim H-E, Koh Y-H, Kim KN, Ha Y, Kuh S-U. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties. Biomaterials 2010;31:3465-3470.
    • (2010) Biomaterials , vol.31 , pp. 3465-3470
    • Han, C.-M.1    Lee, E.J.2    Kim, H.-E.3    Koh, Y.-H.4    Kim, K.N.5    Ha, Y.6    Kuh, S.-U.7
  • 5
    • 78650250304 scopus 로고    scopus 로고
    • Autohesion of plasma treated semicrystalline PEEK: Comparative study of argon, nitrogen and oxygen treatments
    • Zhang S, Awaja F, James N, McKenzie DR, Ruys AJ. Autohesion of plasma treated semicrystalline PEEK: Comparative study of argon, nitrogen and oxygen treatments. Colloids Surf A: Physicochem Eng Aspects 2011;374:88-95.
    • (2011) Colloids Surf A: Physicochem Eng Aspects , vol.374 , pp. 88-95
    • Zhang, S.1    Awaja, F.2    James, N.3    McKenzie, D.R.4    Ruys, A.J.5
  • 6
    • 84861102165 scopus 로고    scopus 로고
    • The improvement of adhesive properties of PEEK through different pre-treatments
    • Hallmann L, Mehl A, Sereno N, Hammerle CHF. The improvement of adhesive properties of PEEK through different pre-treatments. Appl Surf Sci 2012;258:7213-7218.
    • (2012) Appl Surf Sci , vol.258 , pp. 7213-7218
    • Hallmann, L.1    Mehl, A.2    Sereno, N.3    Hammerle, C.H.F.4
  • 7
    • 34548021405 scopus 로고    scopus 로고
    • PEEK biomaterials in trauma, orthopedic, and spinal implants
    • DOI 10.1016/j.biomaterials.2007.07.013, PII S0142961207005467
    • Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopaedic, and spinal implants. Biomaterials 2007;28:4845-4869. (Pubitemid 47285335)
    • (2007) Biomaterials , vol.28 , Issue.32 , pp. 4845-4869
    • Kurtz, S.M.1    Devine, J.N.2
  • 8
    • 0342972965 scopus 로고    scopus 로고
    • Nonresorbable polymers in bone surgery
    • Eschbach L. Nonresorbable polymers in bone surgery. Injury Int J Care Injured 2000;31:S-D22-27.
    • (2000) Injury Int J Care Injured , vol.31
    • Eschbach, L.1
  • 9
    • 0035397504 scopus 로고    scopus 로고
    • Biomedical applications of polymer-composite materials: A review
    • DOI 10.1016/S0266-3538(00)00241-4, PII S0266353800002414
    • Ramakrishna S, Mayer J, Wintermantel E, Leong KW. Biomedical applications of polymer-composite materials: A review. Compos Sci Technol 2001;61:1189-1224. (Pubitemid 32657276)
    • (2001) Composites Science and Technology , vol.61 , Issue.9 , pp. 1189-1224
    • Ramakrishna, S.1    Mayer, J.2    Wintermantel, E.3    Leong, K.W.4
  • 12
    • 0037629667 scopus 로고    scopus 로고
    • Thermal spray coatings on titanium
    • Brunette DM, Tengvall P, Thomsen P, Textor M, editors. Berlin, Heidelberg: Springer-Verlag
    • Gruner H. Thermal spray coatings on titanium. In: Brunette DM, Tengvall P, Thomsen P, Textor M, editors. Titanium in Medicine. Berlin, Heidelberg: Springer-Verlag; 2001. p375-416.
    • (2001) Titanium in Medicine. , pp. 375-416
    • Gruner, H.1
  • 15
    • 77249098664 scopus 로고    scopus 로고
    • Comparison of mesenchymal stem cells from bone marrow and adipose tissue for bone regeneration in a critical size defect of the sheep tibia and the influence of platelet-rich plasma
    • Niemeyer P, Fechner K, Milz S, Richter W, Suedkamp NP, Mehlhorn AT, Pearce S, Kasten K. Comparison of mesenchymal stem cells from bone marrow and adipose tissue for bone regeneration in a critical size defect of the sheep tibia and the influence of platelet-rich plasma. Biomaterials 2010;31:3572-3579.
    • (2010) Biomaterials , vol.31 , pp. 3572-3579
    • Niemeyer, P.1    Fechner, K.2    Milz, S.3    Richter, W.4    Suedkamp, N.P.5    Mehlhorn, A.T.6    Pearce, S.7    Kasten, K.8
  • 16
    • 53549128389 scopus 로고    scopus 로고
    • Richards RG.Effect of surface topography on removal of cortical bone screws in a novel sheep model
    • Pearce AI, Pearce SG, Schwieger K, Milz S, Schneider E, Archer CW, Richards RG.Effect of surface topography on removal of cortical bone screws in a novel sheep model. J Orthop Res 2008;26: 1377-1383.
    • (2008) J Orthop Res , vol.26 , pp. 1377-1383
    • Pearce, A.I.1    Pearce, S.G.2    Schwieger, K.3    Milz, S.4    Schneider, E.5    Archer, C.W.6
  • 17
    • 77449124489 scopus 로고    scopus 로고
    • Surfaces to control tissue adhesion for osteosynthesis with metal implants: In vitro and in vivo studies to bring solutions to the patient
    • Hayes JS, Richards RG. Surfaces to control tissue adhesion for osteosynthesis with metal implants: In vitro and in vivo studies to bring solutions to the patient. Expert Rev Med Devices 2010;7: 131-142.
    • (2010) Expert Rev Med Devices , vol.7 , pp. 131-142
    • Hayes, J.S.1    Richards, R.G.2
  • 18
    • 84860430585 scopus 로고    scopus 로고
    • Osteointegrative surfaces for CF/PEEK implants
    • Gisep A, Wieling R. Osteointegrative surfaces for CF/PEEK implants. Eur Cell Mater 2009;17:10.
    • (2009) Eur Cell Mater , vol.17 , pp. 10
    • Gisep, A.1    Wieling, R.2
  • 20
    • 77957123653 scopus 로고    scopus 로고
    • The role of surface microtopography in the modulation of osteoblast differentiation
    • Hayes JS, Kahn IM, Archer CW, Richards RG. The role of surface microtopography in the modulation of osteoblast differentiation. Eur Cell Mater 2010;20:98-108.
    • (2010) Eur Cell Mater , vol.20 , pp. 98-108
    • Hayes, J.S.1    Kahn, I.M.2    Archer, C.W.3    Richards, R.G.4
  • 24
    • 78149368398 scopus 로고    scopus 로고
    • The use of titanium and stainless steel in fracture fixation (review)
    • Hayes JS, Richards RG. The use of titanium and stainless steel in fracture fixation (review). Expert Rev Med Devices 2010;7:843-853.
    • (2010) Expert Rev Med Devices , vol.7 , pp. 843-853
    • Hayes, J.S.1    Richards, R.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.