메뉴 건너뛰기




Volumn 17, Issue 3, 2013, Pages 681-690

Poly(4-vinylpyridine-co-aniline)-modified electrode - Synthesis, characterization, and application as cadmium(II) ion sensor

Author keywords

Cadmium(II) ion; Electropolymerization; Pencil graphite; Poly(4 vinylpyridine co aniline); Solid state electrode

Indexed keywords

ELECTRODES; ELECTROPOLYMERIZATION; GRAPHITE; IONS; SPECTROPHOTOMETRY;

EID: 84878502924     PISSN: 14328488     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10008-012-1910-5     Document Type: Article
Times cited : (15)

References (48)
  • 1
    • 81955161942 scopus 로고    scopus 로고
    • Simultaneous preconcentration of cadmium, cobalt and nickel in water samples by cationic micellar precipitation and their determination by inductively coupled plasma-optical emission spectrometry
    • 10.1016/j.microc.2011.09.003 1:CAS:528:DC%2BC3MXhsVOis77O
    • Beiraghi A, Babaee S, Roshdi M (2012) Simultaneous preconcentration of cadmium, cobalt and nickel in water samples by cationic micellar precipitation and their determination by inductively coupled plasma-optical emission spectrometry. Microchem J 100:66-71
    • (2012) Microchem J , vol.100 , pp. 66-71
    • Beiraghi, A.1    Babaee, S.2    Roshdi, M.3
  • 2
    • 34247526842 scopus 로고    scopus 로고
    • Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: Comparative study of different chemical modifiers
    • 10.1016/j.aca.2007.03.062
    • Farinas MV, Garcia JB, Martin SG, Crecente RP, Latorre CH (2007) Direct determination of cadmium in Orujo spirit samples by electrothermal atomic absorption spectrometry: comparative study of different chemical modifiers. Anal Chim Acta 591:231-238
    • (2007) Anal Chim Acta , vol.591 , pp. 231-238
    • Farinas, M.V.1    Garcia, J.B.2    Martin, S.G.3    Crecente, R.P.4    Latorre, C.H.5
  • 3
    • 58149279292 scopus 로고    scopus 로고
    • Thermospray nebulization for flame furnace atomic absorption spectrometry - Correlations between spray formation and cadmium analytical sensitivity
    • 10.1016/j.sab.2008.10.041
    • Brancalion ML, Sabadini E, Arruda MAZ (2009) Thermospray nebulization for flame furnace atomic absorption spectrometry - correlations between spray formation and cadmium analytical sensitivity. Spectrochim Acta 64:89-94
    • (2009) Spectrochim Acta , vol.64 , pp. 89-94
    • Brancalion, M.L.1    Sabadini, E.2    Arruda, M.A.Z.3
  • 4
    • 84355166525 scopus 로고    scopus 로고
    • Utility of solid phase spectrophotometry for the modified determination of trace amounts of cadmium in food samples
    • 10.1016/j.foodchem.2011.10.028 1:CAS:528:DC%2BC3MXhs1Kqs7rK
    • Amin AS, Gouda AA (2012) Utility of solid phase spectrophotometry for the modified determination of trace amounts of cadmium in food samples. Food Chem 132:518-524
    • (2012) Food Chem , vol.132 , pp. 518-524
    • Amin, A.S.1    Gouda, A.A.2
  • 5
    • 51649091350 scopus 로고    scopus 로고
    • Determination of cadmium, lead, copper and zinc in the acetic acid extract of glazed ceramic surfaces by anodic stripping voltammetric method
    • 10.1016/j.talanta.2008.06.003 1:CAS:528:DC%2BD1cXhtFCitrvL
    • Jakmunee J, Junsomboon J (2008) Determination of cadmium, lead, copper and zinc in the acetic acid extract of glazed ceramic surfaces by anodic stripping voltammetric method. Talanta 77:172-175
