메뉴 건너뛰기




Volumn 7, Issue 1, 2010, Pages

The design and testing of a novel mechanomyogram-driven switch controlled by small eyebrow movements

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ALGORITHM; ARTICLE; ARTIFACT; ASSOCIATION; AUTOMATION; BLINKING; COMPUTER INTERFACE; EQUIPMENT DESIGN; EYEBROW; FACE MUSCLE; FEMALE; HEAD MOVEMENT; HUMAN; INSTRUMENTATION; MALE; MOTOR ACTIVITY; MUSCLE CONTRACTION; MYOGRAPHY; PATHOPHYSIOLOGY; PHYSIOLOGY; SIGNAL PROCESSING; SPINAL CORD INJURY; TASK PERFORMANCE; TIME;

EID: 77952440930     PISSN: None     EISSN: 17430003     Source Type: Journal    
DOI: 10.1186/1743-0003-7-22     Document Type: Article
Times cited : (29)

References (37)
  • 1
    • 12244269719 scopus 로고    scopus 로고
    • The efficacy and benefits of environmental control systems for the severely disabled
    • The efficacy and benefits of environmental control systems for the severely disabled. A Craig Y Tran P McIsaac P Boord, Med Sci Monit 2005 11 1 32
    • (2005) Med Sci Monit , vol.11 , Issue.1 , pp. 32
    • Craig, A.1    Tran, Y.2    McIsaac, P.3    Boord, P.4
  • 2
  • 3
    • 0029930336 scopus 로고    scopus 로고
    • Controlling assistive technology with head movements-a review
    • 10.1177/026921559601000202
    • Controlling assistive technology with head movements-a review. E Dymond R Potter, Clin Rehabil 1996 10 2 93 10.1177/026921559601000202
    • (1996) Clin Rehabil , vol.10 , Issue.2 , pp. 93
    • Dymond, E.1    Potter, R.2
  • 4
    • 0037638887 scopus 로고    scopus 로고
    • A novel accelerometer tilt switch device for switch actuation in the patient with profound disability
    • 10.1016/S0003-9993(03)00013-3. 12808551
    • A novel accelerometer tilt switch device for switch actuation in the patient with profound disability. S Perring A Summers EL Jones FJ Bowen K Hart, Arch Phys Med Rehabil 2003 84 6 921 923 10.1016/S0003-9993(03)00013-3 12808551
    • (2003) Arch Phys Med Rehabil , vol.84 , Issue.6 , pp. 921-923
    • Perring, S.1    Summers, A.2    Jones, E.L.3    Bowen, F.J.4    Hart, K.5
  • 5
    • 0034015907 scopus 로고    scopus 로고
    • Controlling mouse pointer position using an infrared head-operated joystick
    • DOI 10.1109/86.830955
    • Controlling mouse pointer position using an infrared head- operatedjoystick. DG Evans R Drew P Blenkhorn, IEEE Trans Rehab Eng 2000 8 1 107 117 10.1109/86.830955 (Pubitemid 30230145)
    • (2000) IEEE Transactions on Rehabilitation Engineering , vol.8 , Issue.1 , pp. 107-117
    • Evans, D.G.1    Drew, R.2    Blenkhorn, P.3
  • 6
    • 0029829077 scopus 로고    scopus 로고
    • Freedom through a single switch: Coping and communicating with artificial ventilation
    • 10.1016/0022-510X(96)00086-X. 8899673
    • Freedom through a single switch: coping and communicating with artificial ventilation. P Gryfe I Kurtz M Gutmann G Laiken, J Neurol Sci 1996 139 Suppl 132 133 10.1016/0022-510X(96)00086-X 8899673
    • (1996) J Neurol Sci , vol.139 , Issue.SUPPL. , pp. 132-133
    • Gryfe, P.1    Kurtz, I.2    Gutmann, M.3    Laiken, G.4
  • 7
    • 32844467093 scopus 로고    scopus 로고
    • Application of facial electromyography in computer mouse access for people with disabilities
    • 10.1080/09638280500158349. 16467058
    • Application of facial electromyography in computer mouse access for people with disabilities. CN Huang CH Chen HY Chung, Disabil Rehabil 2006 28 4 231 237 10.1080/09638280500158349 16467058
    • (2006) Disabil Rehabil , vol.28 , Issue.4 , pp. 231-237
    • Huang, C.N.1    Chen, C.H.2    Chung, H.Y.3
  • 8
    • 34547320405 scopus 로고    scopus 로고
