Is it possible to improve the accuracy of implants inserted with a stereolithographic surgical guide by reducing the tolerance between mechanical components?
Accuracy of two stereolithographic guide systems for computer-aided implant placement: A computed tomography-based clinical comparative study
V. Arisan, Z.C. Karabuda, and T. Özdemir Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study J Periodontol 81 2010 43 51
Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: A review of the literature
10.1111/j.1708-8208.2010.00275.x
J. D'Haese, T. Van De Velde, A. Komiyama, M. Hultin, and H. De Bruyn Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature Clin Implant Dent Relat Res 14 2012 321 335 10.1111/j.1708-8208.2010. 00275.x
Accuracy of virtually planned and template guided implant surgery on edentate patients
10.1111/j.1708-8208.2010.00285.x May 11 [Epub ahead of print]
A. Pettersson, A. Komiyama, M. Hultin, K. Näsström, and B. Klinge Accuracy of virtually planned and template guided implant surgery on edentate patients Clin Implant Dent Relat Res 2010 10.1111/j.1708-8208.2010. 00285.x May 11 [Epub ahead of print]
A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry
D. Schneider, P. Marquardt, M. Zwahlen, and R.E. Jung A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry Clin Oral Implants Res 20 2009 73 86
Accuracy of two stereolithographic surgical templates: A retrospective study
10.1111/j.1708-8208.2011.00369.x July 11 [Epub ahead of print]
M. Cassetta, M. Giansanti, A. Di Mambro, S. Calasso, and E. Barbato Accuracy of two stereolithographic surgical templates: a retrospective study Clin Implant Dent Relat Res 2011 10.1111/j.1708-8208.2011.00369.x July 11 [Epub ahead of print]
The intrinsic error of a stereolithographic surgical template in implant guided surgery
10.1016/j.ijom.2012.06.010 July 11 [Epub ahead of print]
M. Cassetta, A. Di Mambro, M. Giansanti, L.V. Stefanelli, and Cavallini C The intrinsic error of a stereolithographic surgical template in implant guided surgery Int J Oral Maxillofac Surg 2012 10.1016/j.ijom.2012.06.010 July 11 [Epub ahead of print]
Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide
M. Cassetta, L.V. Stefanelli, M. Giansanti, A. Di Mambro, and S. Calasso Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide Int J Oral Maxillofac Surg 40 2011 1377 1387
A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae
10.1111/j.1708-8208.2009.00255.x
J. D'Haese, T. Van De Velde, L. Elaut, and H. De Bruyn A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae Clin Implant Dent Relat Res 14 2012 293 303 10.1111/j.1708-8208.2009.00255.x