    • (2008) Talanta , vol.77 , pp. 172-175
    • Jakmunee, J.1    Junsomboon, J.2
  • 6
    • 84862692212 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of trace bismuth(III) and cadmium(II) in water samples by adsorptive stripping voltammetry in the presence of cupferron
    • 10.1016/j.jelechem.2012.05.020 1:CAS:528:DC%2BC38XhtFSis7nL
    • Koper A, Grabarczyk M (2012) Simultaneous voltammetric determination of trace bismuth(III) and cadmium(II) in water samples by adsorptive stripping voltammetry in the presence of cupferron. J Electroanal Chem 681:1-5
    • (2012) J Electroanal Chem , vol.681 , pp. 1-5
    • Koper, A.1    Grabarczyk, M.2
  • 7
    • 64249148356 scopus 로고    scopus 로고
    • Bismuth-coated screen-printed microband electrodes for on-field labile cadmium determination
    • 10.1002/elan.200804465 1:CAS:528:DC%2BD1MXktVaiu7k%3D
    • Zaouak O, Authier L, Cugnent C, Castetbon A, Potin-Gautier M (2009) Bismuth-coated screen-printed microband electrodes for on-field labile cadmium determination. Electroanalysis 21:689-695
    • (2009) Electroanalysis , vol.21 , pp. 689-695
    • Zaouak, O.1    Authier, L.2    Cugnent, C.3    Castetbon, A.4    Potin-Gautier, M.5
  • 8
    • 82455219062 scopus 로고    scopus 로고
    • New application of tin-bismuth alloy for electrochemical determination of cadmium
    • 10.1016/j.matlet.2011.11.038 1:CAS:528:DC%2BC3MXhs1OmtbfP
    • Pan D, Zhang L, Zhuang J, Lu W, Zhu R, Qin W (2012) New application of tin-bismuth alloy for electrochemical determination of cadmium. Mater Lett 68:472-474
    • (2012) Mater Lett , vol.68 , pp. 472-474
    • Pan, D.1    Zhang, L.2    Zhuang, J.3    Lu, W.4    Zhu, R.5    Qin, W.6
  • 10
    • 13944269075 scopus 로고    scopus 로고
    • Potentiometric sensors for trace-level analysis
    • 10.1016/j.trac.2005.01.003 1:CAS:528:DC%2BD2MXhs12ktbc%3D
    • Bakker E, Pretsch E (2005) Potentiometric sensors for trace-level analysis. Trends Anal Chem 24:199-207
    • (2005) Trends Anal Chem , vol.24 , pp. 199-207
    • Bakker, E.1    Pretsch, E.2
  • 11
    • 51449124125 scopus 로고    scopus 로고
    • Detection of ultra-low activities of heavy metal ions by an array of potentiometric chemical sensors
    • 10.1007/s00604-007-0900-2 1:CAS:528:DC%2BD1cXhtVyitrzK
    • Rudnitskaya A, Legin A, Seleznev B, Kirsanov D, Vlasov Y (2008) Detection of ultra-low activities of heavy metal ions by an array of potentiometric chemical sensors. Microchim Acta 163:71-80
    • (2008) Microchim Acta , vol.163 , pp. 71-80
    • Rudnitskaya, A.1    Legin, A.2    Seleznev, B.3    Kirsanov, D.4    Vlasov, Y.5
  • 12
    • 0036855184 scopus 로고    scopus 로고
    • Plasticizer-free polymer membrane ion-selective electrodes containing a methacrylic copolymer matrix
    • 10.1002/1521-4109(200211)14:19/20<1375: AID-ELAN1375>3.0.CO;2-8 1:CAS:528:DC%2BD38XptVymu7k%3D
    • Qin Y, Peper S, Bakker E (2002) Plasticizer-free polymer membrane ion-selective electrodes containing a methacrylic copolymer matrix. Electroanalysis 14:1375-1381
    • (2002) Electroanalysis , vol.14 , pp. 1375-1381
    • Qin, Y.1    Peper, S.2    Bakker, E.3
  • 13
    • 0033652852 scopus 로고    scopus 로고
    • +-selective methacrylic-acrylic copolymer containing grafted ionophore and requiring no plasticizer
