메뉴 건너뛰기




Volumn 40, Issue 12, 2011, Pages 1377-1387

Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide

Author keywords

aided; complications; computer; implantology; stereolithographic; surgi guide

Indexed keywords

ACCURACY; ADULT; ARTICLE; CLINICAL ARTICLE; COMPUTER AIDED IMPLANTOLOGY; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; DEPTH PERCEPTION; FEMALE; HUMAN; MALE; MANDIBLE PROSTHESIS; MAXILLA PROSTHESIS; OSTEOTOMY; POSTOPERATIVE COMPLICATION; PROSTHESIS; STEREOLITHOGRAPHY; THREE DIMENSIONAL IMAGING; TOOTH IMPLANTATION;

EID: 82955212995     PISSN: 09015027     EISSN: 13990020     Source Type: Journal    
DOI: 10.1016/j.ijom.2011.09.009     Document Type: Article
Times cited : (67)

References (20)
  • 1
    • 77649199482 scopus 로고    scopus 로고
    • Accuracy of two stereolithographic guide system for computer-aided implant placement: A computed tomography-based clinical comparative study
    • V. Arisan, Z.C. Karabuda, and T. Özdemir Accuracy of two stereolithographic guide system for computer-aided implant placement: a computed tomography-based clinical comparative study J Periodontol 81 2010 43 51
    • (2010) J Periodontol , vol.81 , pp. 43-51
    • Arisan, V.1    Karabuda, Z.C.2    Özdemir, T.3
  • 2
    • 82255183391 scopus 로고    scopus 로고
    • A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae
    • Epub ahead of print
    • D'Haese J, van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res 2009, Epub ahead of print.
    • (2009) Clin Implant Dent Relat Res
    • D'Haese, J.1    Van De Velde, T.2    Elaut, L.3    De Bruyn, H.4
  • 3
    • 79953864104 scopus 로고    scopus 로고
    • Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: A review of the literature
    • Epub ahead of print
    • D'Haese J, van De Velde T, Komiyama A, Hultin M, De Bruyn H. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin Implant Dent Relat Res 2010, Epub ahead of print.
    • (2010) Clin Implant Dent Relat Res
    • D'Haese, J.1    Van De Velde, T.2    Komiyama, A.3    Hultin, M.4    De Bruyn, H.5
  • 4
    • 49149088692 scopus 로고    scopus 로고
    • Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: Clinical data from 94 implants
    • A.E. Ersoy, I. Turkyilmaz, O. Ozan, and E.A. McGlumphy Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants J Periodontol 79 2008 1339 1345
    • (2008) J Periodontol , vol.79 , pp. 1339-1345
    • Ersoy, A.E.1    Turkyilmaz, I.2    Ozan, O.3    McGlumphy, E.A.4
  • 5
    • 75549092189 scopus 로고    scopus 로고
    • Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry
    • C.H.F. Hämmerle, P. Stone, R.E. Jung, T. Kapos, and N. Brodala Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry Int J Oral Maxillofac Implants 24 Suppl. 2009 126 129
    • (2009) Int J Oral Maxillofac Implants , vol.24 , Issue.SUPPL. , pp. 126-129
    • Hämmerle, C.H.F.1    Stone, P.2    Jung, R.E.3    Kapos, T.4    Brodala, N.5
  • 6
    • 33644800726 scopus 로고    scopus 로고
    • Trigeminal nerve injuries after mandibular implant placement - Practical knowledge for clinicians
    • F. Hegedus, and R.J. Diecidue Trigeminal nerve injuries after mandibular implant placement-Practical knowledge for clinicians Int J Oral Maxillofac Implants 21 2006 111 116 (Pubitemid 43350994)
    • (2006) International Journal of Oral and Maxillofacial Implants , vol.21 , Issue.1 , pp. 111-116
    • Hegedus, F.1    Diecidue, R.J.2
  • 7
    • 68949088397 scopus 로고    scopus 로고
    • Digitally planned, immediately loaded dental implants with prefabricated prosthesis in the reconstruction of edentulous maxillae: A 1-year prospective, multicenter study
    • B. Johansson, B. Friberg, and H. Nilson Digitally planned, immediately loaded dental implants with prefabricated prosthesis in the reconstruction of edentulous maxillae: a 1-year prospective, multicenter study Clin Implant Dent Relat Res 11 2009 194 200
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 194-200
    • Johansson, B.1    Friberg, B.2    Nilson, H.3
  • 9
    • 44949125661 scopus 로고    scopus 로고
    • Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery
    • A. Komiyama, B. Klinge, and M. Hultin Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery Clin Oral Implants Res 19 2008 677 685
