메뉴 건너뛰기




Volumn 424, Issue , 2013, Pages 90-95

Systematic review and meta-analysis of flow cytometry in urinary tract infection screening

Author keywords

Automated urine sediment analyzer; Meta analysis; Systematic review; Urinary tract infection

Indexed keywords

ANALYZER; AUTOMATED URINE SEDIMENT ANALYZER; BACTERIUM DETECTION; DIAGNOSTIC ACCURACY; FLOW CYTOMETRY; HUMAN; LEUKOCYTE COUNT; META ANALYSIS; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; REVIEW; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; URINALYSIS; URINARY TRACT INFECTION; URINE SEDIMENT;

EID: 84879177493     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2013.05.014     Document Type: Review
Times cited : (66)

References (30)
  • 1
    • 78650106014 scopus 로고    scopus 로고
    • The epidemiology of urinary tract infection
    • Foxman B. The epidemiology of urinary tract infection. Nat Rev Urol 2010, 7:653-660.
    • (2010) Nat Rev Urol , vol.7 , pp. 653-660
    • Foxman, B.1
  • 2
    • 21244475983 scopus 로고    scopus 로고
    • Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection
    • Wiwanitkit V., Udomsantisuk N., Boonchalermvichian C. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection. Urol Res 2005, 33:220-222.
    • (2005) Urol Res , vol.33 , pp. 220-222
    • Wiwanitkit, V.1    Udomsantisuk, N.2    Boonchalermvichian, C.3
  • 4
    • 0027438852 scopus 로고
    • Diagnosis of urinary tract infection by urine microscopy using a disposable counting chamber
    • Hiraoka M., Hida Y., Tuchida S., et al. Diagnosis of urinary tract infection by urine microscopy using a disposable counting chamber. Scand J Clin Lab Invest 1993, 53:705-709.
    • (1993) Scand J Clin Lab Invest , vol.53 , pp. 705-709
    • Hiraoka, M.1    Hida, Y.2    Tuchida, S.3
  • 5
    • 77950504099 scopus 로고    scopus 로고
    • Evaluation of the Sysmex UF-1000i for the diagnosis of urinary tract infection
    • Wang J., Zhang Y., Xu D., Shao W., Lu Y. Evaluation of the Sysmex UF-1000i for the diagnosis of urinary tract infection. Am J Clin Pathol 2010, 133:577-582.
    • (2010) Am J Clin Pathol , vol.133 , pp. 577-582
    • Wang, J.1    Zhang, Y.2    Xu, D.3    Shao, W.4    Lu, Y.5
  • 6
    • 0037879366 scopus 로고    scopus 로고
    • Determination of cut-off values for leucocytes and bacteria for urine flow cytometer (UF-100) in urinary tract infections
    • Koken T., Aktepe O.C., Serteser M., Samli M., Kahraman A., Dogan N. Determination of cut-off values for leucocytes and bacteria for urine flow cytometer (UF-100) in urinary tract infections. Int Urol Nephrol 2002, 34:175-178.
    • (2002) Int Urol Nephrol , vol.34 , pp. 175-178
    • Koken, T.1    Aktepe, O.C.2    Serteser, M.3    Samli, M.4    Kahraman, A.5    Dogan, N.6
  • 7
    • 34548565908 scopus 로고    scopus 로고
    • Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting
    • Shayanfar N., Tobler U., von Eckardstein A., Bestmann L. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting. Clin Chem Lab Med 2007, 45:1251-1256.
    • (2007) Clin Chem Lab Med , vol.45 , pp. 1251-1256
    • Shayanfar, N.1    Tobler, U.2    von Eckardstein, A.3    Bestmann, L.4
  • 8
    • 34547838282 scopus 로고    scopus 로고
    • Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy
    • Chien T.I., Kao J.T., Liu H.L., et al. Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy. Clin Chim Acta 2007, 384:28-34.
    • (2007) Clin Chim Acta , vol.384 , pp. 28-34
    • Chien, T.I.1    Kao, J.T.2    Liu, H.L.3
  • 9
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P., Rutjes A.W., Reitsma J.B., Bossuyt P.M., Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003, 3:25.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 10
    • 0028316145 scopus 로고
    • Guidelines for meta-analyses evaluating diagnostic tests