    • 10.1002/(SICI)1521-4109(200002)12:3<178: AID-ELAN178>3.0.CO;2-Z 1:CAS:528:DC%2BD3cXhvVGluro%3D
    • +-selective methacrylic-acrylic copolymer containing grafted ionophore and requiring no plasticizer. Electroanalysis 12:178-186
    • (2000) Electroanalysis , vol.12 , pp. 178-186
    • Heng, L.Y.1    Hall, E.A.H.2
  • 14
    • 33645993274 scopus 로고    scopus 로고
    • Amperometric ammonium ion sensor based on polyaniline- poly(styrenesulfonate-co-maleic acid) composite conducting polymeric electrode
    • 10.1016/j.snb.2005.08.027
    • Luo YC, Do JS (2006) Amperometric ammonium ion sensor based on polyaniline-poly(styrenesulfonate-co-maleic acid) composite conducting polymeric electrode. Sens Actuators B 115:102-108
    • (2006) Sens Actuators B , vol.115 , pp. 102-108
    • Luo, Y.C.1    Do, J.S.2
  • 16
    • 67949118683 scopus 로고    scopus 로고
    • Preparation of all solid-state potentiometric ion sensors with polymer-CNT composites
    • 10.1016/j.elecom.2009.06.025 1:CAS:528:DC%2BD1MXps1WrtL8%3D
    • Zhu J, Qin Y, Zhang Y (2009) Preparation of all solid-state potentiometric ion sensors with polymer-CNT composites. Electrochem Commun 11:1684-1687
    • (2009) Electrochem Commun , vol.11 , pp. 1684-1687
    • Zhu, J.1    Qin, Y.2    Zhang, Y.3
  • 17
    • 0002849122 scopus 로고    scopus 로고
    • Methacrylic-acrylic polymers in ion-selective membranes: Achieving the right polymer recipe
    • 10.1016/S0003-2670(99)00647-9 1:CAS:528:DyaK1MXnsFeqtrg%3D
    • Heng LY, Hall EAH (2000) Methacrylic-acrylic polymers in ion-selective membranes: achieving the right polymer recipe. Anal Chim Acta 403:77-89
    • (2000) Anal Chim Acta , vol.403 , pp. 77-89
    • Heng, L.Y.1    Hall, E.A.H.2
  • 18
    • 84878480495 scopus 로고    scopus 로고
    • Characteristics of solid-state calcium ion sensors based on photocurable and selfplasticising polyacrylate matrices
    • Heng LY, Hall EAH (2006) Characteristics of solid-state calcium ion sensors based on photocurable and selfplasticising polyacrylate matrices. AJSTD 23:261-273
    • (2006) AJSTD , vol.23 , pp. 261-273
    • Heng, L.Y.1    Hall, E.A.H.2
  • 19
    • 0344897215 scopus 로고    scopus 로고
    • Peroxydisulfate initiated graft copolymerization of aniline onto poly(propylene) fiber - A kinetic approach
    • 10.1002/app.13115 1:CAS:528:DC%2BD3sXptFGgsb4%3D
    • Anbarasan R, Jayaseharan J, Sudha M, Gopalan A (2003) Peroxydisulfate initiated graft copolymerization of aniline onto poly(propylene) fiber - a kinetic approach. J Appl Polym Sci 90:3827-3834
    • (2003) J Appl Polym Sci , vol.90 , pp. 3827-3834
    • Anbarasan, R.1    Jayaseharan, J.2    Sudha, M.3    Gopalan, A.4
  • 20
    • 0035097656 scopus 로고    scopus 로고
    • Synthesis and characterization of poly(ethylene glycol)-grafted polyaniline
    • 10.1021/cm000829c 1:CAS:528:DC%2BD3MXnt1Kluw%3D%3D
    • Wang P, Tan KL (2001) Synthesis and characterization of poly(ethylene glycol)-grafted polyaniline. Chem Mater 13:581-587
    • (2001) Chem Mater , vol.13 , pp. 581-587
    • Wang, P.1    Tan, K.L.2
  • 21
    • 40949158088 scopus 로고    scopus 로고
    • Synthesis and characterization of biopolymer-based electrical conducting graft copolymers
    • 10.1002/app.27789 1:CAS:528:DC%2BD1cXisFymtLc%3D
    • Tiwari A, Singh SP (2008) Synthesis and characterization of biopolymer-based electrical conducting graft copolymers. J Appl Polym Sci 108:1169-1177
