메뉴 건너뛰기




Volumn 13, Issue 7, 2013, Pages 2499-2516

Mechanomyography sensor development, related signal processing, and applications: A systematic review

Author keywords

Mechanomyography; muscle characteristics assessment; prosthesis control; sensor development; signal processing

Indexed keywords

CLINICAL PRACTICES; ELECTRONIC DATABASE; FUTURE APPLICATIONS; MECHANOMYOGRAPHY; MUSCLE ACTIVITIES; NEUROMUSCULAR DISORDERS; PROSTHESIS CONTROL; SENSOR DEVELOPMENT;

EID: 84879066156     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2013.2255982     Document Type: Article
Times cited : (60)

References (105)
  • 1
    • 84862799596 scopus 로고    scopus 로고
    • The effects of load, flexion, twisting and window size on the stationarity of trunk muscle EMG signals
    • May
    • Y. J. Cho and J. Y. Kim, "The effects of load, flexion, twisting and window size on the stationarity of trunk muscle EMG signals," Int. J. Ind. Ergonom., vol. 42, no. 3, pp. 287-292, May 2012.
    • (2012) Int. J. Ind. Ergonom. , vol.42 , Issue.3 , pp. 287-292
    • Cho, Y.J.1    Kim, J.Y.2
  • 2
    • 84555187464 scopus 로고    scopus 로고
    • Human muscle fascicle behavior in agonist and antagonist isometric contractions
    • Jan.
    • E. M. Simoneau, S. Longo, O. R. Seynnes, and M. V. Narici, "Human muscle fascicle behavior in agonist and antagonist isometric contractions," Muscle Nerve, vol. 45, no. 1, pp. 92-99, Jan. 2012.
    • (2012) Muscle Nerve , vol.45 , Issue.1 , pp. 92-99
    • Simoneau, E.M.1    Longo, S.2    Seynnes, O.R.3    Narici, M.V.4
  • 3
    • 77954125584 scopus 로고    scopus 로고
    • Use of the novel myokinetic stretching technique to ameliorate fibrotic mass in congenital muscular torticollis: An experimenter-blinded study with 1-year follow-up
    • Feb.
    • S.-C. Chon, S.-I. Yoon, and J. H. You, "Use of the novel myokinetic stretching technique to ameliorate fibrotic mass in congenital muscular torticollis: An experimenter-blinded study with 1-year follow-up," J. Back Musculoskelet Rehabil., vol. 23, no. 2, pp. 63-68, Feb. 2010.
    • (2010) J. Back Musculoskelet Rehabil. , vol.23 , Issue.2 , pp. 63-68
    • Chon, S.-C.1    Yoon, S.-I.2    You, J.H.3
  • 4
    • 84864680129 scopus 로고    scopus 로고
    • Son-omyographic responses during voluntary isometric ramp contraction of the human rectus femoris muscle
    • Jul.
    • X. Chen, Y.-P. Zheng, J.-Y. Guo, Z. Zhu, S.-C. Chan, and Z. Zh, "Son-omyographic responses during voluntary isometric ramp contraction of the human rectus femoris muscle," Eur. J. Appl. Physiol., vol. 112, no. 7, pp. 2603-2614, Jul. 2012.
    • (2012) Eur. J. Appl. Physiol. , vol.112 , Issue.7 , pp. 2603-2614
    • Chen, X.1    Zheng, Y.-P.2    Guo, J.-Y.3    Zhu, Z.4    Chan, S.-C.5    Zh, Z.6
  • 5
    • 77954875951 scopus 로고    scopus 로고
    • Feasibility of controlling prosthetic hand using sonomyography signal in real time: Preliminary study
    • J. Shi, Q. Chang, and Y.-P. Zheng, "Feasibility of controlling prosthetic hand using sonomyography signal in real time: Preliminary study," J. Rehabil. Res. Dev., vol. 47, no. 2, pp. 87-98, 2010.
    • (2010) J. Rehabil. Res. Dev. , vol.47 , Issue.2 , pp. 87-98
    • Shi, J.1    Chang, Q.2    Zheng, Y.-P.3
  • 7
    • 80054998072 scopus 로고    scopus 로고
    • MC sensor-A novel method for measurement of muscle tension
    • Sep.
    • S. Dordevič, S. Stančin, A. Meglič, V. Milutinovič, and S. Tomažič, "MC sensor-A novel method for measurement of muscle tension," Sensors, vol. 11, no. 10, pp. 9411-9425, Sep. 2011.
    • (2011) Sensors , vol.11 , Issue.10 , pp. 9411-9425
    • Dordevič, S.1    Stančin, S.2    Meglič, A.3    Milutinovič, V.4    Tomažič, S.5
  • 8
    • 81555205732 scopus 로고    scopus 로고
    • Mechanomyographic activity in the human lateral pterygoid muscle during mandibular movement
    • Jan.
    • N. Kodama, N. Maeda, S. Sakamoto, K. Oki, Y. Yanagi, J.-I. Asaumi, T. Maeda, and S. Minagi, "Mechanomyographic activity in the human lateral pterygoid muscle during mandibular movement," J. Neurosci. Methods, vol. 203, no. 1, pp. 157-162, Jan. 2012.
    • (2012) J. Neurosci. Methods , vol.203 , Issue.1 , pp. 157-162
    • Kodama, N.1    Maeda, N.2    Sakamoto, S.3    Oki, K.4    Yanagi, Y.5    Asaumi, J.-I.6    Maeda, T.7    Minagi, S.8
  • 9
    • 80052046946 scopus 로고    scopus 로고
    • Mechanomyographic responses are not influenced by the innervation zone for the vastus medialis
    • Sep.
    • M. H. Malek and J. W. Coburn, "Mechanomyographic responses are not influenced by the innervation zone for the vastus medialis," Muscle Nerve, vol. 44, no. 3, pp. 424-431, Sep. 2011.
    • (2011) Muscle Nerve , vol.44 , Issue.3 , pp. 424-431
    • Malek, M.H.1    Coburn, J.W.2
  • 10
    • 0035287618 scopus 로고    scopus 로고
    • Changes in surface emg and acoustic myogram parameters during static fatiguing contractions until exhaustion: Influence of elbow joint angles
    • DOI 10.2114/jpa.20.131
    • K. N. Mamaghani, Y. Shimomura, K. Iwanaga, and T. Katsuura, "Changes in surface EMG and acoustic myogram parameters during static fatiguing contractions until exhaustion: Influence of elbow joint angles," J. Physiol. Anthropol. Appl. Human Sci., vol. 20, no. 2, pp. 131-140, Mar. 2001. (Pubitemid 33598081)
    • (2001) Journal of Physiological Anthropology and Applied Human Science , vol.20 , Issue.2 , pp. 131-140
    • Mamaghani, N.K.1    Shimomura, Y.2    Iwanaga, K.3    Katsuura, T.4
  • 11
    • 0023338858 scopus 로고
    • Acoustic signals from frog muscle
    • May
    • D. T. Barry, "Acoustic signals from frog muscle," Biophys. J., vol. 51, no. 5, pp. 769-773, May 1987.
