메뉴 건너뛰기




Volumn 29, Issue 6, 2013, Pages 644-651

Canadian Cardiovascular Society/Canadian Heart Rhythm Society Joint Position Statement on the Use of Remote Monitoring for Cardiovascular Implantable Electronic Device Follow-up

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CARDIAC EQUIPMENT; COST EFFECTIVENESS ANALYSIS; FOLLOW UP; HEALTH CARE PERSONNEL; HEALTH CARE QUALITY; HEALTH CARE UTILIZATION; HEART VENTRICLE ARRHYTHMIA; HOSPITALIZATION; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; IMPLANTED HEART PACEMAKER; MEDICAL INFORMATION; MEDICAL SOCIETY; MULTICENTER STUDY (TOPIC); PATIENT CARE; PATIENT MONITORING; PATIENT SATISFACTION; QUALITY OF LIFE; REACTION TIME; TELEMEDICINE; WEB BROWSER;

EID: 84878145813     PISSN: 0828282X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cjca.2012.11.036     Document Type: Article
Times cited : (36)

References (34)
  • 1
    • 18144441359 scopus 로고    scopus 로고
    • Guidelines for pacemaker follow-up in Canada: a consensus statement of the Canadian Working Group on Cardiac Pacing
    • 67-76
    • Fraser J.D., Gillis A.M., Irwin M.E., Nishimura S., Tyers G.F., Philippon F. Guidelines for pacemaker follow-up in Canada: a consensus statement of the Canadian Working Group on Cardiac Pacing. Can J Cardiol 2000, 16:355-363. 67-76.
    • (2000) Can J Cardiol , vol.16 , pp. 355-363
    • Fraser, J.D.1    Gillis, A.M.2    Irwin, M.E.3    Nishimura, S.4    Tyers, G.F.5    Philippon, F.6
  • 2
    • 0037218873 scopus 로고    scopus 로고
    • Guidelines for implantable cardioverter defibrillator follow-up in Canada: a consensus statement of the Canadian Working Group on Cardiac Pacing
    • Gillis A.M., Philippon F., Cassidy M.R., Singh N., Dorian P., Love B.A., et al. Guidelines for implantable cardioverter defibrillator follow-up in Canada: a consensus statement of the Canadian Working Group on Cardiac Pacing. Can J Cardiol 2003, 19:21-37.
    • (2003) Can J Cardiol , vol.19 , pp. 21-37
    • Gillis, A.M.1    Philippon, F.2    Cassidy, M.R.3    Singh, N.4    Dorian, P.5    Love, B.A.6
  • 3
    • 84856280593 scopus 로고    scopus 로고
    • ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs)
    • Dubner S., Auricchio A., Steinberg J.S., Vardas P., Stone P., Brugada J., et al. ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs). Europace 2012, 14:278-293.
    • (2012) Europace , vol.14 , pp. 278-293
    • Dubner, S.1    Auricchio, A.2    Steinberg, J.S.3    Vardas, P.4    Stone, P.5    Brugada, J.6
  • 4
    • 79951952372 scopus 로고    scopus 로고
    • GRADE guidelines: 1. Introduction-GRADE evidence profiles and summary of findings tables
    • Guyatt G., Oxman A.D., Akl E.A., Kunz R., Vist G., Brozek J., et al. GRADE guidelines: 1. Introduction-GRADE evidence profiles and summary of findings tables. J Clin Epidemiol 2011, 64:383-394.
    • (2011) J Clin Epidemiol , vol.64 , pp. 383-394
    • Guyatt, G.1    Oxman, A.D.2    Akl, E.A.3    Kunz, R.4    Vist, G.5    Brozek, J.6
  • 5
    • 58849127733 scopus 로고    scopus 로고
    • " Home monitoring" for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study
    • Hauck M., Bauer A., Voss F., Weretka S., Katus H.A., Becker R. " Home monitoring" for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 2009, 98:19-24.
    • (2009) Clin Res Cardiol , vol.98 , pp. 19-24
    • Hauck, M.1    Bauer, A.2    Voss, F.3    Weretka, S.4    Katus, H.A.5    Becker, R.6
  • 8
    • 33846289600 scopus 로고    scopus 로고
    • Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database
    • Lazarus A. Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database. Pacing Clin Electrophysiol 2007, 30(suppl 1):S2-S12.
