메뉴 건너뛰기




Volumn 172, Issue 2-3, 2009, Pages 566-573

Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry

Author keywords

Cadmium ion selective electrodes; Coated graphite and coated wire; Flow injection; Potentiometry; PVC membrane; Sulfur containing macrocyclic diamide

Indexed keywords

CADMIUM ION-SELECTIVE ELECTRODES; CADMIUM IONS; COATED WIRES; DIAMIDES; FLOW INJECTION; MACROCYCLICS; POTENTIOMETRY; PVC-MEMBRANE;

EID: 71749116813     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2009.07.003     Document Type: Article
Times cited : (25)

References (67)
  • 2
    • 0032099044 scopus 로고    scopus 로고
    • Carrier based ion-selective electrodes and bulk optodes. 2. Ionophores and potentiometric and optical sensors
    • Buhlmann P., Pretsch E., and Bakker E. Carrier based ion-selective electrodes and bulk optodes. 2. Ionophores and potentiometric and optical sensors. Chem. Rev. 98 (1998) 1593-1678
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1678
    • Buhlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 3
    • 34248143063 scopus 로고    scopus 로고
    • Synthesis, coordination properties, an analytical applications of mixed donor macrocycles containing the 1,10-phenanthroline sub-unit
    • Lippolis V., and Shamsipur M. Synthesis, coordination properties, an analytical applications of mixed donor macrocycles containing the 1,10-phenanthroline sub-unit. J. Iran Chem. Soc. 3 (2006) 105-127
    • (2006) J. Iran Chem. Soc. , vol.3 , pp. 105-127
    • Lippolis, V.1    Shamsipur, M.2
  • 5
    • 0031244946 scopus 로고    scopus 로고
    • Difunctional derivatives of bis(m-phenylene)-32-crown-10
    • Gibson H.W., and Nagvekar D.S. Difunctional derivatives of bis(m-phenylene)-32-crown-10. Can. J. Chem. 75 (1997) 1375-1384
    • (1997) Can. J. Chem. , vol.75 , pp. 1375-1384
    • Gibson, H.W.1    Nagvekar, D.S.2
  • 6
    • 0027298499 scopus 로고
    • Efficient synthesis of a range of benzo-substituted macrocyclic diamides
    • Ibrahim Y.A., and Elwahy A.H.M. Efficient synthesis of a range of benzo-substituted macrocyclic diamides. Synthesis (1993) 503-508
    • (1993) Synthesis , pp. 503-508
    • Ibrahim, Y.A.1    Elwahy, A.H.M.2
  • 7
    • 0028861645 scopus 로고
    • Efficient synthesis of macrocyclic diamides
    • Sharghi H., and Eshghi H. Efficient synthesis of macrocyclic diamides. Tetrahedron 51 (1995) 913-922
    • (1995) Tetrahedron , vol.51 , pp. 913-922
    • Sharghi, H.1    Eshghi, H.2
  • 8
    • 0030011362 scopus 로고    scopus 로고
    • Kinetics of oxidation of cyclic alcohols by quinolinium dichromate
    • Fukada N., Ohtsu T., Miwa M., Mashino M., and Takeda Y. Kinetics of oxidation of cyclic alcohols by quinolinium dichromate. Bull. Chem. Soc. Jpn. 69 (1996) 1397-1401
    • (1996) Bull. Chem. Soc. Jpn. , vol.69 , pp. 1397-1401
    • Fukada, N.1    Ohtsu, T.2    Miwa, M.3    Mashino, M.4    Takeda, Y.5
  • 9
    • 0033321955 scopus 로고    scopus 로고
    • Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide
    • Shamsipur M., Rouhani S., Ganjali M.R., Sharghi H., and Eshghi H. Zinc-selective membrane potentiometric sensor based on a recently synthesized benzo-substituted macrocyclic diamide. Sens. Actuators B 59 (1999) 30-34
    • (1999) Sens. Actuators B , vol.59 , pp. 30-34
    • Shamsipur, M.1    Rouhani, S.2    Ganjali, M.R.3    Sharghi, H.4    Eshghi, H.5
  • 10
    • 0033231372 scopus 로고    scopus 로고
    • Strontium-selective membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides
