메뉴 건너뛰기




Volumn 16, Issue 4, 2012, Pages 1105-1112

Pulse transit time: Validation of blood pressure measurement under positive airway pressure ventilation

Author keywords

Arterial blood pressure measurement; Continuous positive airway pressure (CPAP); Pulse transit time; Sleep disordered breathing

Indexed keywords

ADULT; AGED; ARTICLE; CORRELATION ANALYSIS; DIASTOLIC BLOOD PRESSURE; FEMALE; HEART RATE; HUMAN; MAJOR CLINICAL STUDY; MALE; NON INVASIVE BLOOD PRESSURE MONITOR; OSCILLOMETRY; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; PULSE TRANSIT TIME; QUALITY CONTROL; SIGNAL DETECTION; SLEEP; SYSTOLIC BLOOD PRESSURE; VALIDATION STUDY; BLOOD PRESSURE; CENTRAL SLEEP APNEA SYNDROME; INSTRUMENTATION; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; POLYSOMNOGRAPHY; PULSE WAVE; REPRODUCIBILITY; SIGNAL PROCESSING; SLEEP DISORDERED BREATHING;

EID: 84877137018     PISSN: 15209512     EISSN: 15221709     Source Type: Journal    
DOI: 10.1007/s11325-011-0609-7     Document Type: Article
Times cited : (25)

