-
1
-
-
75149116276
-
Serum vitamin A and E analysis: comparison of methods between laboratories enrolled in an external quality assurance programme
-
Greaves R., Jolly L., Woollard G., Hoad K. Serum vitamin A and E analysis: comparison of methods between laboratories enrolled in an external quality assurance programme. Ann Clin Biochem 2010, 47:78-80.
-
(2010)
Ann Clin Biochem
, vol.47
, pp. 78-80
-
-
Greaves, R.1
Jolly, L.2
Woollard, G.3
Hoad, K.4
-
2
-
-
84877835975
-
-
Dutch Foundation for Quality Assessment in Medical Laboratories (SKML), Available at, [accessed 15/01/2013]
-
Dutch Foundation for Quality Assessment in Medical Laboratories (SKML) Available at, [accessed 15/01/2013]. http://www.skml.nl/en/home?op=setLanguage;language=English.
-
-
-
-
3
-
-
84877807252
-
-
Society for Promoting Quality Assurance in Medical Laboratories (INSTAND e.V), Available at, [accessed 15/01/2013]
-
Society for Promoting Quality Assurance in Medical Laboratories (INSTAND e.V) Available at, [accessed 15/01/2013]. http://www.instandev.de/en.html.
-
-
-
-
4
-
-
0034625636
-
Review: determination of thiamine by high-performance liquid chromatography
-
Lynch P.L.M., Young I.S. Review: determination of thiamine by high-performance liquid chromatography. J Chromatogr A 2000, 881:267-284.
-
(2000)
J Chromatogr A
, vol.881
, pp. 267-284
-
-
Lynch, P.L.M.1
Young, I.S.2
-
5
-
-
43449103357
-
Rapid HPLC measurement of thiamine and its phosphate esters in whole blood
-
Lu J., Frank E.L. Rapid HPLC measurement of thiamine and its phosphate esters in whole blood. Clin Chem 2008, 54:901-906.
-
(2008)
Clin Chem
, vol.54
, pp. 901-906
-
-
Lu, J.1
Frank, E.L.2
-
6
-
-
0036605604
-
Determination of vitamin B6 vitamers and pyridoxic acid in plasma: development and evaluation of a high performance liquid chromatographic assay
-
Bisp M.R., Mustafa V.B., Heinsvig E.-M., Kall M.A., Nexø E. Determination of vitamin B6 vitamers and pyridoxic acid in plasma: development and evaluation of a high performance liquid chromatographic assay. Anal Biochem 2002, 305:82-89.
-
(2002)
Anal Biochem
, vol.305
, pp. 82-89
-
-
Bisp, M.R.1
Mustafa, V.B.2
Heinsvig, E.-M.3
Kall, M.A.4
Nexø, E.5
-
7
-
-
4644306124
-
Clinical analysis of vitamin B6: determination of pyridoxal 5'-phosphate and 4-pyridoxic acid in human serum by reversed-phase high-performance liquid chromatography with chlorite postcolumn derivatization
-
Rybak M.E., Pfeiffer C.M. Clinical analysis of vitamin B6: determination of pyridoxal 5'-phosphate and 4-pyridoxic acid in human serum by reversed-phase high-performance liquid chromatography with chlorite postcolumn derivatization. Anal Biochem 2004, 333:336-344.
-
(2004)
Anal Biochem
, vol.333
, pp. 336-344
-
-
Rybak, M.E.1
Pfeiffer, C.M.2
-
8
-
-
59949097450
-
The Joint Committee for Traceability in Laboratory Medicine (JCTLM): a global approach to promote standardisation of clinical laboratory test results
-
Armbruster D., Miller R.R. The Joint Committee for Traceability in Laboratory Medicine (JCTLM): a global approach to promote standardisation of clinical laboratory test results. Clin Biochem Rev 2007, 28:105-113.
-
(2007)
Clin Biochem Rev
, vol.28
, pp. 105-113
-
-
Armbruster, D.1
Miller, R.R.2
-
9
-
-
84872374096
-
A guide to harmonisation and standardisation of measurands determined by liquid chromatography - tandem mass spectrometry in routine clinical biochemistry
-
Greaves R.F. A guide to harmonisation and standardisation of measurands determined by liquid chromatography - tandem mass spectrometry in routine clinical biochemistry. Clin Biochem Rev 2012, 33:123-132.
-
(2012)
Clin Biochem Rev
, vol.33
, pp. 123-132
-
-
Greaves, R.F.1
-
10
-
-
84877799411
-
-
RCPA Quality Assurance Programs-vitamin program, Available at, [accessed 21/11/2012]
-
RCPA Quality Assurance Programs - vitamin program End of Cycle Report Cycle 22 Available at, [accessed 21/11/2012]. http://www.rcpaqap.com.au/chempath.