    • Shamsipur M., Rouhani S., Sharghi H., Ganjali M.R., and Eshghi H. Strontium-selective membrane electrodes based on some recently synthesized benzo-substituted macrocyclic diamides. Anal. Chem. 71 (1999) 4938-4943
    • (1999) Anal. Chem. , vol.71 , pp. 4938-4943
    • Shamsipur, M.1    Rouhani, S.2    Sharghi, H.3    Ganjali, M.R.4    Eshghi, H.5
  • 11
    • 34248167190 scopus 로고    scopus 로고
    • 1,10-Diaza-5,5-benzo-4,7-dioxacyclohexadecane-2,9-dione as a neutral ionophore for a selective PVC-membrane potentiometric sensor for strontium ion
    • Shamsipur M., Kazemi S.Y., and Sharghi H. 1,10-Diaza-5,5-benzo-4,7-dioxacyclohexadecane-2,9-dione as a neutral ionophore for a selective PVC-membrane potentiometric sensor for strontium ion. Sensors 7 (2007) 438-447
    • (2007) Sensors , vol.7 , pp. 438-447
    • Shamsipur, M.1    Kazemi, S.Y.2    Sharghi, H.3
  • 12
  • 13
    • 0035206684 scopus 로고    scopus 로고
    • Cesium-selective membrane electrode based on a recently synthesized 16-membered macrocyclic diamide
    • Shamsipur M., Kazemi S.Y., Sharghi H., and Niknam K. Cesium-selective membrane electrode based on a recently synthesized 16-membered macrocyclic diamide. Anal. Bioanal. Chem. 371 (2001) 1104-1108
    • (2001) Anal. Bioanal. Chem. , vol.371 , pp. 1104-1108
    • Shamsipur, M.1    Kazemi, S.Y.2    Sharghi, H.3    Niknam, K.4
  • 14
    • 0035429671 scopus 로고    scopus 로고
    • The synthesis of 1,4-diaza-2,3,8,9-dibenzo-7,10-dioxacyclododecane-5,12-dione and its use in calcium-selective carbon paste electrodes
    • Shamsipur M., Khayatian G., Kazemi S.Y., Niknam K., and Sharghi H. The synthesis of 1,4-diaza-2,3,8,9-dibenzo-7,10-dioxacyclododecane-5,12-dione and its use in calcium-selective carbon paste electrodes. J. Incl. Phenom. 40 (2001) 303-307
    • (2001) J. Incl. Phenom. , vol.40 , pp. 303-307
    • Shamsipur, M.1    Khayatian, G.2    Kazemi, S.Y.3    Niknam, K.4    Sharghi, H.5
  • 15
    • 0037138251 scopus 로고    scopus 로고
    • A new PVC-membrane electrode based on thia-substituted macrocyclic diamide for selective potentiometric determination of silver ion
    • Shamsipur M., Kazemi S.Y., Niknam K., and Sharghi H. A new PVC-membrane electrode based on thia-substituted macrocyclic diamide for selective potentiometric determination of silver ion. Bull. Korean Chem. Soc. 23 (2002) 53-58
    • (2002) Bull. Korean Chem. Soc. , vol.23 , pp. 53-58
    • Shamsipur, M.1    Kazemi, S.Y.2    Niknam, K.3    Sharghi, H.4
  • 16
    • 0036305205 scopus 로고    scopus 로고
    • Cobalt(II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclic diamide
    • Shamsipur M., Rouhani S., Poursaberi T., Ganjali M.R., Sharghi H., and Niknam K. Cobalt(II)-selective coated graphite PVC-membrane electrode based on a recently synthesized dibenzopyridino-substituted macrocyclic diamide. Electroanalysis 14 (2002) 729-735
    • (2002) Electroanalysis , vol.14 , pp. 729-735
    • Shamsipur, M.1    Rouhani, S.2    Poursaberi, T.3    Ganjali, M.R.4    Sharghi, H.5    Niknam, K.6
  • 18
    • 33947581025 scopus 로고    scopus 로고
    • A novel flow-injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion
    • Shamsipur M., Mizani F., Mousavi M.F., Alizadeh N., Alizadeh K., Eshghi H., and Karami H. A novel flow-injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion. Anal. Chim. Acta 589 (2007) 22-32
    • (2007) Anal. Chim. Acta , vol.589 , pp. 22-32
    • Shamsipur, M.1    Mizani, F.2    Mousavi, M.F.3    Alizadeh, N.4    Alizadeh, K.5    Eshghi, H.6    Karami, H.7