    • (2008) J Appl Polym Sci , vol.108 , pp. 1169-1177
    • Tiwari, A.1    Singh, S.P.2
  • 22
    • 57349198908 scopus 로고    scopus 로고
    • Substituted polyaniline/chitosan composites: Synthesis and characterization
    • 10.1016/j.carbpol.2008.08.005 1:CAS:528:DC%2BD1cXhsFWjur3P
    • Yavuz AG, Uygun A, Bhethanabotla VR (2009) Substituted polyaniline/chitosan composites: synthesis and characterization. Carbohydr Polym 75:448-453
    • (2009) Carbohydr Polym , vol.75 , pp. 448-453
    • Yavuz, A.G.1    Uygun, A.2    Bhethanabotla, V.R.3
  • 23
    • 20444471870 scopus 로고    scopus 로고
    • Conductive copolymers of polyaniline, polypyrrole and poly(dimethylsiloxane)
    • 10.1016/j.synthmet.2005.02.019 1:CAS:528:DC%2BD2MXlsFahsrc%3D
    • Cakmak G, Kucukyavuz Z, Kucukyavuz S (2005) Conductive copolymers of polyaniline, polypyrrole and poly(dimethylsiloxane). Synth Met 151:10-18
    • (2005) Synth Met , vol.151 , pp. 10-18
    • Cakmak, G.1    Kucukyavuz, Z.2    Kucukyavuz, S.3
  • 24
    • 0035946355 scopus 로고    scopus 로고
    • Beryllium-selective membrane sensor based on 3,4-di[2-(2-tetrahydro-2H- pyranoxy)]ethoxy styrene-styrene copolymer
    • 10.1016/S0003-2670(01)00802-9 1:CAS:528:DC%2BD3MXjt12nsbg%3D
    • Shamsipur M, Ganjali MR, Rouhollahi A, Moghimi A (2001) Beryllium-selective membrane sensor based on 3,4-di[2-(2-tetrahydro-2H-pyranoxy) ]ethoxy styrene-styrene copolymer. Anal Chim Acta 434:23-27
    • (2001) Anal Chim Acta , vol.434 , pp. 23-27
    • Shamsipur, M.1    Ganjali, M.R.2    Rouhollahi, A.3    Moghimi, A.4
  • 25
    • 0842287649 scopus 로고    scopus 로고
    • New and novel organic-inorganic type crystalline 'polypyrrolel/ polyantimonic acid' composite system: Preparation, characterization and analytical applications as a cation-exchange material and Hg(II) ion-selective membrane electrode
    • 10.1016/j.aca.2003.10.054 1:CAS:528:DC%2BD2cXptVeqtg%3D%3D
    • Khan AA, Alam MM (2004) New and novel organic-inorganic type crystalline 'polypyrrolel/polyantimonic acid' composite system: preparation, characterization and analytical applications as a cation-exchange material and Hg(II) ion-selective membrane electrode. Anal Chim Acta 504:253-264
    • (2004) Anal Chim Acta , vol.504 , pp. 253-264
    • Khan, A.A.1    Alam, M.M.2
  • 26
    • 0033663906 scopus 로고    scopus 로고
    • Cadmium ion selective electrode based on cyanocopolymer
    • 10.1002/1521-4109(200011)12:17<1408: AID-ELAN1408>3.0.CO;2-H 1:CAS:528:DC%2BD3cXos1Sltb0%3D
    • Gupta KC, D'Arc MJ (2000) Cadmium ion selective electrode based on cyanocopolymer. Electroanalysis 12:1408-1413
    • (2000) Electroanalysis , vol.12 , pp. 1408-1413
    • Gupta, K.C.1    D'Arc, M.J.2
  • 27
    • 1342339017 scopus 로고    scopus 로고
    • A hydrogen ion-selective sensor based on non-plasticised methacrylic-acrylic membranes
    • 10.3390/s20800339 1:CAS:528:DC%2BD38XnvVShur4%3D
    • Heng LY, Chern LH, Ahmad M (2002) A hydrogen ion-selective sensor based on non-plasticised methacrylic-acrylic membranes. Sensors 2:339-346
    • (2002) Sensors , vol.2 , pp. 339-346
    • Heng, L.Y.1    Chern, L.H.2    Ahmad, M.3
  • 28
    • 84855980621 scopus 로고    scopus 로고
    • Electro polymerized 4-vinyl pyridine on 2B pencil graphite as ionophore for cadmium (II)
