메뉴 건너뛰기




Volumn 27, Issue 6, 2013, Pages e127-e136

Rotationally Stable Screw-Anchor Versus Sliding Hip Screw Plate Systems in Stable Trochanteric Femur Fractures: A Biomechanical Evaluation

Author keywords

Biomechanical testing; Cutout; Helical blade; Hip screw; Migration; Rotationally stable screw anchor; Trochanteric fracture

Indexed keywords

ADULT; AGED; ARTICLE; AXIS; BIOMECHANICS; BONE SCREW; CADAVER; COMPARATIVE EFFECTIVENESS; DEVICE THERAPY; FEMALE; FEMUR NECK; FEMUR TROCHANTERIC FRACTURE; HUMAN; MALE; PRIORITY JOURNAL; RIGIDITY; ROTATION; SURVIVAL; TREATMENT FAILURE;

EID: 84878847641     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318278112a     Document Type: Article
Times cited : (26)

References (39)
  • 1
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of pertrochanteric fractures of the hip
    • Baumgaertner M, Curtin S, Lindskog D, et al. The value of the tip-apex distance in predicting failure of fixation of pertrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058-1056.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1058-1056
    • Baumgaertner, M.1    Curtin, S.2    Lindskog, D.3
  • 2
    • 85184726154 scopus 로고    scopus 로고
    • Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev. 2010;CD000093
    • Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev. 2010;CD000093.
  • 3
    • 40849120848 scopus 로고    scopus 로고
    • Surgical outcome in pertrochanteric femur fracture: the impact of osteoporosis. Comparison between DHS and percutaneous compression plate in German
    • Knobe M, Münker R, Schmidt-Rohlfing B, et al. Surgical outcome in pertrochanteric femur fracture: the impact of osteoporosis. Comparison between DHS and percutaneous compression plate [in German]. Z Orthop Unfall. 2008;146:44-51.
    • (2008) Z Orthop Unfall , vol.146 , pp. 44-51
    • Knobe, M.1    Munker, R.2    Schmidt-Rohlfing, B.3
  • 4
    • 69249222556 scopus 로고    scopus 로고
    • Minimally invasive osteosynthesis in stable trochanteric fractures: a comparative study between Gotfried percutaneous compression plate and Gamma 3 intramedullary nail
    • Varela-Egocheaga JR, Iglesias-Colao R, Suárez-Suárez MA, et al. Minimally invasive osteosynthesis in stable trochanteric fractures: a comparative study between Gotfried percutaneous compression plate and Gamma 3 intramedullary nail. Arch Orthop Trauma Surg. 2009;129:1401-1407.
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 1401-1407
    • Varela-Egocheaga, J.R.1    Iglesias-Colao, R.2    Suarez-Suarez, M.A.3
  • 5
    • 0345451574 scopus 로고    scopus 로고
    • Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw
    • Haynes RC, Pöll RG, Miles AW, et al. Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw. Injury. 1997;28:337-341.
    • (1997) Injury , vol.28 , pp. 337-341
    • Haynes, R.C.1    Poll, R.G.2    Miles, A.W.3
  • 6
    • 67650964082 scopus 로고    scopus 로고
    • Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
    • Kouvidis GK, Sommers MB, Giannoudis PV, et al. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation. J Orthop Surg Res. 2009;4:16.
    • (2009) J Orthop Surg Res , vol.4 , pp. 16
    • Kouvidis, G.K.1    Sommers, M.B.2    Giannoudis, P.V.3
  • 7
    • 0035666280 scopus 로고    scopus 로고
    • Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis
    • Kim WY, Han CH, Park JI, et al. Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis. Int Orthop. 2001;25:360-362.
    • (2001) Int Orthop , vol.25 , pp. 360-362
    • Kim, W.Y.1    Han, C.H.2    Park, J.I.3
  • 8
    • 43849090519 scopus 로고    scopus 로고
    • Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw
    • Al-Munajjed AA, Hammer J, Mayr E, et al. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw. Stud Health Technol Inform. 2008;133:1-10.
    • (2008) Stud Health Technol Inform , vol.133 , pp. 1-10
    • Al-Munajjed, A.A.1    Hammer, J.2    Mayr, E.3
  • 9
    • 33750274358 scopus 로고    scopus 로고
    • First clinical and biomechanical results of the Trochanteric Fixation Nail (TFN)
