메뉴 건너뛰기




Volumn 27, Issue 4, 2003, Pages 197-203

Implant-related complications in the treatment of unstable intertrochanteric fractures: Meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE PLATE; BONE SCREW; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMUR INTERTROCHANTERIC FRACTURE; FRACTURE FIXATION; HUMAN; IMPLANT; INTERMETHOD COMPARISON; INTRAMEDULLARY NAIL; MAJOR CLINICAL STUDY; META ANALYSIS; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSTHESIS FAILURE; RISK ASSESSMENT;

EID: 0041321380     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-003-0457-6     Document Type: Article
Times cited : (87)

References (26)
  • 1
    • 0035203607 scopus 로고    scopus 로고
    • Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur
    • Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15:394-400
    • (2001) J Orthop Trauma , vol.15 , pp. 394-400
    • Adams, C.I.1    Robinson, C.M.2    Court-Brown, C.M.3    McQueen, M.M.4
  • 3
    • 0031924186 scopus 로고    scopus 로고
    • Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    • Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop 348:87-94
    • (1998) Clin Orthop , vol.348 , pp. 87-94
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 4
    • 0026090325 scopus 로고
    • Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw
    • Bridle SH, Patel AD, Bircher M, Calvert PT (1991) Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg [Br] 73:330-334
    • (1991) J Bone Joint Surg [Br] , vol.73 , pp. 330-334
    • Bridle, S.H.1    Patel, A.D.2    Bircher, M.3    Calvert, P.T.4
  • 5
    • 0028866619 scopus 로고
    • Comparison of dynamic hip screw and gamma nail: A prospective, randomized, controlled trial
    • Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615-618
    • (1995) Injury , vol.26 , pp. 615-618
    • Butt, M.S.1    Krikler, S.J.2    Nafie, S.3    Ali, M.S.4
  • 6
    • 0002477735 scopus 로고    scopus 로고
    • Rationale, potentials, and promise of systematic reviews
    • Egger M, Smith G D, Altman DG (eds). BMJ Publishing, London
    • Egger M, Smith GD, O'Rourke K (2001) Rationale, potentials, and promise of systematic reviews. In: Egger M, Smith G D, Altman DG (eds) Systematic Reviews in Health Care-meta-analysis in context. BMJ Publishing, London pp 3-19
    • (2001) Systematic Reviews in Health Care - Meta-analysis in Context , pp. 3-19
    • Egger, M.1    Smith, G.D.2    O'Rourke, K.3
  • 7
    • 0030720013 scopus 로고    scopus 로고
    • Meta-analysis: Principles and procedures
    • Egger M, Smith GD, Phillips AN (1997) Meta-analysis: principles and procedures. BMJ 315:1533-1537
    • (1997) BMJ , vol.315 , pp. 1533-1537
    • Egger, M.1    Smith, G.D.2    Phillips, A.N.3
  • 9
    • 0027538530 scopus 로고
    • Poor reproducibility of Evans' classification of the trochanteric fracture. Assessment of 4 observers in 52 cases
    • Gehrchen PM, Nielsen JO, Olesen B (1993) Poor reproducibility of Evans' classification of the trochanteric fracture. Assessment of 4 observers in 52 cases. Acta Orthop Scand 64:71-72
    • (1993) Acta Orthop Scand , vol.64 , pp. 71-72
    • Gehrchen, P.M.1    Nielsen, J.O.2    Olesen, B.3
  • 10
    • 0028528650 scopus 로고
    • A prospective comparative study of the compression hip screw and the gamma nail
    • Goldhagen PR, O'Connor DR, Schwarze D, Schwartz E (1994) A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma 8:367-372
    • (1994) J Orthop Trauma , vol.8 , pp. 367-372
    • Goldhagen, P.R.1    O'Connor, D.R.2    Schwarze, D.3    Schwartz, E.4
  • 11
    • 0002826952 scopus 로고
    • The Gamma nail in per- and intertrochanteric femoral fractures-alternative or complementary to the DHS? A prospective randomised study
    • Marti R K, Dunki Jacobs P B (eds). Medical Press, London
    • Guyer P, Landolt M, Keller H, Eberle C (1993) The Gamma nail in per- and intertrochanteric femoral fractures-alternative or complementary to the DHS? A prospective randomised study. In: Marti R K, Dunki Jacobs P B (eds) Proximal femoral fractures - operative technique and complications. Medical Press, London pp 481-498
    • (1993) Proximal Femoral Fractures - Operative Technique and Complications , pp. 481-498
    • Guyer, P.1    Landolt, M.2    Keller, H.3    Eberle, C.4
  • 12
    • 0031808886 scopus 로고    scopus 로고
    • Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients
    • Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J. Bone Joint Surg [Am] 80:618-630
    • (1998) J Bone Joint Surg [Am] , vol.80 , pp. 618-630
    • Hardy, D.C.1    Descamps, P.Y.2    Krallis, P.3    Fabeck, L.4    Smets, P.5    Bertens, C.L.6    Delince, P.E.7