    • Irwig L., Tosteson A.N., Gatsonis C., et al. Guidelines for meta-analyses evaluating diagnostic tests. Ann Intern Med 1994, 120:667-676.
    • (1994) Ann Intern Med , vol.120 , pp. 667-676
    • Irwig, L.1    Tosteson, A.N.2    Gatsonis, C.3
  • 11
    • 0027290944 scopus 로고
    • Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations
    • Moses L.E., Shapiro D., Littenberg B. Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med 1993, 12:1293-1316.
    • (1993) Stat Med , vol.12 , pp. 1293-1316
    • Moses, L.E.1    Shapiro, D.2    Littenberg, B.3
  • 12
    • 0037093923 scopus 로고    scopus 로고
    • Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
    • Walter S.D. Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data. Stat Med 2002, 21:1237-1256.
    • (2002) Stat Med , vol.21 , pp. 1237-1256
    • Walter, S.D.1
  • 15
    • 76649106739 scopus 로고    scopus 로고
    • Use of flow cytometry (Sysmex) UF-100) to screen for positive urine cultures: in search for the ideal cut-off
    • Brilha S., Proenca H., Cristino J.M., Hanscheid T. Use of flow cytometry (Sysmex) UF-100) to screen for positive urine cultures: in search for the ideal cut-off. Clin Chem Lab Med 2010, 48:289-292.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 289-292
    • Brilha, S.1    Proenca, H.2    Cristino, J.M.3    Hanscheid, T.4
  • 16
    • 79952348081 scopus 로고    scopus 로고
    • Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer
    • Broeren M.A., Bahceci S., Vader H.L., Arents N.L. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer. J Clin Microbiol 2011, 49:1025-1029.
    • (2011) J Clin Microbiol , vol.49 , pp. 1025-1029
    • Broeren, M.A.1    Bahceci, S.2    Vader, H.L.3    Arents, N.L.4
  • 17
    • 77953285006 scopus 로고    scopus 로고
    • Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection
    • De Rosa R., Grosso S., Bruschetta G., et al. Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection. Clin Chim Acta 2010, 411:1137-1142.
    • (2010) Clin Chim Acta , vol.411 , pp. 1137-1142
    • De Rosa, R.1    Grosso, S.2    Bruschetta, G.3
  • 18
    • 33745094071 scopus 로고    scopus 로고
    • Testing by Sysmex UF-100 flow cytometer and with bacterial culture in a diagnostic laboratory: a comparison
    • Evans R., Davidson M.M., Sim L.R., Hay A.J. Testing by Sysmex UF-100 flow cytometer and with bacterial culture in a diagnostic laboratory: a comparison. J Clin Pathol 2006, 59:661-662.
    • (2006) J Clin Pathol , vol.59 , pp. 661-662
    • Evans, R.1    Davidson, M.M.2    Sim, L.R.3    Hay, A.J.4
  • 19
    • 57349172044 scopus 로고    scopus 로고
    • Improving the efficiency and efficacy of pre-analytical and analytical work-flow of urine cultures with urinary flow cytometry
    • Grosso S., Bruschetta G., De Rosa R., Avolio M., Camporese A. Improving the efficiency and efficacy of pre-analytical and analytical work-flow of urine cultures with urinary flow cytometry. New Microbiol 2008, 31:501-505.
    • (2008) New Microbiol , vol.31 , pp. 501-505
    • Grosso, S.1    Bruschetta, G.2    De Rosa, R.3    Avolio, M.4    Camporese, A.5
  • 20
    • 78651457177 scopus 로고    scopus 로고
    • UF-1000i flow cytometry is an effective screening method for urine specimens
    • Kadkhoda K., Manickam K., Degagne P., et al. UF-1000i flow cytometry is an effective screening method for urine specimens. Diagn Microbiol Infect Dis 2011, 69:130-136.
    • (2011) Diagn Microbiol Infect Dis , vol.69 , pp. 130-136
    • Kadkhoda, K.1    Manickam, K.2    Degagne, P.3
  • 21
    • 38049031106 scopus 로고    scopus 로고
    • Evaluation of the Sysmex UF-100 urine cell analyzer as a screening test to reduce the need for urine cultures for community-acquired urinary tract infection