    • (2008) Clin Oral Implants Res , vol.19 , pp. 677-685
    • Komiyama, A.1    Klinge, B.2    Hultin, M.3
  • 10
    • 77956021630 scopus 로고    scopus 로고
    • Computer-guided implant dentistry for precise implant placement: Combining specialized stereolithographically generated drilling guides and surgical implant instrumentation
    • G.A. Mandelaris, A.L. Rosenfeld, S.D. King, and M.L. Nevins Computer-guided implant dentistry for precise implant placement: combining specialized stereolithographically generated drilling guides and surgical implant instrumentation Int J Periodontics Restorative Dent 30 2010 274 281
    • (2010) Int J Periodontics Restorative Dent , vol.30 , pp. 274-281
    • Mandelaris, G.A.1    Rosenfeld, A.L.2    King, S.D.3    Nevins, M.L.4
  • 11
    • 84864506897 scopus 로고    scopus 로고
    • Accuracy of virtually planned and template guided implant surgery on edentate patients
    • 10.1111/J. 1708-8208.2010.00285.x
    • A. Pettersson, A. Komiyama, M. Hultin, K. Näsström, and B. Klinge Accuracy of virtually planned and template guided implant surgery on edentate patients Clin Implant Dent Relat Res 2010 10.1111/J. 1708-8208.2010.00285.x
    • (2010) Clin Implant Dent Relat Res
    • Pettersson, A.1    Komiyama, A.2    Hultin, M.3    Näsström, K.4    Klinge, B.5
  • 12
    • 44949184646 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: Optical traking vs. stereolithographic splint system
    • J. Ruppin, A. Popovic, M. Strauss, E. Spüntrup, A. Steiner, and C. Stoll Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical traking vs. stereolithographic splint system Clin Oral Implants Res 19 2008 709 716
    • (2008) Clin Oral Implants Res , vol.19 , pp. 709-716
    • Ruppin, J.1    Popovic, A.2    Strauss, M.3    Spüntrup, E.4    Steiner, A.5    Stoll, C.6
  • 14
    • 68549115350 scopus 로고    scopus 로고
    • A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry
    • D. Schneider, P. Marquardt, M. Zwahlen, and R.E. Jung A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry Clin Oral Implants Res 20 2009 73 86
    • (2009) Clin Oral Implants Res , vol.20 , pp. 73-86
    • Schneider, D.1    Marquardt, P.2    Zwahlen, M.3    Jung, R.E.4
  • 16
    • 69849086316 scopus 로고    scopus 로고
    • Accuracy of computer-aided oral implant surgery: A clinical and radiographic study
    • F. Valente, G. Schiroli, and A. Sbrenna Accuracy of computer-aided oral implant surgery: a clinical and radiographic study Int J Oral Maxillofac Implants 24 2009 234 242
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 234-242
    • Valente, F.1    Schiroli, G.2    Sbrenna, A.3
  • 17
    • 20744446711 scopus 로고    scopus 로고
    • A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: A prospective multicenter study
    • D. van Steenberghe, R. Glauser, U. Blombäck, M. Andersson, F. Schutyser, A. Pettersson, and I. Wendelhag A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study Clin Implant Dent Relat Res 7 2005 111 120
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 111-120
    • Van Steenberghe, D.1    Glauser, R.2    Blombäck, U.3    Andersson, M.4    Schutyser, F.5    Pettersson, A.6    Wendelhag, I.7
  • 19
    • 0037292270 scopus 로고    scopus 로고
    • Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study
    • DOI 10.1054/ijom.2002.0337
    • L. Vrielinck, C. Politis, S. Schepers, M. Pauwels, and I. Naert Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study Int J Oral Maxillofac Surg 32 2003 7 14 (Pubitemid 36284846)
    • (2003) International Journal of Oral and Maxillofacial Surgery , vol.32 , Issue.1 , pp. 7-14
    • Vrielinck, L.1    Politis, C.2    Schepers, S.3    Pauwels, M.4    Naert, I.5
  • 20
    • 48849084356 scopus 로고    scopus 로고
    • Complications of computer-aided-design/computer-aided machining-guided (Nobel-guide) surgical implant placement: An evaluation of early clinical results
    • L.T. Yong, and P.K. Moy Complications of computer-aided-design/computer- aided machining-guided (Nobel-guide) surgical implant placement: an evaluation of early clinical results Clin Implant Dent Relat Res 10 2008 123 127
    • (2008) Clin Implant Dent Relat Res , vol.10 , pp. 123-127
    • Yong, L.T.1    Moy, P.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.