  • 19
    • 34547644625 scopus 로고    scopus 로고
    • Highly selective and sensitive membrane sensors for copper(II) ion based on a new benzo-substituted macrocyclic diamide 6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioxatriaza cyclopentadecine-3,11(4H,12H)-dione
    • Shamsipur M., Mizani F., Saboury A.A., Sharghi H., and Khalifeh R. Highly selective and sensitive membrane sensors for copper(II) ion based on a new benzo-substituted macrocyclic diamide 6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioxatriaza cyclopentadecine-3,11(4H,12H)-dione. Electroanalysis 19 (2007) 587-590
    • (2007) Electroanalysis , vol.19 , pp. 587-590
    • Shamsipur, M.1    Mizani, F.2    Saboury, A.A.3    Sharghi, H.4    Khalifeh, R.5
  • 22
    • 0033668106 scopus 로고    scopus 로고
    • PVC based monoaza-18-crown-6 membrane potentiometrics for cadmium
    • Gupta V.K., Mangla R., and Kumar P. PVC based monoaza-18-crown-6 membrane potentiometrics for cadmium. Electroanalysis 12 (2000) 752-756
    • (2000) Electroanalysis , vol.12 , pp. 752-756
    • Gupta, V.K.1    Mangla, R.2    Kumar, P.3
  • 23
    • 0035951534 scopus 로고    scopus 로고
    • Cadmium ion-selective electrode based on tetrathia-12-crown-4
    • Shamsipur M., and Mashhadizadeh M.H. Cadmium ion-selective electrode based on tetrathia-12-crown-4. Talanta 53 (2001) 1065-1071
    • (2001) Talanta , vol.53 , pp. 1065-1071
    • Shamsipur, M.1    Mashhadizadeh, M.H.2
  • 24
    • 0036499849 scopus 로고    scopus 로고
    • Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor
    • Gupta V.K., Chandra S., and Mangla R. Dicyclohexano-18-crown-6 as active material in PVC matrix membrane for the fabrication of cadmium selective potentiometric sensor. Electrochim. Acta 47 (2002) 1579-1586
    • (2002) Electrochim. Acta , vol.47 , pp. 1579-1586
    • Gupta, V.K.1    Chandra, S.2    Mangla, R.3
  • 25
    • 0038578399 scopus 로고    scopus 로고
    • Synthesis, characterization and analytical applications of a new and novel 'organic-inorganic' composite material as a cation exchanger and Cd(II) ion-selective membrane electrode: polyaniline Sn(IV) tungstoarsenate
    • Khan A.A., and Mezbaul Alam M. Synthesis, characterization and analytical applications of a new and novel 'organic-inorganic' composite material as a cation exchanger and Cd(II) ion-selective membrane electrode: polyaniline Sn(IV) tungstoarsenate. React. Funct. Polymers 55 (2003) 277-290
    • (2003) React. Funct. Polymers , vol.55 , pp. 277-290
    • Khan, A.A.1    Mezbaul Alam, M.2
  • 26
    • 20444489284 scopus 로고    scopus 로고
    • Asymmetrical schiff bases as carriers in PVC membrane electrodes for cadmium(II) ions
    • Mashhadizadeh M.H., Sheikhshoaie I., and Saeid-Nia S. Asymmetrical schiff bases as carriers in PVC membrane electrodes for cadmium(II) ions. Electroanalysis 17 (2005) 648-654
    • (2005) Electroanalysis , vol.17 , pp. 648-654
    • Mashhadizadeh, M.H.1    Sheikhshoaie, I.2    Saeid-Nia, S.3
  • 27
    • 20444413374 scopus 로고    scopus 로고
    • Potentiometric sensors for heavy metals-an overview
    • Gupta V.K. Potentiometric sensors for heavy metals-an overview. Chimia 59 (2005) 209-217
    • (2005) Chimia , vol.59 , pp. 209-217
    • Gupta, V.K.1
  • 29
    • 33748982995 scopus 로고    scopus 로고
    • PVC based membranes of dicyclohexano-24-crown-8 as Cd(II)-selective sensor
    • Gupta V.K., Jain A.K., and Kumar P. PVC based membranes of dicyclohexano-24-crown-8 as Cd(II)-selective sensor. Electrochim. Acta 52 (2006) 736-741
