메뉴 건너뛰기




Volumn 23, Issue 2, 2013, Pages 218-223

Incorrect order of draw could be mitigate the patient safety: A phlebotomy management case report

Author keywords

Blood specimen collection; Clinical laboratory techniques; EDTA contamination carryover; Laboratory variability; Preanalytical phase

Indexed keywords

ADULT; ARTICLE; BLOOD GAS; BLOOD SAMPLING; CASE REPORT; HUMAN; HYPERKALEMIA; HYPOCALCEMIA; MALE; OUTPATIENT; PATIENT SAFETY; PHLEBOTOMY; QUALITY CONTROL; SYRINGE NEEDLE; VEIN PUNCTURE;

EID: 84878769896     PISSN: 13300962     EISSN: None     Source Type: Journal    
DOI: 10.11613/BM.2013.026     Document Type: Article
Times cited : (25)

References (30)
  • 1
    • 84865372924 scopus 로고    scopus 로고
    • Preanalytical phase -a continuous challenge for laboratory professionals
    • Simundic AM, Lippi G. Preanalytical phase -a continuous challenge for laboratory professionals. Biochem Med 2012;22:145-9. http://dx.doi.org/10.11613/BM.2012.017.
    • (2012) Biochem Med , vol.22 , pp. 145-149
    • Simundic, A.M.1    Lippi, G.2
  • 2
    • 77149158201 scopus 로고    scopus 로고
    • Self reported routines and procedures for the extraanalytical phase of laboratory practice in Croatia -crosssectional survey study
    • Bilic-Zulle L, Simundic AM, Supak-Smolcic V, Nikolac N, Honovic L. Self reported routines and procedures for the extraanalytical phase of laboratory practice in Croatia -crosssectional survey study. Biochem Med 2010;20:64-74. http://dx.doi.org/10.11613/BM.2010.008.
    • (2010) Biochem Med , vol.20 , pp. 64-74
    • Bilic-Zulle, L.1    Simundic, A.M.2    Supak-Smolcic, V.3    Nikolac, N.4    Honovic, L.5
  • 5
    • 84867259653 scopus 로고    scopus 로고
    • Is phlebotomy part of the dark side in the clinical laboratory struggle for quality?
    • Lima-Oliveira G, Guidi GC, Salvagno GL, Montagnana M, Rego FGM, Lippi G, et al. Is phlebotomy part of the dark side in the clinical laboratory struggle for quality? Lab Med 2012;43:17-21. http://dx.doi.org/10.1309/LMZ7YARD6ZSDIID.
    • (2012) Lab Med , vol.43 , pp. 17-21
    • Lima-Oliveira, G.1    Guidi, G.C.2    Salvagno, G.L.3    Montagnana, M.4    Rego, F.G.M.5    Lippi, G.6
  • 6
    • 77149152841 scopus 로고    scopus 로고
    • Total quality in laboratory diagnostics. It's time to think outside the box
    • Lippi G, Simundic AM. Total quality in laboratory diagnostics. It's time to think outside the box. Biochem Med 2010;20:5-8. http://dx.doi.org/10.11613/BM.2010.001.
    • (2010) Biochem Med , vol.20 , pp. 5-8
    • Lippi, G.1    Simundic, A.M.2
  • 7
    • 79960130914 scopus 로고    scopus 로고
    • New ways to deal with known preanalytical issues: Use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Mangueira C, Sumita N, et al. New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry. Biochem Med 2011;21:152-9. http://dx.doi.org/10.11613/BM.2011.024.
    • (2011) Biochem Med , vol.21 , pp. 152-159
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Mangueira, C.5    Sumita, N.6
  • 8
    • 79960131955 scopus 로고    scopus 로고
    • Transillumination: A new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Scartezini M, Guidi GC, et al. Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing. Int J Lab Hematol 2011;33:457-62.
    • (2011) Int J Lab Hematol , vol.33 , pp. 457-462
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Scartezini, M.5    Guidi, G.C.6
  • 9
    • 79956333080 scopus 로고    scopus 로고
    • Elimination of the venous stasis error for routine coagulation testing by transillumination