    • Kim S.Y., Kim Y.J., Lee S.M., et al. Evaluation of the Sysmex UF-100 urine cell analyzer as a screening test to reduce the need for urine cultures for community-acquired urinary tract infection. Am J Clin Pathol 2007, 128:922-925.
    • (2007) Am J Clin Pathol , vol.128 , pp. 922-925
    • Kim, S.Y.1    Kim, Y.J.2    Lee, S.M.3
  • 22
    • 77949894493 scopus 로고    scopus 로고
    • Automated microscopy, dipsticks and the diagnosis of urinary tract infection
    • Lunn A., Holden S., Boswell T., Watson A.R. Automated microscopy, dipsticks and the diagnosis of urinary tract infection. Arch Dis Child 2010, 95:193-197.
    • (2010) Arch Dis Child , vol.95 , pp. 193-197
    • Lunn, A.1    Holden, S.2    Boswell, T.3    Watson, A.R.4
  • 23
    • 69949108764 scopus 로고    scopus 로고
    • Cutoff values for bacteria and leukocytes for urine flow cytometer Sysmex UF-1000i in urinary tract infections
    • Manoni F., Fornasiero L., Ercolin M., et al. Cutoff values for bacteria and leukocytes for urine flow cytometer Sysmex UF-1000i in urinary tract infections. Diagn Microbiol Infect Dis 2009, 65:103-107.
    • (2009) Diagn Microbiol Infect Dis , vol.65 , pp. 103-107
    • Manoni, F.1    Fornasiero, L.2    Ercolin, M.3
  • 24
    • 0036803126 scopus 로고    scopus 로고
    • Field evaluation of a second-generation cytometer UF-100 in diagnosis of acute urinary tract infections in adult patients
    • Manoni F., Valverde S., Antico F., Salvadego M.M., Giacomini A., Gessoni G. Field evaluation of a second-generation cytometer UF-100 in diagnosis of acute urinary tract infections in adult patients. Clin Microbiol Infect 2002, 8:662-668.
    • (2002) Clin Microbiol Infect , vol.8 , pp. 662-668
    • Manoni, F.1    Valverde, S.2    Antico, F.3    Salvadego, M.M.4    Giacomini, A.5    Gessoni, G.6
  • 26
    • 78049514901 scopus 로고    scopus 로고
    • Diagnosis of bacteriuria and leukocyturia by automated flow cytometry compared with urine culture
    • Pieretti B., Brunati P., Pini B., et al. Diagnosis of bacteriuria and leukocyturia by automated flow cytometry compared with urine culture. J Clin Microbiol 2010, 48:3990-3996.
    • (2010) J Clin Microbiol , vol.48 , pp. 3990-3996
    • Pieretti, B.1    Brunati, P.2    Pini, B.3
  • 27
    • 78951470760 scopus 로고    scopus 로고
    • Evaluation of the Sysmex UF-1000i(R) urine flow cytometer in the diagnostic work-up of suspected urinary tract infection in a Dutch general hospital
    • van der Zwet W.C., Hessels J., Canbolat F., Deckers M.M. Evaluation of the Sysmex UF-1000i(R) urine flow cytometer in the diagnostic work-up of suspected urinary tract infection in a Dutch general hospital. Clin Chem Lab Med 2010, 48:1765-1771.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1765-1771
    • van der Zwet, W.C.1    Hessels, J.2    Canbolat, F.3    Deckers, M.M.4
  • 28
    • 38849091997 scopus 로고    scopus 로고
    • Evaluating the added predictive ability of a new marker: from area under the ROC curve to reclassification and beyond
    • [discussion 207-112]
    • Pencina M.J., D'Agostino R.B., D'Agostino R.B., Vasan R.S. Evaluating the added predictive ability of a new marker: from area under the ROC curve to reclassification and beyond. Stat Med 2008, 27:157-172. [discussion 207-112].
    • (2008) Stat Med , vol.27 , pp. 157-172
    • Pencina, M.J.1    D'Agostino, R.B.2    D'Agostino, R.B.3    Vasan, R.S.4
  • 30
    • 84865776903 scopus 로고    scopus 로고
    • Quantifying the accuracy of a diagnostic test or marker
    • Linnet K., Bossuyt P.M., Moons K.G., Reitsma J.B. Quantifying the accuracy of a diagnostic test or marker. Clin Chem 2012, 58:1292-1301.
    • (2012) Clin Chem , vol.58 , pp. 1292-1301
    • Linnet, K.1    Bossuyt, P.M.2    Moons, K.G.3    Reitsma, J.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.