    • Lenich A, Fierlbeck J, Al-Munajjed A, et al. First clinical and biomechanical results of the Trochanteric Fixation Nail (TFN). Technol Health Care. 2006;14:403-409.
    • (2006) Technol Health Care , vol.14 , pp. 403-409
    • Lenich, A.1    Fierlbeck, J.2    Al-Munajjed, A.3
  • 10
    • 57349085028 scopus 로고    scopus 로고
    • Dutoit c, et al. is a helical shaped implant a superior alternative to the dynamic hip screw for unstable femoral neck fractures? a biomechanical investigation. clin biomech (bristol
    • Windolf M, Braunstein V, Dutoit C, et al. Is a helical shaped implant a superior alternative to the dynamic hip screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol, Avon). 2009;24:59-64.
    • (2009) Avon) , vol.24 , pp. 59-64
    • Windolf, M.1    Braunstein, V.2
  • 11
    • 79955008148 scopus 로고    scopus 로고
    • Is the rotation of the femoral head a potential initiation for cutting out A theoretical and experimental approach
    • Lenich A, Bachmeier S, Prantl L, et al. Is the rotation of the femoral head a potential initiation for cutting out? A theoretical and experimental approach. BMC Musculoskelet Disord. 2011;12:79.
    • (2011) BMC Musculoskelet Disord , vol.12 , pp. 79
    • Lenich, A.1    Bachmeier, S.2    Prantl, L.3
  • 12
    • 79955124195 scopus 로고    scopus 로고
    • Dynamic hip screw versus DHS blade: a biomechanical comparison of the fixation achieved by each implant in bone
    • O'Neill F, Condon F, McGloughlin T, et al. Dynamic hip screw versus DHS blade: a biomechanical comparison of the fixation achieved by each implant in bone. J Bone Joint Surg Br. 2011;93:616-621.
    • (2011) J Bone Joint Surg Br , vol.93 , pp. 616-621
    • Oneill, F.1    Condon, F.2    McGloughlin, T.3
  • 13
    • 79952797372 scopus 로고    scopus 로고
    • Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method
    • Born CT, Karich B, Bauer C, et al. Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method. J Orthop Res. 2011;29:760-766.
    • (2011) J Orthop Res , vol.29 , pp. 760-766
    • Born, C.T.1    Karich, B.2    Bauer, C.3
  • 14
    • 34748904648 scopus 로고    scopus 로고
    • Radiographic outcomes of intertrochanteric hip fractures treated with the trochanteric fixation nail
    • Gardner MJ, Briggs SM, Kopjar B, et al. Radiographic outcomes of intertrochanteric hip fractures treated with the trochanteric fixation nail. Injury. 2007;38:1189-1196.
    • (2007) Injury , vol.38 , pp. 1189-1196
    • Gardner, M.J.1    Briggs, S.M.2    Kopjar, B.3
  • 15
    • 59049089233 scopus 로고    scopus 로고
    • The PFNA proximal femur nail in treatment of unstable proximal femur fractures-3 cases of postoperative perforation of the helical blade into the hip joint
    • Brunner A, Jöckel JA, Babst R. The PFNA proximal femur nail in treatment of unstable proximal femur fractures-3 cases of postoperative perforation of the helical blade into the hip joint. J Orthop Trauma. 2008;22:731-736.
    • (2008) J Orthop Trauma , vol.22 , pp. 731-736
    • Brunner, A.1    Jockel, J.A.2    Babst, R.3
  • 16
    • 0041321380 scopus 로고    scopus 로고
    • Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices
    • Audigé L, Hanson B, Swiontkowski MF. Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices. Int Orthop. 2003;27:197-203.
    • (2003) Int Orthop , vol.27 , pp. 197-203
    • Audige, L.1    Hanson, B.2    Swiontkowski, M.F.3
  • 17
    • 33645286249 scopus 로고    scopus 로고
    • Are short femoral nails superior to the sliding hip screw A meta-analysis of 24 studies involving 3279 fractures
    • Jones HW, Johnston P, Parker M. Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3279 fractures. Int Orthop. 2006;30:69-78.
    • (2006) Int Orthop , vol.30 , pp. 69-78
    • Jones, H.W.1    Johnston, P.2    Parker, M.3
  • 18
    • 0022627713 scopus 로고
    • Evaluation of the Singh index and femoral calcar width as epidemiological methods for measuring bone mass in the femoral neck
    • Cooper C, Barker DJ, Hall AJ. Evaluation of the Singh index and femoral calcar width as epidemiological methods for measuring bone mass in the femoral neck. Clin Radiol. 1986;37:123-125.
