-
1
-
-
0033846089
-
Optimization of CT colonography technique: Prospective trial in 180 patients
-
J.G. Fletcher, C.D. Johnson, and T.J. Welch Optimization of CT colonography technique: prospective trial in 180 patients Radiology 216 3 2000 704 711
-
(2000)
Radiology
, vol.216
, Issue.3
, pp. 704-711
-
-
Fletcher, J.G.1
Johnson, C.D.2
Welch, T.J.3
-
3
-
-
35348866146
-
Vasovagal reactions in CT colonography
-
E. Neri, D. Caramella, and F. Vannozzi Vasovagal reactions in CT colonography Abdom Imaging 32 5 2007 552 555
-
(2007)
Abdom Imaging
, vol.32
, Issue.5
, pp. 552-555
-
-
Neri, E.1
Caramella, D.2
Vannozzi, F.3
-
4
-
-
33646150672
-
Colonic Perforation at CT Colonography: Assessment of risk in a multicenter large cohort
-
J. Sosna, A. Blachar, and M. Amitai Colonic Perforation at CT Colonography: assessment of risk in a multicenter large cohort Radiology 239 2 2006 457 463
-
(2006)
Radiology
, vol.239
, Issue.2
, pp. 457-463
-
-
Sosna, J.1
Blachar, A.2
Amitai, M.3
-
5
-
-
0035458341
-
Patient experience and preferences toward colon cancer screening: A comparison of virtual colonoscopy and conventional colonoscopy
-
G.A. Akerkar, J. Yee, and R. Hung Patient experience and preferences toward colon cancer screening: a comparison of virtual colonoscopy and conventional colonoscopy Gastrointest Endosc 54 3 2001 310 315
-
(2001)
Gastrointest Endosc
, vol.54
, Issue.3
, pp. 310-315
-
-
Akerkar, G.A.1
Yee, J.2
Hung, R.3
-
6
-
-
33645756096
-
Effective radiation doses in CT colonography: Results of an inventory among research institutions
-
S. Jensch, R.E. van Gelder, and H.W. Venema Effective radiation doses in CT colonography: results of an inventory among research institutions Eur Radiol 16 5 2006 981 987
-
(2006)
Eur Radiol
, vol.16
, Issue.5
, pp. 981-987
-
-
Jensch, S.1
Van Gelder, R.E.2
Venema, H.W.3
-
7
-
-
52049112304
-
Radiation dose in CT colonography - Trends in time and differences between daily practice and screening protocols
-
M.H. Liedenbaum, H.W. Venema, and J. Stoker Radiation dose in CT colonography - trends in time and differences between daily practice and screening protocols Eur Radiol 18 10 2008 2222 2230
-
(2008)
Eur Radiol
, vol.18
, Issue.10
, pp. 2222-2230
-
-
Liedenbaum, M.H.1
Venema, H.W.2
Stoker, J.3
-
8
-
-
33646147154
-
Potentially serious adverse events at CT colonography in symptomatic patients: National survey of the United Kingdom
-
D. Burling, S. Halligan, and A. Slater Potentially serious adverse events at CT colonography in symptomatic patients: national survey of the United Kingdom Radiology 239 2 2006 464 471
-
(2006)
Radiology
, vol.239
, Issue.2
, pp. 464-471
-
-
Burling, D.1
Halligan, S.2
Slater, A.3
-
9
-
-
33846457874
-
European Society of Gastrointestinal and Abdominal Radiology (ESGAR): Consensus statement on CT colonography
-
S.A. Taylor, A. Laghi, and P. Lefere European Society of Gastrointestinal and Abdominal Radiology (ESGAR): consensus statement on CT colonography Eur Radiol 17 2 2007 575 579
-
(2007)
Eur Radiol
, vol.17
, Issue.2
, pp. 575-579
-
-
Taylor, S.A.1
Laghi, A.2
Lefere, P.3
-
10
-
-
77951666234
-
CT colonography standards
-
D. Burling CT colonography standards Clin Radiol 65 6 2010 474 480
-
(2010)
Clin Radiol
, vol.65
, Issue.6
, pp. 474-480
-
-
Burling, D.1
-
11
-
-
0141518442
-
Optimizing colonic distention for multi-detector row CT colonography: Effect of hyoscine butylbromide and rectal balloon catheter
-
S.A. Taylor, S. Halligan, and V. Goh Optimizing colonic distention for multi-detector row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter Radiology 229 1 2003 99 108
-
(2003)
Radiology
, vol.229
, Issue.1
, pp. 99-108
-
-
Taylor, S.A.1
Halligan, S.2
Goh, V.3
-
12
-
-
0036676907
-
Minimizing postcolonoscopy abdominal pain by using CO(2) insufflation: A prospective, randomized, double blind, controlled trial evaluating a new commercially available CO(2) delivery system
-
K. Sumanac, I. Zealley, and B.M. Fox Minimizing postcolonoscopy abdominal pain by using CO(2) insufflation: a prospective, randomized, double blind, controlled trial evaluating a new commercially available CO(2) delivery system Gastrointest Endosc 56 2 2002 190 194
-
(2002)
Gastrointest Endosc
, vol.56
, Issue.2
, pp. 190-194
-
-
Sumanac, K.1
Zealley, I.2
Fox, B.M.3
-
13
-
-
68849116179
-
CO2 insufflation during colonoscopy decreases post-interventional pain in deeply sedated patients: A randomized controlled trial
-
S. Riss, B. Akan, and B. Mikola CO2 insufflation during colonoscopy decreases post-interventional pain in deeply sedated patients: a randomized controlled trial Wien Klin Wochenschr 121 13-14 2009 464 468
-
(2009)
Wien Klin Wochenschr
, vol.121
, Issue.1314
, pp. 464-468
-
-
Riss, S.1
Akan, B.2
Mikola, B.3
-
14
-
-
0025737662
-
Use of air in double contrast barium enema - Is it still acceptable?
