Alumina and its use in surgery of the hip. (experimental study)]
-
Boutin P. [Alumina and its use in surgery of the hip. (Experimental study)]. Presse Med 1971; 79(14): 639-640.
-
(1971)
Presse Med
, vol.79
, Issue.14
, pp. 639-640
-
-
Boutin, P.1
-
2
-
-
0029597924
-
Improvement of the safety of ceramic femoral heads for total hip replacement
-
Willmann G, Pfaff HG and Richter HG. Improvement of the safety of ceramic femoral heads for total hip replacement. Biomed Tech (Berl) 1995; 40(12): 342-346.
-
(1995)
Biomed Tech (Berl)
, vol.40
, Issue.12
, pp. 342-346
-
-
Willmann, G.1
Pfaff, H.G.2
Richter, H.G.3
-
3
-
-
0000972849
-
High strength and toughness alumina matrix composites by transformation toughening and 'in situ' platelet reinforcement (zpta) -The new generation of bioceramics
-
In: Giannini SMA (ed.)
-
Burger W and Richter HG. High strength and toughness alumina matrix composites by transformation toughening and 'in situ' platelet reinforcement (ZPTA) -the new generation of bioceramics. In: Giannini SMA (ed.) Bioceramics. Zurich-Uetikon: Trans Tech Publications Ltd; 2000, pp.545-548.
-
(2000)
Bioceramics. Zurich-Uetikon: Trans Tech Publications Ltd
, pp. 545-548
-
-
Burger, W.1
Richter, H.G.2
-
4
-
-
64249095347
-
Emergence of the alumina matrix composite in total hip arthroplasty
-
Masson B. Emergence of the alumina matrix composite in total hip arthroplasty. Int Orthop 2009; 33(2): 359-363.
-
(2009)
Int Orthop
, vol.33
, Issue.2
, pp. 359-363
-
-
Masson, B.1
-
5
-
-
36649004498
-
Ceramic-ceramic coupling with big heads: Clinical outcome
-
Zagra L and Giacometti Ceroni R. Ceramic-ceramic coupling with big heads: clinical outcome. Eur J Orthop Surg Traumatol 2007; 17(3): 247-251.
-
(2007)
Eur J Orthop Surg Traumatol
, vol.17
, Issue.3
, pp. 247-251
-
-
Zagra, L.1
Giacometti Ceroni, R.2
-
6
-
-
0035114433
-
The influence of acetabular cup angle on the wear of. 'biolox forte' alumina ceramic bearing couples in a hip joint simulator
-
Nevelos JE, Ingham E, Doyle C, et al. The influence of acetabular cup angle on the wear of 'BIOLOX forte' alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 2001; 12(2): 141-144.
-
(2001)
J Mater Sci Mater Med
, vol.12
, Issue.2
, pp. 141-144
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
-
7
-
-
0034981637
-
Comparative analysis of two different types of aluminaalumina hip prosthesis retrieved for aseptic loosening
-
Nevelos JE, Prudhommeaux F, Hamadouche M, et al. Comparative analysis of two different types of aluminaalumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg Br 2001; 83(4): 598-603.
-
(2001)
J Bone Joint Surg Br
, vol.83
, Issue.4
, pp. 598-603
-
-
Nevelos, J.E.1
Prudhommeaux, F.2
Hamadouche, M.3
-
8
-
-
84879216840
-
Large head diameters have the potential to reduce ion release in metalon-metal hip wear simulations
-
Washington, DC
-
Bowsher JG, Hussain A, Williams PA, et al. Large head diameters have the potential to reduce ion release in metalon-metal hip wear simulations. Orthopaedic Research Society. Washington, DC, 2005, p.1626.
-
(2005)
Orthopaedic Research Society
, pp. 1626
-
-
Bowsher, J.G.1
Hussain, A.2
Williams, P.A.3
-
9
-
-
52449102219
-
Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements -An in vitro study
-
Leslie I, Williams S, Brown C, et al. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements -an in vitro study. J Biomed Mater Res B Appl Biomater 2008; 87(1): 163-172.
-
(2008)
J Biomed Mater Res B Appl Biomater
, vol.87
, Issue.1
, pp. 163-172
-
-
Leslie, I.1
Williams, S.2
Brown, C.3
-
10
-
-
9644255691
-
Comparative wear under different conditions of surface-engineered metalon-metal bearings for total hip arthroplasty
-
Williams S, Isaac G, Hatto P, et al. Comparative wear under different conditions of surface-engineered metalon-metal bearings for total hip arthroplasty. J Arthroplasty 2004; 19(8 Suppl. 3): 112-117.
-
(2004)
J Arthroplasty
, vol.19
, Issue.8 SUPPL. 3
, pp. 112-117
-
-
Williams, S.1
Isaac, G.2
Hatto, P.3
-
11
-
-
0030623710
-
Wear of ultrahigh molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant. Proc imeche, part h
-
Bigsby RJA, Hardaker CS and Fisher J. Wear of ultrahigh molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant. Proc IMechE, Part H: J Engineering in Medicine 1997; 211(3): 265-269.