    • (2006) Electrochim. Acta , vol.52 , pp. 736-741
    • Gupta, V.K.1    Jain, A.K.2    Kumar, P.3
  • 30
    • 33846178200 scopus 로고    scopus 로고
    • Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes
    • Gupta V.K., Singh A.K., and Gupta B. Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes. Anal. Chim. Acta 583 (2007) 340-348
    • (2007) Anal. Chim. Acta , vol.583 , pp. 340-348
    • Gupta, V.K.1    Singh, A.K.2    Gupta, B.3
  • 31
    • 37349094148 scopus 로고    scopus 로고
    • Electroanalytical studies on cadmium(II) selective potentiometric sensors based on t-butyl thiacalix[4]arene and thiacalix[4]arene in poly(vinyl chloride)
    • Gupta V.K., Jain A.K., Ludwig R., and Maheshwari G. Electroanalytical studies on cadmium(II) selective potentiometric sensors based on t-butyl thiacalix[4]arene and thiacalix[4]arene in poly(vinyl chloride). Electrochim. Acta 53 (2008) 2362-2368
    • (2008) Electrochim. Acta , vol.53 , pp. 2362-2368
    • Gupta, V.K.1    Jain, A.K.2    Ludwig, R.3    Maheshwari, G.4
  • 32
    • 54549115155 scopus 로고    scopus 로고
    • Self-assembled mercapto-compound-gold-nanoparticle-modified carbon paste electrode for potentiometric determination of cadmium(II)
    • Mashhadizadeh M.H., Eskandari K., Foroumadi A., and Shafieeb A. Self-assembled mercapto-compound-gold-nanoparticle-modified carbon paste electrode for potentiometric determination of cadmium(II). Electroanalysis 20 (2008) 1891-1896
    • (2008) Electroanalysis , vol.20 , pp. 1891-1896
    • Mashhadizadeh, M.H.1    Eskandari, K.2    Foroumadi, A.3    Shafieeb, A.4
  • 33
    • 41049095680 scopus 로고    scopus 로고
    • A fast response cadmium-selective polymeric membrane electrode based on N,N′-(4-methyl-1,2-phenylene)diquinoline-2-carboxamide as a new neutral carrier
    • Rezaei B., Meghdadi S., and Zarandi R.F. A fast response cadmium-selective polymeric membrane electrode based on N,N′-(4-methyl-1,2-phenylene)diquinoline-2-carboxamide as a new neutral carrier. J. Hazard. Mater. 153 (2008) 179-186
    • (2008) J. Hazard. Mater. , vol.153 , pp. 179-186
    • Rezaei, B.1    Meghdadi, S.2    Zarandi, R.F.3
  • 34
    • 58149505714 scopus 로고    scopus 로고
    • Nano level detection of Cd(II) using poly (vinyl chloride) based membranes of Schiff bases
    • Gupta V.K., Al Khayat M., Singh A.K., and Pal M.K. Nano level detection of Cd(II) using poly (vinyl chloride) based membranes of Schiff bases. Anal. Chim. Acta 634 (2009) 36-43
    • (2009) Anal. Chim. Acta , vol.634 , pp. 36-43
    • Gupta, V.K.1    Al Khayat, M.2    Singh, A.K.3    Pal, M.K.4
  • 37
    • 40749143195 scopus 로고    scopus 로고
    • Flow-injection potentiometry by a novel coated graphite electrode based on 5-(9-anthracenylmethyl)-5-aza-2,8-dithia[9],(2,9)-1,10-phenanthrolino-phane for the selective determination of uranyl ions
    • Shamsipur M., Mizani F., Alizadeh K., Mousavi M.F., Lippolis V., Garau A., and Caltagirone C. Flow-injection potentiometry by a novel coated graphite electrode based on 5-(9-anthracenylmethyl)-5-aza-2,8-dithia[9],(2,9)-1,10-phenanthrolino-phane for the selective determination of uranyl ions. Sens. Actuators B 130 (2008) 300-309
    • (2008) Sens. Actuators B , vol.130 , pp. 300-309
    • Shamsipur, M.1    Mizani, F.2    Alizadeh, K.3    Mousavi, M.F.4    Lippolis, V.5    Garau, A.6    Caltagirone, C.7
  • 38
    • 0023690581 scopus 로고