    • Persons with multiple disabilities and minimal motor behavior using small forehead movements and new microswitch technology to control environmental stimuli
    • 10.2466/PMS.104.3.870-878. 17688142
    • Persons with multiple disabilities and minimal motor behavior using small forehead movements and new microswitch technology to control environmental stimuli. GE Lancioni MF O'Reilly NN Singh J Sigafoos R Didden D Oliva G Montironi, Percept Mot Skills 2007 104 3 Pt 1 870 878 10.2466/PMS.104.3.870-878 17688142
    • (2007) Percept Mot Skills , vol.104 , Issue.PART 1 , pp. 870-878
    • Lancioni, G.E.1    O'Reilly, M.F.2    Singh, N.N.3    Sigafoos, J.4    Didden, R.5    Oliva, D.6    Montironi, G.7
  • 9
    • 77449138886 scopus 로고    scopus 로고
    • A multiple camera tongue switch for a child with severe spastic quadriplegic cerebral palsy
    • 10.3109/17483100903254561
    • A multiple camera tongue switch for a child with severe spastic quadriplegic cerebral palsy. B Leung T Chau, Disability & Rehabilitation: Assistive Technology 2010 5 1 58 10.3109/17483100903254561
    • (2010) Disability & Rehabilitation: Assistive Technology , vol.5 , Issue.1 , pp. 58
    • Leung, B.1    Chau, T.2
  • 10
    • 65149102628 scopus 로고    scopus 로고
    • Infrared thermography as an access pathway for individuals with severe motor impairments
    • 10.1186/1743-0003-6-11. 19371440
    • Infrared thermography as an access pathway for individuals with severe motor impairments. N Memarian AN Venetsanopoulos T Chau, J Neuroeng Rehabil 2009 6 11 10.1186/1743-0003-6-11 19371440
    • (2009) J Neuroeng Rehabil , vol.6 , pp. 11
    • Memarian, N.1    Venetsanopoulos, A.N.2    Chau, T.3
  • 11
    • 0025435221 scopus 로고
    • Muscle sounds are emitted at the resonant frequencies of skeletal muscle
    • 10.1109/10.55644. 2345010
    • Muscle sounds are emitted at the resonant frequencies of skeletal muscle. DT Barry NM Cole, IEEE Trans Biomed Eng 1990 37 5 525 531 10.1109/10.55644 2345010
    • (1990) IEEE Trans Biomed Eng , vol.37 , Issue.5 , pp. 525-531
    • Barry, D.T.1    Cole, N.M.2
  • 12
    • 0027155822 scopus 로고
    • Muscle sound: Bases for the introduction of a mechanomyographic signal in muscle studies
    • 8243092
    • Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. C Orizio, Crit Rev Biomed Eng 1993 21 3 201 243 8243092
    • (1993) Crit Rev Biomed Eng , vol.21 , Issue.3 , pp. 201-243
    • Orizio, C.1
  • 13
    • 0025341883 scopus 로고
    • Spectral analysis of muscular sound during isometric contraction of biceps brachii
    • 2318762
    • Spectral analysis of muscular sound during isometric contraction of biceps brachii. C Orizio R Perini B Diemont M Maranzana Figini A Veicsteinas, J Appl Physiol 1990 68 2 508 512 2318762
    • (1990) J Appl Physiol , vol.68 , Issue.2 , pp. 508-512
    • Orizio, C.1    Perini, R.2    Diemont, B.3    Maranzana Figini, M.4    Veicsteinas, A.5
  • 14
    • 42949089163 scopus 로고    scopus 로고
    • Stationarity distributions of mechanomyogram signals from isometric contractions of extrinsic hand muscles during functional grasping
    • 10.1016/j.jelekin.2006.11.010. 17276085
    • Stationarity distributions of mechanomyogram signals from isometric contractions of extrinsic hand muscles during functional grasping. N Alves T Chau, J Electromyogr Kinesiol 2008 18 3 509 515 10.1016/j.jelekin.2006.11.010 17276085
    • (2008) J Electromyogr Kinesiol , vol.18 , Issue.3 , pp. 509-515
    • Alves, N.1    Chau, T.2
  • 15
    • 0025814573 scopus 로고
    • Muscle sounds from evoked twitches in the hand