-
P.N. Taylor, and D.E. Beckly Use of air in double contrast barium enema - is it still acceptable? Clin Radiol 44 3 1991 183 184
-
(1991)
Clin Radiol
, vol.44
, Issue.3
, pp. 183-184
-
-
Taylor, P.N.1
Beckly, D.E.2
-
15
-
-
53549126608
-
Towards painless colonoscopy: A randomized controlled trial on carbon dioxide-insufflating colonoscopy
-
J.C.H. Wong, K.K. Yau, and H.Y.S. Cheung Towards painless colonoscopy: a randomized controlled trial on carbon dioxide-insufflating colonoscopy ANZ J Surg 78 10 2008 871 874
-
(2008)
ANZ J Surg
, vol.78
, Issue.10
, pp. 871-874
-
-
Wong, J.C.H.1
Yau, K.K.2
Cheung, H.Y.S.3
-
16
-
-
33745493238
-
Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography
-
T.J. Shinners, P.J. Pickhardt, and A.J. Taylor Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography AJR Am J Roentgenol 186 6 2006 1491 1496
-
(2006)
AJR Am J Roentgenol
, vol.186
, Issue.6
, pp. 1491-1496
-
-
Shinners, T.J.1
Pickhardt, P.J.2
Taylor, A.J.3
-
18
-
-
33644841724
-
Automated insufflation of carbon dioxide for MDCT colonography: Distension and patient experience compared with manual insufflation
-
D. Burling, S.A. Taylor, and S. Halligan Automated insufflation of carbon dioxide for MDCT colonography: distension and patient experience compared with manual insufflation AJR Am J Roentgenol 186 1 2006 96 103
-
(2006)
AJR Am J Roentgenol
, vol.186
, Issue.1
, pp. 96-103
-
-
Burling, D.1
Taylor, S.A.2
Halligan, S.3
-
19
-
-
33646161486
-
Advice for optimizing colonic distention and minimizing risk of perforation during CT colonography
-
A.H. Dachman Advice for optimizing colonic distention and minimizing risk of perforation during CT colonography Radiology 239 2 2006 317 321
-
(2006)
Radiology
, vol.239
, Issue.2
, pp. 317-321
-
-
Dachman, A.H.1
-
20
-
-
52249108133
-
Accuracy of CT colonography for detection of large adenomas and cancers
-
C.D. Johnson, M.H. Chen, and A.Y. Toledano Accuracy of CT colonography for detection of large adenomas and cancers N Engl J Med 359 12 2008 1207 1217
-
(2008)
N Engl J Med
, vol.359
, Issue.12
, pp. 1207-1217
-
-
Johnson, C.D.1
Chen, M.H.2
Toledano, A.Y.3
-
21
-
-
58849136275
-
Comparison of CT colonography, colonoscopy, sigmoidoscopy and faecal occult blood tests for the detection of advanced adenoma in an average risk population
-
A. Graser, P. Stieber, and D. Nagel Comparison of CT colonography, colonoscopy, sigmoidoscopy and faecal occult blood tests for the detection of advanced adenoma in an average risk population Gut 58 2 2009 241 248
-
(2009)
Gut
, vol.58
, Issue.2
, pp. 241-248
-
-
Graser, A.1
Stieber, P.2
Nagel, D.3
-
22
-
-
58249084533
-
Hyoscine butylbromide - A review on its parenteral use in acute abdominal spasm and as an aid in abdominal diagnostic and therapeutic procedures
-
G.N. Tytgat Hyoscine butylbromide - a review on its parenteral use in acute abdominal spasm and as an aid in abdominal diagnostic and therapeutic procedures Curr Med Res Opin 24 11 2008 3159 3173
-
(2008)
Curr Med Res Opin
, vol.24
, Issue.11
, pp. 3159-3173
-
-
Tytgat, G.N.1
-
23
-
-
67349157160
-
Aperistaltic effect of hyoscine N-butylbromide versus glucagon on the small bowel assessed by magnetic resonance imaging
-
J.M. Froehlich, M. Daenzer, C. Weymarn, and von Aperistaltic effect of hyoscine N-butylbromide versus glucagon on the small bowel assessed by magnetic resonance imaging Eur Radiol 19 6 2009 1387 1393
-
(2009)
Eur Radiol
, vol.19
, Issue.6
, pp. 1387-1393
-
-
Froehlich, J.M.1
Daenzer, M.2
Weymarn, C.3
Von4
-
24
-
-
42949137567
-
ACR practice guideline for the performance of computed tomography (CT) colonography in adults