    • Preparation and performance of a coated tubular solid-state cadmium-selective electrode in flow-injection analysis
    • van Staden J.F. Preparation and performance of a coated tubular solid-state cadmium-selective electrode in flow-injection analysis. Fresenius Z. Anal. Chem. 331 (1988) 594-598
    • (1988) Fresenius Z. Anal. Chem. , vol.331 , pp. 594-598
    • van Staden, J.F.1
  • 39
    • 0031830281 scopus 로고    scopus 로고
    • Flow-injection potentiometric determination of free cadmium ions with a cadmium ion-selective electrode
    • Trojanowicza M., Alexander P.W., and Hibbertc D.B. Flow-injection potentiometric determination of free cadmium ions with a cadmium ion-selective electrode. Anal. Chim. Acta 370 (1998) 267-278
    • (1998) Anal. Chim. Acta , vol.370 , pp. 267-278
    • Trojanowicza, M.1    Alexander, P.W.2    Hibbertc, D.B.3
  • 40
    • 1642307572 scopus 로고    scopus 로고
    • Efficient synthesis of new sulfur macrocyclic diamides
    • Sharghi H., and Paziraee Z. Efficient synthesis of new sulfur macrocyclic diamides. Synthesis (2004) 600-604
    • (2004) Synthesis , pp. 600-604
    • Sharghi, H.1    Paziraee, Z.2
  • 41
    • 4244124993 scopus 로고
    • Complex formation of silver, thallium and alkali cations with dibenzo-30-crown-10 in some nonaqueous solutions
    • Amini M.K., and Shamsipur M. Complex formation of silver, thallium and alkali cations with dibenzo-30-crown-10 in some nonaqueous solutions. Inorg. Chim. Acta 183 (1991) 65-70
    • (1991) Inorg. Chim. Acta , vol.183 , pp. 65-70
    • Amini, M.K.1    Shamsipur, M.2
  • 42
    • 71749094393 scopus 로고    scopus 로고
    • Hyperchem, Release 7.0, Hypercube, Inc, Gainesville, 2002
    • Hyperchem, Release 7.0, Hypercube, Inc., Gainesville, 2002.
  • 44
    • 0037466296 scopus 로고    scopus 로고
    • Ab initio investigations of structural and energetic properties of hindered aryl alkyl ketones
    • Kassaee M.Z., Beigi M., and Arshadi S. Ab initio investigations of structural and energetic properties of hindered aryl alkyl ketones. J. Mol. Struct. (Theochem) 624 (2003) 69-79
    • (2003) J. Mol. Struct. (Theochem) , vol.624 , pp. 69-79
    • Kassaee, M.Z.1    Beigi, M.2    Arshadi, S.3
  • 45
    • 30944447840 scopus 로고    scopus 로고
    • Potentiometric, spectrophotometric, theoretical studies and binding properties of a novel tripodal polycatechol-amine ligand with lanthanide(III) ions
    • Sahoo S.K., Baral M., and Kanungo B.K. Potentiometric, spectrophotometric, theoretical studies and binding properties of a novel tripodal polycatechol-amine ligand with lanthanide(III) ions. Polyhedron 25 (2006) 722-736
    • (2006) Polyhedron , vol.25 , pp. 722-736
    • Sahoo, S.K.1    Baral, M.2    Kanungo, B.K.3
  • 46
    • 47549111897 scopus 로고    scopus 로고
    • Three green luminescent cadmium complexes containing 8-aminoquinoline ligands: syntheses, crystal structures, emission spectra and DFT calculations
    • Xu H., Huang L.-F., Guo L.-M., Zhang Y.-G., Ren X.-M., Song Y., and Xie J. Three green luminescent cadmium complexes containing 8-aminoquinoline ligands: syntheses, crystal structures, emission spectra and DFT calculations. J. Luminesc. 128 (2008) 1665-1672
    • (2008) J. Luminesc. , vol.128 , pp. 1665-1672
    • Xu, H.1    Huang, L.-F.2    Guo, L.-M.3    Zhang, Y.-G.4    Ren, X.-M.5    Song, Y.6    Xie, J.7
  • 47
    • 0000020499 scopus 로고
    • Anion-selective membrane electrodes based on metalloporphyrins: the influence of lipophilic anionic and cationic sites on potentiometric selectivity