    • 2059135
    • Muscle sounds from evoked twitches in the hand. DT Barry, Arch Phys Med Rehabil 1991 72 8 573 575 2059135
    • (1991) Arch Phys Med Rehabil , vol.72 , Issue.8 , pp. 573-575
    • Barry, D.T.1
  • 16
    • 0031593989 scopus 로고    scopus 로고
    • Technical aspects of mechanomyography recording with piezoelectric contact sensor
    • 10.1007/BF02524423. 10367437
    • Technical aspects of mechanomyography recording with piezoelectric contact sensor. M Watakabe Y Itoh K Mita K Akataki, Med Biol Eng Comput 1998 36 5 557 561 10.1007/BF02524423 10367437
    • (1998) Med Biol Eng Comput , vol.36 , Issue.5 , pp. 557-561
    • Watakabe, M.1    Itoh, Y.2    Mita, K.3    Akataki, K.4
  • 17
    • 0026515677 scopus 로고
    • Vibrations and sounds from evoked muscle twitches
    • 1541245
    • Vibrations and sounds from evoked muscle twitches. DT Barry, Electromyogr Clin Neurophysiol 1992 32 1-2 35 40 1541245
    • (1992) Electromyogr Clin Neurophysiol , vol.32 , Issue.1-2 , pp. 35-40
    • Barry, D.T.1
  • 18
    • 0033056510 scopus 로고    scopus 로고
    • Force and surface mechanomyogram relationship in cat gastrocnemius
    • 10.1016/S1050-6411(98)00044-3. 10098713
    • Force and surface mechanomyogram relationship in cat gastrocnemius. C Orizio RV Baratta BH Zhou M Solomonow A Veicsteinas, J Electromyogr Kinesiol 1999 9 2 131 140 10.1016/S1050-6411(98)00044-3 10098713
    • (1999) J Electromyogr Kinesiol , vol.9 , Issue.2 , pp. 131-140
    • Orizio, C.1    Baratta, R.V.2    Zhou, B.H.3    Solomonow, M.4    Veicsteinas, A.5
  • 19
    • 11844275926 scopus 로고    scopus 로고
    • Experimental muscle pain increases mechanomyographic signal activity during sub-maximal isometric contractions
    • 10.1016/j.jelekin.2004.06.006. 15642651
    • Experimental muscle pain increases mechanomyographic signal activity during sub-maximal isometric contractions. P Madeleine L Arendt-Nielsen, J Electromyogr Kinesiol 2005 15 1 27 36 10.1016/j.jelekin.2004.06.006 15642651
    • (2005) J Electromyogr Kinesiol , vol.15 , Issue.1 , pp. 27-36
    • Madeleine, P.1    Arendt-Nielsen, L.2
  • 20
    • 33747489576 scopus 로고    scopus 로고
    • Mechanomyography for studying force fluctuations and muscle fatigue
    • 10.1249/00003677-200604000-00004. 16672802
    • Mechanomyography for studying force fluctuations and muscle fatigue. M Shinohara K Sogaard, Exerc Sport Sci Rev 2006 34 2 59 64 10.1249/00003677- 200604000-00004 16672802
    • (2006) Exerc Sport Sci Rev , vol.34 , Issue.2 , pp. 59-64
    • Shinohara, M.1    Sogaard, K.2
  • 21
    • 3042663152 scopus 로고    scopus 로고
    • Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: Effects of the feedback mode
    • 10.1007/s00421-002-0578-4. 12012073
    • Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode. P Madeleine LV Jorgensen K Sogaard L Arendt-Nielsen G Sjogaard, Eur J Appl Physiol 2002 87 1 28 37 10.1007/s00421-002-0578-4 12012073
    • (2002) Eur J Appl Physiol , vol.87 , Issue.1 , pp. 28-37
    • Madeleine, P.1    Jorgensen, L.V.2    Sogaard, K.3    Arendt-Nielsen, L.4    Sjogaard, G.5
  • 22
    • 0025248195 scopus 로고
    • Acoustic and surface EMG diagnosis of pediatric muscle disease
    • 10.1002/mus.880130403. 2355941
    • Acoustic and surface EMG diagnosis of pediatric muscle disease. DT Barry KE Gordon GG Hinton, Muscle Nerve 1990 13 4 286 290 10.1002/mus.880130403 2355941
    • (1990) Muscle Nerve , vol.13 , Issue.4 , pp. 286-290
    • Barry, D.T.1    Gordon, K.E.2    Hinton, G.G.3
  • 23
    • 11044233587 scopus 로고    scopus 로고
