Volumn 20, Issue 4, 2013, Pages 242-249

The long leg radiograph is a reliable method of assessing alignment when compared to computer-assisted navigation and computer tomography

Author keywords

Alignment; Computer assisted surgery; Computer tomography; Knee; Long leg radiographs

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BONE RADIOGRAPHY; CLINICAL ARTICLE; COMPUTER ASSISTED NAVIGATION; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; INTERMETHOD COMPARISON; KNEE OSTEOARTHRITIS; LONG LEG RADIOGRAPH; MALE; MECHANICAL ALIGNMENT OF THE KNEE; MUSCULOSKELETAL SYSTEM PARAMETERS; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIATION DOSE; REPRODUCIBILITY; RHEUMATOID ARTHRITIS; TOTAL KNEE REPLACEMENT;

EID: 84878260476     PISSN: 09680160     EISSN: 18735800     Source Type: Journal    
DOI: 10.1016/j.knee.2012.07.009     Document Type: Article
Times cited : (75)

References (44)
  • 1
    • 36749020620 scopus 로고    scopus 로고
    • Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery
    • Mason J.B., Fehring T.K., Estok R., Banel D., Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 2007, 22:1097-1106.
    • (2007) J Arthroplasty , vol.22 , pp. 1097-1106
    • Mason, J.B.1    Fehring, T.K.2    Estok, R.3    Banel, D.4    Fahrbach, K.5
  • 2
    • 33845417222 scopus 로고    scopus 로고
    • Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study
    • Stulberg S.D., Yaffe M.A., Koo S.S. Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Joint Surg Am 2006, 88(Suppl. 4):47-54.
    • (2006) J Bone Joint Surg Am , vol.88 , Issue.SUPPL. 4 , pp. 47-54
    • Stulberg, S.D.1    Yaffe, M.A.2    Koo, S.S.3
  • 4
    • 4043104035 scopus 로고    scopus 로고
    • Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique
    • Bathis H., Perlick L., Tingart M., Luring C., Zurakowski D., Grifka J. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 2004, 86:682-687.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 682-687
    • Bathis, H.1    Perlick, L.2    Tingart, M.3    Luring, C.4    Zurakowski, D.5    Grifka, J.6
  • 5
    • 33645916726 scopus 로고    scopus 로고
    • Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis?
    • Hinman R.S., May R.L., Crossley K.M. Is there an alternative to the full-leg radiograph for determining knee joint alignment in osteoarthritis?. Arthritis Rheum 2006, 55:306-313.
    • (2006) Arthritis Rheum , vol.55 , pp. 306-313
    • Hinman, R.S.1    May, R.L.2    Crossley, K.M.3
  • 6
    • 59649084701 scopus 로고    scopus 로고
    • Frontal knee alignment: three-dimensional marker positions and clinical assessment
    • Vanwanseele B., Parker D., Coolican M. Frontal knee alignment: three-dimensional marker positions and clinical assessment. Clin Orthop Relat Res 2009, 467:504-509.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 504-509
    • Vanwanseele, B.1    Parker, D.2    Coolican, M.3
  • 7
    • 33751243584 scopus 로고    scopus 로고
    • Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol
    • Henckel J., Richards R., Lozhkin K., Harris S., Baena F.M., Barrett A.R., et al. Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Joint Surg Br 2006, 88:1513-1518.
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 1513-1518
    • Henckel, J.1    Richards, R.2    Lozhkin, K.3    Harris, S.4    Baena, F.M.5    Barrett, A.R.6
  • 8
    • 45849107975 scopus 로고    scopus 로고
    • An MRI-based technique for assessment of lower extremity deformities-reproducibility, accuracy, and clinical application
    • Hinterwimmer S., Graichen H., Vogl T.J., Abolmaali N. An MRI-based technique for assessment of lower extremity deformities-reproducibility, accuracy, and clinical application. Eur Radiol 2008, 18:1497-1505.