    • 10.1016/j.talanta.2011.11.018 1:CAS:528:DC%2BC38XhtFKltr8%3D
    • Ling JLW, Khan A, Saad B, Ab Ghani S (2012) Electro polymerized 4-vinyl pyridine on 2B pencil graphite as ionophore for cadmium (II). Talanta 88:477-483
    • (2012) Talanta , vol.88 , pp. 477-483
    • Ling, J.L.W.1    Khan, A.2    Saad, B.3    Ab Ghani, S.4
  • 29
    • 0034871499 scopus 로고    scopus 로고
    • Poly(Fe-4-vinylpyridine) modified composite graphite paste electrode for the analysis of iron(III)
    • 10.1080/03067310108035907 1:CAS:528:DC%2BD3MXmvF2lsLs%3D
    • Halim AA, Ab Ghani S (2001) Poly(Fe-4-vinylpyridine) modified composite graphite paste electrode for the analysis of iron(III). Int J Environ Anal Chem 79:155-165
    • (2001) Int J Environ Anal Chem , vol.79 , pp. 155-165
    • Halim, A.A.1    Ab Ghani, S.2
  • 30
    • 57049106776 scopus 로고    scopus 로고
    • An ion selective electrode for mercury(II) based on mercury(II) complex of poly(4-vinyl pyridine)
    • 10.1016/j.jelechem.2008.08.007 1:CAS:528:DC%2BD1cXhsVKnu7zJ
    • Bakhtiarzadeh F, Ab Ghani S (2008) An ion selective electrode for mercury(II) based on mercury(II) complex of poly(4-vinyl pyridine). J Electroanal Chem 624:139-143
    • (2008) J Electroanal Chem , vol.624 , pp. 139-143
    • Bakhtiarzadeh, F.1    Ab Ghani, S.2
  • 31
    • 33745099573 scopus 로고    scopus 로고
    • Voltammetric analysis of glucose using poly 4-vinylpyridine modified carbon fiber electrode
    • 10.1080/03067310500149676 1:CAS:528:DC%2BD2MXhtVWgtLzE
    • Ahmad F, Ab Ghani S (2005) Voltammetric analysis of glucose using poly 4-vinylpyridine modified carbon fiber electrode. Int J Environ Anal Chem 85:781-793
    • (2005) Int J Environ Anal Chem , vol.85 , pp. 781-793
    • Ahmad, F.1    Ab Ghani, S.2
  • 32
    • 54549105765 scopus 로고    scopus 로고
    • Heterogenous membrane and coated wire type electrode with chitosan as ionophore in the potentiometric determination of glutamate: Comparative study
    • 10.1002/elan.200804243 1:CAS:528:DC%2BD1cXhtF2jsbfN
    • Isa IM, Ab Ghani S (2008) Heterogenous membrane and coated wire type electrode with chitosan as ionophore in the potentiometric determination of glutamate: comparative study. Electroanalysis 20:1782-1787
    • (2008) Electroanalysis , vol.20 , pp. 1782-1787
    • Isa, I.M.1    Ab Ghani, S.2
  • 33
    • 78650522558 scopus 로고    scopus 로고
    • 6+ ions
    • 10.1016/j.carbpol.2010.10.068 1:CAS:528:DC%2BC3cXhs1Wmtr7K
    • 6+ ions. Carbohydr Polym 83:1929-1936
    • (2011) Carbohydr Polym , vol.83 , pp. 1929-1936
    • Sharma, R.K.1    Lalita2
  • 34
    • 70350621369 scopus 로고    scopus 로고
    • Conductivity study of some polymer electrolytes based on polyacrylonitrile
    • 10.1007/s11581-009-0321-9 1:CAS:528:DC%2BD1MXht12hu73I
    • Borah P, Dutta A (2009) Conductivity study of some polymer electrolytes based on polyacrylonitrile. Ionics 15:711-716
    • (2009) Ionics , vol.15 , pp. 711-716
    • Borah, P.1    Dutta, A.2
  • 35
    • 36148967705 scopus 로고    scopus 로고
    • Electrochemical synthesis of copolymer of aniline and o-aminophenol and its use to the electrocatalytic oxidation of ascorbic acid
    • 10.1016/j.jelechem.2007.08.002 1:CAS:528:DC%2BD2sXhtlChtbfM
    • Zhang L, Lian J (2007) Electrochemical synthesis of copolymer of aniline and o-aminophenol and its use to the electrocatalytic oxidation of ascorbic acid. J Electroanal Chem 611:51-59