    • Electromyographic and mechanomyographic estimation of motor unit activation strategy in voluntary force production
    • 15646006
    • Electromyographic and mechanomyographic estimation of motor unit activation strategy in voluntary force production. K Akataki K Mita M Watakabe, Electromyogr Clin Neurophysiol 2004 44 8 489 496 15646006
    • (2004) Electromyogr Clin Neurophysiol , vol.44 , Issue.8 , pp. 489-496
    • Akataki, K.1    Mita, K.2    Watakabe, M.3
  • 24
    • 26444583925 scopus 로고    scopus 로고
    • A self-contained, mechanomyography-driven externally powered prosthesis
    • 10.1016/j.apmr.2005.03.034. 16213256
    • A self-contained, mechanomyography-driven externally powered prosthesis. J Silva W Heim T Chau, Arch Phys Med Rehabil 2005 86 10 2066 2070 10.1016/j.apmr.2005.03.034 16213256
    • (2005) Arch Phys Med Rehabil , vol.86 , Issue.10 , pp. 2066-2070
    • Silva, J.1    Heim, W.2    Chau, T.3
  • 25
    • 0022587670 scopus 로고
    • Acoustic myography as a control signal for an externally powered prosthesis
    • 3964064
    • Acoustic myography as a control signal for an externally powered prosthesis. DT Barry JA Leonard Jr AJ Gitter RD Ball, Arch Phys Med Rehabil 1986 67 4 267 269 3964064
    • (1986) Arch Phys Med Rehabil , vol.67 , Issue.4 , pp. 267-269
    • Barry, D.T.1    Gitter, A.J.2    Ball, R.D.3
  • 26
    • 70349333246 scopus 로고    scopus 로고
    • Use of MMG signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol
    • 19719058
    • Use of MMG signals for the control of powered orthotic devices: development of a rectus femoris measurement protocol. MG Antonelli PB Zobel J Giacomin, Assist Technol 2009 21 1 1 12 19719058
    • (2009) Assist Technol , vol.21 , Issue.1 , pp. 1-12
    • Antonelli, M.G.1    Zobel, P.B.2    Giacomin, J.3
  • 27
    • 77955172158 scopus 로고    scopus 로고
    • Uncovering patterns of forearm muscle activity using multi-channel mechanomyography
    • (Eprint available online doi:10.1016/j.jelekin.2009.09.003).
    • Uncovering patterns of forearm muscle activity using multi-channel mechanomyography. N Alves T Chau, J Electromyogr Kinesiol (Eprint available online doi:10.1016/j.jelekin.2009.09.003).
    • J Electromyogr Kinesiol
    • Alves, N.1    Chau, T.2
  • 28
    • 67651166904 scopus 로고    scopus 로고
    • Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition for multifunction prosthesis control
    • 10.1088/0967-3334/30/5/002. 19349648
    • Classification of the mechanomyogram signal using a wavelet packet transform and singular value decomposition for multifunction prosthesis control. HB Xie YP Zheng JY Guo, Physiol Meas 2009 30 5 441 457 10.1088/0967-3334/30/5/ 002 19349648
    • (2009) Physiol Meas , vol.30 , Issue.5 , pp. 441-457
    • Xie, H.B.1    Zheng, Y.P.2    Guo, J.Y.3
  • 29
    • 0142185498 scopus 로고    scopus 로고
    • Coupled microphone-accelerometer sensor pair for dynamic noise reduction in MMG signal recording
    • 10.1049/el:20031003
    • Coupled microphone-accelerometer sensor pair for dynamic noise reduction in MMG signal recording. J Silva T Chau, Electronics Letters 2003 39 21 1496 1498 10.1049/el:20031003
    • (2003) Electronics Letters , vol.39 , Issue.21 , pp. 1496-1498
    • Silva, J.1    Chau, T.2
  • 30
    • 0035130676 scopus 로고    scopus 로고
    • Mechanomyography and electromyography force relationships during concentric, isometric and eccentric contractions
    • 10.1016/S1050-6411(00)00044-4. 11228424
    • Mechanomyography and electromyography force relationships during concentric, isometric and eccentric contractions. P Madeleine P Bajaj K Sogaard L Arendt-Nielsen, J Electromyogr Kinesiol 2001 11 2 113 121 10.1016/S1050- 6411(00)00044-4 11228424