    • (1987) Biophys. J. , vol.51 , Issue.5 , pp. 769-773
    • Barry, D.T.1
  • 12
    • 0023338552 scopus 로고
    • The mechanism of low-frequency sound production in muscle
    • May
    • J. V. Frangioni, T. S. Kwan-Gett, L. E. Dobrunz, and T. A. McMa-hon, "The mechanism of low-frequency sound production in muscle," Biophys. J., vol. 51, no. 5, pp. 775-783, May 1987.
    • (1987) Biophys. J. , vol.51 , Issue.5 , pp. 775-783
    • Frangioni, J.V.1    Kwan-Gett, T.S.2    Dobrunz, L.E.3    McMa-Hon, T.A.4
  • 13
    • 0025075759 scopus 로고
    • Muscle stiffness measured under conditions simulating natural sound production
    • L. E. Dobrunz, D. G. Pelletin, and T. A. McMahon, "Muscle stiffness measured under conditions simulating natural sound production," Biophys. J., vol. 58, no. 2, pp. 557-565. Aug. 1990. (Pubitemid 20249681)
    • (1990) Biophysical Journal , vol.58 , Issue.2 , pp. 557-565
    • Dobrunz, L.E.1    Pelletier, D.G.2    McMahon, T.A.3
  • 14
    • 62649139244 scopus 로고    scopus 로고
    • Surface mechanomyogram reflects length changes in fascicles of human skeletal muscles
    • Y. Yoshitake, Y. Kawakami, H. Kanehisa, and T. Fukunaga, "Surface mechanomyogram reflects length changes in fascicles of human skeletal muscles," Int. J. Sport Health Sci., vol. 3, no. 2005, pp. 280-285, 2005.
    • (2005) Int. J. Sport Health Sci. , vol.3 , Issue.2005 , pp. 280-285
    • Yoshitake, Y.1    Kawakami, Y.2    Kanehisa, H.3    Fukunaga, T.4
  • 15
    • 0000278686 scopus 로고
    • The sounds from single motor units in a contracting muscle
    • Sep.
    • G. Gordon and A. H. S. Holbourn, "The sounds from single motor units in a contracting muscle," J. Physiol., vol. 107, no. 4, pp. 456-464, Sep. 1948.
    • (1948) J. Physiol. , vol.107 , Issue.4 , pp. 456-464
    • Gordon, G.1    Holbourn, A.H.S.2
  • 16
    • 0020582478 scopus 로고
    • Muscle contraction generates discrete sound bursts
    • F. V. Brozovich and G. H. Pollack, "Muscle contraction generates discrete sound bursts," Biophys. J., vol. 41, no. 1, pp. 35-40, Jan. 1983. (Pubitemid 13114319)
    • (1983) Biophysical Journal , vol.41 , Issue.1 , pp. 35-40
    • Brozovich, F.V.1    Pollack, G.H.2
  • 17
    • 0025435221 scopus 로고
    • Muscle sounds are emitted at the resonant frequencies of skeletal muscle
    • DOI 10.1109/10.55644
    • D. T. Barry and N. M. Cole, "Muscle sounds are emitted at the resonant frequencies of skeletal muscle," IEEE Trans. Biomed. Eng., vol. 37, no. 5, pp. 525-531, May 1990. (Pubitemid 20238336)
    • (1990) IEEE Transactions on Biomedical Engineering , vol.37 , Issue.5 , pp. 525-531
    • Barry, D.T.1    Cole, N.M.2
  • 19
    • 0027155822 scopus 로고
    • Muscle sound: Bases for the introduction of a mechanomyographic signal in muscle studies
    • C. Orizio, "Muscle sound: Bases for the introduction of a mechanomyo-graphic signal in muscle studies," Crit Rev. Biomed. Eng., vol. 21, no. 3, pp. 201-243, Mar. 1993. (Pubitemid 23198883)
    • (1993) Critical Reviews in Biomedical Engineering , vol.21 , Issue.3 , pp. 201-243
    • Orizio, C.1
  • 21
    • 29144513816 scopus 로고    scopus 로고
    • Non-invasive characterization of single motor unit electromyographic and mechanomyographic activities in the biceps brachii muscle
    • DOI 10.1016/j.jelekin.2005.02.005, PII S105064110500060X
    • C. Cescon, E. Sguazzi, R. Merletti, and D. Farina, "Non-invasive characterization of single motor unit electromyographic and mechanomyo-graphic activities in the biceps brachii muscle," J. Electromyogr. Kine-siol., vol. 16, no. 1, pp. 17-24, Feb. 2006. (Pubitemid 41815212)
    • (2006) Journal of Electromyography and Kinesiology , vol.16 , Issue.1 , pp. 17-24
    • Cescon, C.1    Sguazzi, E.2    Merletti, R.3    Farina, D.4
  • 22
    • 78650845382 scopus 로고    scopus 로고
    • Two dimensional spatial coherence of the natural vibrations of the biceps brachii muscle generated during voluntary contractions
    • Sep.
    • A. Archer and K. G. Sabra, "Two dimensional spatial coherence of the natural vibrations of the biceps brachii muscle generated during voluntary contractions," in Proc. IEEE 32nd Annu. Int. Conf. Eng. Med. Biol. Soc., Sep. 2010, pp. 170-173.
    • (2010) Proc. IEEE 32nd Annu. Int. Conf. Eng. Med. Biol. Soc , pp. 170-173
    • Archer, A.1    Sabra, K.G.2
  • 23
    • 84155188956 scopus 로고    scopus 로고
    • Propagation direction of natural mechanical oscillations in the biceps brachii muscle during voluntary contraction
    • Feb.
    • A. A. Archer, P. Atangcho, K. G. Sabra, and M. Shinohara, "Propagation direction of natural mechanical oscillations in the biceps brachii muscle during voluntary contraction," J. Electromyogr. Kinesiol., vol. 22, no. 1, pp. 51-59, Feb. 2012.
    • (2012) J. Electromyogr. Kinesiol. , vol.22 , Issue.1 , pp. 51-59
    • Archer, A.A.1    Atangcho, P.2    Sabra, K.G.3    Shinohara, M.4
  • 24
    • 12444284873 scopus 로고    scopus 로고
    • Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii
    • DOI 10.1016/j.jelekin.2004.08.007, PII S105064110400077X
    • T. J. Housh, G. O. Johnson, J. P. Weir, J. T. Cramer, J. W. Coburn, and M. H. Malek, "Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii," J. Electromyogr. Kinesiol., vol. 15, pp. 190-199, 2005. (Pubitemid 40143440)
    • (2005) Journal of Electromyography and Kinesiology , vol.15 , Issue.2 , pp. 190-199
    • Beck, T.W.1    Housh, T.J.2    Johnson, G.O.3    Weir, J.P.4    Cramer, J.T.5    Coburn, J.W.6    Malek, M.H.7
  • 25
    • 41949085904 scopus 로고    scopus 로고
    • Fatigue and the electromechanical efficiency of the vastus medialis and vastus lateralis muscles
    • K. T. Ebersole and D. M. Malek, "Fatigue and the electromechanical efficiency of the vastus medialis and vastus lateralis muscles," J. Athletic Training, vol. 43, no. 2, pp. 152-156, Mar.-Apr. 2008. (Pubitemid 351508029)
    • (2008) Journal of Athletic Training , vol.43 , Issue.2 , pp. 152-156
    • Ebersole, K.T.1    Malek, D.M.2
  • 26
    • 83755184222 scopus 로고    scopus 로고
    • Study on evaluation of muscle conditions using a mechanomyogram sensor
    • Oct.