    • Lima-Oliveira G, Salvagno GL, Lippi G, Montagnana M, Scartezini M, Picheth G, et al. Elimination of the venous stasis error for routine coagulation testing by transillumination. Clin Chim Acta 2011;412:1482-4. http://dx.doi.org/10.1016/j.cca.2011.04.008.
    • (2011) Clin Chim Acta , vol.412 , pp. 1482-1484
    • Lima-Oliveira, G.1    Salvagno, G.L.2    Lippi, G.3    Montagnana, M.4    Scartezini, M.5    Picheth, G.6
  • 11
    • 0027247779 scopus 로고
    • The significance of ionized calcium in cardiac and critical care. Availability and critical limits at US medical centers and chidren's hospitals
    • Kost GJ. The significance of ionized calcium in cardiac and critical care. Availability and critical limits at US medical centers and chidren's hospitals. Arch Pathol Lab Med 1993;117:890-6.
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 890-896
    • Kost, G.J.1
  • 12
    • 0027563657 scopus 로고
    • Using critical limits to improve patient outcome
    • Kost GJ. Using critical limits to improve patient outcome. MLO Med Lab Obs 1993;25:22-7.
    • (1993) MLO Med Lab Obs , vol.25 , pp. 22-27
    • Kost, G.J.1
  • 15
    • 17444444102 scopus 로고
    • Recommended "order of draw" for collecting blood specimens into additive-containing tubes
    • Calam RR, Cooper MH. Recommended "order of draw" for collecting blood specimens into additive-containing tubes. Clin Chem 1982;28:1399.
    • (1982) Clin Chem , vol.28 , pp. 1399
    • Calam, R.R.1    Cooper, M.H.2
  • 16
    • 84867280165 scopus 로고    scopus 로고
    • Impact of the phlebotomy training based on CLSI/NCCLS H03-A6 -procedures for the collection of diagnostic blood specimens by venipuncture
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Impact of the phlebotomy training based on CLSI/NCCLS H03-A6 -procedures for the collection of diagnostic blood specimens by venipuncture. Biochem Med 2012;22:342-51. http://dx.doi.org/10.11613/BM.2012.036.
    • (2012) Biochem Med , vol.22 , pp. 342-351
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Picheth, G.5    Guidi, G.C.6
  • 17
    • 80054883653 scopus 로고    scopus 로고
    • Effect of order of draw of blood samples during phlebotomy on routine biochemistry results
    • Sulaiman RA, Cornes MP, Whitehead SJ, Othonos N, Ford C, Gama R. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results. J Clin Pathol 2011;64:1019-20. http://dx.doi.org/10.1136/jclinpath-2011-200206.
    • (2011) J Clin Pathol , vol.64 , pp. 1019-1020
    • Sulaiman, R.A.1    Cornes, M.P.2    Whitehead, S.J.3    Othonos, N.4    Ford, C.5    Gama, R.6
  • 19
    • 84861234251 scopus 로고    scopus 로고
    • Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test?
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test? Clin Biochem 2012;45:683-7. http://dx.doi.org/10.1016/j.clinbiochem.2012.03.007.
    • (2012) Clin Biochem , vol.45 , pp. 683-687
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Picheth, G.5    Guidi, G.C.6
  • 21
    • 84865388373 scopus 로고    scopus 로고
    • Pre analytical management: Serum vacuum tubes validation for routine clinical chemistry
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Pre analytical management: serum vacuum tubes validation for routine clinical chemistry. Biochem Med 2012;22:180-6. http://dx.doi.org/10.11613/BM.2012.021.
    • (2012) Biochem Med , vol.22 , pp. 180-186
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Picheth, G.5    Guidi, G.C.6
  • 22
    • 84875823372 scopus 로고    scopus 로고
    • Sodium citrate vacuum tubes validation: Preventing preanalytical variability in routine coagulation testing