    • (2001) J Electromyogr Kinesiol , vol.11 , Issue.2 , pp. 113-121
    • Madeleine, P.1    Bajaj, P.2    Sogaard, K.3    Arendt-Nielsen, L.4
  • 31
    • 77949803085 scopus 로고    scopus 로고
    • Automatic detection of muscle activity from mechanomyogram signals
    • 10.1088/0967-3334/31/4/001. 20182001
    • Automatic detection of muscle activity from mechanomyogram signals. N Alves T Chau, Physiol Meas 2010 31 461 476 10.1088/0967-3334/31/4/001 20182001
    • (2010) Physiol Meas , vol.31 , pp. 461-476
    • Alves, N.1    Chau, T.2
  • 32
    • 77954087758 scopus 로고    scopus 로고
    • Bedside computer access for an individual with severe and multiple disabilities: A case study
    • Bedside computer access for an individual with severe and multiple disabilities: a case study. S Blain P McKeever T Chau, Disability & Rehabilitation: Assistive Technology 2010 00 1 11
    • (2010) Disability & Rehabilitation: Assistive Technology , Issue.0 , pp. 1-11
    • Blain, S.1    McKeever, P.2    Chau, T.3
  • 33
    • 0036871997 scopus 로고    scopus 로고
    • Characteristics of surface mechanomyogram are dependent on development of fusion of motor units in humans
    • 12381762
    • Characteristics of surface mechanomyogram are dependent on development of fusion of motor units in humans. Y Yoshitake M Shinohara H Ue T Moritani, J Appl Physiol 2002 93 5 1744 1752 12381762
    • (2002) J Appl Physiol , vol.93 , Issue.5 , pp. 1744-1752
    • Yoshitake, Y.1    Shinohara, M.2    Ue, H.3    Moritani, T.4
  • 34
    • 0035044091 scopus 로고    scopus 로고
    • Mechanical behaviour of condenser microphone in mechanomyography
    • 10.1007/BF02344804. 11361247
    • Mechanical behaviour of condenser microphone in mechanomyography. M Watakabe K Mita K Akataki Y Itoh, Med Biol Eng Comput 2001 39 2 195 201 10.1007/BF02344804 11361247
    • (2001) Med Biol Eng Comput , vol.39 , Issue.2 , pp. 195-201
    • Watakabe, M.1    Mita, K.2    Akataki, K.3    Itoh, Y.4
  • 35
    • 26844544506 scopus 로고    scopus 로고
    • A Mathematical Model for Source Separation of MMG Signals Recorded with a Coupled Microphone-Accelerometer Sensor Pair
    • 10.1109/TBME.2005.851531. 16189962
    • A Mathematical Model for Source Separation of MMG Signals Recorded With a Coupled Microphone-Accelerometer Sensor Pair. J Silva T Chau, IEEE Trans Biomed Eng 2005 52 9 1493 1501 10.1109/TBME.2005.851531 16189962
    • (2005) IEEE Trans Biomed Eng , vol.52 , Issue.9 , pp. 1493-1501
    • Silva, J.1    Chau, T.2
  • 36
    • 0042664129 scopus 로고    scopus 로고
    • A robust, real-time control scheme for multifunction myoelectric control
    • 10.1109/TBME.2003.813539. 12848352
    • A robust, real-time control scheme for multifunction myoelectric control. K Englehart B Hudgins, IEEE Trans Biomed Eng 2003 50 7 848 854 10.1109/TBME.2003.813539 12848352
    • (2003) IEEE Trans Biomed Eng , vol.50 , Issue.7 , pp. 848-854
    • Englehart, K.1    Hudgins, B.2
  • 37
    • 33750515036 scopus 로고    scopus 로고
    • Myoelectric signal processing for control of powered limb prostheses
    • 10.1016/j.jelekin.2006.08.006. 17045489
    • Myoelectric signal processing for control of powered limb prostheses. P Parker K Englehart B Hudgins, J Electromyogr Kinesiol 2006 16 6 541 548 10.1016/j.jelekin.2006.08.006 17045489
    • (2006) J Electromyogr Kinesiol , vol.16 , Issue.6 , pp. 541-548
    • Parker, P.1    Englehart, K.2    Hudgins, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.