-
ACR practice guideline for the performance of computed tomography (CT) colonography in adults Am Coll Radiol 2009 1 10
-
(2009)
Am Coll Radiol
, pp. 1-10
-
-
-
25
-
-
0027383536
-
Antispasmodic drugs to reduce discomfort and colonic spasm during barium enemas: Comparison of oral hyoscyamine, i.v. glucagon, and no drug
-
J.G. Bova, R.A. Jurdi, and W.F. Bennett Antispasmodic drugs to reduce discomfort and colonic spasm during barium enemas: comparison of oral hyoscyamine, i.v. glucagon, and no drug AJR Am J Roentgenol 161 5 1993 965 968
-
(1993)
AJR Am J Roentgenol
, vol.161
, Issue.5
, pp. 965-968
-
-
Bova, J.G.1
Jurdi, R.A.2
Bennett, W.F.3
-
26
-
-
0017134615
-
Glucagon and barium enema examinations: A controlled clinical trial
-
R.K. Harned, C.B. Stelling, and S. Williams Glucagon and barium enema examinations: a controlled clinical trial AJR Am J Roentgenol 126 5 1976 981 984
-
(1976)
AJR Am J Roentgenol
, vol.126
, Issue.5
, pp. 981-984
-
-
Harned, R.K.1
Stelling, C.B.2
Williams, S.3
-
27
-
-
0029153797
-
Use of antispasmodic drugs in double contrast barium enema examination: Glucagon or buscopan?
-
R. Goei, M. Nix, and A.H. Kessels Use of antispasmodic drugs in double contrast barium enema examination: glucagon or buscopan? Clin Radiol 50 8 1995 553 557
-
(1995)
Clin Radiol
, vol.50
, Issue.8
, pp. 553-557
-
-
Goei, R.1
Nix, M.2
Kessels, A.H.3
-
28
-
-
0020053171
-
Routine use of hyoscine N butylbromide (Buscopan) in double contrast barium enema examinations
-
J.R. Lee Routine use of hyoscine N butylbromide (Buscopan) in double contrast barium enema examinations Clin Radiol 33 3 1982 273 276
-
(1982)
Clin Radiol
, vol.33
, Issue.3
, pp. 273-276
-
-
Lee, J.R.1
-
29
-
-
0032965930
-
The usefulness of glucagon hydrochloride for colonic distention in CT colonography
-
J. Yee, R.K. Hung, and G.A. Akerkar The usefulness of glucagon hydrochloride for colonic distention in CT colonography AJR Am J Roentgenol 173 1 1999 169 172
-
(1999)
AJR Am J Roentgenol
, vol.173
, Issue.1
, pp. 169-172
-
-
Yee, J.1
Hung, R.K.2
Akerkar, G.A.3
-
30
-
-
0141506956
-
Efficacy of IV Buscopan as a muscle relaxant in CT colonography
-
J.F. Bruzzi, A.C. Moss, and D.D. Brennan Efficacy of IV Buscopan as a muscle relaxant in CT colonography Eur Radiol 13 10 2003 2264 2270
-
(2003)
Eur Radiol
, vol.13
, Issue.10
, pp. 2264-2270
-
-
Bruzzi, J.F.1
Moss, A.C.2
Brennan, D.D.3
-
31
-
-
20744445972
-
Spasmolysis at CT colonography: Butyl scopolamine versus glucagon
-
P. Rogalla, A. Lembcke, and J.C. Rückert Spasmolysis at CT colonography: butyl scopolamine versus glucagon Radiology 236 1 2005 184 188
-
(2005)
Radiology
, vol.236
, Issue.1
, pp. 184-188
-
-
Rogalla, P.1
Lembcke, A.2
Rückert, J.C.3
-
32
-
-
55949116172
-
Effect of intravenous Buscopan on colonic distention during computed tomography colonography
-
C. Behrens, G. Stevenson, and R. Eddy Effect of intravenous Buscopan on colonic distention during computed tomography colonography Can Assoc Radiol J 59 4 2008 183 190
-
(2008)
Can Assoc Radiol J
, vol.59
, Issue.4
, pp. 183-190
-
-
Behrens, C.1
Stevenson, G.2
Eddy, R.3
-
34
-
-
0036516942
-
CT colonography: Colonic distention improved by dual positioning but not intravenous glucagon
-
M.M. Morrin, R.J. Farrell, and M.T. Keogan CT colonography: colonic distention improved by dual positioning but not intravenous glucagon Eur Radiol 12 3 2002 525 530
-
(2002)
Eur Radiol
, vol.12
, Issue.3
, pp. 525-530
-
-
Morrin, M.M.1
Farrell, R.J.2
Keogan, M.T.3
-
35
-
-
34447645094
-
Optimization of CT colonography technique: A practical guide
-