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing. Blood Coagul Fibrinolysis 2013;24:252-5. http://dx.doi.org/10.1097/MBC.0b013e32835b72ea.
    • (2013) Blood Coagul Fibrinolysis , vol.24 , pp. 252-255
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Picheth, G.5    Guidi, G.C.6
  • 23
    • 84878758868 scopus 로고    scopus 로고
    • The brand of K2EDTA vacuum tubes as a new source of preanalytical variability in routine hematology testing
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Poli G, Solero GP, et al. The brand of K2EDTA vacuum tubes as a new source of preanalytical variability in routine hematology testing. Brit J Biomed Sci 2013;70:6-9.
    • (2013) Brit J Biomed Sci , vol.70 , pp. 6-9
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Poli, G.5    Solero, G.P.6
  • 24
    • 55949131818 scopus 로고    scopus 로고
    • Spurious hyperkalaemia due to EDTA contamination: Common and not always easy to identify
    • Cornes MP, Ford C, Gama R. Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify. Ann Clin Biochem 2008;45:601-3. http://dx.doi. org/10.1258/acb.2008.007241.
    • (2008) Ann Clin Biochem , vol.45 , pp. 601-603
    • Cornes, M.P.1    Ford, C.2    Gama, R.3
  • 25
    • 77957655138 scopus 로고    scopus 로고
    • Serum ethylenediaminetetraacetic acid concentrations in routine samples submitted for biochemical analysis
    • White G. Serum ethylenediaminetetraacetic acid concentrations in routine samples submitted for biochemical analysis. Ann Clin Biochem 2010;47:485-6. http://dx.doi.org/10.1258/acb.2010.009306.
    • (2010) Ann Clin Biochem , vol.47 , pp. 485-486
    • White, G.1
  • 26
    • 0036774813 scopus 로고    scopus 로고
    • Combined false hyperkalemia and hypocalcemia due to specimen contamination during routine phlebotomy
    • Naguib MT, Evans N. Combined false hyperkalemia and hypocalcemia due to specimen contamination during routine phlebotomy. South Med J 2002;95:1218-20.
    • (2002) South Med J , vol.95 , pp. 1218-1220
    • Naguib, M.T.1    Evans, N.2
  • 27
    • 64649094127 scopus 로고    scopus 로고
    • National Committee for Clinical Laboratory Standards., NCCLS document H1-A5.5th ed. Wayne, PA: National Committee for Clinical Laboratory Standards
    • National Committee for Clinical Laboratory Standards. Tubes and additives for venous blood specimen collection. NCCLS document H1-A5.5th ed. Wayne, PA: National Committee for Clinical Laboratory Standards; 2003.
    • (2003) Tubes and Additives For Venous Blood Specimen Collection
  • 29
    • 77958181146 scopus 로고    scopus 로고
    • The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: A new tool to assess the acceptability of intensive care unit testing
    • Cembrowski GS, Tran DV, Higgins TN. The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing. Clin Chem Lab Med 2010;48:1447-54. http://dx.doi.org/10.1515/cclm.2010.286.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1447-1454
    • Cembrowski, G.S.1    Tran, D.V.2    Higgins, T.N.3
  • 30
    • 3042678694 scopus 로고    scopus 로고
    • The reference change value: A proposal to interpret laboratory reports in serial testing based on biological variation
    • Ricos C, Cava F, Garcia-Lario JV, Hernandez A, Iglesias N, Jimenez CV, et al. The reference change value: a proposal to interpret laboratory reports in serial testing based on biological variation. Scand J Clin Lab Invest 2004;64:175-84. http://dx.doi.org/10.1080/00365510410004885.
    • (2004) Scand J Clin Lab Invest , vol.64 , pp. 175-184
    • Ricos, C.1    Cava, F.2    Garcia-Lario, J.V.3    Hernandez, A.4    Iglesias, N.5    Jimenez, C.V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.