    • Bakker E., Malinowska E., Schaller R.D., and Meyerhoff M.E. Anion-selective membrane electrodes based on metalloporphyrins: the influence of lipophilic anionic and cationic sites on potentiometric selectivity. Talanta 41 (1994) 881-890
    • (1994) Talanta , vol.41 , pp. 881-890
    • Bakker, E.1    Malinowska, E.2    Schaller, R.D.3    Meyerhoff, M.E.4
  • 48
    • 0031917109 scopus 로고    scopus 로고
    • Chloride-selective membranes prepared with different matrices including polymers obtained by the sol-gel method
    • Kim W., Sung D.D., Cha G.S., and Park S.B. Chloride-selective membranes prepared with different matrices including polymers obtained by the sol-gel method. Analyst 123 (1998) 379-382
    • (1998) Analyst , vol.123 , pp. 379-382
    • Kim, W.1    Sung, D.D.2    Cha, G.S.3    Park, S.B.4
  • 49
    • 84986384755 scopus 로고
    • Preparation of neutral ionophores for alkali and alkaline earth metal cations and their application in ion selective membrane electrodes
    • Ammann D., Bissig R., Guggi M., Pretsch E., Simon W., Borowitz I.J., and Weiss L. Preparation of neutral ionophores for alkali and alkaline earth metal cations and their application in ion selective membrane electrodes. Helv. Chim. Acta 58 (1975) 1535-1548
    • (1975) Helv. Chim. Acta , vol.58 , pp. 1535-1548
    • Ammann, D.1    Bissig, R.2    Guggi, M.3    Pretsch, E.4    Simon, W.5    Borowitz, I.J.6    Weiss, L.7
  • 50
    • 0000644872 scopus 로고    scopus 로고
    • Lead-selective membrane electrodes based on dithiophenediazacrown ether derivatives
    • Yang X., Kumar N., Chi H., Hibbert D.B., and Alexander P.N.W. Lead-selective membrane electrodes based on dithiophenediazacrown ether derivatives. Electroanalysis 9 (1997) 549-553
    • (1997) Electroanalysis , vol.9 , pp. 549-553
    • Yang, X.1    Kumar, N.2    Chi, H.3    Hibbert, D.B.4    Alexander, P.N.W.5
  • 51
    • 0001738932 scopus 로고
    • Ionic additives for ion-selective electrodes based on electrically charged carriers
    • Schaller U., Bakker E., Spichiger U.E., and Pretsch E. Ionic additives for ion-selective electrodes based on electrically charged carriers. Anal. Chem. 66 (1994) 391-398
    • (1994) Anal. Chem. , vol.66 , pp. 391-398
    • Schaller, U.1    Bakker, E.2    Spichiger, U.E.3    Pretsch, E.4
  • 52
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral, carriers
    • Ammann D., Pretsch E., Simon W., Lindner E., Bezegh A., and Pungor E. Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral, carriers. Anal. Chim. Acta 171 (1985) 119-129
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindner, E.4    Bezegh, A.5    Pungor, E.6
  • 53
    • 0001377914 scopus 로고
    • Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes
    • Eugster E., Gehring P.M., Morf W.E., Spichiger U., and Simon W. Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodes. Anal. Chem. 63 (1991) 2285-2289
    • (1991) Anal. Chem. , vol.63 , pp. 2285-2289
    • Eugster, E.1    Gehring, P.M.2    Morf, W.E.3    Spichiger, U.4    Simon, W.5
  • 54
    • 0027325714 scopus 로고
    • Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors
    • Rostazin T., Bakker E., Suzuki K., and Simon W. Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors. Anal. Chim. Acta 280 (1993) 197-208
    • (1993) Anal. Chim. Acta , vol.280 , pp. 197-208
    • Rostazin, T.1    Bakker, E.2    Suzuki, K.3    Simon, W.4
  • 56
    • 84987539052 scopus 로고