References (27)
  • 1
    • 70149107467 scopus 로고    scopus 로고
    • The acute effects of running on blood pressure estimation using pulse transit time in normotensive subjects
    • 19543907 10.1007/s00421-009-1112-8
    • Wong MY, Pickwell-MacPherson E, Zhang YT (2009) The acute effects of running on blood pressure estimation using pulse transit time in normotensive subjects. Eur J Appl Physiol 107:169-175
    • (2009) Eur J Appl Physiol , vol.107 , pp. 169-175
    • Wong, M.Y.1    Pickwell-Macpherson, E.2    Zhang, Y.T.3
  • 2
    • 0031710038 scopus 로고    scopus 로고
    • Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/ hypopnoea syndrome
    • 9762800 10.1183/09031936.98.12030685 1:STN:280:DyaK1cvjtlOltg%3D%3D
    • Pitson DJ, Stradling JR (1998) Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/ hypopnoea syndrome. Eur Respir J 12:685-692
    • (1998) Eur Respir J , vol.12 , pp. 685-692
    • Pitson, D.J.1    Stradling, J.R.2
  • 3
    • 33745130717 scopus 로고    scopus 로고
    • Evaluation of blood pressure changes using vascular transit time
    • 16772667 10.1088/0967-3334/27/8/003
    • Foo JY, Lim CS, Wang P (2006) Evaluation of blood pressure changes using vascular transit time. Physiol Meas 27:685-694
    • (2006) Physiol Meas , vol.27 , pp. 685-694
    • Foo, J.Y.1    Lim, C.S.2    Wang, P.3
  • 4
    • 0028789504 scopus 로고
    • Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea
    • 8586120 10.1183/09031936.95.08101669 1:STN:280:DyaK287mtlyjsA%3D%3D
    • Pitson DJ, Sandell A, van den Hout R, Stradling JR (1995) Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. Eur Respir J 8:1669-1674
    • (1995) Eur Respir J , vol.8 , pp. 1669-1674
    • Pitson, D.J.1    Sandell, A.2    Van Den Hout, R.3    Stradling, J.R.4
  • 5
    • 0032897226 scopus 로고    scopus 로고
    • Pulse transit time: An appraisal of potential clinical applications
    • 10212114 10.1136/thx.54.5.452 1:STN:280:DyaK1MzgvFWgtg%3D%3D
    • Smith RP, Argod J, Pépin JL, Lévy PA (1999) Pulse transit time: an appraisal of potential clinical applications. Thorax 54:452-457
    • (1999) Thorax , vol.54 , pp. 452-457
    • Smith, R.P.1    Argod, J.2    Pépin, J.L.3    Lévy, P.A.4
  • 6
    • 33644822671 scopus 로고    scopus 로고
    • Pulse transit time measured from the ECG: An unreliable marker of beat-to-beat blood pressure
    • 10.1152/japplphysiol.00657.2005 1:STN:280:DC%2BD2MnmvFCksA%3D%3D
    • Payne RA, Symeonides CN, Webb DJ, Maxwell SR (2006) Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. Eur J Appl Physiol 100:136-141
    • (2006) Eur J Appl Physiol , vol.100 , pp. 136-141
    • Payne, R.A.1    Symeonides, C.N.2    Webb, D.J.3    Maxwell, S.R.4
  • 7
    • 0345040792 scopus 로고    scopus 로고
    • Differentiating obstructive and central sleep respiratory events through pulse transit time
    • 9847267 1:STN:280:DyaK1M%2FmsFKmsQ%3D%3D
    • Argod J, Pépin JL, Lévy P (1998) Differentiating obstructive and central sleep respiratory events through pulse transit time. Am J Respir Crit Care Med 158:1778-1783
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 1778-1783
    • Argod, J.1    Pépin, J.L.2    Lévy, P.3
  • 8
    • 70349309338 scopus 로고    scopus 로고
    • The role of pulse transit time as an index of arterial stiffness during exercise
    • 19657732 10.1007/s10558-009-9081-4 1:STN:280:DC%2BD1MnivVSmsg%3D%3D
    • Kounalakis SN, Geladas ND (2009) The role of pulse transit time as an index of arterial stiffness during exercise. Cardiovasc Eng 9:92-97
    • (2009) Cardiovasc Eng , vol.9 , pp. 92-97
    • Kounalakis, S.N.1    Geladas, N.D.2
  • 9
    • 78649512555 scopus 로고    scopus 로고
    • Validation of continuous blood pressure measurements by pulse transit time: A comparison with invasive measurements in a cardiac intensive care unit
    • 21108154 10.1055/s-0030-1269408 1:STN:280:DC%2BC3M%2FjsF2nug%3D%3D