-
(1997)
J Engineering in Medicine
, vol.211
, Issue.3
, pp. 265-269
-
-
Bigsby, R.J.A.1
Hardaker, C.S.2
Fisher, J.3
-
12
-
-
0033252313
-
A comparison between gravimetric and volumetric techniques of wear measurement of uhmwpe acetabular cups against zirconia and cobalt-chromium- molybdenum femoral heads in a hip simulator. Proc imeche, part h
-
Smith SL and Unsworth A. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator. Proc IMechE, Part H: J Engineering in Medicine 1999; 213(6): 475-483.
-
(1999)
J Engineering in Medicine
, vol.213
, Issue.6
, pp. 475-483
-
-
Smith, S.L.1
Unsworth, A.2
-
13
-
-
33947375583
-
Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations. Proc imeche, part h
-
Galvin AL, Tipper IL, Jennings LM, et al. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations. Proc IMechE, Part H: J Engineering in Medicine 2007; 221(1): 1-10.
-
(2007)
J Engineering in Medicine
, vol.221
, Issue.1
, pp. 1-10
-
-
Galvin, A.L.1
Tipper, I.L.2
Jennings, L.M.3
-
14
-
-
0346035850
-
Effects of clinically relevant alumina ceramic wear particles on tnf-alpha production by human peripheral blood mononuclear phagocytes
-
Hatton A, Nevelos JE, Matthews JB, et al. Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes. Biomaterials 2003; 24(7): 1193-1204.
-
(2003)
Biomaterials
, vol.24
, Issue.7
, pp. 1193-1204
-
-
Hatton, A.1
Nevelos, J.E.2
Matthews, J.B.3
-
15
-
-
0029902177
-
Ceramic femoral head fractures in total hip arthroplasty
-
Fritsch EW and Gleitz M. Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop Relat Res 1996; 328: 129-136.
-
(1996)
Clin Orthop Relat Res
, vol.328
, pp. 129-136
-
-
Fritsch, E.W.1
Gleitz, M.2
-
16
-
-
0041419860
-
Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
-
Hasegawa M, Sudo A, Hirata H, et al. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty 2003; 18(5): 658-661.
-
(2003)
J Arthroplasty
, vol.18
, Issue.5
, pp. 658-661
-
-
Hasegawa, M.1
Sudo, A.2
Hirata, H.3
-
17
-
-
80755136660
-
Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty
-
Chevillotte C, Pibarot V, Carret JP, et al. Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty. Int Orthop 2011; 35 (11): 1599-604.
-
(2011)
Int Orthop
, vol.35
, Issue.11
, pp. 1599-604
-
-
Chevillotte, C.1
Pibarot, V.2
Carret, J.P.3
-
18
-
-
78549292127
-
Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis
-
Kim YH, Choi Y and Kim JS. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop 2010; 34(8): 1123-1127.
-
(2010)
Int Orthop
, vol.34
, Issue.8
, pp. 1123-1127
-
-
Kim, Y.H.1
Choi, Y.2
Kim, J.S.3
-
19
-
-
36849075129
-
Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty
-
Lusty PJ, Tai CC, Sew-Hoy RP, et al. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am 2007; 89(12): 2676-2683.
-
(2007)
J Bone Joint Surg Am
, vol.89
, Issue.12
, pp. 2676-2683
-
-
Lusty, P.J.1
Tai, C.C.2
Sew-Hoy, R.P.3
-
20
-
-
0032881955
-
Analysis of retrieved alumina ceramic components from mittelmeier total hip prostheses
-
Nevelos JE, Ingham E, Doyle C, et al. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999; 20(19): 1833-1840.
-
(1999)
Biomaterials
, vol.20
, Issue.19
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
-
21
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
Nevelos J, Ingham E, Doyle C, et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 2000; 15(6): 793-795.
-
(2000)
J Arthroplasty
, vol.15
, Issue.6
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
-
22
-
-
0035989711
-
Alumina-alumina artificial hip joints. Part i: A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision
-
Hatton A, Nevelos JE, Nevelos AA, et al. Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision. Biomaterials 2002; 23(16): 3429-3440.
-
(2002)
Biomaterials
, vol.23
, Issue.16
, pp. 3429-3440
-
-
Hatton, A.1
Nevelos, J.E.2
Nevelos, A.A.3
-
23
-
-
0035989715
-
Alumina-alumina artificial hip joints. Part ii: Characterisation of the wear debris from in vitro hip joint simulations
-
Tipper JL, Hatton A, Nevelos JE, et al. Alumina-alumina artificial hip joints. Part II: characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 2002; 23(16): 3441-3448.
-
(2002)
Biomaterials
, vol.23
, Issue.16
, pp. 3441-3448
-
-
Tipper, J.L.1
Hatton, A.2
Nevelos, J.E.3
-
24
-
-
0035680629
-
Long-term wear of hiped alumina on alumina bearings for thr under microseparation conditions
-
Stewart T, Tipper J, Streicher R, et al. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001; 12(10-12): 1053-1056.