    • (2008) Eur Radiol , vol.18 , pp. 1497-1505
    • Hinterwimmer, S.1    Graichen, H.2    Vogl, T.J.3    Abolmaali, N.4
  • 9
    • 16644387904 scopus 로고    scopus 로고
    • Reproducibility and reliability of the anatomic axis of the lower extremity
    • Schmidt G.L., Altman G.T., Dougherty J.T., DeMeo P.J. Reproducibility and reliability of the anatomic axis of the lower extremity. J Knee Surg 2004, 17:141-143.
    • (2004) J Knee Surg , vol.17 , pp. 141-143
    • Schmidt, G.L.1    Altman, G.T.2    Dougherty, J.T.3    DeMeo, P.J.4
  • 10
    • 37849017958 scopus 로고    scopus 로고
    • Assessment of lower limb alignment: supine fluoroscopy compared with a standing full-length radiograph
    • Sabharwal S., Zhao C. Assessment of lower limb alignment: supine fluoroscopy compared with a standing full-length radiograph. J Bone Joint Surg Am 2008, 90:43-51.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 43-51
    • Sabharwal, S.1    Zhao, C.2
  • 11
    • 79952202706 scopus 로고    scopus 로고
    • Novel approach to reducing discrepancies in radiographic and navigational limb alignments in computer-assisted TKA
    • Chung B.J., Dileep I., Chang C.B., Kang Y.G., Park Y.B., Kim T.K. Novel approach to reducing discrepancies in radiographic and navigational limb alignments in computer-assisted TKA. Orthopedics 2010, 33:62-67.
    • (2010) Orthopedics , vol.33 , pp. 62-67
    • Chung, B.J.1    Dileep, I.2    Chang, C.B.3    Kang, Y.G.4    Park, Y.B.5    Kim, T.K.6
  • 12
    • 84878225985 scopus 로고    scopus 로고
    • Plain Radiograph Fails to Reflect the Alignment and Advantages of Navigation in Total Knee Arthroplasty.
    • in press.
    • Choi WC, Lee S, An JH, Kim D, Seong SC, Lee MC. Plain Radiograph Fails to Reflect the Alignment and Advantages of Navigation in Total Knee Arthroplasty. J Arthroplasty in press.
    • J Arthroplasty
    • Choi, W.C.1    Lee, S.2    An, J.H.3    Kim, D.4    Seong, S.C.5    Lee, M.C.6
  • 13
    • 54449097679 scopus 로고    scopus 로고
    • Radiographic and navigation measurements of TKA limb alignment do not correlate
    • Yaffe M.A., Koo S.S., Stulberg S.D. Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res 2008, 466:2736-2744.
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 2736-2744
    • Yaffe, M.A.1    Koo, S.S.2    Stulberg, S.D.3
  • 15
    • 35948948171 scopus 로고    scopus 로고
    • Frontal plane knee alignment: a call for standardized measurement
    • Cooke T.D., Sled E.A., Scudamore R.A. Frontal plane knee alignment: a call for standardized measurement. J Rheumatol 2007, 34:1796-1801.
    • (2007) J Rheumatol , vol.34 , pp. 1796-1801
    • Cooke, T.D.1    Sled, E.A.2    Scudamore, R.A.3
  • 17
    • 16644379523 scopus 로고    scopus 로고
    • Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images
    • Specogna A.V., Birmingham T.B., DaSilva J.J., Milner J.S., Kerr J., Hunt M.A., et al. Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 2004, 17:203-210.
    • (2004) J Knee Surg , vol.17 , pp. 203-210
    • Specogna, A.V.1    Birmingham, T.B.2    DaSilva, J.J.3    Milner, J.S.4    Kerr, J.5    Hunt, M.A.6
  • 19
    • 0035460557 scopus 로고    scopus 로고
    • Inter- and intraobserver variability of radiographic measurements of knee alignment
    • Ilahi O.A., Kadakia N.R., Huo M.H. Inter- and intraobserver variability of radiographic measurements of knee alignment. Am J Knee Surg 2001, 14:238-242.