    • (2007) Pacing Clin Electrophysiol , vol.30 , Issue.SUPPL. 1
    • Lazarus, A.1
  • 9
    • 51849166566 scopus 로고    scopus 로고
    • Remote monitoring of CRT-ICD: the multicenter Italian CareLink evaluation-ease of use, acceptance, and organizational implications
    • Marzegalli M., Lunati M., Landolina M., Perego G.B., Ricci R.P., Guenzati G., et al. Remote monitoring of CRT-ICD: the multicenter Italian CareLink evaluation-ease of use, acceptance, and organizational implications. Pacing Clin Electrophysiol 2008, 31:1259-1264.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1259-1264
    • Marzegalli, M.1    Lunati, M.2    Landolina, M.3    Perego, G.B.4    Ricci, R.P.5    Guenzati, G.6
  • 10
    • 44649140938 scopus 로고    scopus 로고
    • Automatic home monitoring of implantable cardioverter defibrillators
    • Nielsen J.C., Kottkamp H., Zabel M., Aliot E., Kreutzer U., Bauer A., et al. Automatic home monitoring of implantable cardioverter defibrillators. Europace 2008, 10:729-735.
    • (2008) Europace , vol.10 , pp. 729-735
    • Nielsen, J.C.1    Kottkamp, H.2    Zabel, M.3    Aliot, E.4    Kreutzer, U.5    Bauer, A.6
  • 11
    • 52949146708 scopus 로고    scopus 로고
    • Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up
    • Raatikainen M.J., Uusimaa P., van Ginneken M.M., Janssen J.P., Linnaluoto M. Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up. Europace 2008, 10:1145-1151.
    • (2008) Europace , vol.10 , pp. 1145-1151
    • Raatikainen, M.J.1    Uusimaa, P.2    van Ginneken, M.M.3    Janssen, J.P.4    Linnaluoto, M.5
  • 12
    • 77951968213 scopus 로고    scopus 로고
    • Long-term patient acceptance of and satisfaction with implanted device remote monitoring
    • Ricci R.P., Morichelli L., Quarta L., Sassi A., Porfili A., Laudadio M.T., et al. Long-term patient acceptance of and satisfaction with implanted device remote monitoring. Europace 2010, 12:674-679.
    • (2010) Europace , vol.12 , pp. 674-679
    • Ricci, R.P.1    Morichelli, L.2    Quarta, L.3    Sassi, A.4    Porfili, A.5    Laudadio, M.T.6
  • 13
    • 41949103591 scopus 로고    scopus 로고
    • Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization
    • Ricci R.P., Morichelli L., Santini M. Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization. Europace 2008, 10:164-170.
    • (2008) Europace , vol.10 , pp. 164-170
    • Ricci, R.P.1    Morichelli, L.2    Santini, M.3
  • 14
    • 58149099012 scopus 로고    scopus 로고
    • Remote control of implanted devices through home monitoring technology improves detection and clinical management of atrial fibrillation
    • Ricci R.P., Morichelli L., Santini M. Remote control of implanted devices through home monitoring technology improves detection and clinical management of atrial fibrillation. Europace 2009, 11:54-61.
    • (2009) Europace , vol.11 , pp. 54-61
    • Ricci, R.P.1    Morichelli, L.2    Santini, M.3
  • 15
    • 65249178883 scopus 로고    scopus 로고
    • Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population
    • Sacher F., Probst V., Bessouet M., Wright M., Maluski A., Abbey S., et al. Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population. Europace 2009, 11:489-494.
    • (2009) Europace , vol.11 , pp. 489-494
    • Sacher, F.1    Probst, V.2    Bessouet, M.3    Wright, M.4    Maluski, A.5    Abbey, S.6
  • 17
    • 60849098171 scopus 로고    scopus 로고
    • Analysis of 57,148 transmissions by remote monitoring of implantable cardioverter defibrillators
    • Theuns D.A., Rivero-Ayerza M., Knops P., Res J.C., Jordaens L. Analysis of 57,148 transmissions by remote monitoring of implantable cardioverter defibrillators. Pacing Clin Electrophysiol 2009, 32(suppl 1):S63-S65.