    • Bartsch S, Ostojic D, Schmalgemeier H, Bitter T, Westerheide N, Eckert S, Horstkotte D, Oldenburg O (2010) Validation of continuous blood pressure measurements by pulse transit time: a comparison with invasive measurements in a cardiac intensive care unit. Dtsch Med Wochenschr 135:2406-2412
    • (2010) Dtsch Med Wochenschr , vol.135 , pp. 2406-2412
    • Bartsch, S.1    Ostojic, D.2    Schmalgemeier, H.3    Bitter, T.4    Westerheide, N.5    Eckert, S.6    Horstkotte, D.7    Oldenburg, O.8
  • 11
    • 34047183788 scopus 로고    scopus 로고
    • An evalutation of a PTT-based method for noninvasive and cuffless estimation of arterial blood pressure
    • 17946738 1:STN:280:DC%2BD2snis1elsQ%3D%3D
    • Teng XF, Zhang YT (2006) An evalutation of a PTT-based method for noninvasive and cuffless estimation of arterial blood pressure. Conf Proc IEEE Eng Med Biol Soc 1:6049-6052
    • (2006) Conf Proc IEEE Eng Med Biol Soc , vol.1 , pp. 6049-6052
    • Teng, X.F.1    Zhang, Y.T.2
  • 12
    • 0033786323 scopus 로고    scopus 로고
    • Hemodynamic effects of noninvasive bilevel positive airway pressure on patients with chronic congestive heart failure with systolic dysfunction
    • 11035670 10.1378/chest.118.4.1004 1:STN:280:DC%2BD3M%2FisVOjug%3D%3D
    • Acosta B, DiBenedetto R, Rahimi A, Acosta MF, Cuadra O, Van Nguyen A, Morrow L (2000) Hemodynamic effects of noninvasive bilevel positive airway pressure on patients with chronic congestive heart failure with systolic dysfunction. Chest 118:1004-1009
    • (2000) Chest , vol.118 , pp. 1004-1009
    • Acosta, B.1    Dibenedetto, R.2    Rahimi, A.3    Acosta, M.F.4    Cuadra, O.5    Van Nguyen, A.6    Morrow, L.7
  • 13
    • 84867578517 scopus 로고    scopus 로고
    • Hypotensive effects of positive airway pressure ventilation in heart failure patients with sleep-disordered breathing
    • doi: 10.1007/s11325-011-0571-4, epub ahead of print
    • Oldenburg O, Bartsch S, Bitter T, Schmalgemeier H, Fischbach T, Westerheide N, Horstkotte D (2011) Hypotensive effects of positive airway pressure ventilation in heart failure patients with sleep-disordered breathing. Sleep Breath. doi: 10.1007/s11325-011-0571-4, epub ahead of print
    • (2011) Sleep Breath
    • Oldenburg, O.1    Bartsch, S.2    Bitter, T.3    Schmalgemeier, H.4    Fischbach, T.5    Westerheide, N.6    Horstkotte, D.7
  • 14
    • 0027286224 scopus 로고
    • Adiposity and cardiovascular risk factors in men with obstructive sleep apnea
    • 8486007 10.1378/chest.103.5.1336 1:STN:280:DyaK3s3ltFynsA%3D%3D
    • Levinson PD, McGarvey ST, Carlisle CC, Eveloff SE, Herbert PN, Millman RP (1993) Adiposity and cardiovascular risk factors in men with obstructive sleep apnea. Chest 103:1336-1342
    • (1993) Chest , vol.103 , pp. 1336-1342
    • Levinson, P.D.1    McGarvey, S.T.2    Carlisle, C.C.3    Eveloff, S.E.4    Herbert, P.N.5    Millman, R.P.6
  • 16
    • 19944432785 scopus 로고    scopus 로고
    • Ambulatory blood pressure and 10-year risk of cardiovascular and noncardiovascular mortality: The Ohasama study
    • 15596571 10.1161/01.HYP.0000152079.04553.2c 1:CAS:528: DC%2BD2MXmtVWgtg%3D%3D
    • Kikuya M, Ohkubo T, Asayama K, Metoki H, Obara T, Saito S, Hashimoto J, Totsune K, Hoshi H, Satoh H, Imai Y (2005) Ambulatory blood pressure and 10-year risk of cardiovascular and noncardiovascular mortality: the Ohasama study. Hypertension 45:240-245
    • (2005) Hypertension , vol.45 , pp. 240-245
    • Kikuya, M.1    Ohkubo, T.2    Asayama, K.3    Metoki, H.4    Obara, T.5    Saito, S.6    Hashimoto, J.7    Totsune, K.8    Hoshi, H.9    Satoh, H.10    Imai, Y.11
  • 17
    • 0033935353 scopus 로고    scopus 로고
    • Prognostic value of nighttime blood pressure in the eldery: A prospective study of 24-hour blood pressure
    • 10912768 10.1291/hypres.23.323 1:STN:280:DC%2BD3M%2FisFaguw%3D%3D
    • Suzuki Y, Kuwajima I, Aono T, Kanemaru A, Nishinaga M, Shibata H, Ozawa T (2000) Prognostic value of nighttime blood pressure in the eldery: a prospective study of 24-hour blood pressure. Hypertens Res 23:323-330
