메뉴 건너뛰기




Volumn 55, Issue , 2013, Pages 148-157

Effects of uncertainties in experimental conditions on the estimation of adsorption model parameters in preparative chromatography

Author keywords

Ion exchange chromatography; Model calibration; Modeling; Parameter estimation; Parameter uncertainty; Reversed phase chromatography

Indexed keywords

ADSORPTION CHROMATOGRAPHY; CONCENTRATION DISTRIBUTIONS; CONCENTRATION MEASUREMENT; ION-EXCHANGE CHROMATOGRAPHY; MODEL CALIBRATION; PARAMETER UNCERTAINTY; PREPARATIVE CHROMATOGRAPHY; REVERSED-PHASE CHROMATOGRAPHY;

EID: 84878469802     PISSN: 00981354     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compchemeng.2013.04.013     Document Type: Article
Times cited : (31)

References (24)
  • 2
    • 0030201449 scopus 로고    scopus 로고
    • Solute affinity in ion-exchange displacement chromatography
    • Brooks C.A., Cramer S.M. Solute affinity in ion-exchange displacement chromatography. Chemical Engineering Science 1996, 51:3847-3860.
    • (1996) Chemical Engineering Science , vol.51 , pp. 3847-3860
    • Brooks, C.A.1    Cramer, S.M.2
  • 3
    • 0000512761 scopus 로고
    • Determination of isotherms from chromatographic peak shapes
    • Dose E.V., Jacobson S., Guiochon G. Determination of isotherms from chromatographic peak shapes. Analytical Chemistry 1991, 63:833-839.
    • (1991) Analytical Chemistry , vol.63 , pp. 833-839
    • Dose, E.V.1    Jacobson, S.2    Guiochon, G.3
  • 5
    • 0037008247 scopus 로고    scopus 로고
    • Preparative liquid chromatography
    • Guiochon G. Preparative liquid chromatography. Journal of Chromatography A 2002, 965:129-161.
    • (2002) Journal of Chromatography A , vol.965 , pp. 129-161
    • Guiochon, G.1
  • 6
    • 82955219743 scopus 로고    scopus 로고
    • Separation science is the key to successful biopharmaceuticals
    • Guiochon G., Beaver L. Separation science is the key to successful biopharmaceuticals. Journal of Chromatography A 2011, 1218:8836-8858.
    • (2011) Journal of Chromatography A , vol.1218 , pp. 8836-8858
    • Guiochon, G.1    Beaver, L.2
  • 8
    • 0035885311 scopus 로고    scopus 로고
    • Propagation of uncertainty in high-performance liquid chromatography with UV-vis detection
    • Hibbert D.B., Jiang J., Mulholland M.I. Propagation of uncertainty in high-performance liquid chromatography with UV-vis detection. Analytica Chimica Acta 2001, 443:205-214.
    • (2001) Analytica Chimica Acta , vol.443 , pp. 205-214
    • Hibbert, D.B.1    Jiang, J.2    Mulholland, M.I.3
  • 9
    • 0033150234 scopus 로고    scopus 로고
    • Determination of binary competitive equilibrium isotherms from the individual chromatographic band profiles
    • James F., Sepúlveda M., Charton F., Quiñones I., Guiochon G. Determination of binary competitive equilibrium isotherms from the individual chromatographic band profiles. Chemical Engineering Science 1999, 54:1677-1696.
    • (1999) Chemical Engineering Science , vol.54 , pp. 1677-1696
    • James, F.1    Sepúlveda, M.2    Charton, F.3    Quiñones, I.4    Guiochon, G.5
  • 11
    • 34548230655 scopus 로고    scopus 로고
    • Application of chromatographic theory for process characterization towards validation of an ion-exchange operation
    • Kaltenbrunner O., Giaverini O., Woehle D., Asenjo J. Application of chromatographic theory for process characterization towards validation of an ion-exchange operation. Biotechnology and Bioengineering 2007, 98:201-210.
    • (2007) Biotechnology and Bioengineering , vol.98 , pp. 201-210
    • Kaltenbrunner, O.1    Giaverini, O.2    Woehle, D.3    Asenjo, J.4
  • 12
    • 84878429823 scopus 로고    scopus 로고
    • Model-based optimization of a preparative ion-exchange step for antibody purification
    • Karlsson D., Jakobsson N., Axelsson A., Nilsson B. Model-based optimization of a preparative ion-exchange step for antibody purification. Journal of Chromatography A 2004, 1050:129-135.
    • (2004) Journal of Chromatography A , vol.1050 , pp. 129-135
    • Karlsson, D.1    Jakobsson, N.2    Axelsson, A.3    Nilsson, B.4
  • 13
    • 1542268942 scopus 로고    scopus 로고
    • Methodologies for model calibration to assist the design of a preparative ion-exchange step for antibody purification
    • Karlsson D., Jakobsson N., Brink K.-J., Axelsson A., Nilsson B. Methodologies for model calibration to assist the design of a preparative ion-exchange step for antibody purification. Journal of Chromatography A 2004, 1033:71-82.
    • (2004) Journal of Chromatography A , vol.1033 , pp. 71-82
    • Karlsson, D.1    Jakobsson, N.2    Brink, K.-J.3    Axelsson, A.4    Nilsson, B.5
  • 14
    • 84855346585 scopus 로고    scopus 로고
    • Modelling and optimisation of preparative chromatographic purification of europium
    • Ojala F., Max-Hansen M., Kifle D., Borg N., Nilsson B. Modelling and optimisation of preparative chromatographic purification of europium. Journal of Chromatography A 2012, 1220:21-25.
    • (2012) Journal of Chromatography A , vol.1220 , pp. 21-25