    • M. Tanaka, T. Okuyama, and K. Saito, "Study on evaluation of muscle conditions using a mechanomyogram sensor," in Proc. IEEE Int. Conf. Syst., Man, Cybern., Oct. 2011, pp. 741-745.
    • (2011) Proc. IEEE Int. Conf. Syst., Man, Cybern , pp. 741-745
    • Tanaka, M.1    Okuyama, T.2    Saito, K.3
  • 27
    • 78651081721 scopus 로고    scopus 로고
    • Spectral properties of electromyographic and mechanomyographic signals during isometric ramp and step contractions in biceps brachii
    • Feb.
    • L. Qi, J. M. Wakeling, A. Green, K. Lambrecht, and M. FergusonPell, "Spectral properties of electromyographic and mechanomyographic signals during isometric ramp and step contractions in biceps brachii," J. Electromyogr. Kinesiol., vol. 21, no. 1, pp. 128-135, Feb. 2011.
    • (2011) J. Electromyogr. Kinesiol. , vol.21 , Issue.1 , pp. 128-135
    • Qi, L.1    Wakeling, J.M.2    Green, A.3    Lambrecht, K.4    Fergusonpell, M.5
  • 28
    • 77956406034 scopus 로고    scopus 로고
    • A novel integrated mechanomyogram-vocalization access solution
    • Oct.
    • N. Alves, T. H. Falk, and T. Chau, "A novel integrated mechanomyogram-vocalization access solution," Med. Eng. Phys., vol. 32, no. 8, pp. 940-944, Oct. 2010.
    • (2010) Med. Eng. Phys. , vol.32 , Issue.8 , pp. 940-944
    • Alves, N.1    Falk, T.H.2    Chau, T.3
  • 30
    • 77952953408 scopus 로고    scopus 로고
    • The effects of accelerometer placement on mechanomyographic amplitude and mean power frequency during cycle ergometry
    • Aug.
    • J. M. Zuniga, T. J. Housh, C. L. Camic, C. R. Hendrix, M. Mielke, R. J. Schmidt, and G. O. Johnson, "The effects of accelerometer placement on mechanomyographic amplitude and mean power frequency during cycle ergometry," J. Electromyogr. Kinesiol., vol. 20, no. 4, pp. 719-725, Aug. 2010.
    • (2010) J. Electromyogr. Kinesiol. , vol.20 , Issue.4 , pp. 719-725
    • Zuniga, J.M.1    Housh, T.J.2    Camic, C.L.3    Hendrix, C.R.4    Mielke, M.5    Schmidt, R.J.6    Johnson, G.O.7
  • 31
    • 78649316666 scopus 로고    scopus 로고
    • Estimation of elbow flexion force during isometric muscle contraction from mechanomyography and electromyogr
    • Nov.
    • W. Youn and J. Kim, "Estimation of elbow flexion force during isometric muscle contraction from mechanomyography and electromyogr.," Med. Biol. Eng. Comput., vol. 48, no. 11, pp. 1149-1157, Nov. 2010.
    • (2010) Med. Biol. Eng. Comput. , vol.48 , Issue.11 , pp. 1149-1157
    • Youn, W.1    Kim, J.2
  • 32
    • 77950689622 scopus 로고    scopus 로고
    • Uncovering chaotic structure in mechanomyography signals of fatigue biceps brachii muscle
    • Apr.
    • H.-B. Xie, J.-Y. Guo, and Y.-P. Zheng, "Uncovering chaotic structure in mechanomyography signals of fatigue biceps brachii muscle," J. Bio-mech., vol. 43, no. 6, pp. 1224-1226, Apr. 2010.
    • (2010) J. Bio-mech. , vol.43 , Issue.6 , pp. 1224-1226
    • Xie, H.-B.1    Guo, J.-Y.2    Zheng, Y.-P.3
  • 34
    • 81855206585 scopus 로고    scopus 로고
    • Mechanomyographic amplitude and mean power frequency versus isometric force relationships detected in two axes
    • Sep.
    • M. A. Dillon, T. W. Beck, J. M. DeFreitas, and M. S. Stock, "Mechanomyographic amplitude and mean power frequency versus isometric force relationships detected in two axes," Clin Kinesiol., vol. 65, pp. 47-57, Sep. 2011.
    • (2011) Clin Kinesiol. , vol.65 , pp. 47-57
    • Dillon, M.A.1    Beck, T.W.2    Defreitas, J.M.3    Stock, M.S.4
  • 35
    • 76249133505 scopus 로고    scopus 로고
    • Cross-correlation analysis of mechanomyographic signals detected in two axes
    • Dec.
    • T. W. Beck, A. D. Michael, M. D. Jason, and S. S. Matt, "Cross-correlation analysis of mechanomyographic signals detected in two axes," Physiol. Meas., vol. 30, no. 12, pp. 1465-1471, Dec. 2009.
    • (2009) Physiol. Meas. , vol.30 , Issue.12 , pp. 1465-1471
    • Beck, T.W.1    Michael, A.D.2    Jason, M.D.3    Matt, S.S.4
  • 36
    • 54049084518 scopus 로고    scopus 로고
    • Muscle-joint unit transfer function derived from torque and surface mechanomyogram in humans using different stimulation protocols
    • Aug.
    • C. Orizio, M. Solomonow, B. Diemont, and M. Gobbo, "Muscle-joint unit transfer function derived from torque and surface mechanomyogram in humans using different stimulation protocols," J. Neurosci. Methods, vol. 173, no. 1, pp. 59-66, Aug. 2008.
    • (2008) J. Neurosci. Methods , vol.173 , Issue.1 , pp. 59-66
    • Orizio, C.1    Solomonow, M.2    Diemont, B.3    Gobbo, M.4
  • 38
    • 84861671404 scopus 로고    scopus 로고
    • Twitch parameters in transversal and longitudinal biceps brachii response
    • Sep.
    • B. Šimunič, D. Križaj, M. Narici, and R. Pišot, "Twitch parameters in transversal and longitudinal biceps brachii response," Ann. Kinesiol., vol. 1, pp. 61-80, Sep. 2010.
    • (2010) Ann. Kinesiol. , vol.1 , pp. 61-80
    • Šimunič, B.1    Križaj, D.2    Narici, M.3    Pišot, R.4
  • 39
    • 26444620084 scopus 로고    scopus 로고
    • Spatial fiber type distribution in normal human muscle: Histochemical and tensiomyographical evaluation
    • DOI 10.1016/j.jbiomech.2004.10.020, PII S0021929004005147
    • R. Dahmane, S. Djordjevic, B. Šimunič, and V. Valencic, "Spatial fiber type distribution in normal human muscle Histochemical and tensiomyographical evaluation," J. Biomech., vol. 38, no. 12, pp. 2451-2459, Dec. 2005. (Pubitemid 41427239)
    • (2005) Journal of Biomechanics , vol.38 , Issue.12 , pp. 2451-2459
    • Dahmane, R.1    Djordjevic, S.2    Simunic, B.3    Valencic, V.4
  • 40
    • 74449093360 scopus 로고    scopus 로고
    • Mechanomyog-raphy is more sensitive than EMG in detecting age-related sarcopenia
    • Feb.