    • (1986) Clin Radiol , vol.37 , pp. 123-125
    • Cooper, C.1    Barker, D.J.2    Hall, A.J.3
  • 19
    • 39149129995 scopus 로고    scopus 로고
    • Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database andoutcomes committee
    • Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database andoutcomes committee. J Orthop Trauma. 2007;21(suppl 10):S1-S133.
    • (2007) J Orthop Trauma , vol.21
    • Marsh, J.L.1    Slongo, T.F.2    Agel, J.3
  • 20
    • 80755128919 scopus 로고    scopus 로고
    • Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS and Intertan nail
    • Rupprecht M, Grossterlinden L, Sellenschloh K, et al. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS® and Intertan nail®. Int Orthop. 2011;35:1695-1701.
    • (2011) Int Orthop , vol.35 , pp. 1695-1701
    • Rupprecht, M.1    Grossterlinden, L.2    Sellenschloh, K.3
  • 21
    • 33748159153 scopus 로고    scopus 로고
    • Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation
    • Strauss E, Frank J, Lee J, et al. Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury. 2006;37:984-989.
    • (2006) Injury , vol.37 , pp. 984-989
    • Strauss, E.1    Frank, J.2    Lee, J.3
  • 22
    • 2042421503 scopus 로고    scopus 로고
    • Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: a cadaver study
    • Bong MR, Patel V, Iesaka K, et al. Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: a cadaver study. J Trauma. 2004;56:791-794.
    • (2004) J Trauma , vol.56 , pp. 791-794
    • Bong, M.R.1    Patel, V.2    Iesaka, K.3
  • 23
    • 0023492660 scopus 로고
    • Biomechanical evaluation of anatomic reduction versus medial displacement osteotomy in unstable intertrochanteric fractures
    • Chang WS, Zuckerman JD, Kummer FJ, et al. Biomechanical evaluation of anatomic reduction versus medial displacement osteotomy in unstable intertrochanteric fractures. Clin Orthop Relat Res. 1987;225:141-146.
    • (1987) Clin Orthop Relat Res , vol.225 , pp. 141-146
    • Chang, W.S.1    Zuckerman, J.D.2    Kummer, F.J.3
  • 24
    • 0028967034 scopus 로고
    • Biomechanical comparison of the sliding hip screw and the dome plunger. Effects of material and fixation design
    • Choueka J, Koval KJ, Kummer FJ, et al. Biomechanical comparison of the sliding hip screw and the dome plunger. Effects of material and fixation design. J Bone Joint Surg Br. 1995;77:277-283.
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 277-283
    • Choueka, J.1    Koval, K.J.2    Kummer, F.J.3
  • 25
    • 49649097880 scopus 로고    scopus 로고
    • Minimally invasive screw plates for surgery of unstable intertrochanteric femoral fractures: a biomechanical comparative study. Clin Biomech (Bristol, Avon)
    • Ropars M, Mitton D, Skalli W. Minimally invasive screw plates for surgery of unstable intertrochanteric femoral fractures: a biomechanical comparative study. Clin Biomech (Bristol, Avon). 2008;23:1012-1017.
    • (2008) , vol.23 , pp. 1012-1017
    • Ropars, M.1    Mitton, D.2    Skalli, W.3
  • 26
    • 0025139977 scopus 로고
    • A biomechanical analysis of the sliding hip screw: the question of plate angle
    • Meislin RJ, Zuckerman JD, Kummer FJ, et al. A biomechanical analysis of the sliding hip screw: the question of plate angle. J Orthop Trauma. 1990;4:130-136.
    • (1990) J Orthop Trauma , vol.4 , pp. 130-136
    • Meislin, R.J.1    Zuckerman, J.D.2    Kummer, F.J.3
  • 27
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859-871.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 28
    • 0034991415 scopus 로고    scopus 로고
    • Femoral shortening in intertrochanteric fractures: a comparison between the Medoff sliding plate and the compression hip screw
    • Olsson O, Ceder L, Hauggaard A. Femoral shortening in intertrochanteric fractures: a comparison between the Medoff sliding plate and the compression hip screw. J Bone Joint Surg Br. 2001;83:572-578.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 572-578
    • Olsson, O.1    Ceder, L.2    Hauggaard, A.3
  • 29
    • 0347286916 scopus 로고    scopus 로고