    • Ojala, F.1    Max-Hansen, M.2    Kifle, D.3    Borg, N.4    Nilsson, B.5
  • 16
    • 4644243561 scopus 로고    scopus 로고
    • Influence of the column hold-up time measurement accuracy on the prediction of chromatographic band profiles
    • Sajonz P. Influence of the column hold-up time measurement accuracy on the prediction of chromatographic band profiles. Journal of Chromatography A 2004, 1050:129-135.
    • (2004) Journal of Chromatography A , vol.1050 , pp. 129-135
    • Sajonz, P.1
  • 17
    • 46549087285 scopus 로고    scopus 로고
    • Impact of an error in the column hold-up time for correct adsorption isotherm determination in chromatography: II. Can a wrong column porosity lead to a correct prediction of overloaded elution profiles?
    • Samuelsson J., Zang J., Murunga A., Fornstedt T., Sajonz P. Impact of an error in the column hold-up time for correct adsorption isotherm determination in chromatography: II. Can a wrong column porosity lead to a correct prediction of overloaded elution profiles?. Journal of Chromatography A 2008, 1194:205-212.
    • (2008) Journal of Chromatography A , vol.1194 , pp. 205-212
    • Samuelsson, J.1    Zang, J.2    Murunga, A.3    Fornstedt, T.4    Sajonz, P.5
  • 18
    • 41949103010 scopus 로고    scopus 로고
    • Impact of an error in the column hold-up time for correct adsorption isotherm determination in chromatography: I. Even a small error can lead to a misunderstanding of the retention mechanism
    • Samuelsson J., Fornstedt T., Sajonz P. Impact of an error in the column hold-up time for correct adsorption isotherm determination in chromatography: I. Even a small error can lead to a misunderstanding of the retention mechanism. Journal of Chromatography A 2008, 1189:19-31.
    • (2008) Journal of Chromatography A , vol.1189 , pp. 19-31
    • Samuelsson, J.1    Fornstedt, T.2    Sajonz, P.3
  • 19
    • 2342621494 scopus 로고    scopus 로고
    • Experimental determination of single solute and competitive adsorption isotherms
    • Seidel-Morgenstern A. Experimental determination of single solute and competitive adsorption isotherms. Journal of Chromatography A 2004, 1037:255-272.
    • (2004) Journal of Chromatography A , vol.1037 , pp. 255-272
    • Seidel-Morgenstern, A.1
  • 20
    • 33750554703 scopus 로고    scopus 로고
    • Mathematical modeling of elution curves for a protein mixture in ion exchange chromatography and for the optimal selection of operational conditions
    • Shene C., Lucero A., Andrews B., Asenjo J. Mathematical modeling of elution curves for a protein mixture in ion exchange chromatography and for the optimal selection of operational conditions. Biotechnology and Bioengineering 2006, 95:704-713.
    • (2006) Biotechnology and Bioengineering , vol.95 , pp. 704-713
    • Shene, C.1    Lucero, A.2    Andrews, B.3    Asenjo, J.4
  • 21
    • 84857969029 scopus 로고    scopus 로고
    • Application of genetic algorithms and response surface analysis for the optimization of batch chromatographic systems
    • Treier K., Lester P., Hubbuch J. Application of genetic algorithms and response surface analysis for the optimization of batch chromatographic systems. Biochemical Engineering Journal 2012, 63:66-75.
    • (2012) Biochemical Engineering Journal , vol.63 , pp. 66-75
    • Treier, K.1    Lester, P.2    Hubbuch, J.3
  • 22
    • 1642349588 scopus 로고    scopus 로고
    • Error analysis and performance of different retention models in the transference of data from/to isocratic/gradient elution
    • Vivó-Truyols G., Torres-Lapasió J.R., Garcióa-Alvarez-Coque M.C. Error analysis and performance of different retention models in the transference of data from/to isocratic/gradient elution. Journal of Chromatography A 2003, 1018:169-181.
    • (2003) Journal of Chromatography A , vol.1018 , pp. 169-181
    • Vivó-Truyols, G.1    Torres-Lapasió, J.R.2    Garcióa-Alvarez-Coque, M.C.3
  • 23
    • 0035900205 scopus 로고    scopus 로고
    • Numerical estimation of multicomponent adsorption isotherms in preparative chromatography: implications of experimental error
    • Zhang L., Selker J., Qu A., Velayudhan A. Numerical estimation of multicomponent adsorption isotherms in preparative chromatography: implications of experimental error. Journal of Chromatography A 2001, 934:13-29.
    • (2001) Journal of Chromatography A , vol.934 , pp. 13-29
    • Zhang, L.1    Selker, J.2    Qu, A.3    Velayudhan, A.4
  • 24
    • 84855166398 scopus 로고    scopus 로고
    • Supporting design and control of a reversed phase chromatography step by mechanistic modeling
    • Westerberg K., Borg N., Andersson N., Nilsson B. Supporting design and control of a reversed phase chromatography step by mechanistic modeling. Chemical Engineering & Technology 2012, 35:169-175.
    • (2012) Chemical Engineering & Technology , vol.35 , pp. 169-175
    • Westerberg, K.1    Borg, N.2    Andersson, N.3    Nilsson, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.