D.J.M. Tolan, E.M. Armstrong, and D. Burling Optimization of CT colonography technique: a practical guide Clin Radiol 62 9 2007 819 827
-
(2007)
Clin Radiol
, vol.62
, Issue.9
, pp. 819-827
-
-
Tolan, D.J.M.1
Armstrong, E.M.2
Burling, D.3
-
36
-
-
0025141170
-
Glucagon: Common untoward reactions - Review and recommendations
-
S.M. Chernish, and D.D. Maglinte Glucagon: common untoward reactions - review and recommendations Radiology 177 1 1990 145 146
-
(1990)
Radiology
, vol.177
, Issue.1
, pp. 145-146
-
-
Chernish, S.M.1
Maglinte, D.D.2
-
37
-
-
77955977170
-
Cost-effectiveness of computed tomographic colonography screening for colorectal cancer in the medicare population
-
A.B. Knudsen, I. Lansdorp-Vogelaar, and C.M. Rutter Cost-effectiveness of computed tomographic colonography screening for colorectal cancer in the medicare population J Natl Cancer Inst 102 16 2010 1238 1252
-
(2010)
J Natl Cancer Inst
, vol.102
, Issue.16
, pp. 1238-1252
-
-
Knudsen, A.B.1
Lansdorp-Vogelaar, I.2
Rutter, C.M.3
-
38
-
-
58749084870
-
At what costs will screening with CT colonography be competitive? A cost-effectiveness approach
-
I. Lansdorp-Vogelaar, M. van Ballegooijen, and A.G. Zauber At what costs will screening with CT colonography be competitive? A cost-effectiveness approach Int J Cancer 124 5 2009 1161 1168
-
(2009)
Int J Cancer
, vol.124
, Issue.5
, pp. 1161-1168
-
-
Lansdorp-Vogelaar, I.1
Van Ballegooijen, M.2
Zauber, A.G.3
-
39
-
-
77954041320
-
Study protocol: Population screening for colorectal cancer by colonoscopy or CT colonography: A randomized controlled trial
-
T.R. de Wijkerslooth, M.C. de Haan, and E.M. Stoop Study protocol: population screening for colorectal cancer by colonoscopy or CT colonography: a randomized controlled trial BMC Gastroenterol 10 2010 47
-
(2010)
BMC Gastroenterol
, vol.10
, pp. 47
-
-
De Wijkerslooth, T.R.1
De Haan, M.C.2
Stoop, E.M.3
-
40
-
-
34547596744
-
Screening CT colonography: How i do it
-
P.J. Pickhardt Screening CT colonography: how I do it AJR Am J Roentgenol 189 2 2007 290 298
-
(2007)
AJR Am J Roentgenol
, vol.189
, Issue.2
, pp. 290-298
-
-
Pickhardt, P.J.1
-
41
-
-
0033065857
-
CT colonography: Value of scanning in both the supine and prone positions
-
S.C. Chen, D.S. Lu, and J.R. Hecht CT colonography: value of scanning in both the supine and prone positions AJR Am J Roentgenol 172 3 1999 595 599
-
(1999)
AJR Am J Roentgenol
, vol.172
, Issue.3
, pp. 595-599
-
-
Chen, S.C.1
Lu, D.S.2
Hecht, J.R.3
-
42
-
-
0037371529
-
Comparison of supine and prone scanning separately and in combination at CT colonography
-
J. Yee, N.N. Kumar, and R.K. Hung Comparison of supine and prone scanning separately and in combination at CT colonography Radiology 226 3 2003 653 661
-
(2003)
Radiology
, vol.226
, Issue.3
, pp. 653-661
-
-
Yee, J.1
Kumar, N.N.2
Hung, R.K.3
-
43
-
-
2542500667
-
Supine/left decubitus scanning: A valuable alternative to supine/prone scanning in CT colonography
-
S.S. Gryspeerdt, M.J. Herman, and M.A. Baekelandt Supine/left decubitus scanning: a valuable alternative to supine/prone scanning in CT colonography Eur Radiol 14 5 2004 768 777
-
(2004)
Eur Radiol
, vol.14
, Issue.5
, pp. 768-777
-
-
Gryspeerdt, S.S.1
Herman, M.J.2
Baekelandt, M.A.3
-
44
-
-
0033693275
-
Utility of intravenously administered contrast material at CT colonography
-
M.M. Morrin, R.J. Farrell, and J.B. Kruskal Utility of intravenously administered contrast material at CT colonography Radiology 217 3 2000 765 771
-
(2000)
Radiology
, vol.217
, Issue.3
, pp. 765-771
-
-
Morrin, M.M.1
Farrell, R.J.2
Kruskal, J.B.3
-
45
-
-
69849107388
-