    • Intramedullary fixation of unstable intertrochanteric hip fractures: one or two lag screws
    • Kubiak EN, Bong M, Park SS, et al. Intramedullary fixation of unstable intertrochanteric hip fractures: one or two lag screws. J Orthop Trauma. 2004;18:12-17.
    • (2004) J Orthop Trauma , vol.18 , pp. 12-17
    • Kubiak, E.N.1    Bong, M.2    Park, S.S.3
  • 30
    • 80051780692 scopus 로고    scopus 로고
    • Trochanteric femoral fractures: anatomy, biomechanics and choice of implants in German
    • Bonnaire F, Lein T, Bula P. Trochanteric femoral fractures: anatomy, biomechanics and choice of implants [in German]. Unfallchirurg. 2011;114:491-500.
    • (2011) Unfallchirurg , vol.114 , pp. 491-500
    • Bonnaire, F.1    Lein, T.2    Bula, P.3
  • 31
    • 78650223555 scopus 로고    scopus 로고
    • Schiuma d, et al. does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? a biomechanical study. clin biomech (bristol
    • Wähnert D, Gudushauri P
    • Wähnert D, Gudushauri P, Schiuma D, et al. Does cancellous bone compaction due to insertion of a blade implant influence the cut-out resistance? A biomechanical study. Clin Biomech (Bristol, Avon). 2010;25:1053-1057.
    • (2010) Avon) , vol.25 , pp. 1053-1057
  • 32
    • 4043145938 scopus 로고    scopus 로고
    • A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation
    • Sommers MB, Roth C, Hall H, et al. A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation. J Orthop Trauma. 2004;18:361-368.
    • (2004) J Orthop Trauma , vol.18 , pp. 361-368
    • Sommers, M.B.1    Roth, C.2    Hall, H.3
  • 33
    • 80051781894 scopus 로고    scopus 로고
    • Treatment of peritrochanteric fractures: biomechanical considerations in German
    • Krischak G, Dürselen L, Röderer G. Treatment of peritrochanteric fractures: biomechanical considerations [in German]. Unfallchirurg. 2011;114:485-490.
    • (2011) Unfallchirurg , vol.114 , pp. 485-490
    • Krischak, G.1    Durselen, L.2    Roderer, G.3
  • 34
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech. 1993;26:969-990.
    • (1993) J Biomech , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 35
    • 85026171308 scopus 로고    scopus 로고
    • Quo vadis hip fractures. Presented at: Elba iv congress: Ortho trauma news
    • Gotfried Y. Quo vadis hip fractures. Presented at: Elba IV Congress: Ortho Trauma News, June 10-11, 2011.
    • (2011) June , pp. 10-11
    • Gotfried, Y.1
  • 36
    • 13244267040 scopus 로고    scopus 로고
    • Bone compaction enhances fixation of weightbearing titanium implants
    • Kold S, Rahbek O, Vestermark M, et al. Bone compaction enhances fixation of weightbearing titanium implants. Clin Orthop Relat Res. 2005;431:138-144.
    • (2005) Clin Orthop Relat Res , vol.431 , pp. 138-144
    • Kold, S.1    Rahbek, O.2    Vestermark, M.3
  • 37
    • 38749109180 scopus 로고    scopus 로고
    • Anisotropy of the fatigue behaviour of cancellous bone
    • Dendorfer S, Maier HJ, Taylor D, et al. Anisotropy of the fatigue behaviour of cancellous bone. J Biomech. 2008;41:636-641.
    • (2008) J Biomech , vol.41 , pp. 636-641
    • Dendorfer, S.1    Maier, H.J.2    Taylor, D.3
  • 38
    • 27644543881 scopus 로고    scopus 로고
    • Lag screws for hip fracture fixation: evaluation of migration resistance under simulated walking
    • Ehmke LW, Fitzpatrick DC, Krieg JC, et al. Lag screws for hip fracture fixation: evaluation of migration resistance under simulated walking. J Orthop Res. 2005;23:1329-1335.
    • (2005) J Orthop Res , vol.23 , pp. 1329-1335
    • Ehmke, L.W.1    Fitzpatrick, D.C.2    Krieg, J.C.3
  • 39
    • 77955274936 scopus 로고    scopus 로고
    • Assessment of the bilateral asymmetry of human femurs based on physical, densitometric, and structural rigidity characteristics
    • Pierre MA, Zurakowski D, Nazarian A, et al. Assessment of the bilateral asymmetry of human femurs based on physical, densitometric, and structural rigidity characteristics. J Biomech. 2010;43:2228-2236.
    • (2010) J Biomech , vol.43 , pp. 2228-2236
    • Pierre, M.A.1    Zurakowski, D.2    Nazarian, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.