    • S.-L. Tian, Y. Liu, L. Li, W.-J. Fu, and C.-H. Peng, "Mechanomyog- raphy is more sensitive than EMG in detecting age-related sarcopenia," J. Biomech., vol. 43, no. 3, pp. 551-556, Feb. 2010.
    • (2010) J. Biomech. , vol.43 , Issue.3 , pp. 551-556
    • Tian, S.-L.1    Liu, Y.2    Li, L.3    Fu, W.-J.4    Peng, C.-H.5
  • 41
    • 68949194327 scopus 로고    scopus 로고
    • EMG and MMG activities of agonist and antagonist muscles in Parkinson's disease patients during absolute submaximal load holding
    • Oct.
    • J. Marusiak, A. Jaskólska, K. Kisiel-Sajewicz, G. H. Yue, and A. Jaskól-ski, "EMG and MMG activities of agonist and antagonist muscles in Parkinson's disease patients during absolute submaximal load holding," J. Electromyogr. Kinesiol., vol. 19, no. 5, pp. 903-914, Oct. 2009.
    • (2009) J. Electromyogr. Kinesiol. , vol.19 , Issue.5 , pp. 903-914
    • Marusiak, J.1    Jaskólska, A.2    Kisiel-Sajewicz, K.3    Yue, G.H.4    Jaskól-Ski, A.5
  • 42
    • 34249797900 scopus 로고    scopus 로고
    • The mechanomyography of persons after stroke during isometric voluntary contractions
    • DOI 10.1016/j.jelekin.2006.01.015, PII S1050641106000332
    • X. L. Hu, K. Y. Tong, and L. Li, "The mechanomyography of persons after stroke during isometric voluntary contractions," J. Electromyogr. Kinesiol., vol. 17, no. 4, pp. 473-483, Aug. 2007. (Pubitemid 46856872)
    • (2007) Journal of Electromyography and Kinesiology , vol.17 , Issue.4 , pp. 473-483
    • Hu, X.L.1    Tong, K.Y.2    Li, L.3
  • 44
    • 51349104800 scopus 로고    scopus 로고
    • Longitudinal and transverse propagation of surface mechanomyographic waves generated by single motor unit activity
    • Sep.
    • C. Cescon, P. Madeleine, and D. Farina, "Longitudinal and transverse propagation of surface mechanomyographic waves generated by single motor unit activity," Med. Biol. Eng. Comput., vol. 46, no. 9, pp. 871-877, Sep. 2008.
    • (2008) Med. Biol. Eng. Comput. , vol.46 , Issue.9 , pp. 871-877
    • Cescon, C.1    Madeleine, P.2    Farina, D.3
  • 45
    • 27844471531 scopus 로고    scopus 로고
    • Mechanomyographic response to transcranial magnetic stimulation from biceps brachii and during transcutaneous electrical nerve stimulation on extensor carpi radialis
    • DOI 10.1016/j.jneumeth.2005.05.013, PII S0165027005001883
    • M. F. Reza, K. Ikoma, T. Chuma, and Y. Mano, "Mechanomyographic response to transcranial magnetic stimulation from biceps brachii and during transcutaneous electrical nerve stimulation on extensor carpi radialis," J. Neurosci. Methods, vol. 149, no. 2, pp. 164-171, Dec. 2005. (Pubitemid 41642583)
    • (2005) Journal of Neuroscience Methods , vol.149 , Issue.2 , pp. 164-171
    • Reza, M.F.1    Ikoma, K.2    Chuma, T.3    Mano, Y.4
  • 46
    • 80052375023 scopus 로고    scopus 로고
    • Time course of stretching-induced changes in mechanomyogram and force characteristics
    • Oct.
    • F. Esposito, E. Limonta, and E. Cè, "Time course of stretching-induced changes in mechanomyogram and force characteristics," J. Electromyogr. Kinesiol., vol. 21, no. 5, pp. 795-802, Oct. 2011.
    • (2011) J. Electromyogr. Kinesiol. , vol.21 , Issue.5 , pp. 795-802
    • Esposito, F.1    Limonta, E.2    Cè, E.3
  • 48
    • 33751103664 scopus 로고    scopus 로고
    • Effects of graded levels of exercise on ipsilateral and contralateral post-exercise resting rectus femoris mechanomyography
    • DOI 10.1007/s00421-006-0301-y
    • W. P. McKay, P. Jacobson, P. D. Chilibeck, and B. L. Daku, "Effects of graded levels of exercise on ipsilateral and contralateral post-exercise resting rectus femoris mechanomyography," Eur. J. Appl. Physiol., vol. 98, no. 6, pp. 566-574, Dec. 2006. (Pubitemid 44762578)
    • (2006) European Journal of Applied Physiology , vol.98 , Issue.6 , pp. 566-574
    • McKay, W.P.S.1    Jacobson, P.2    Chilibeck, P.D.3    Daku, B.L.F.4
  • 50
    • 33645779793 scopus 로고    scopus 로고
    • Comparison of phonomyography, kinemyography and mechanomyog-raphy for neuromuscular monitoring
    • Feb.
    • G. Trager, G. Michaud, S. Deschamps, and T. M. Hemmerling, "Comparison of phonomyography, kinemyography and mechanomyog-raphy for neuromuscular monitoring," Canadian J. Anesthesia, vol. 53, no. 2, pp. 130-135, Feb. 2006.
    • (2006) Canadian J. Anesthesia , vol.53 , Issue.2 , pp. 130-135
    • Trager, G.1    Michaud, G.2    Deschamps, S.3    Hemmerling, T.M.4
  • 51
    • 0345531152 scopus 로고    scopus 로고
    • Surface electromyography and mechanomyography recording: A new differential composite probe
    • DOI 10.1007/BF02349974
    • B. Gregori, E. Galie, and N. Accornero, "Surface electromyography and mechanomyography recording: A new differential composite probe," Med. Biol. Eng. Comput., vol. 41, no. 6, pp. 665-669, Nov. 2003. (Pubitemid 37508730)
    • (2003) Medical and Biological Engineering and Computing , vol.41 , Issue.6 , pp. 665-669
    • Gregori, B.1    Galie, E.2    Accornero, N.3
  • 52
    • 77956025416 scopus 로고    scopus 로고
    • Comparison of mechanomyographic sensors during incremental cycle ergometry for the quadriceps femoris
    • Jan.
    • M. H. Malek, J. W. Coburn, R. York, J. Ng, and S. R. Rana, "Comparison of mechanomyographic sensors during incremental cycle ergometry for the quadriceps femoris," Muscle Nerve, vol. 42, no. 1, pp. 394-400, Jan. 2010.
    • (2010) Muscle Nerve , vol.42 , Issue.1 , pp. 394-400
    • Malek, M.H.1    Coburn, J.W.2    York, R.3    Ng, J.4    Rana, S.R.5
  • 53
    • 84857033975 scopus 로고    scopus 로고
    • The effects of motion artifact on mechanomyography: A comparative study of microphones and accelerometers
    • Apr.
    • A. O. Posatskiy and T. Chau, "The effects of motion artifact on mechanomyography: A comparative study of microphones and accelerometers," J. Electromyogr. Kinesiol., vol. 22, no. 2, pp. 320-324, Apr. 2012.