    • (2009) Pacing Clin Electrophysiol , vol.32 , Issue.SUPPL. 1
    • Theuns, D.A.1    Rivero-Ayerza, M.2    Knops, P.3    Res, J.C.4    Jordaens, L.5
  • 18
    • 12844258988 scopus 로고    scopus 로고
    • Detection of atrial fibrillation by implanted devices with wireless data transmission capability
    • Varma N., Stambler B., Chun S. Detection of atrial fibrillation by implanted devices with wireless data transmission capability. Pacing Clin Electrophysiol 2005, 28(suppl 1):S133-S136.
    • (2005) Pacing Clin Electrophysiol , vol.28 , Issue.SUPPL. 1
    • Varma, N.1    Stambler, B.2    Chun, S.3
  • 19
    • 33645402551 scopus 로고    scopus 로고
    • What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?
    • Brugada P. What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?. Clin Res Cardiol 2006, 95(suppl 3):III3-III9.
    • (2006) Clin Res Cardiol , vol.95 , Issue.SUPPL. 3 , pp. 33-39
    • Brugada, P.1
  • 20
    • 77956932471 scopus 로고    scopus 로고
    • Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory
    • Guedon-Moreau L., Chevalier P., Marquie C., Kouakam C., Klug D., Lacroix D., et al. Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory. Eur Heart J 2010, 31:2246-2252.
    • (2010) Eur Heart J , vol.31 , pp. 2246-2252
    • Guedon-Moreau, L.1    Chevalier, P.2    Marquie, C.3    Kouakam, C.4    Klug, D.5    Lacroix, D.6
  • 21
    • 65249116913 scopus 로고    scopus 로고
    • Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
    • Spencker S., Coban N., Koch L., Schirdewan A., Muller D. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Europace 2009, 11:483-488.
    • (2009) Europace , vol.11 , pp. 483-488
    • Spencker, S.1    Coban, N.2    Koch, L.3    Schirdewan, A.4    Muller, D.5
  • 22
    • 33645394387 scopus 로고    scopus 로고
    • Predicting mortality and rehospitalization in heart failure patients with home monitoring-the Home CARE pilot study
    • Ellery S., Pakrashi T., Paul V., Sack S. Predicting mortality and rehospitalization in heart failure patients with home monitoring-the Home CARE pilot study. Clin Res Cardiol 2006, 95(suppl 3):III29-III35.
    • (2006) Clin Res Cardiol , vol.95 , Issue.SUPPL. 3 , pp. 329-335
    • Ellery, S.1    Pakrashi, T.2    Paul, V.3    Sack, S.4
  • 24
    • 77955152767 scopus 로고    scopus 로고
    • Insights from internet-based remote intrathoracic impedance monitoring as part of a heart failure disease management program
    • Mullens W., Oliveira L.P., Verga T., Wilkoff B.L., Wilson Tang W.H. Insights from internet-based remote intrathoracic impedance monitoring as part of a heart failure disease management program. Congest Heart Fail 2010, 16:159-163.
    • (2010) Congest Heart Fail , vol.16 , pp. 159-163
    • Mullens, W.1    Oliveira, L.P.2    Verga, T.3    Wilkoff, B.L.4    Wilson Tang, W.H.5
  • 25
    • 59449094988 scopus 로고    scopus 로고
    • Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes
    • Santini M., Ricci R.P., Lunati M., Landolina M., Perego G.B., Marzegalli M., et al. Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes. J Interv Card Electrophysiol 2009, 24:53-61.
    • (2009) J Interv Card Electrophysiol , vol.24 , pp. 53-61
    • Santini, M.1    Ricci, R.P.2    Lunati, M.3    Landolina, M.4    Perego, G.B.5    Marzegalli, M.6
  • 26
    • 57149089288 scopus 로고    scopus 로고
    • Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial
    • Halimi F., Clementy J., Attuel P., Dessenne X., Amara W. Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial. Europace 2008, 10:1392-1399.