    • (2007) J Electroanal Chem , vol.611 , pp. 51-59
    • Zhang, L.1    Lian, J.2
  • 36
    • 84862782697 scopus 로고    scopus 로고
    • Electrochemical synthesis, characterization and electrochromic properties of a copolymer based on 1,4-bis(2-thienyl)naphthalene and pyrene
    • 10.1016/j.optmat.2012.01.009 1:CAS:528:DC%2BC38XjsF2mu7k%3D
    • Wang B, Zhao J, Cui C, Wang M, Wang Z, He Q (2012) Electrochemical synthesis, characterization and electrochromic properties of a copolymer based on 1,4-bis(2-thienyl)naphthalene and pyrene. Optic Mater 34:1095-1101
    • (2012) Optic Mater , vol.34 , pp. 1095-1101
    • Wang, B.1    Zhao, J.2    Cui, C.3    Wang, M.4    Wang, Z.5    He, Q.6
  • 37
    • 28044458519 scopus 로고    scopus 로고
    • Electrochemical polymerization of pyrene in the electrolyte of boron trifluoride diethyl etherate containing trifluoroacetic acid and polyethylene glycol oligomer
    • 10.1016/j.jelechem.2005.10.020 1:CAS:528:DC%2BD2MXht1KksbvI
    • Lu G, Shi G (2006) Electrochemical polymerization of pyrene in the electrolyte of boron trifluoride diethyl etherate containing trifluoroacetic acid and polyethylene glycol oligomer. J Electroanal Chem 586:154-160
    • (2006) J Electroanal Chem , vol.586 , pp. 154-160
    • Lu, G.1    Shi, G.2
  • 38
    • 34249936954 scopus 로고    scopus 로고
    • Electrochromic properties of a novel low band gap conductive copolymer
    • 10.1016/j.electacta.2007.04.083 1:CAS:528:DC%2BD2sXmt1Kisro%3D
    • Yigitsoy B, Varis S, Tanyeli C, Akhmedov IM, Toppare L (2007) Electrochromic properties of a novel low band gap conductive copolymer. Electrochim Acta 52:6561-6568
    • (2007) Electrochim Acta , vol.52 , pp. 6561-6568
    • Yigitsoy, B.1    Varis, S.2    Tanyeli, C.3    Akhmedov, I.M.4    Toppare, L.5
  • 39
    • 38149080382 scopus 로고    scopus 로고
    • Synthesis and characterization of metal nanoparticle embedded conducting polymer-polyoxometalate composites
    • 10.1007/s11671-007-9107-z 1:CAS:528:DC%2BD1cXlslejsLo%3D
    • Kishore PS, Viswanathan B, Varadarajan TK (2008) Synthesis and characterization of metal nanoparticle embedded conducting polymer- polyoxometalate composites. Nanoscale Res Lett 3:14-20
    • (2008) Nanoscale Res Lett , vol.3 , pp. 14-20
    • Kishore, P.S.1    Viswanathan, B.2    Varadarajan, T.K.3
  • 40
    • 79961021815 scopus 로고    scopus 로고
    • Electrochemically synthesized nano size copolymer, poly(aniline-co-ethyl 4-aminobenzoate) and its spectroelectrochemical studies
    • 10.1016/j.polymer.2011.06.017 1:CAS:528:DC%2BC3MXps1Whsbs%3D
    • Sasikumar R, Manisankar P (2011) Electrochemically synthesized nano size copolymer, poly(aniline-co-ethyl 4-aminobenzoate) and its spectroelectrochemical studies. Polymer 52:3710-3716
    • (2011) Polymer , vol.52 , pp. 3710-3716
    • Sasikumar, R.1    Manisankar, P.2
  • 41
    • 14844325773 scopus 로고    scopus 로고
    • Hydrazine detection by polyaniline using fluorinated alcohol additives
    • 10.1021/cm0484091 1:CAS:528:DC%2BD2MXhtFSktLw%3D
    • Virji S, Kaner RB, Weiller BH (2005) Hydrazine detection by polyaniline using fluorinated alcohol additives. Chem Mater 17:1256-1260
    • (2005) Chem Mater , vol.17 , pp. 1256-1260
    • Virji, S.1    Kaner, R.B.2    Weiller, B.H.3
  • 42
    • 0034963965 scopus 로고    scopus 로고