    • (2012) J. Electromyogr. Kinesiol. , vol.22 , Issue.2 , pp. 320-324
    • Posatskiy, A.O.1    Chau, T.2
  • 54
    • 77954624043 scopus 로고    scopus 로고
    • The effect of accelerometer location on the classification of single-site forearm mechanomyograms
    • Jun.
    • N. Alves, E. Sejdic, B. Sahota, and T. Chau, "The effect of accelerometer location on the classification of single-site forearm mechanomyograms," Biomed. Eng. Online, vol. 9, pp. 1-23, Jun. 2010.
    • (2010) Biomed. Eng. Online , vol.9 , pp. 1-23
    • Alves, N.1    Sejdic, E.2    Sahota, B.3    Chau, T.4
  • 55
    • 38349078432 scopus 로고    scopus 로고
    • Vision-based segmentation of continuous mechanomyographic grasping sequences
    • Feb.
    • N. Alves and T. Chau, "Vision-based segmentation of continuous mechanomyographic grasping sequences," IEEE Trans. Biomed. Eng., vol. 55, no. 2, pp. 765-773, Feb. 2008.
    • (2008) IEEE Trans. Biomed. Eng. , vol.55 , Issue.2 , pp. 765-773
    • Alves, N.1    Chau, T.2
  • 56
    • 77949803085 scopus 로고    scopus 로고
    • Automatic detection of muscle activity from mechanomyogram signals: A comparison of amplitude and wavelet-based methods
    • Apr.
    • N. Alves and T. Chau, "Automatic detection of muscle activity from mechanomyogram signals: A comparison of amplitude and wavelet-based methods," Physiol. Meas., vol. 31, no. 4, pp. 461-476, Apr. 2010.
    • (2010) Physiol. Meas. , vol.31 , Issue.4 , pp. 461-476
    • Alves, N.1    Chau, T.2
  • 57
    • 29944440971 scopus 로고    scopus 로고
    • Mechanomyographic amplitude and frequency responses during dynamic muscle actions: A comprehensive review
    • Dec.
    • T. W. Beck, T. J. Housh, J. T. Cramer, J. P. Weir, G. O. Johnson, J. W. Coburn, M. H. Malek, and M. Mielke, "Mechanomyographic amplitude and frequency responses during dynamic muscle actions: A comprehensive review," Biomed. Eng. Online, vol. 4, no. 1, pp. 1-67, Dec. 2005.
    • (2005) Biomed. Eng. Online , vol.4 , Issue.1 , pp. 1-67
    • Beck, T.W.1    Housh, T.J.2    Cramer, J.T.3    Weir, J.P.4    Johnson, G.O.5    Coburn, J.W.6    Malek, M.H.7    Mielke, M.8
  • 58
    • 48049099906 scopus 로고    scopus 로고
    • Frequency features of mechanomyo-graphic signals of human soleus muscle during quiet standing
    • Aug.
    • M. Kouzaki and T. Fukunaga, "Frequency features of mechanomyo-graphic signals of human soleus muscle during quiet standing," J. Neu-rosci. Methods, vol. 173, no. 2, pp. 241-248, Aug. 2008.
    • (2008) J. Neu-rosci. Methods , vol.173 , Issue.2 , pp. 241-248
    • Kouzaki, M.1    Fukunaga, T.2
  • 59
    • 4344584436 scopus 로고    scopus 로고
    • Mechanomyographic and electromyographic time and frequency domain responses during submaximal to maximal isokinetic muscle actions of the biceps brachii
    • T. W. Beck, T. J. Housh, G. O. Johnson, J. P. Weir, J. T. Cramer, J. W. Coburn, and M. H. Malek, "Mechanomyographic and electromyo-graphic time and frequency domain responses during submaximal to maximal isokinetic muscle actions of the biceps brachii," Eur. J. Appl. Physiol., vol. 92, no. 3, pp. 352-359, 2004. (Pubitemid 39117499)
    • (2004) European Journal of Applied Physiology , vol.92 , Issue.3 , pp. 352-359
    • Beck, T.W.1    Housh, T.J.2    Johnson, G.O.3    Weir, J.P.4    Cramer, J.T.5    Coburn, J.W.6    Malek, M.H.7
  • 60
    • 42949089163 scopus 로고    scopus 로고
    • Stationarity distributions of mechanomyogram signals from isometric contractions of extrinsic hand muscles during functional grasping
    • DOI 10.1016/j.jelekin.2006.11.010, PII S1050641106001842
    • N. Alves and T. Chau, "Stationarity distributions of mechanomyo-gram signals from isometric contractions of extrinsic hand muscles during functional grasping," J. Electromyogr. Kinesiol., vol. 18, no. 3, pp. 509-515, Jun. 2008. (Pubitemid 351615055)
    • (2008) Journal of Electromyography and Kinesiology , vol.18 , Issue.3 , pp. 509-515
    • Alves, N.1    Chau, T.2
  • 61
    • 84855718116 scopus 로고    scopus 로고
    • The utility of electromyography and mechanomyography for assessing neuromuscular function: A noninva-sive approach
    • Feb.
    • M. H. Malek and J. W. Coburn, "The utility of electromyography and mechanomyography for assessing neuromuscular function: A noninva-sive approach," Phys. Med. Rehabil. Clinics North Amer., vol. 23, no. 1, pp. 23-32, Feb. 2012.
    • (2012) Phys. Med. Rehabil. Clinics North Amer. , vol.23 , Issue.1 , pp. 23-32
    • Malek, M.H.1    Coburn, J.W.2
  • 62
    • 33750991073 scopus 로고    scopus 로고
    • Does the frequency content of the surface mechanomyographic signal reflect motor unit firing rates? A brief review
    • DOI 10.1016/j.jelekin.2005.12.002, PII S1050641106000058
    • T. W. Beck, T. J. Housh, G. O. Johnson, J. T. Cramer, J. P. Weir, J. W. Coburn, and M. H. Malek, "Does the frequency content of the surface mechanomyographic signal reflect motor unit firing rates? A brief review," J. Electromyogr. Kinesiol., vol. 17, no. 1, pp. 1-13, Feb. 2007. (Pubitemid 44750700)
    • (2007) Journal of Electromyography and Kinesiology , vol.17 , Issue.1 , pp. 1-13
    • Beck, T.W.1    Housh, T.J.2    Johnson, G.O.3    Cramer, J.T.4    Weir, J.P.5    Coburn, J.W.6    Malek, M.H.7
  • 63
    • 84874898866 scopus 로고    scopus 로고
    • Mechanomyogram for Muscle function assessment: A review
    • Mar.
    • M. A. Islam, K. Sundaraj, R. B. Ahmad, and N. U. Ahamed, "Mechanomyogram for Muscle function assessment: A review," PLoS ONE, vol. 8, no. 3, p. e58902, Mar. 2013.