    • (2001) Am J Knee Surg , vol.14 , pp. 238-242
    • Ilahi, O.A.1    Kadakia, N.R.2    Huo, M.H.3
  • 20
    • 0029976887 scopus 로고    scopus 로고
    • Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties
    • Lonner J.H., Laird M.T., Stuchin S.A. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 1996, 102-106.
    • (1996) Clin Orthop Relat Res , pp. 102-106
    • Lonner, J.H.1    Laird, M.T.2    Stuchin, S.A.3
  • 21
    • 34548612002 scopus 로고    scopus 로고
    • Pitfalls in determining knee alignment: a radiographic cadaver study
    • Brouwer R.W., Jakma T.S., Brouwer K.H., Verhaar J.A. Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 2007, 20:210-215.
    • (2007) J Knee Surg , vol.20 , pp. 210-215
    • Brouwer, R.W.1    Jakma, T.S.2    Brouwer, K.H.3    Verhaar, J.A.4
  • 22
    • 0025859647 scopus 로고
    • Measurement of lower limb alignment using long radiographs
    • Wright J.G., Treble N., Feinstein A.R. Measurement of lower limb alignment using long radiographs. J Bone Joint Surg Br 1991, 73:721-723.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 721-723
    • Wright, J.G.1    Treble, N.2    Feinstein, A.R.3
  • 24
    • 77951022378 scopus 로고    scopus 로고
    • Effect of limb rotation on radiographic alignment in total knee arthroplasties
    • Radtke K., Becher C., Noll Y., Ostermeier S. Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 2010, 130:451-457.
    • (2010) Arch Orthop Trauma Surg , vol.130 , pp. 451-457
    • Radtke, K.1    Becher, C.2    Noll, Y.3    Ostermeier, S.4
  • 25
    • 0025967928 scopus 로고
    • A standardized technique for lower limb radiography. Practice, applications, and error analysis
    • Siu D., Cooke T.D., Broekhoven L.D., Lam M., Fisher B., Saunders G., et al. A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest Radiol 1991, 26:71-77.
    • (1991) Invest Radiol , vol.26 , pp. 71-77
    • Siu, D.1    Cooke, T.D.2    Broekhoven, L.D.3    Lam, M.4    Fisher, B.5    Saunders, G.6
  • 26
    • 33745301692 scopus 로고    scopus 로고
    • Regression and correlation analysis of preoperative versus intraoperative assessment of axes during navigated total knee arthroplasty
    • Oberst M., Bertsch C., Lahm A., Wuerstlin S., Holz U. Regression and correlation analysis of preoperative versus intraoperative assessment of axes during navigated total knee arthroplasty. Comput Aided Surg 2006, 11:87-91.
    • (2006) Comput Aided Surg , vol.11 , pp. 87-91
    • Oberst, M.1    Bertsch, C.2    Lahm, A.3    Wuerstlin, S.4    Holz, U.5
  • 28
    • 23044447057 scopus 로고    scopus 로고
    • Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system
    • Jenny J.Y., Boeri C., Picard F., Leitner F. Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aided Surg 2004, 9:161-165.
    • (2004) Comput Aided Surg , vol.9 , pp. 161-165
    • Jenny, J.Y.1    Boeri, C.2    Picard, F.3    Leitner, F.4
  • 29
    • 36849081392 scopus 로고    scopus 로고
    • Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty
    • Yau W.P., Leung A., Liu K.G., Yan C.H., Wong L.L., Chiu K.Y. Interobserver and intra-observer errors in obtaining visually selected anatomical landmarks during registration process in non-image-based navigation-assisted total knee arthroplasty. J Arthroplasty 2007, 22:1150-1161.
    • (2007) J Arthroplasty , vol.22 , pp. 1150-1161
    • Yau, W.P.1    Leung, A.2    Liu, K.G.3    Yan, C.H.4    Wong, L.L.5    Chiu, K.Y.6
  • 30
    • 23044515779 scopus 로고    scopus 로고
    • Intraobserver errors in obtaining visually selected anatomic landmarks during registration process in nonimage-based navigation-assisted total knee arthroplasty: a cadaveric experiment
    • Yau W.P., Leung A., Chiu K.Y., Tang W.M., Ng T.P. Intraobserver errors in obtaining visually selected anatomic landmarks during registration process in nonimage-based navigation-assisted total knee arthroplasty: a cadaveric experiment. J Arthroplasty 2005, 20:591-601.