Diagnostic accuracy and tolerability of contrast enhanced CT colonoscopy in symptomatic patients with increased risk for colorectal cancer
-
Y. Ozsunar, G. Coskun, and N. Delibaş Diagnostic accuracy and tolerability of contrast enhanced CT colonoscopy in symptomatic patients with increased risk for colorectal cancer Eur J Radiol 71 3 2009 513 518
-
(2009)
Eur J Radiol
, vol.71
, Issue.3
, pp. 513-518
-
-
Ozsunar, Y.1
Coskun, G.2
Delibaş, N.3
-
46
-
-
53749088507
-
The efficacy of intravenous contrast-enhanced 16-raw multidetector CT colonography for detecting patients with colorectal polyps in an asymptomatic population in Korea
-
Y.S. Kim, N. Kim, and S.H. Kim The efficacy of intravenous contrast-enhanced 16-raw multidetector CT colonography for detecting patients with colorectal polyps in an asymptomatic population in Korea J Clin Gastroenterol 42 7 2008 791 798
-
(2008)
J Clin Gastroenterol
, vol.42
, Issue.7
, pp. 791-798
-
-
Kim, Y.S.1
Kim, N.2
Kim, S.H.3
-
47
-
-
34250874545
-
Colorectal polyps on portal phase contrast-enhanced CT colonography: Lesion attenuation and distinction from tagged feces
-
S.S. Lee, S.H. Park, and E.K. Choi Colorectal polyps on portal phase contrast-enhanced CT colonography: lesion attenuation and distinction from tagged feces AJR Am J Roentgenol 189 1 2007 35 40
-
(2007)
AJR Am J Roentgenol
, vol.189
, Issue.1
, pp. 35-40
-
-
Lee, S.S.1
Park, S.H.2
Choi, E.K.3
-
48
-
-
0038714424
-
Colorectal neoplasms: Role of intravenous contrast-enhanced CT colonography
-
J. Sosna, M.M. Morrin, and J.B. Kruskal Colorectal neoplasms: role of intravenous contrast-enhanced CT colonography Radiology 228 1 2003 152 156
-
(2003)
Radiology
, vol.228
, Issue.1
, pp. 152-156
-
-
Sosna, J.1
Morrin, M.M.2
Kruskal, J.B.3
-
49
-
-
33751332769
-
Assessment of polyp and mass histopathology by intravenous contrast-enhanced CT colonography
-
R.M. Summers, A. Huang, and J. Yao Assessment of polyp and mass histopathology by intravenous contrast-enhanced CT colonography Acad Radiol 13 12 2006 1490 1495
-
(2006)
Acad Radiol
, vol.13
, Issue.12
, pp. 1490-1495
-
-
Summers, R.M.1
Huang, A.2
Yao, J.3
-
50
-
-
0037929690
-
CT attenuation of colorectal polypoid lesions: Evaluation of contrast enhancement in CT colonography
-
A. Oto, V. Gelebek, and B.S. Oguz CT attenuation of colorectal polypoid lesions: evaluation of contrast enhancement in CT colonography Eur Radiol 13 7 2003 1657 1663
-
(2003)
Eur Radiol
, vol.13
, Issue.7
, pp. 1657-1663
-
-
Oto, A.1
Gelebek, V.2
Oguz, B.S.3
-
51
-
-
28544450856
-
CT colonography: Contrast enhancement of benign and malignant colorectal lesions versus fecal residuals
-
E. Neri, P. Vagli, and S. Picchietti CT colonography: contrast enhancement of benign and malignant colorectal lesions versus fecal residuals Abdom Imaging 30 6 2005 694 697
-
(2005)
Abdom Imaging
, vol.30
, Issue.6
, pp. 694-697
-
-
Neri, E.1
Vagli, P.2
Picchietti, S.3
-
52
-
-
78651258001
-
Post-surgical follow-up of colorectal cancer: Role of contrast-enhanced CT colonography
-
E. Neri, P. Vagli, and F. Turini Post-surgical follow-up of colorectal cancer: role of contrast-enhanced CT colonography Abdom Imaging 35 6 2010 669 675
-
(2010)
Abdom Imaging
, vol.35
, Issue.6
, pp. 669-675
-
-
Neri, E.1
Vagli, P.2
Turini, F.3
-
53
-
-
0038757577
-
Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: A feasibility study
-
A. Laghi, R. Iannaccone, and E. Bria Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study Eur Radiol 13 4 2003 883 889
-
(2003)
Eur Radiol
, vol.13
, Issue.4
, pp. 883-889
-
-
Laghi, A.1
Iannaccone, R.2
Bria, E.3
-
54
-
-
0036150701
-