  • 13
    • 0036177813 scopus 로고    scopus 로고
    • Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    • Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33:23-28
    • (2002) Injury , vol.33 , pp. 23-28
    • Harrington, P.1    Nihal, A.2    Singhania, A.K.3    Howell, F.R.4
  • 14
    • 0032943158 scopus 로고    scopus 로고
    • Classic nail versus DHS. A prospective randomised study of fixation of trochanteric femur fractures
    • Hoffmann R, Schmidmaier G, Schulz R, Schutz M, Sudkamp NP (1999) [Classic nail versus DHS. A prospective randomised study of fixation of trochanteric femur fractures]. Unfallchirurg 102:182-190
    • (1999) Unfallchirurg , vol.102 , pp. 182-190
    • Hoffmann, R.1    Schmidmaier, G.2    Schulz, R.3    Schutz, M.4    Sudkamp, N.P.5
  • 15
    • 0027408340 scopus 로고
    • Interobserver variation using the AO/ASIF classification of long bone fractures
    • Johnstone DJ, Radford WJ, Parnell EJ (1993) Interobserver variation using the AO/ASIF classification of long bone fractures. Injury 24:163-165
    • (1993) Injury , vol.24 , pp. 163-165
    • Johnstone, D.J.1    Radford, W.J.2    Parnell, E.J.3
  • 19
    • 0026504845 scopus 로고
    • Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients
    • Leung S, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg [Br] 74:345-351
    • (1992) J Bone Joint Surg [Br] , vol.74 , pp. 345-351
    • Leung, S.1    So, W.S.2    Shen, W.Y.3    Hui, P.W.4
  • 20
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw
    • Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241-248
    • (1998) J Orthop Trauma , vol.12 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3    Alho, A.4    Ekeland, A.5    Stromsoe, K.6
  • 21
    • 0029616325 scopus 로고
    • Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    • O'Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516-520
    • (1995) Can J Surg , vol.38 , pp. 516-520
    • O'Brien, P.J.1    Meek, R.N.2    Blachut, P.A.3    Broekhuyse, H.M.4    Sabharwal, S.5
  • 22
    • 0042932849 scopus 로고
    • Comparing the gamma nail and the dynamic hip screw in the treatment of pertrochanteric fractures. Preliminary results of a prospective randomised study
    • Marti RK, Dunki Jacobs P B (eds). Medical Press, London
    • Pahlplatz PVM, Langius FB (1993) Comparing the gamma nail and the dynamic hip screw in the treatment of pertrochanteric fractures. Preliminary results of a prospective randomised study. In: Marti RK, Dunki Jacobs P B (eds) Proximal femoral fractures - operative techniques and complications. Medical Press, London pp 475-480
    • (1993) Proximal Femoral Fractures - Operative Techniques and Complications , pp. 475-480
    • Pahlplatz, P.V.M.1    Langius, F.B.2
  • 23
    • 0031866341 scopus 로고    scopus 로고
    • Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - A randomised prospective trial
    • Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - a randomised prospective trial. Int Orthop 22:157-160
    • (1998) Int Orthop , vol.22 , pp. 157-160
    • Park, S.R.1    Kang, J.S.2    Kim, H.S.3    Lee, W.H.4    Kim, Y.H.5
  • 24
    • 84921622711 scopus 로고    scopus 로고
    • Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures
    • Update Software, Oxford
    • Parker MJ, Handoll HH (2002) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures. In: The Cochrane Library, Update Software, Oxford
    • (2002) The Cochrane Library
    • Parker, M.J.1    Handoll, H.H.2
  • 25
    • 0042536513 scopus 로고    scopus 로고
    • Condylocephalic nails versus extramedullary implants for extracapsular hip fractures
    • Update Software, Oxford
    • Parker MJ, Handoll HH, Bhonsle S, Gillespie WJ (2002) Condylocephalic nails versus extramedullary implants for extracapsular hip fractures. In: The Cochrane Library, Update Software, Oxford
    • (2002) The Cochrane Library
    • Parker, M.J.1    Handoll, H.H.2    Bhonsle, S.3    Gillespie, W.J.4
  • 26
    • 0025103566 scopus 로고
    • Postoperative improvement of walking capacity in patients with trochanteric hip fracture: A prospective analysis 3 and 6 months after surgery
    • Walheim G, Barrios C, Stark A, Brostrom LA, Olsson E (1990) Postoperative improvement of walking capacity in patients with trochanteric hip fracture: a prospective analysis 3 and 6 months after surgery. J Orthop Trauma 4:137-143
    • (1990) J Orthop Trauma , vol.4 , pp. 137-143
    • Walheim, G.1    Barrios, C.2    Stark, A.3    Brostrom, L.A.4    Olsson, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.