    • (2005) J Arthroplasty , vol.20 , pp. 591-601
    • Yau, W.P.1    Leung, A.2    Chiu, K.Y.3    Tang, W.M.4    Ng, T.P.5
  • 31
    • 0034060922 scopus 로고    scopus 로고
    • Computer-aided 3D-navigation systems-a plea for an error model
    • Hauser R. Computer-aided 3D-navigation systems-a plea for an error model. HNO 2000, 48:71-74.
    • (2000) HNO , vol.48 , pp. 71-74
    • Hauser, R.1
  • 32
    • 0035707082 scopus 로고    scopus 로고
    • Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation
    • Jenny J.Y., Boeri C. Computer-assisted implantation of total knee prostheses: a case-control comparative study with classical instrumentation. Comput Aided Surg 2001, 6:217-220.
    • (2001) Comput Aided Surg , vol.6 , pp. 217-220
    • Jenny, J.Y.1    Boeri, C.2
  • 36
    • 4444262696 scopus 로고    scopus 로고
    • Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol)
    • Chauhan S.K., Clark G.W., Lloyd S., Scott R.G., Breidahl W., Sikorski J.M. Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol). J Bone Joint Surg Br 2004, 86:818-823.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 818-823
    • Chauhan, S.K.1    Clark, G.W.2    Lloyd, S.3    Scott, R.G.4    Breidahl, W.5    Sikorski, J.M.6
  • 37
    • 33845901787 scopus 로고    scopus 로고
    • Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weightbearing status and associations with dynamic joint load
    • Specogna A.V., Birmingham T.B., Hunt M.A., Jones I.C., Jenkyn T.R., Fowler P.J., et al. Radiographic measures of knee alignment in patients with varus gonarthrosis: effect of weightbearing status and associations with dynamic joint load. Am J Sports Med 2007, 35:65-70.
    • (2007) Am J Sports Med , vol.35 , pp. 65-70
    • Specogna, A.V.1    Birmingham, T.B.2    Hunt, M.A.3    Jones, I.C.4    Jenkyn, T.R.5    Fowler, P.J.6
  • 38
    • 0036394724 scopus 로고    scopus 로고
    • Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients
    • Stulberg S.D., Loan P., Sarin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 2002, 84-A(Suppl. 2):90-98.
    • (2002) J Bone Joint Surg Am , Issue.SUPPL. 2 , pp. 90-98
    • Stulberg, S.D.1    Loan, P.2    Sarin, V.3
  • 40
    • 0025360761 scopus 로고
    • Normal axial alignment of the lower extremity and load-bearing distribution at the knee
    • Hsu R.W., Himeno S., Coventry M.B., Chao E.Y. Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 1990, 215-227.
    • (1990) Clin Orthop Relat Res , pp. 215-227
    • Hsu, R.W.1    Himeno, S.2    Coventry, M.B.3    Chao, E.Y.4
  • 41
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 42
    • 65649152011 scopus 로고    scopus 로고
    • Optimizing limb position for measuring knee anatomical axis alignment from standing knee radiographs
    • Cooke T.D., Sled E.A. Optimizing limb position for measuring knee anatomical axis alignment from standing knee radiographs. J Rheumatol 2009, 36:472-477.
    • (2009) J Rheumatol , vol.36 , pp. 472-477
    • Cooke, T.D.1    Sled, E.A.2
  • 43
    • 0023893141 scopus 로고
    • Radiographic assessment of knee alignment after total knee arthroplasty
    • Petersen T.L., Engh G.A. Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 1988, 3:67-72.
    • (1988) J Arthroplasty , vol.3 , pp. 67-72
    • Petersen, T.L.1    Engh, G.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.