Colonography in recurrent colorectal carcinoma: Feasibility of simultaneous evaluation for metastatic disease, local recurrence and metachronous neoplasia in colorectal carcinoma
-
J.G. Fletcher, C.D. Johnson, and W.R. Krueger Colonography in recurrent colorectal carcinoma: feasibility of simultaneous evaluation for metastatic disease, local recurrence and metachronous neoplasia in colorectal carcinoma AJR Am J Roentgenol 178 2 2002 283 290
-
(2002)
AJR Am J Roentgenol
, vol.178
, Issue.2
, pp. 283-290
-
-
Fletcher, J.G.1
Johnson, C.D.2
Krueger, W.R.3
-
55
-
-
31144444765
-
Evaluation of contrast-enhanced computed tomographic colonography in detection of local recurrent colorectal cancer
-
Y.T. You, C.R. Chang Chien, and J.Y. Wang Evaluation of contrast-enhanced computed tomographic colonography in detection of local recurrent colorectal cancer World J Gastroenterol 12 1 2006 123 126
-
(2006)
World J Gastroenterol
, vol.12
, Issue.1
, pp. 123-126
-
-
You, Y.T.1
Chang Chien, C.R.2
Wang, J.Y.3
-
56
-
-
26044444737
-
Importance of extracolonic findings at IV contrast medium-enhanced CT colonography versus those at non-enhanced CT colonography
-
A. Spreng, P. Netzer, and J. Mattich Importance of extracolonic findings at IV contrast medium-enhanced CT colonography versus those at non-enhanced CT colonography Eur Radiol 15 10 2005 2088 2095
-
(2005)
Eur Radiol
, vol.15
, Issue.10
, pp. 2088-2095
-
-
Spreng, A.1
Netzer, P.2
Mattich, J.3
-
57
-
-
0030059751
-
Technical report: Spiral CT pneumocolon for suspected colonic neoplasms
-
Z. Amin, P.B. Boulos, and W.R. Lees Technical report: spiral CT pneumocolon for suspected colonic neoplasms Clin Radiology 51 1 1996 56 61
-
(1996)
Clin Radiology
, vol.51
, Issue.1
, pp. 56-61
-
-
Amin, Z.1
Boulos, P.B.2
Lees, W.R.3
-
58
-
-
84879502486
-
Radiation risk management in low dose MDCT screening programs
-
D. Tack, P.A. Genenois, Springer Berlin/Heidelberg/New York
-
J. Stoker, H.W. Venema, and R.E. van Gelder Radiation risk management in low dose MDCT screening programs D. Tack, P.A. Genenois, Radiation dose from adult and pediatric multidetector computed tomography 2007 Springer Berlin/Heidelberg/New York 255 272
-
(2007)
Radiation Dose from Adult and Pediatric Multidetector Computed Tomography
, pp. 255-272
-
-
Stoker, J.1
Venema, H.W.2
Van Gelder, R.E.3
-
60
-
-
34548274445
-
Effect of slice thickness and primary 2D versus 3D virtual dissection on colorectal lesion detection at CT colonography in 452 asymptomatic adults
-
C.D. Johnson, J.G. Fletcher, and R.L. MacCarty Effect of slice thickness and primary 2D versus 3D virtual dissection on colorectal lesion detection at CT colonography in 452 asymptomatic adults AJR Am J Roentgenol 189 3 2007 672 680
-
(2007)
AJR Am J Roentgenol
, vol.189
, Issue.3
, pp. 672-680
-
-
Johnson, C.D.1
Fletcher, J.G.2
Maccarty, R.L.3
-
61
-
-
0141451920
-
Multi-detector row CT colonography: Effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen
-
S.A. Taylor, S. Halligan, and C.I. Bartram Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen Radiology 229 1 2003 109 118
-
(2003)
Radiology
, vol.229
, Issue.1
, pp. 109-118
-
-
Taylor, S.A.1
Halligan, S.2
Bartram, C.I.3
-
62
-
-
49049094056
-
Effects of spatial resolution and tube current on computer-aided detection of polyps on CT colonographic images: Phantom study
-
S.H. Kim, J.M. Lee, and C.I. Shin Effects of spatial resolution and tube current on computer-aided detection of polyps on CT colonographic images: phantom study Radiology 248 2 2008 492 503
-
(2008)
Radiology
, vol.248
, Issue.2
, pp. 492-503
-
-
Kim, S.H.1
Lee, J.M.2
Shin, C.I.3
-
63
-
-
0037366638
-
General principles of MDCT
-
SUPPL.