-
(2001)
J Mater Sci Mater Med
, vol.12
, Issue.10-12
, pp. 1053-1056
-
-
Stewart, T.1
Tipper, J.2
Streicher, R.3
-
25
-
-
0141535277
-
Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation
-
Stewart TD, Tipper JL, Insley G, et al. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. J Arthroplasty 2003; 18(6): 726-734.
-
(2003)
J Arthroplasty
, vol.18
, Issue.6
, pp. 726-734
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
-
26
-
-
49849087899
-
Modes of implant failure after hip resurfacing: Morphological and wear analysis of 267 retrieval specimens
-
Morlock MM, Bishop N, Zustin J, et al. Modes of implant failure after hip resurfacing: morphological and wear analysis of 267 retrieval specimens. J Bone Joint Surg Am 2008; 90: 89-95.
-
(2008)
J Bone Joint Surg Am
, vol.90
, pp. 89-95
-
-
Morlock, M.M.1
Bishop, N.2
Zustin, J.3
-
27
-
-
84879229470
-
Edge loading and wear of hip surface replacements, a comparison of clinical retrievals and simulator samples
-
New Orleans, LA
-
Leslie IJ, Campbell P, Williams S, et al. Edge loading and wear of hip surface replacements, a comparison of clinical retrievals and simulator samples. Orthopaedic Research Society. New Orleans, LA, 2010.
-
Orthopaedic Research Society
, vol.2010
-
-
Leslie, I.J.1
Campbell, P.2
Williams, S.3
-
28
-
-
78649658341
-
Effect of cup inclination angle during microseparation and rim loading on the wear of biolox(r) delta ceramic-on-ceramic total hip replacement
-
Al-Hajjar M, Leslie IJ, Tipper J, et al. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX(R) delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res B Appl Biomater 2010; 95(2): 263-268.
-
J Biomed Mater Res B Appl Biomater 2010
, vol.95
, Issue.2
, pp. 263-268
-
-
Al-Hajjar, M.1
Leslie, I.J.2
Tipper, J.3
-
29
-
-
0033641059
-
Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc imeche, part h
-
Clarke IC, Good V, Williams P, et al. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc IMechE, Part H: J Engineering in Medicine 2000; 214(4): 331-347.
-
(2000)
J Engineering in Medicine
, vol.214
, Issue.4
, pp. 331-347
-
-
Clarke, I.C.1
Good, V.2
Williams, P.3
-
31
-
-
49849095334
-
Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position
-
Williams S, Leslie I, Isaac G, et al. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg Am 2008; 90(Suppl. 3): 111-117.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL. 3
, pp. 111-117
-
-
Williams, S.1
Leslie, I.2
Isaac, G.3
-
32
-
-
69249208803
-
High cup angle and microseparation increase the wear of hip surface replacements
-
Leslie IJ, Williams S, Isaac G, et al. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res 2009; 467(9): 2259-2265.
-
(2009)
Clin Orthop Relat Res
, vol.467
, Issue.9
, pp. 2259-2265
-
-
Leslie, I.J.1
Williams, S.2
Isaac, G.3
-
33
-
-
67549091639
-
Influence of cup orientation on the wear performance of metal-on-metal hip replacements. Proc imeche, part h
-
Angadji A, Royle M, Collins SN, et al. Influence of cup orientation on the wear performance of metal-on-metal hip replacements. Proc IMechE, Part H:J Engineering in Medicine 2009; 223(44): 449-457.
-
(2009)
J Engineering in Medicine
, vol.223
, Issue.44
, pp. 449-457
-
-
Angadji, A.1
Royle, M.2
Collins, S.N.3
-
34
-
-
79953834792
-
The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements
-
Sexton SA, Yeung E, Jackson MP, et al. The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements. J Bone Joint Surg Br 2011; 93(4): 439-442.
-
J Bone Joint Surg Br 2011
, vol.93
, Issue.4
, pp. 439-442
-
-
Sexton, S.A.1
Yeung, E.2
Jackson, M.P.3
-
35
-
-
79952043319
-
The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations
-
Hothan A, Huber G, Weiss C, et al. The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations. J Biomech 2011; 44(5): 837-841.
-
(2011)
J Biomech
, vol.44
, Issue.5
, pp. 837-841
-
-
Hothan, A.1
Huber, G.2
Weiss, C.3
-
36
-
-
34848915750
-
The role of stripe wear in causing acoustic emissions from alumina ceramicon-ceramic bearings
-
Taylor S, Manley MT and Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramicon-ceramic bearings. J Arthroplasty 2007; 22(7 Suppl. 3): 47-51.
-
(2007)
J Arthroplasty
, vol.22
, Issue.7 SUPPL. 3
, pp. 47-51
-
-
Taylor, S.1
Manley, M.T.2
Sutton, K.3
-
37
-
-
76249109227
-
Tha with delta ceramic on ceramic: Results of a multicenter investigational device exemption trial
-
Hamilton WG, McAuley JP, Dennis DA, et al. THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res 2010; 468(2): 358-366.
-
(2010)
Clin Orthop Relat Res
, vol.468
, Issue.2
, pp. 358-366
-
-
Hamilton, W.G.1
McAuley, J.P.2
Dennis, D.A.3
|