    • (2000) Hypertens Res , vol.23 , pp. 323-330
    • Suzuki, Y.1    Kuwajima, I.2    Aono, T.3    Kanemaru, A.4    Nishinaga, M.5    Shibata, H.6    Ozawa, T.7
  • 18
    • 36048953764 scopus 로고    scopus 로고
    • The Stamp of Quality of the German Hypertension League for the clinical validation of blood pressure measuring devices: Results from 51 devices under test
    • 10.1055/s-2006-955060
    • Tholl U, Anlauf M, Lichtblau U, Dammer R, Roggenbuck U (2006) The Stamp of Quality of the German Hypertension League for the clinical validation of blood pressure measuring devices: results from 51 devices under test. Dtsch Med Wochenschr 131:31-36
    • (2006) Dtsch Med Wochenschr , vol.131 , pp. 31-36
    • Tholl, U.1    Anlauf, M.2    Lichtblau, U.3    Dammer, R.4    Roggenbuck, U.5
  • 19
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
    • 12040236 10.1097/00126097-200202000-00002
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, Mengden T, Imai Y, Waeber B, Palatini P, Gerin W (2002) Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 7:3-17
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6    Mengden, T.7    Imai, Y.8    Waeber, B.9    Palatini, P.10    Gerin, W.11
  • 20
    • 0029160570 scopus 로고
    • Clinical evaluation of continious noninvasive blood pressure monitoring: Accuracy and tracking capabilities
    • 7561998 10.1007/BF01617519 1:STN:280:DyaK28%2FktVGktQ%3D%3D
    • Young CC, Mark JB, White W, DeBree A, Vender JS, Fleming A (1995) Clinical evaluation of continious noninvasive blood pressure monitoring: accuracy and tracking capabilities. J Clin Monit 11:245-252
    • (1995) J Clin Monit , vol.11 , pp. 245-252
    • Young, C.C.1    Mark, J.B.2    White, W.3    Debree, A.4    Vender, J.S.5    Fleming, A.6
  • 22
    • 0030333232 scopus 로고    scopus 로고
    • Noninvasive continuous blood pressure control by pulse wave velocity
    • 8896315
    • Lutter N, Engl HG, Fischer F, Bauer RD (1996) Noninvasive continuous blood pressure control by pulse wave velocity. Z Kardiol 85:124-126
    • (1996) Z Kardiol , vol.85 , pp. 124-126
    • Lutter, N.1    Engl, H.G.2    Fischer, F.3    Bauer, R.D.4
  • 23
    • 0032033740 scopus 로고    scopus 로고
    • Continuous blood pressure monitoring during stress ECG
    • 10.1515/bmte.1998.43.3.34 1:STN:280:DyaK1c3hslKktQ%3D%3D
    • Barschdorff D, Erig M (1998) Continuous blood pressure monitoring during stress ECG. Biomed Tech 43:34-39
    • (1998) Biomed Tech , vol.43 , pp. 34-39
    • Barschdorff, D.1    Erig, M.2
  • 24
    • 0034281859 scopus 로고    scopus 로고
    • Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    • 11094816 10.1007/BF02345755 1:STN:280:DC%2BD3M%2Fks1Kkuw%3D%3D
    • Chen W, Kobayashi T, Ichikawa S, Takeuchi Y, Togawa T (2000) Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med Biol Eng Comput 38:569-574
    • (2000) Med Biol Eng Comput , vol.38 , pp. 569-574
    • Chen, W.1    Kobayashi, T.2    Ichikawa, S.3    Takeuchi, Y.4    Togawa, T.5
  • 26
    • 42249088432 scopus 로고    scopus 로고
    • How much influence does inspiration have on pulse transit time in sleep apnea?
    • 18439468 10.1016/j.otohns.2007.12.031
    • Yin M, Nakayama M, Miyazaki S, Ishikawa K (2008) How much influence does inspiration have on pulse transit time in sleep apnea? Otolaryngol Head Neck Surg 138:619-625
    • (2008) Otolaryngol Head Neck Surg , vol.138 , pp. 619-625
    • Yin, M.1    Nakayama, M.2    Miyazaki, S.3    Ishikawa, K.4
  • 27
    • 0019445970 scopus 로고
    • Comparison of direct and indirect methods of measuring arterial blood pressure
    • 7015083 1:STN:280:DyaL3M7ps12jsA%3D%3D
    • Bruner JM, Krenis LJ, Kunsman JM, Sherman AP (1981) Comparison of direct and indirect methods of measuring arterial blood pressure. Med Instrum 15:11-21
    • (1981) Med Instrum , vol.15 , pp. 11-21
    • Bruner, J.M.1    Krenis, L.J.2    Kunsman, J.M.3    Sherman, A.P.4