    • States of water in different hydrophilic polymers - DSR and FTIR studies
    • 10.1016/S0032-3861(01)00358-5 1:CAS:528:DC%2BD3MXkvFWgtr0%3D
    • Ping ZH, Nguyen QT, Chen SM, Zhou JQ, Ding YD (2001) States of water in different hydrophilic polymers - DSR and FTIR studies. Polymer 42:8461-8467
    • (2001) Polymer , vol.42 , pp. 8461-8467
    • Ping, Z.H.1    Nguyen, Q.T.2    Chen, S.M.3    Zhou, J.Q.4    Ding, Y.D.5
  • 43
    • 18844460455 scopus 로고    scopus 로고
    • Novel coated-wire membrane sensor based on bis(acetylacetonato) cadmium(II) for the determination of chromate ions
    • 10.1007/s00604-005-0319-6 1:CAS:528:DC%2BD2MXktlCit7w%3D
    • Ardakani MM, Dastanpour A, Salavati-Niasari M (2005) Novel coated-wire membrane sensor based on bis(acetylacetonato) cadmium(II) for the determination of chromate ions. Microchim Acta 150:67-72
    • (2005) Microchim Acta , vol.150 , pp. 67-72
    • Ardakani, M.M.1    Dastanpour, A.2    Salavati-Niasari, M.3
  • 44
    • 0037015136 scopus 로고    scopus 로고
    • Selective fluoride recognition and potentiometric properties of ion-selective electrodes based on bis(halodiphenylstannyl)alkanes
    • 10.1016/S0003-2670(02)00534-2
    • Perdikaki K, Tsagkatakis I, Chaniotakis NA, Altmann R, Jurkschat K, Reeske G (2002) Selective fluoride recognition and potentiometric properties of ion-selective electrodes based on bis(halodiphenylstannyl)alkanes. Anal Chim Acta 67:197-204
    • (2002) Anal Chim Acta , vol.67 , pp. 197-204
    • Perdikaki, K.1    Tsagkatakis, I.2    Chaniotakis, N.A.3    Altmann, R.4    Jurkschat, K.5    Reeske, G.6
  • 45
    • 84855258480 scopus 로고    scopus 로고
    • Bio-mimetic cadmium ion imprinted polymer based potentiometric nano-composite sensor
    • 1:CAS:528:DC%2BC3MXhs1Khu7%2FL
    • Ganjali H, Ganjali MR, Alizadeh T, Faridbod F, Norouzi P (2011) Bio-mimetic cadmium ion imprinted polymer based potentiometric nano-composite sensor. Int J Electrochem Sci 6:6085-6093
    • (2011) Int J Electrochem Sci , vol.6 , pp. 6085-6093
    • Ganjali, H.1    Ganjali, M.R.2    Alizadeh, T.3    Faridbod, F.4    Norouzi, P.5
  • 47
    • 79952043437 scopus 로고    scopus 로고
    • Synthesis, characterization and analytical application of nano-composite cation-exchange material, poly-o-toluidine Ce(IV) phosphate: Its application in making Cd(II) ion selective membrane electrode
    • 10.1016/j.solidstatesciences.2010.12.026 1:CAS:528:DC%2BC3MXisV2gtro%3D
    • Khan AA, Akhtar T (2011) Synthesis, characterization and analytical application of nano-composite cation-exchange material, poly-o-toluidine Ce(IV) phosphate: its application in making Cd(II) ion selective membrane electrode. Solid State Sci 13:559-568
    • (2011) Solid State Sci , vol.13 , pp. 559-568
    • Khan, A.A.1    Akhtar, T.2
  • 48
    • 71749116813 scopus 로고    scopus 로고
    • Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry
    • 10.1016/j.jhazmat.2009.07.003 1:CAS:528:DC%2BD1MXhtlektrnO
    • Shamsipur M, Dezaki AS, Akhond M, Sharghi H, Paziraee Z, Alizadeh K (2009) Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry. J Hazard M 172:566-573
    • (2009) J Hazard M , vol.172 , pp. 566-573
    • Shamsipur, M.1    Dezaki, A.S.2    Akhond, M.3    Sharghi, H.4    Paziraee, Z.5    Alizadeh, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.