    • Catalysis of ion transfer by tetraphenylborates in neutral carrier-based ion-selective electrodes
    • Gehring P.M., Morf W.E., Welti M., Pretsch E., and Simon W. Catalysis of ion transfer by tetraphenylborates in neutral carrier-based ion-selective electrodes. Helv. Chim. Acta 73 (1990) 203-212
    • (1990) Helv. Chim. Acta , vol.73 , pp. 203-212
    • Gehring, P.M.1    Morf, W.E.2    Welti, M.3    Pretsch, E.4    Simon, W.5
  • 57
    • 84942509898 scopus 로고
    • 2+ ion by a cooperative carrier composed of 1,10-diaza-18-crown-6 and palmitic acid
    • 2+ ion by a cooperative carrier composed of 1,10-diaza-18-crown-6 and palmitic acid. Bull. Chem. Soc. Jpn. 65 (1992) 2779-2783
    • (1992) Bull. Chem. Soc. Jpn. , vol.65 , pp. 2779-2783
    • Dadfarnia, S.1    Shamsipur, M.2
  • 58
    • 0030596622 scopus 로고    scopus 로고
    • 2+ ion by a cooperative carrier composed of aza-18-crown-6 and palmitic acid
    • 2+ ion by a cooperative carrier composed of aza-18-crown-6 and palmitic acid. J. Membr. Sci. 117 (1996) 221-226
    • (1996) J. Membr. Sci. , vol.117 , pp. 221-226
    • Akhond, M.1    Shamsipur, M.2
  • 59
    • 84988122977 scopus 로고
    • Studies on the phase boundaries and the significance of ionic sites of liquid membrane ion-selective electrodes
    • Buhlmann P., Yajima S., Tohda K., Umezawa K., Nishizawa S., and Umezawa Y. Studies on the phase boundaries and the significance of ionic sites of liquid membrane ion-selective electrodes. Electroanalysis 7 (1995) 811-816
    • (1995) Electroanalysis , vol.7 , pp. 811-816
    • Buhlmann, P.1    Yajima, S.2    Tohda, K.3    Umezawa, K.4    Nishizawa, S.5    Umezawa, Y.6
  • 60
    • 0034161659 scopus 로고    scopus 로고
    • Salicylate-selective electrodes based on Al(III) and Sn(IV) salophens
    • Shahrokhian S., Amini M.K., Kia R., and Tangestaninejad S. Salicylate-selective electrodes based on Al(III) and Sn(IV) salophens. Anal. Chem. 72 (2000) 956-962
    • (2000) Anal. Chem. , vol.72 , pp. 956-962
    • Shahrokhian, S.1    Amini, M.K.2    Kia, R.3    Tangestaninejad, S.4
  • 63
    • 38549105511 scopus 로고    scopus 로고
    • Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report)
    • Lindner E., and Umezawa Y. Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report). Pure Appl. Chem. 80 (2008) 85-104
    • (2008) Pure Appl. Chem. , vol.80 , pp. 85-104
    • Lindner, E.1    Umezawa, Y.2
  • 64
    • 0032502279 scopus 로고    scopus 로고
    • Lead ion-selective membrane electrodes based on some recently synthesized 9,10-anthraquinone derivatives
    • Tavakkoli N., Khojasteh Z., Sharghi H., and Shamsipur M. Lead ion-selective membrane electrodes based on some recently synthesized 9,10-anthraquinone derivatives. Anal. Chim. Acta 360 (1998) 203-208
    • (1998) Anal. Chim. Acta , vol.360 , pp. 203-208
    • Tavakkoli, N.1    Khojasteh, Z.2    Sharghi, H.3    Shamsipur, M.4
  • 66
    • 0031682899 scopus 로고    scopus 로고
    • Flow-injection potentiometry by poly(vinyl chloride)-membrane electrodes with substituted azacrown ionophores for the determination of lead(II) and mercury(II) ions
    • Yang X., Hibbert D.B., and Alexander P.W. Flow-injection potentiometry by poly(vinyl chloride)-membrane electrodes with substituted azacrown ionophores for the determination of lead(II) and mercury(II) ions. Anal. Chim. Acta 372 (1998) 387-398
    • (1998) Anal. Chim. Acta , vol.372 , pp. 387-398
    • Yang, X.1    Hibbert, D.B.2    Alexander, P.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.