    • (2013) PLoS ONE , vol.8 , Issue.3
    • Islam, M.A.1    Sundaraj, K.2    Ahmad, R.B.3    Ahamed, N.U.4
  • 65
    • 0038179436 scopus 로고    scopus 로고
    • Systematic characterisation of silicon-embedded accelerometers for mechanomyography
    • DOI 10.1007/BF02348433
    • J. Silva, T. Chau, S. Naumann, and W. Heim, "Systematic characterisation of silicon-embedded accelerometers for mechanomyography," Med. Biol. Eng. Comput., vol. 41, no. 3, pp. 290-295, May 2003. (Pubitemid 36701032)
    • (2003) Medical and Biological Engineering and Computing , vol.41 , Issue.3 , pp. 290-295
    • Silva, J.1    Chau, T.2    Naumann, S.3    Heim, W.4
  • 66
    • 33749532659 scopus 로고    scopus 로고
    • Spatial and force dependency of mechanomyographic signal features
    • DOI 10.1016/j.jneumeth.2006.05.018, PII S0165027006002603
    • P. Madeleine, C. Cescon, and D. Farina, "Spatial and force dependency of mechanomyographic signal features," J. Neurosci. Methods, vol. 158, no. 1, pp. 89-99, Nov. 2006. (Pubitemid 44528766)
    • (2006) Journal of Neuroscience Methods , vol.158 , Issue.1 , pp. 89-99
    • Madeleine, P.1    Cescon, C.2    Farina, D.3
  • 67
    • 34547742108 scopus 로고    scopus 로고
    • Heterogeneous mechanomyographic absolute activation of paraspinal muscles assessed by a two-dimensional array during short and sustained contractions
    • Feb.
    • M. Pascal, T. Kylie, A.-N. Lars, and F. Dario, "Heterogeneous mechanomyographic absolute activation of paraspinal muscles assessed by a two-dimensional array during short and sustained contractions," J. Biomech., vol. 40, pp. 2663-2671, Feb. 2007.
    • (2007) J. Biomech. , vol.40 , pp. 2663-2671
    • Pascal, M.1    Kylie, T.2    Lars, A.-N.3    Dario, F.4
  • 68
    • 0037356499 scopus 로고    scopus 로고
    • Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions
    • DOI 10.1007/BF02344888
    • M. Watakabe, K. Mita, K. Akataki, and K. Ito, "Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions," Med. Biol. Eng. Comput., vol. 41, no. 2, pp. 198-202, Mar. 2003. (Pubitemid 36411145)
    • (2003) Medical and Biological Engineering and Computing , vol.41 , Issue.2 , pp. 198-202
    • Watakabe, M.1    Mita, K.2    Akataki, K.3    Ito, K.4
  • 69
    • 34047161520 scopus 로고    scopus 로고
    • A comparison between mechanomyographic condenser microphone and accelerometer measurements during submaximal isometric, concentric and eccentric contractions
    • DOI 10.1016/j.jelekin.2006.04.002, PII S1050641106000447
    • A. Jaskolska, P. Madeleine, A. Jaskolski, K. Kisiel-Sajewicz, and L. Arendt-Nielsen, "A comparison between mechanomyographic condenser microphone and accelerometer measurements during submaximal isometric, concentric and eccentric contractions," J. Electromyogr. Kinesiol., vol. 17, no. 3, pp. 336-347, Jun. 2007. (Pubitemid 46529488)
    • (2007) Journal of Electromyography and Kinesiology , vol.17 , Issue.3 , pp. 336-347
    • Jaskolska, A.1    Madeleine, P.2    Jaskolski, A.3    Kisiel-Sajewicz, K.4    Arendt-Nielsen, L.5
  • 70
    • 33745183110 scopus 로고    scopus 로고
    • Comparison of a piezoelectric contact sensor and an accelerometer for examining mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii
    • Aug.
    • T. W. Beck, T. J. Housh, G. O. Johnson, J. P. Weir, J. T. Cramer, J. W. Coburn, and M. H. Malek, "Comparison of a piezoelectric contact sensor and an accelerometer for examining mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii," J. Elec-tromyogr. Kinesiol., vol. 16, no. 4, pp. 324-335, Aug. 2006.
    • (2006) J. Elec-tromyogr. Kinesiol. , vol.16 , Issue.4 , pp. 324-335
    • Beck, T.W.1    Housh, T.J.2    Johnson, G.O.3    Weir, J.P.4    Cramer, J.T.5    Coburn, J.W.6    Malek, M.H.7
  • 71
    • 63449091830 scopus 로고    scopus 로고
    • Concentric and eccentric isokinetic muscle activity separated by paired pattern classification of wavelet transformed mechanomyograms
    • T. W. Beck and V. von Tscharner, "Concentric and eccentric isokinetic muscle activity separated by paired pattern classification of wavelet transformed mechanomyograms," Biomed. Signal Process. Control, vol. 4, no. 2, pp. 94-101, 2009.
    • (2009) Biomed. Signal Process. Control , vol.4 , Issue.2 , pp. 94-101
    • Beck, T.W.1    Von Tscharner, V.2
  • 72
    • 67651166904 scopus 로고    scopus 로고
    • Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition for multifunction prosthesis control
    • May
    • H.-B. Xie, Y.-P. Zheng, and J.-Y. Guo, "Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition for multifunction prosthesis control," Physiol. Meas., vol. 30, no. 5, p. 441, May 2009.
    • (2009) Physiol. Meas. , vol.30 , Issue.5 , pp. 441
    • Xie, H.-B.1    Zheng, Y.-P.2    Guo, J.-Y.3
  • 73
    • 33745434083 scopus 로고    scopus 로고
    • Torque and surface mechanomyogram parallel reduction during fatiguing stimulation in human muscles
    • DOI 10.1007/s00421-006-0134-8
    • M. Gobbo, E. Ce, B. Diemont, F. Esposito, and C. Orizio, "Torque and surface mechanomyogram parallel reduction during fatiguing stimulation in human muscles," Eur. J. Appl. Physiol., vol. 97, no. 1, pp. 9-15, May 2006. (Pubitemid 43949782)
    • (2006) European Journal of Applied Physiology , vol.97 , Issue.1 , pp. 9-15
    • Gobbo, M.1    Ce, E.2    Diemont, B.3    Esposito, F.4    Orizio, C.5
  • 75
    • 72049131540 scopus 로고    scopus 로고
    • Muscle fatigue assessment by mechanomyography during application of NMES protocol
    • L. Faller, G. N. Nogueira Neto, V. L. S. N. Button, and P. Nohama, "Muscle fatigue assessment by mechanomyography during application of NMES protocol," Revista Brasileira De Fisioterapia, vol. 13, no. 5, pp. 422-429, 2009.
    • (2009) Revista Brasileira de Fisioterapia , vol.13 , Issue.5 , pp. 422-429
    • Faller, L.1    Nogueira Neto, G.N.2    Button, V.L.S.N.3    Nohama, P.4
  • 76
    • 78649500268 scopus 로고    scopus 로고
    • Comparing electromyographic and mechanomyo-graphic frequency-based fatigue thresholds to critical torque during isometric forearm flexion
    • Jul.
    • C. R. Hendrix, T. J. Housh, C. L. Camic, J. M. Zuniga, G. O. Johnson, and R. J. Schmidt, "Comparing electromyographic and mechanomyo-graphic frequency-based fatigue thresholds to critical torque during isometric forearm flexion," J. Neurosci. Methods, vol. 194, no. 1, pp. 64-72, Jul. 2010.
    • (2010) J. Neurosci. Methods , vol.194 , Issue.1 , pp. 64-72
    • Hendrix, C.R.1    Housh, T.J.2    Camic, C.L.3    Zuniga, J.M.4    Johnson, G.O.5    Schmidt, R.J.6
  • 78
    • 80052345201 scopus 로고    scopus 로고
    • Wavelet-based intensity analysis of mechanomyo-graphic signals during single-legged stance following fatigue
    • Oct.