    • (2008) Europace , vol.10 , pp. 1392-1399
    • Halimi, F.1    Clementy, J.2    Attuel, P.3    Dessenne, X.4    Amara, W.5
  • 27
    • 71849093450 scopus 로고    scopus 로고
    • Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers
    • Crossley G.H., Chen J., Choucair W., Cohen T.J., Gohn D.C., Johnson W.B., et al. Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers. J Am Coll Cardiol 2009, 54:2012-2019.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 2012-2019
    • Crossley, G.H.1    Chen, J.2    Choucair, W.3    Cohen, T.J.4    Gohn, D.C.5    Johnson, W.B.6
  • 28
    • 77951176996 scopus 로고    scopus 로고
    • Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: results from a randomized pilot clinical trial
    • Al-Khatib S.M., Piccini J.P., Knight D., Stewart M., Clapp-Channing N., Sanders G.D. Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: results from a randomized pilot clinical trial. J Cardiovasc Electrophysiol 2010, 21:545-550.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 545-550
    • Al-Khatib, S.M.1    Piccini, J.P.2    Knight, D.3    Stewart, M.4    Clapp-Channing, N.5    Sanders, G.D.6
  • 29
    • 78149246712 scopus 로고    scopus 로고
    • Cost savings and safety of ICD remote control by telephone: a prospective, observational study
    • Bikou O., Licka M., Kathoefer S., Katus H.A., Bauer A. Cost savings and safety of ICD remote control by telephone: a prospective, observational study. J Telemed Telecare 2010, 16:403-408.
    • (2010) J Telemed Telecare , vol.16 , pp. 403-408
    • Bikou, O.1    Licka, M.2    Kathoefer, S.3    Katus, H.A.4    Bauer, A.5
  • 30
    • 79952312933 scopus 로고    scopus 로고
    • The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts
    • Crossley G.H., Boyle A., Vitense H., Chang Y., Mead R.H. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts. J Am Coll Cardiol 2011, 57:1181-1189.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1181-1189
    • Crossley, G.H.1    Boyle, A.2    Vitense, H.3    Chang, Y.4    Mead, R.H.5
  • 31
    • 44649168555 scopus 로고    scopus 로고
    • A prospective multicenter comparison trial of home monitoring against regular follow-up in MADIT II patients: additional visits and cost impact
    • Elsner C.H., Sommer P., Piorkowski C., Taborsky M., Neuser H., Bytesnik J., et al. A prospective multicenter comparison trial of home monitoring against regular follow-up in MADIT II patients: additional visits and cost impact. Comput Cardiol 2006, 33:241-244.
    • (2006) Comput Cardiol , vol.33 , pp. 241-244
    • Elsner, C.H.1    Sommer, P.2    Piorkowski, C.3    Taborsky, M.4    Neuser, H.5    Bytesnik, J.6
  • 32
    • 77955171126 scopus 로고    scopus 로고
    • Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial
    • Varma N., Epstein A.E., Irimpen A., Schweikert R., Love C. Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial. Circulation 2010, 122:325-332.
    • (2010) Circulation , vol.122 , pp. 325-332
    • Varma, N.1    Epstein, A.E.2    Irimpen, A.3    Schweikert, R.4    Love, C.5
  • 33
    • 84878135116 scopus 로고    scopus 로고
    • EVATEL: Remote follow-up of patients implanted with an ICD: the prospective randomized EVATEL study. Paper presented at: European Society of Cardiology Congress 2011. August 27-31, Paris, France.
    • Mabo P, Defaye P, Sadoul N, et al. EVATEL: Remote follow-up of patients implanted with an ICD: the prospective randomized EVATEL study. Paper presented at: European Society of Cardiology Congress 2011. August 27-31, 2011; Paris, France.
    • (2011)
    • Mabo, P.1    Defaye, P.2    Sadoul, N.3
  • 34
    • 84874478830 scopus 로고    scopus 로고
    • A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial
    • Guedon-Moreau L., Lacroix D., Sadoul N., et al. A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial. Eur Heart J 2013, 348:605-614.
    • (2013) Eur Heart J , vol.348 , pp. 605-614
    • Guedon-Moreau, L.1    Lacroix, D.2    Sadoul, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.