-
M. Prokop General principles of MDCT Eur J Radiol 45 Suppl. 2003 S4 S10
-
(2003)
Eur J Radiol
, vol.45
-
-
Prokop, M.1
-
64
-
-
61349187579
-
Application- and patient size-dependent optimization of x-ray spectra for CT
-
W.A. Kalender, P. Deak, and M. Kellermeier Application- and patient size-dependent optimization of x-ray spectra for CT Med Phys 36 3 2009 993 1007
-
(2009)
Med Phys
, vol.36
, Issue.3
, pp. 993-1007
-
-
Kalender, W.A.1
Deak, P.2
Kellermeier, M.3
-
65
-
-
0036085139
-
CT colonography at different radiation dose levels: Feasibility of dose reduction
-
R.E. van Gelder, H.W. Venema, and I.W.O. Serlie CT colonography at different radiation dose levels: feasibility of dose reduction Radiology 224 1 2002 25 33
-
(2002)
Radiology
, vol.224
, Issue.1
, pp. 25-33
-
-
Van Gelder, R.E.1
Venema, H.W.2
Serlie, I.W.O.3
-
66
-
-
3242815478
-
CT colonography: Feasibility of substantial dose reduction - Comparison of medium to very low doses in identical patients
-
R.E. van Gelder, H.W. Venema, and J. Florie CT colonography: feasibility of substantial dose reduction - comparison of medium to very low doses in identical patients Radiology 232 2 2004 611 620
-
(2004)
Radiology
, vol.232
, Issue.2
, pp. 611-620
-
-
Van Gelder, R.E.1
Venema, H.W.2
Florie, J.3
-
67
-
-
16544364276
-
Feasibility of MDCT colonography in ultra-low-dose technique in the detection of colorectal lesions: Comparison with high-resolution video colonoscopy
-
M. Cohnen, C. Vogt, and A. Beck Feasibility of MDCT colonography in ultra-low-dose technique in the detection of colorectal lesions: comparison with high-resolution video colonoscopy AJR Am J Roentgenol 183 5 2004 1355 1359
-
(2004)
AJR Am J Roentgenol
, vol.183
, Issue.5
, pp. 1355-1359
-
-
Cohnen, M.1
Vogt, C.2
Beck, A.3
-
68
-
-
27744439367
-
Colorectal polyps: Detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies
-
R. Iannaccone, C. Catalano, and F. Mangiapane Colorectal polyps: detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies Radiology 237 3 2005 927 937
-
(2005)
Radiology
, vol.237
, Issue.3
, pp. 927-937
-
-
Iannaccone, R.1
Catalano, C.2
Mangiapane, F.3
-
69
-
-
77952310162
-
Evaluation of image quality and lesion perception by human readers on 3D CT colonography: Comparison of standard and low radiation dose
-
V.A. Fisichella, M. Båth, and A. Allansdotter Johnsson Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose Eur Radiol 20 3 2010 630 639
-
(2010)
Eur Radiol
, vol.20
, Issue.3
, pp. 630-639
-
-
Fisichella, V.A.1
Båth, M.2
Allansdotter Johnsson, A.3
-
70
-
-
53249125059
-
Influence of tagged fecal material on detectability of colorectal polyps at CT: Phantom study
-
A.H. de Vries, H.W. Venema, and J. Florie Influence of tagged fecal material on detectability of colorectal polyps at CT: phantom study AJR Am J Roentgenol 191 4 2008 1101
-
(2008)
AJR Am J Roentgenol
, vol.191
, Issue.4
, pp. 1101
-
-
De Vries, A.H.1
Venema, H.W.2
Florie, J.3
-
71
-
-
77954708865
-
Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
-
K.T. Flicek, A.K. Hara, and A.C. Silva Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study AJR Am J Roentgenol 195 1 2010 126 131
-
(2010)
AJR Am J Roentgenol
, vol.195
, Issue.1
, pp. 126-131
-
-
Flicek, K.T.1
Hara, A.K.2
Silva, A.C.3
-
72
-
-
77956841482
-
Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