    • W. J. Armstrong, "Wavelet-based intensity analysis of mechanomyo-graphic signals during single-legged stance following fatigue," J. Elec-tromyogr. Kinesiol., vol. 21, no. 5, pp. 803-810, Oct. 2011.
    • (2011) J. Elec-tromyogr. Kinesiol. , vol.21 , Issue.5 , pp. 803-810
    • Armstrong, W.J.1
  • 79
    • 33745499257 scopus 로고    scopus 로고
    • Mechanomyogram and electromyogram analyses for investigating human masseter muscle fatigue
    • DOI 10.1016/j.odw.2005.12.002, PII S1344024106000069
    • H. Ioi, M. Kawakatsu, S. Nakata, A. Nakasima, and A. L. Counts, "Mechanomyogram and electromyogram analyses for investigating human masseter muscle fatigue," Orthodontic Waves, vol. 65, no. 6, pp. 15-20, 2006. (Pubitemid 43963693)
    • (2006) Orthodontic Waves , vol.65 , Issue.1 , pp. 15-20
    • Ioi, H.1    Kawakatsu, M.2    Nakata, S.3    Nakasima, A.4    Counts, A.L.5
  • 80
    • 45849116557 scopus 로고    scopus 로고
    • Short-term repeatability of parameters extracted from radial displacement of muscle belly
    • DOI 10.1016/j.jelekin.2007.01.008, PII S1050641107000077
    • D. Križaj, B. Šimunič, and T. Zagar, "Short-term repeatability of parameters extracted from radial displacement of muscle belly," J. Electromyogr. Kinesiol., vol. 18, no. 4, pp. 645-651, Aug. 2008. (Pubitemid 351885327)
    • (2008) Journal of Electromyography and Kinesiology , vol.18 , Issue.4 , pp. 645-651
    • Krizaj, D.1    Simunic, B.2    Zagar, T.3
  • 82
    • 67349122633 scopus 로고    scopus 로고
    • Within-day and between-days reliability of quadriceps isometric muscle fatigue using mechanomyography on healthy subjects
    • Aug.
    • E. Al-Zahrani, C. Gunasekaran, M. Callaghan, P. Gaydecki, D. Benitez, and J. Oldham, "Within-day and between-days reliability of quadriceps isometric muscle fatigue using mechanomyography on healthy subjects," J. Electromyogr. Kinesiol., vol. 19, no. 4, pp. 695-703, Aug. 2009.
    • (2009) J. Electromyogr. Kinesiol. , vol.19 , Issue.4 , pp. 695-703
    • Al-Zahrani, E.1    Gunasekaran, C.2    Callaghan, M.3    Gaydecki, P.4    Benitez, D.5    Oldham, J.6
  • 85
    • 33947522862 scopus 로고    scopus 로고
    • Inter-individual variability in the torque-related patterns of responses for mechanomyographic amplitude and mean power frequency
    • DOI 10.1016/j.jneumeth.2006.11.007, PII S0165027006005681
    • E. D. Ryan, J. T. Cramer, T. J. Housh, T. W. Beck, T. J. Herda, and M. J. Hartman, "Inter-individual variability in the torque-related patterns of responses for mechanomyographic amplitude and mean power frequency," J. Neurosci. Methods, vol. 161, no. 2, pp. 212-219, Apr. 2007. (Pubitemid 46466947)
    • (2007) Journal of Neuroscience Methods , vol.161 , Issue.2 , pp. 212-219
    • Ryan, E.D.1    Cramer, J.T.2    Housh, T.J.3    Beck, T.W.4    Herda, T.J.5    Hartman, M.J.6
  • 86
    • 22544469978 scopus 로고    scopus 로고
    • Strength and endurance of knee extensors in subjects after paralytic poliomyelitis
    • DOI 10.1080/09638280400020623
    • K. Grabljevec, H. Burger, K. Kersevan, V. Valencic, and C. Marincek, "Strength and endurance of knee extensors in subjects after paralytic poliomyelitis," Disabil. Rehabil., vol. 27, no. 14, pp. 791-799, Jul. 2005. (Pubitemid 41015518)
    • (2005) Disability and Rehabilitation , vol.27 , Issue.14 , pp. 791-799
    • Grabljevec, K.1    Burger, H.2    Kersevan, K.3    Valencic, V.4    Marincek, C.5
  • 87
    • 40449097636 scopus 로고    scopus 로고
    • Influence of force tremor on mechanomyographic signals recorded with an accelerometer and a condenser microphone during measurement of agonist and antagonist muscles in voluntary submaximal isometric contractions
    • T.-K. Kim, Y. Shimomura, K. Iwanaga, and T. Katsuura, "Influence of force tremor on mechanomyographic signals recorded with an accelerometer and a condenser microphone during measurement of agonist and antagonist muscles in voluntary submaximal isometric contractions," J. Physiol. Anthropol., vol. 27, no. 1, pp. 33-42, 2008.
    • (2008) J. Physiol. Anthropol. , vol.27 , Issue.1 , pp. 33-42
    • Kim, T.-K.1    Shimomura, Y.2    Iwanaga, K.3    Katsuura, T.4
  • 88
    • 77950338130 scopus 로고    scopus 로고
    • An examination of crosstalk among surface mechanomyographic signals from the superficial quadriceps femoris muscles during isometric muscle actions
    • Apr.
    • T. W. Beck, J. M. DeFreitas, and M. S. Stock, "An examination of crosstalk among surface mechanomyographic signals from the superficial quadriceps femoris muscles during isometric muscle actions," Human Movement Sci., vol. 29, no. 2, pp. 165-171, Apr. 2010.
    • (2010) Human Movement Sci. , vol.29 , Issue.2 , pp. 165-171
    • Beck, T.W.1    Defreitas, J.M.2    Stock, M.S.3
  • 89
    • 4043142170 scopus 로고    scopus 로고
    • Mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii
    • DOI 10.1016/j.jelekin.2004.03.001, PII S1050641104000264
    • T. W. Beck, T. J. Housh, G. O. Johnson, J. P. Weir, J. T. Cramer, J. W. Coburn, and M. H. Malek, "Mechanomyographic amplitude and mean power frequency versus torque relationships during isokinetic and isometric muscle actions of the biceps brachii," J. Electromyogr. Kinesiol., vol. 14, no. 5, pp. 555-564, 2004. (Pubitemid 39061147)
    • (2004) Journal of Electromyography and Kinesiology , vol.14 , Issue.5 , pp. 555-564
    • Beck, T.W.1    Housh, T.J.2    Johnson, G.O.3    Weir, J.P.4    Cramer, J.T.5    Coburn, J.W.6    Malek, M.H.7
  • 92
    • 69249232545 scopus 로고    scopus 로고
    • Effects of age and stimulus on submental mechanomyography signals during swallowing
    • Sep.
    • J. Lee, T. Chau, and C. Steele, "Effects of age and stimulus on submental mechanomyography signals during swallowing," Dysphagia, vol. 24, no. 3, pp. 265-273, Sep. 2009.
    • (2009) Dysphagia , vol.24 , Issue.3 , pp. 265-273
    • Lee, J.1    Chau, T.2    Steele, C.3
  • 93
    • 78149332451 scopus 로고    scopus 로고
    • Linearity and reliability of the mechanomyographic amplitude versus dynamic constant external resistance relationships for the biceps brachii
    • Sep.