-
End of Cycle Report Cycle 22
-
-
-
11
-
-
84877830808
-
-
Instruction manual for the HPLC analysis of vitamin B1 in whole blood and vitamin B6 in whole blood/plasma. (IM 52000 VITB1B6K E Mar R1) Chromsystems, Munich, Germany
-
Instruction manual for the HPLC analysis of vitamin B1 in whole blood and vitamin B6 in whole blood/plasma. (IM 52000 VITB1B6K E Mar 2008 R1) Chromsystems, Munich, Germany.
-
(2008)
-
-
-
12
-
-
22244472287
-
The analysis of thiamine and its derivatives in whole blood samples under high pH conditions of the mobile phase
-
Van Landeghem B.A.J., Puts J., Claessens H.A. The analysis of thiamine and its derivatives in whole blood samples under high pH conditions of the mobile phase. J Chromatogr B 2005, 822:316-321.
-
(2005)
J Chromatogr B
, vol.822
, pp. 316-321
-
-
Van Landeghem, B.A.J.1
Puts, J.2
Claessens, H.A.3
-
13
-
-
23444447854
-
Multianalyte quantification of vitamin B6 and B2 species in the nanomolar range in human plasma by liquid chromatography-tandem mass spectrometry
-
Midttun Ø., Hustad S., Solhsin E., Schneede J., Ueland P.M. Multianalyte quantification of vitamin B6 and B2 species in the nanomolar range in human plasma by liquid chromatography-tandem mass spectrometry. Clin Chem 2005, 51:1206-1216.
-
(2005)
Clin Chem
, vol.51
, pp. 1206-1216
-
-
Midttun, Ø.1
Hustad, S.2
Solhsin, E.3
Schneede, J.4
Ueland, P.M.5
-
14
-
-
0030788817
-
High-performance liquid chromatographic determination of thiamine diphosphate in erythrocytes using internal standard methodology
-
Lynch P.L.M., Trimble E.R., Young I.S. High-performance liquid chromatographic determination of thiamine diphosphate in erythrocytes using internal standard methodology. J Chromatogr B Biomed Sci Appl 1997, 701:120-123.
-
(1997)
J Chromatogr B Biomed Sci Appl
, vol.701
, pp. 120-123
-
-
Lynch, P.L.M.1
Trimble, E.R.2
Young, I.S.3
-
15
-
-
0025663071
-
Vitamin B6: a status report
-
Leklem J.E. Vitamin B6: a status report. J Nutr 1990, 120(Suppl. 11):1503-1507.
-
(1990)
J Nutr
, vol.120
, Issue.SUPPL. 11
, pp. 1503-1507
-
-
Leklem, J.E.1
-
16
-
-
0022360715
-
Half-of-the-site reactivity of the decarboxylating component of the pyruvate dehydrogenase complex from pigeon breast muscle with respect to 2-hydroxyethyl thiamine pyrophosphate
-
Khailova L.S., Korochkina L.G. Half-of-the-site reactivity of the decarboxylating component of the pyruvate dehydrogenase complex from pigeon breast muscle with respect to 2-hydroxyethyl thiamine pyrophosphate. Biochem Int 1985, 11(4):509-516.
-
(1985)
Biochem Int
, vol.11
, Issue.4
, pp. 509-516
-
-
Khailova, L.S.1
Korochkina, L.G.2
-
17
-
-
0016173901
-
Reaction of pyridoxal 5'-sulfate with apoenzyme of aspartate aminotransferase. Covalent labeling of the protein with elimination of sulfate
-
Yang In-Yu, Khomutov R.M., Metzler D.E. Reaction of pyridoxal 5'-sulfate with apoenzyme of aspartate aminotransferase. Covalent labeling of the protein with elimination of sulfate. Biochemistry 1974, 13(19):3877-3884.
-
(1974)
Biochemistry
, vol.13
, Issue.19
, pp. 3877-3884
-
-
Yang, I.-Y.1
Khomutov, R.M.2
Metzler, D.E.3
-
19
-
-
23444440173
-
Clinical vitamin B6 analysis: an interlaboratory comparison of pyridoxal-5'-phosphate measurements in serum
-
Ryback M.E., Jain R.B., Pfieffer C.M. Clinical vitamin B6 analysis: an interlaboratory comparison of pyridoxal-5'-phosphate measurements in serum. Clin Chem 2005, 51(7):1223-1231.
-
(2005)
Clin Chem
, vol.51
, Issue.7
, pp. 1223-1231
-
-
Ryback, M.E.1
Jain, R.B.2
Pfieffer, C.M.3
-
20
-
-
84872397848
-
Application of the Stockholm Hierarchy to defining the quality of reference intervals and clinical decision limits
-
Sikaris K. Application of the Stockholm Hierarchy to defining the quality of reference intervals and clinical decision limits. Clin Biochem Rev 2012, 33(iv):141-148.
-
(2012)
Clin Biochem Rev
, vol.33
, Issue.4
, pp. 141-148
-
-
Sikaris, K.1
|