-
Y. Sagara, A.K. Hara, and W. Pavlicek Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients AJR Am J Roentgenol 195 3 2010 713 719
-
(2010)
AJR Am J Roentgenol
, vol.195
, Issue.3
, pp. 713-719
-
-
Sagara, Y.1
Hara, A.K.2
Pavlicek, W.3
-
73
-
-
0032932149
-
Dosage reduction in computed tomography by anatomy-oriented attenuation-based tube-current modulation: The first clinical results
-
H. Greess, H. Wolf, and U. Baum Dosage reduction in computed tomography by anatomy-oriented attenuation-based tube-current modulation: the first clinical results RöFo 170 3 1999 246 250
-
(1999)
RöFo
, vol.170
, Issue.3
, pp. 246-250
-
-
Greess, H.1
Wolf, H.2
Baum, U.3
-
74
-
-
13244297711
-
Techniques and applications of automatic tube current modulation for CT
-
M.K. Kalra, M.M. Maher, and T.L. Toth Techniques and applications of automatic tube current modulation for CT Radiology 233 3 2004 649 657
-
(2004)
Radiology
, vol.233
, Issue.3
, pp. 649-657
-
-
Kalra, M.K.1
Maher, M.M.2
Toth, T.L.3
-
75
-
-
33645562681
-
CT dose reduction and dose management tools: Overview of available options
-
C.H. McCollough, M.R. Bruesewitz, and J.M. Kofler CT dose reduction and dose management tools: overview of available options Radiographics 26 2 2006 503 512
-
(2006)
Radiographics
, vol.26
, Issue.2
, pp. 503-512
-
-
McCollough, C.H.1
Bruesewitz, M.R.2
Kofler, J.M.3
-
76
-
-
22344437374
-
Mass screening with CT colonography: Should the radiation exposure be of concern?
-
D. Brenner, and M. Georgsson Mass screening With CT colonography: should the radiation exposure be of concern? Gastroenterology 129 1 2005 328 337
-
(2005)
Gastroenterology
, vol.129
, Issue.1
, pp. 328-337
-
-
Brenner, D.1
Georgsson, M.2
-
77
-
-
70149100406
-
Dual energy virtual CT colonoscopy with dual source computed tomography: Initial experience
-
M. Karcaaltincaba, D. Karaosmanoglu, and D. Akata Dual energy virtual CT colonoscopy with dual source computed tomography: initial experience RöFo 181 9 2009 859 862
-
(2009)
RöFo
, vol.181
, Issue.9
, pp. 859-862
-
-
Karcaaltincaba, M.1
Karaosmanoglu, D.2
Akata, D.3
-
78
-
-
77955335310
-
Dual-energy based spectral electronic cleansing in non-cathartic computed tomography colonography: An emerging novel technique
-
R. Eliahou, Y. Azraq, and R. Carmi Dual-energy based spectral electronic cleansing in non-cathartic computed tomography colonography: an emerging novel technique Semin Ultrasound CT MR 31 4 2010 309 314
-
(2010)
Semin Ultrasound CT MR
, vol.31
, Issue.4
, pp. 309-314
-
-
Eliahou, R.1
Azraq, Y.2
Carmi, R.3
-
79
-
-
34248673159
-
Material differentiation by dual energy CT: Initial experience
-
T.R.C. Johnson, B. Krauss, and M. Sedlmair Material differentiation by dual energy CT: initial experience Eur Radiol 17 6 2007 1510 1517
-
(2007)
Eur Radiol
, vol.17
, Issue.6
, pp. 1510-1517
-
-
Johnson, T.R.C.1
Krauss, B.2
Sedlmair, M.3
-
80
-
-
78649692112
-
Dual-source dual-energy CT with additional tin filtration: Dose and image quality evaluation in phantoms and in vivo
-
A.N. Primak, J.C.R. Giraldo, and C.D. Eusemann Dual-source dual-energy CT with additional tin filtration: dose and image quality evaluation in phantoms and in vivo AJR Am J Roentgenol 195 5 2010 1164 1174
-
(2010)
AJR Am J Roentgenol
, vol.195
, Issue.5
, pp. 1164-1174
-
-
Primak, A.N.1
Giraldo, J.C.R.2
Eusemann, C.D.3
|