    • M. S. Stock, T. W. Beck, J. M. DeFreitas, and M. A. Dillon, "Linearity and reliability of the mechanomyographic amplitude versus dynamic constant external resistance relationships for the biceps brachii," Physiol. Meas., vol. 31, no. 11, p. 1487, Sep. 2010.
    • (2010) Physiol. Meas. , vol.31 , Issue.11 , pp. 1487
    • Stock, M.S.1    Beck, T.W.2    Defreitas, J.M.3    Dillon, M.A.4
  • 94
    • 34249284836 scopus 로고    scopus 로고
    • Mechanomyographic assessment of contractile properties within seven segments of the human deltoid muscle
    • DOI 10.1007/s00421-007-0397-8
    • M. L. Gorelick and J. M. Brown, "Mechanomyographic assessment of contractile properties within seven segments of the human deltoid muscle," Eur. J. Appl. Physiol., vol. 100, no. 1, pp. 35-44, May 2007. (Pubitemid 46805260)
    • (2007) European Journal of Applied Physiology , vol.100 , Issue.1 , pp. 35-44
    • Gorelick, M.L.1    Brown, J.M.M.2
  • 95
    • 33746444328 scopus 로고    scopus 로고
    • Mechanomyographic measures of muscle contractile properties are influenced by the duration of the stimulatory pulse
    • D. J. McAndrew, N. A. D. Rosser, J. Mark, and M. Brown, "Mechanomyographic measures of muscle contractile properties are influenced by the duration of the stimulatory pulse," J. Appl. Res., vol. 6, no. 2, pp. 142-152, 2006. (Pubitemid 44126017)
    • (2006) Journal of Applied Research , vol.6 , Issue.2 , pp. 142-152
    • McAndrew, D.J.1    Rosser, N.A.D.2    Brown, J.M.M.3
  • 96
    • 80054822683 scopus 로고    scopus 로고
    • System identification of the mechanomyogram from single motor units during voluntary isometric contraction
    • Mar.
    • T. Uchiyama and E. Hashimoto, "System identification of the mechanomyogram from single motor units during voluntary isometric contraction," Med. Biol. Eng. Comput., vol. 49, no. 9, pp. 1035-1043, Mar. 2011.
    • (2011) Med. Biol. Eng. Comput. , vol.49 , Issue.9 , pp. 1035-1043
    • Uchiyama, T.1    Hashimoto, E.2
  • 98
    • 67349223985 scopus 로고    scopus 로고
    • Comparison of mechanomyographic amplitude and mean power frequency for the rectus femoris muscle: Cycle versus knee-extensor ergometry
    • Jun.
    • M. H. Malek, J. W. Coburn, and V. Tedjasaputra, "Comparison of mechanomyographic amplitude and mean power frequency for the rectus femoris muscle: Cycle versus knee-extensor ergometry," J. Neurosci. Methods, vol. 181, no. 1, pp. 89-94, Jun. 2009.
    • (2009) J. Neurosci. Methods , vol.181 , Issue.1 , pp. 89-94
    • Malek, M.H.1    Coburn, J.W.2    Tedjasaputra, V.3
  • 99
    • 84255183047 scopus 로고    scopus 로고
    • Muscle stiffness at different force levels measured with two myotono-metric devices
    • Jan.
    • E. Jarocka, J. Marusiak, M. Kumorek, A. Jaskólska, and A. Jaskólski, "Muscle stiffness at different force levels measured with two myotono-metric devices," Physiol. Meas., vol. 33, no. 1, pp. 65-78, Jan. 2012.
    • (2012) Physiol. Meas. , vol.33 , Issue.1 , pp. 65-78
    • Jarocka, E.1    Marusiak, J.2    Kumorek, M.3    Jaskólska, A.4    Jaskólski, A.5
  • 100
    • 62149126544 scopus 로고    scopus 로고
    • Identification of the occurrence and pattern of masseter muscle activities during sleep using EMG and accelerometer systems
    • Jan.
    • H. Yoshimi, K. Sasaguri, K. Tamaki, and S. Sato, "Identification of the occurrence and pattern of masseter muscle activities during sleep using EMG and accelerometer systems," Head Face Med., vol. 5, no. 1, pp. 1-7, Jan. 2009.
    • (2009) Head Face Med. , vol.5 , Issue.1 , pp. 1-7
    • Yoshimi, H.1    Sasaguri, K.2    Tamaki, K.3    Sato, S.4
  • 101
    • 11844275926 scopus 로고    scopus 로고
    • Experimental muscle pain increases mechanomyographic signal activity during sub-maximal isometric contractions
    • DOI 10.1016/j.jelekin.2004.06.006, PII S1050641104000604
    • P. Madeleine and L. Arendt-Nielsen, "Experimental muscle pain increases mechanomyographic signal activity during sub-maximal isometric contractions," J. Electromyogr. Kinesiol., vol. 15, no. 1, pp. 27-36, Jan. 2005. (Pubitemid 40092041)
    • (2005) Journal of Electromyography and Kinesiology , vol.15 , Issue.1 , pp. 27-36
    • Madeleine, P.1    Arendt-Nielsen, L.2
  • 102
    • 70349333246 scopus 로고    scopus 로고
    • Use of MMG Signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol
    • Jan.
    • M. G. Antonelli, P. Beomonte Zobel, and J. Giacomin, "Use of MMG Signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol," Assist Technol., vol. 21, no. 1, pp. 1-12, Jan. 2009.
    • (2009) Assist Technol. , vol.21 , Issue.1 , pp. 1-12
    • Antonelli, M.G.1    Beomonte Zobel, P.2    Giacomin, J.3
  • 103
    • 77952440930 scopus 로고    scopus 로고
    • The design and testing of a novel mechanomyogram-driven switch controlled by small eyebrow movements
    • May
    • N. Alves and T. Chau, "The design and testing of a novel mechanomyogram-driven switch controlled by small eyebrow movements," J. Neuro Eng. Rehabil., vol. 7, pp. 1-10, May 2010.
    • (2010) J. Neuro Eng. Rehabil. , vol.7 , pp. 1-10
    • Alves, N.1    Chau, T.2
  • 104
    • 78650826016 scopus 로고    scopus 로고
    • Recognition of forearm muscle activity by continuous classification of multi-site mechanomyogram signals
    • Sep.
    • N. Alves and T. Chau, "Recognition of forearm muscle activity by continuous classification of multi-site mechanomyogram signals," in Proc. IEEE 32nd Annu. Int. Conf. Eng. Med. Biol. Soc., Sep. 2010, pp. 3531-3534.
    • (2010) Proc. IEEE 32nd Annu. Int. Conf. Eng. Med. Biol. Soc , pp. 3531-3534
    • Alves, N.1    Chau, T.2
  • 105
    • 0024921922 scopus 로고
    • Wavelets and dilation equations. A brief introduction
    • G. Strang, "Wavelets and Dilation Equations: A brief introduction," SIAM Rev., vol. 31, no. 4, pp. 614-627, Dec. 1989. (Pubitemid 20622817)
    • (1989) SIAM Review , vol.31 , Issue.4 , pp. 614-627
    • Strang Gilbert1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.